• Title/Summary/Keyword: optics

Search Result 5,436, Processing Time 0.024 seconds

G1 Arrest of the Cell Cycle by Gomisin N, a Dibenzocyclooctadiene Lignan, Isolated from Schizandra chinensis Baill in Human Leukemia U937 Cells (오미자에서 분리된 dibenzocyclooctadiene lignan의 일종인 gomisin N에 의한 인체혈구암세포의 세포주기 G1 arrest 유발)

  • Park, Cheol;Hwang, Hye-Jin;Choi, Byung-Tae;Choi, Tae-Hyun;Kim, Byung-Woo;Choi, Young-Whan;Choi, Yung-Hyun
    • Journal of Life Science
    • /
    • v.20 no.7
    • /
    • pp.977-982
    • /
    • 2010
  • We investigated the anti-cancer effects of two dibenzocyclooctadiene lignans, gomisin A and gomisin N, isolated from Schizandra chinensis Baill, in human promyelocytic U937 cells. Gomisin N, but not gomisin A, inhibited cell growth in a concentration-dependent manner, which was associated with the induction of G1 arrest of the cell cycle. G1 arrest induced by gomisin N was correlated with down-regulation of cyclin E, cyclin-dependent kinase (Cdk) 2 and Cdk4, and a concomitant up-regulation of Cdk inhibitors such as p16 (INK4A) and p21 (WAF1/CIP1). Furthermore, gomisin N inhibited phosphorylation of retinoblastoma protein (pRB) and p130, and expression of transcription factor E2Fs. The results indicated that growth inhibition by gomisin N is related to cell cycle arrest at G1 in U937 cells and these findings suggest that gomisin N may be a useful chemotherapeutic agent.

Selection of Biofilter Support for Removing MEK (MEK 제거를 위한 바이오필터용 담체의 선택)

  • Jeong Gwi-Taek;Lee Gwang-Yeon;Lee Kyoung-Min;Sunwoo Chang-Shin;Lee Woo-Tae;Jung Seong-Ho;Cha Jin-Myoung;Jang Young-Seon;Park Don-Hee
    • KSBB Journal
    • /
    • v.21 no.1 s.96
    • /
    • pp.34-41
    • /
    • 2006
  • The aim of this study is the development of biological removal process of methyl ethyl ketone (MEK) in odor gas, which is generated from the waste food recycling process. To develop the removal process of odor gas, MEK, the selection of proper biofilter support was carried out. When the biofilter equipment was passed by synthetic odor gas composed of 250 ppm of MEK, the maximum removal was achieved to $586.6g-MEK/m^3\;hr$ for polypropylene fibril as support. Under the same experimental conditions, the maximum removal in polyurethane support was obtained to $359.7 g-MEK/m^3\;hr$. Finally, the maximum removal in volcanic stone support was $56.2g-MEK/m^3\;hr$.

Feasibility of Optoelectronic Neural Stimulation Shown in Sciatic Nerve of Rats (흰쥐의 좌골 신경 자극을 통한 광전 자극의 가능성에 대한 연구)

  • Kim Eui tae;Oh Seung jae;Baac Hyoung won;Kim Sung june
    • Journal of Biomedical Engineering Research
    • /
    • v.25 no.6
    • /
    • pp.611-615
    • /
    • 2004
  • A neural prostheses can be designed to permit stimulation of specific sites in the nervous system to restore their functions, lost due to disease or trauma. This study focuses on the feasibility of optoelecronic stimulation into nervous system. Optoelectronic stimulation supplies, power and signal into the implanted optical detector inside the body by optics. It can be effective strategy especially on the retinal prosthesis, because it enables the non-invasive connection between the external source and internal detector through natural optical window 'eye'. Therefore, we designed an effective neural stimulating setup by optically based stimulation. Stimulating on the sciatic nerve of a rat with proper depth probe through optical stimulation needs higher ratio of current spreading through the neural surface, because of high impedance of neural interface. To increase the insertion current spreading into the neuron, we used a parallel low resistance compared to load resistance organic interface and calculated the optimized outer parallel resistance for maximum insertion current with the assumption of limited current by photodiode. Optimized outer parallel resistance was at a range of 500Ω-700Ω and a current was at a level between 580uA and 650uA. Stimulating current efficiency from initial photodiode induced current was between 47.5 and 59.7%. Various amplitude and frequency of the optical stimulation on the sciatic nerve showed the reliable visual tremble, and the action potential was also recorded near the stimulating area. These result demonstrate that optoelectronic stimulation with no bias can be applied to the retinal prosthesis and other neuroprosthetic area.

A Study of Roughness Measurement of Rock Discontinuities Using a Confocal Laser Scanning Microscope (콘포컬 레이저 현미경을 이용한 불연속면의 거칠기 측정 연구)

  • Byung Gon Chae;Jae Yong Song;Gyo Cheol Jeong
    • The Journal of Engineering Geology
    • /
    • v.12 no.4
    • /
    • pp.405-419
    • /
    • 2002
  • Fracture roughness of rock specimens is observed by a new confocal laser scanning microscope (CLSM; Olympus OLS1100). The wave length of laser is 488 nm, and the laser scanning is managed by a light polarization method using two galvano-meter scanner mirrors. The function of laser reflection auto-focusing enables us to measure line data fast and precisely. The system improves resolution in the light axis (namely z) direction because of the confocal optics. Using the CLSM, it is Possible to measure a specimen of the size up to $10{\;}{\times}{\;}10{\;}cm$ which is fixed on a specially designed stage. A sampling is managed in a spacing $2.5{\;}\mu\textrm{m}$ along x and y directions. The highest measurement resolution of z direction is $10{\;}\mu\textrm{m}$, which is more accurate than other methods. Core specimens of coarse and fine grained granite are provided. Fractures are artificially maneuvered by a Brazilian test method. Measurements are performed along three scan lines on each fracture surface. The measured data are represented as 2-D and 3-D digital images showing detailed features of roughness. Line profiles of the coarse granites represent more frequent change of undulation than those of the fine granite. Spectral analyses by the fast Fourier transform (FFT) are performed to characterize the roughness data quantitatively and to identify influential frequency of roughness. The FFT results suggest that a specimen loaded by large and low frequency energy tends to have high values of undulation change and large wave length of fracture roughness.

The Spermatogenesis of Cichlasoma managuensis, Cichlidae, Teleost (경골어류 시클리드과 Cichlasoma managuensis의 정자형성과정)

  • Lee, Kyu-Jae;Chang, Byung-Soo;Teng, Yung-Chien;Kim, Seok;Song, Mi-Sook;Joo, Kyung-Bok;Kim, Dong-Heui
    • Applied Microscopy
    • /
    • v.39 no.3
    • /
    • pp.219-226
    • /
    • 2009
  • The ultrastructure of spermatogenesis and sperm in Cichlasoma managuensis belonging to Cichlidae was investigated by light and electron microscopes. The testis of C. managuensis contained numerous testicular cysts, and spermatogenesis was synchronized in these testicular cysts. In the case of spermatogonia, the nucleus was comparatively large ellipsoidal, and mitochondria showed a marked development. The size of primary spermatocyte was smaller than that of spermatogonia, and that of secondary spermatocyte was smaller than that of primary spermatocyte. The chromatin of spermatocyte was highly condensed according to their development. The nucleus with electron-dense was round shape. In spermiogenesis, flagella started to be formed and chromatin was more condensed. The mitochondria were rearranged in a middle piece. The sperm was formed by loss of cytoplasm. The head of mature sperm was a spherical shape and had not acrosome. The microtubules of flagella were arranged 9+2 structure. Also, the tail of sperm have lateral fins.

Effects of the strain on the threshold current density in InGaAs/InGaAsP multiple quantum well lasers (InGaAs/InGaAsP 다중양자우물 레이저에서 변형이 문턱전류밀도에 미치는 효과)

  • 김동철;유건호;주흥로;김형문;김태환
    • Korean Journal of Optics and Photonics
    • /
    • v.9 no.2
    • /
    • pp.111-116
    • /
    • 1998
  • Thirteen InGaAs/InGaAsP separate-confinement heterostructure multiple quantum well lasers were designed such that the strain in the active layer from 0.9% compressive strain to 1.4% tensile, and their threshold current density was caluculated to see the effects of strain on the threshold current density. The well width was adjusted such that the bandgap of the quantum well is 1.55 ${\mu}{\textrm}{m}$, For the calculation of the band structure and transition matrix element needed for the gain calculation, a block diagonalized 8$\times$8 second-order $\to{k}.\to{p}$ Hamiltonian was used to incorporate the conduction band nonparabolicity and the valence band mixing. The threshold current density shows discontinuity at 0.4% tensile strain where the first heavy-hole subband and the first light-hole subband cross and at 0.5% tensile strain where the second conduction subband begins to exist. The threshold current density at room temperature has a maximum around these 0.4-0.5% tensile strains, and as strain varies in either direction it decreases first and then increases a little after a local minimum. This calculated trend is consistent with the other reported experimental results. We discussed the results of this calculation in comparison with other theoretical or experimental papers on the effect of strain.

  • PDF

Multiphonon relaxation and frequency upconversion of $Er^{3+}$ ions in heavy metal oxide glasses ($Er^{3+}$첨가 중금속 산화물 유리의 다중포논 완화와 주파수 상향 전이 현상)

  • Choi, yong-Gyu;Kim, Kyong-Hon;Heo, Jong
    • Korean Journal of Optics and Photonics
    • /
    • v.9 no.4
    • /
    • pp.221-226
    • /
    • 1998
  • Ternary heavy metal oxide glasses in the $PbO-Bi_2O_3-Ga_2O_3$ system doped with $Er_2O_3$ were prepared and their spectroscopic properties, such as radiative transition probability, calculated and measured radiative lifetimes and cross-sections of 1.5 $\mu\textrm{m}$ and 2.7 $\mu\textrm{m}$ emissions were analyzed. Enhanced quantum efficiencies of some electronic transitions were evident mainly because of the low vibrational phonon energy ($~500cm^{-1}$) inherent in the host glasses. This seems to be the main reason for obtaining the 2.7 $\mu\textrm{m}$ luminescence which is normally quenched in the conventional oxide glasses. In addition, green and red fluorescence emissions were observed through the frequency upconversion processes of the 798 nm excitation. Non-radiative transition due to the multiphonon relaxation is a dominant lifetime-shortening mechanism in the 4f-4f transitions in $Er^{3+}$ ion except for the $^4S_{3/2}{\rightarrow}^4I_{15/2}$ transition where a non-radiative transfer to band-gap excitation of the host glasses is dominant. Melting of glasses under an inert gas atmosphere and (or) addition of the typical glass-network former into glasses is necessary in order to enhance the quantum efficiency of the transition.

  • PDF

One dimensional inhomogeneous aperture modulation effects on the MTF of optical system II (일차원적 비균일 개구변조시 광학계의 최적상면 MTF에 미치는 영향)

  • 홍경희
    • Korean Journal of Optics and Photonics
    • /
    • v.9 no.5
    • /
    • pp.277-281
    • /
    • 1998
  • One dimensional inhomogeneous aperture modulation effects on the MTF of optical system was investigated. The lens under test was a doublet made in Korea. It has 10 mm effective diameter, 87.8 mm effective focal length. The ray-fans and spot diagrams were calculated and presented on the picture for on-axis and off-axis (field of view, $1^{\circ}$ and $2^{\circ}$). Aperture modulation was carried out by positioning a aperture modulator close contacter with the lens under test. We bought two modulators from Edmud Company in U.S.A. One was linear type and the other was stepped type. The MTFs were measured on the best of focus for each modulated aperture where the MTF has the highest value for 60 line/mm and were compared with one another. For on-axis, the MTFs of some modulated apertures had higher values than the MTF of unmodulated aperture in the high frequency region. In the case of off-axis, at the field of view $1^{\circ}$, the MTF values of some modulated aperture are improved prominently and some other one are disimproved. At the field of view $2^{\circ}$ most of the MTFs of modulated apertures had lower values than the MTF of unmodulated aperture except the MTFs of linear and inverse linear type aperture in the high frequency area. But the values of MTFs in high frequency region were too low for actual use.

  • PDF

Proposan and Analysis of DR(Distributed Reflector)-LD/EA(electro-absorption)­Modulator Integrated Device (분포반사기 레이저 다이오드와 광흡수 변조기가 집적된 소자의 제안 및 해석)

  • 권오기;심종인
    • Korean Journal of Optics and Photonics
    • /
    • v.9 no.5
    • /
    • pp.333-341
    • /
    • 1998
  • The novel integrated device, 1.55 ${\mu}{\textrm}{m}$ DR-LD(distrbuted reflector laser diode) integrated EA-MOD (electro-absorption modulator) as light source, is proposed to improve the device yield and its operational performances. This device can be easily fabricated by the selective MOVPE technique and its fabrication processes are almost the same as the reported 1.55 ${\mu}{\textrm}{m}$ DFB-LD(distributed feedback laser diode) integrated EA-MOD except the asymmetric gratings. The static and dynamic properties are investigated simultaneously by solving the transfer matrix method for light propagation, the time-dependent rate equation for carrier change and schr$\"{o}$dinger equation for QCSE (Quantum-Confined Stark Effect). The performances of the proposed device such as output power, chirp, and extinction ratio are compared with those of DFB-LD integrated EA-MOD. Under 10Gb/s NRZ modulation, we obtain that DR-LD integrated EA-MOD. is 30% higher in output power on the on-state, about 50% lower in chirp, and slightly larger in extinction ratio than DFB-LD integrated EA-MOD.-MOD.

  • PDF

Polymer Optical Microring Resonator Using Nanoimprint Technique (나노 임프린트 기술을 이용한 폴리머 링 광공진기)

  • Kim, Do-Hwan;Im, Jung-Gyu;Lee, Sang-Shin;Ahn, Seh-Won;Lee, Ki-Dong
    • Korean Journal of Optics and Photonics
    • /
    • v.16 no.4
    • /
    • pp.384-391
    • /
    • 2005
  • A polymer optical microring resonator, which is laterally coupled to a straight bus waveguide, has been proposed and demonstrated using a nanoimprint technique. The propagation loss of the ring waveguide and the optical power coupling between the ring and bus waveguides was calculated by using a beam propagation method, then the dependence of the device performance on them was investigated using a transfer matrix method. We have especially introduced an imprint stamp incorporating a smoothing buffer layer made of a silicon nitride thin film. This layer played an efficient role in improving the sidewall roughness of the waveguide pattern engraved on the stamp and thus reducing the scattering loss. As a result the overall Q factor of the resonator was greatly increased. Also it reduced the gap between the ring and bus waveguides effectively to enhance the coupling between them, without relying on the direct writing method based on an e-beam writer. As for the achieved device performance at the wavelength of 1550 nm, the quality factor, the extinction ratio, and the free spectral range were ~103800, ~11 dB, and 1.16 m, respectively.