• Title/Summary/Keyword: optical sensor

Search Result 2,129, Processing Time 0.029 seconds

Effects of Oscillating Flow on the Dynamic Behavior of an Artificial Sensory Hair (인공 감각모의 동적 거동에 미치는 진동유동의 영향)

  • Park, Byung-Kyu;Lee, Joon-Sik
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.35 no.8
    • /
    • pp.847-853
    • /
    • 2011
  • Filiform hairs that respond to movements of the surrounding medium are the mechanoreceptors commonly found in arthropods and vertebrates. The hairs function as a sensory system for perceiving information produced by prey, predators, or conspecifics. A mathematical model is proposed, and the parametric analyses for the response of artificial filiform hair are conducted to design and predict the performance of a microfabricated device. The results for the Cytop hair, one of the most popular polymer optical fibers (POFs), show that the fundamental mode has a dominant effect on the hair behavior in an oscillating medium flow. The dynamic behavior of sensory hair is also dependent on the physical dimensions such as length and diameter. It is found that the artificial hair with a high elastic modulus does not show a resonance in the biologically important frequency range.

Endpoint Detection Using Both By-product and Etchant Gas in Plasma Etching Process (플라즈마 식각공정 시 By-product와 Etchant gas를 이용한 식각 종료점 검출)

  • Kim, Dong-Il;Park, Young-Kook;Han, Seung-Soo
    • Journal of IKEEE
    • /
    • v.19 no.4
    • /
    • pp.541-547
    • /
    • 2015
  • In current semiconductor manufacturing, as the feature size of integrated circuit (IC) devices continuously shrinks, detecting endpoint in plasma etching process is more difficult than before. For endpoint detection, various kinds of sensors are installed in semiconductor manufacturing equipments, and sensor data are gathered with predefined sampling rate. Generally, detecting endpoint is performed using OES data of by-product. In this study, OES data of both by-product and etchant gas are used to improve reliability of endpoint detection. For the OES data pre-processing, a combination of Signal to Noise Ratio (SNR) and Principal Component Analysis (PCA),are used. Polynomial Regression and Expanded Hidden Markov model (eHMM) technique are applied to pre-processed OES data to detect endpoint.

A Study on the Development of leisure boat's Hull Stress Monitoring System using AWG (광섬유센서를 이용한 레저선박의 선체구조모니터링시스템 개발에 관한 연구(I))

  • Kang, Nam-Seon;Kim, Hyen-Woo
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.17 no.3
    • /
    • pp.269-274
    • /
    • 2011
  • The purpose of hull stress monitoring system(HSMS) is to lead hull structure to be safer at lower cost. We proposed a hull stress monitoring system for leisure boats using fiber-optic bragg grating(FBG) strain sensor. Fiber optic sensors are well suited for structure monitoring system, due to their ability to withstand harsh environments, immunity to electromagnetic interference, and reduce cabling installation cost when employing wavelength multiplexing. This paper presents an overview of current research and design of hull stress monitoring system for leisure boats.

Image Map Generation using the Airship Photogrammetric System (비행선촬영시스템을 이용한 영상지도 제작)

  • 유환희;제정형;김성삼
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.20 no.1
    • /
    • pp.59-67
    • /
    • 2002
  • Recently, much demand of vector data have increased rapidly such as a digital map instead of traditional a paper map and the raster data such as a high-resolution orthoimage have been used for many GIS application with the advent of industrial high-resolution satellites and development of aerial optical sensor technologies. Aerial photogrammetric technologies using an airship can offer cost-effective and high-resolution color images as well as real time images, different from conventional remote sensing measurements. Also, it can acquire images easily and its processing procedure is short and simple relatively. On the other hand, it has often been used for the production of a small-scale land use map not required high accuracy, monitoring of linear infrastructure features through mosaicking strip images and construction of GIS data. Through this study, the developed aerial photogrammetric system using the airship expects to be applied to not only producing of scale 1:5, 000 digital map but also verifying, editing, and updating the digital map which was need to be reproduced. Further more, providing the various type of video-images, it expects to use many other GIS applications such as facilities management, scenery management and construction of GIS data for Urban area.

The Characteristics of High Temperature Crystallized Poly-Si for Thin Film Transistor Application (박막트랜지스터 응용을 위한 고온 결정화된 다결정실리콘의 특성평가)

  • 김도영;심명석;서창기;이준신
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.53 no.5
    • /
    • pp.237-241
    • /
    • 2004
  • Amorphous silicon (a-Si) films are used in a broad range of solar cell, flat panel display, and sensor. Because of the greater ease of deposition and lower processing temperature, thin films are widely used for thin film transistors (TFTs). However, they have lower stability under the exposure of visible light and because of their low field effect mobility ($\mu$$_{FE}$ ) , less than 1 c $m^2$/Vs, they require a driving IC in the external circuits. On the other hand, polycrystalline silicon (poly-Si) thin films have superiority in $\mu$$_{FE}$ and optical stability in comparison to a-Si film. Many researches have been done to obtain high performance poly-Si because conventional methods such as excimer laser annealing, solid phase crystallization and metal induced crystallization have several difficulties to crystallize. In this paper, a new crystallization process using a molybdenum substrate has been proposed. As we use a flexible substrate, high temperature treatment and roll-to-roll process are possible. We have used a high temperature process above 75$0^{\circ}C$ to obtain poly-Si films on molybdenum substrates by a rapid thermal annealing (RTA) of the amorphous silicon (a-Si) layers. The properties of high temperature crystallized poly-Si studied, and poly-Si has been used for the fabrication of TFT. By this method, we are able to achieve high crystal volume fraction as well as high field effect mobility.

Growth and effect of thermal annealing for ZnIn2Se4 single crystalline thick film by hot wall epitaxy (Hot Wall Epitaxy (HWE)법에 의한 ZnIn2Se4 단결정 후막 성장과 열처리 효과)

  • Hong, Myung-Seuk;Hong, Kwang-Joon
    • Journal of Sensor Science and Technology
    • /
    • v.17 no.6
    • /
    • pp.437-446
    • /
    • 2008
  • Single crystalline ${ZnIn_2}{Se_4}$ layers were grown on thoroughly etched semi-insulating GaAs (100) substrate at $400^{\circ}C$ with hot wall epitaxy (HWE) system by evaporating ${ZnIn_2}{Se_4}$ source at $630^{\circ}C$. The crystalline structure of the single crystalline thick films was investigated by the photoluminescence (PL) and Double crystalline X-ray rocking curve (DCRC). The carrier density and mobility of ${ZnIn_2}{Se_4}$ single crystalline thick films measured from Hall effect by van der Pauw method are $9.41{\times}10^{16}cm^{-3}$ and $292cm^2/V{\cdot}s$ at 293 K, respectively. The temperature dependence of the energy band gap of the ${ZnIn_2}{Se_4}$ obtained from the absorption spectra was well described by the Varshni's relation, $E_g(T)$=1.8622 eV-$(5.23{\times}10^{-4}eV/K)T^2$/(T+775.5 K). After the as-grown ${ZnIn_2}{Se_4}$ single crystalline thick films was annealed in Zn-, Se-, and In-atmospheres, the origin of point defects of ${ZnIn_2}{Se_4}$ single crystalline thick films has been investigated by the photoluminescence (PL) at 10 K. The native defects of $V_{Zn}$, $V_{Se}$, $Zn_{int}$, and $Se_{int}$ obtained by PL measurements were classified as a donors or acceptors type. And we concluded that the heat-treatment in the Se-atmosphere converted ${ZnIn_2}{Se_4}$ single crystalline thick films to an optical p-type. Also, we confirmed that In in ${ZnIn_2}{Se_4}$/GaAs did not form the native defects because In in ${ZnIn_2}{Se_4}$ single crystalline thick films existed in the form of stable bonds.

Characteristics of Se/CdS Heterojunction Fabricated by EBE Method (EBE법으로 제작한 Se/CdS 이종접합의 특성)

  • Park, Gye-Choon;Cho, Jae-Cheol;Yoo, Yong-Tek
    • Journal of Sensor Science and Technology
    • /
    • v.2 no.1
    • /
    • pp.87-94
    • /
    • 1993
  • CdS and Se thin films were deposited on slide glass by EBE method respectively and surface morphology, crystal structure, electrical and optical properties were investigated by substrate temperature and annealing. The deposited CdS film was well fabricated with cubic structure at substrate temperature of $150^{\circ}C$. Se film was deposited with noncrystal structure until substrate temperature of $100^{\circ}C$, but Se film was grown with monoclinic structure at substrate temperature of $150^{\circ}C$. And so, after annealing at $150^{\circ}C$ for 15min, noncrystalline Se was proved to be hexagonal structure. Finally, the maximum output of Se/CdS heterojunction at 5000 lux was 4 $mW/cm^{2}$ and maximum spectral sensitivity was represented at 585nm.

  • PDF

Automation of urine dipstick test by simultaneous scanning : A pilot study (요 스트립검사 자동화를 위한 동시 비교 스캔 기법 예비 연구)

  • Lee, Sang-Bong;Choi, Seong-Su;Lee, In-Kwang;Han, Jeong-Su;Kim, Wan-Seok;Kim, Wun-Jae;Cha, Eun-Jong;Kim, Kyung-Ah
    • Journal of Sensor Science and Technology
    • /
    • v.19 no.3
    • /
    • pp.169-175
    • /
    • 2010
  • Urinalysis is an important clinical test to diagnose urinary diseases, and dipstick method with visual inspection is widely applied in practice. Automated optical devices recently developed have disadvantages of long measurement time, big size and heavy weight, accuracy degradation with time, etc. The present study proposed a new computer scanning technique, in which the test strip and the standard chart were simultaneously scanned to remove any environmental artifacts, followed by automated differentiation with the minimum distance algorithm, leading to significant enhancement of accuracy. Experiments demonstrated an accuracy of 100 % in that all test results were identical with the human visual inspection. The present technique only uses a personal computer with scanner and shortens the test time to a great degree. The results are also stored and accumulated for later use which can be transmitted to remote locations through a network, thus could be easily integrated to any ubiquitous health care systems.

Measurement of Inertia of Turbocharger Rotor in a Passenger Vehicle (승용차용 터보과급기 로터의 관성모멘트 측정)

  • Chung, Jin Eun;Lee, Sangwoon
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.24 no.1
    • /
    • pp.33-38
    • /
    • 2016
  • The turbocharger is an essential component to realize the engine down-sizing. The moment of inertia of turbocharger rotor is an important parameter with respect to acceleration performance of the vehicle. It can be calculated from the CAD software based the geometry data and the material properties. But the accurate value of the inertia of turbocharger rotor must be measured through the experimental method. In this study, the measurement of moment of inertia of turbocharger rotor for 2.0 L spark-ignition engine was carried out. First, an experimental equipment using a trifilar method was designed and fabricated. Some optical devices, that is, photo sensor, counter, convex lens, etc, were used to increase the accuracy of the measurement. Second, error sensitivity for the equipment was analyzed. The error of period time and the radius can give big affects to the accuracy of the moment of inertia. When the amount of error of these two were each 1.0 %, maximum error of the moment of inertia was under 3.0 %. Third, the calibration for the equipment was performed using a calibration rotor which has similar shape to turbine rotor but simple. Calculated value from CAD software and measured one for the calibration rotor were compared. The total error of the equipment and the measurement is about 1.3 %. This result shows that the equipment can give the good result with resonable accuracy. Finally the moment of inertia of the turbine rotor and compressor wheel were measured. The coefficient of variations, the ratio of standard deviation to mean value, were reasonably small at 0.57 % and 0.73 % respectively. Therefore this equipment is suitable for the measurement of the moment of inertia of the turbine rotor and compressor wheel.

A Study on Safety, Performance and Clinical effectiveness Test Guideline of Versatile Ophthalmic Laser System (다목적 안과용 레이저 시스템 안전성 성능평가 및 임상적 유효성평가 가이드라인 수립을 위한 연구)

  • Kim, You Rim;Yu, Woo Jin;Park, Ho Joon;Jang, Won Seuk
    • Journal of Biomedical Engineering Research
    • /
    • v.40 no.6
    • /
    • pp.250-259
    • /
    • 2019
  • Ophthalmic Laser System is widely used in Selective Laser Trabeculoplasty of Open Angle Glaucoma and Ocular Hypertension. Versatile ophthalmic laser system is a medical device with technology that checks the condition of the treatment area by irradiating a continuous laser pulse on the treatment area, and monitoring the microbubble reaction caused by the temperature increase of the melanosome through the ultrasonic signal and the optical signal sensor. It performs selective laser treatment without damaging the photoreceptor by controlling the wavelength of the laser when microbubbles are detected. This study aims to suggest a guideline for evaluating safety, performance and clinical effectiveness of Versatile Ophthalmic Laser System in accordance with the growing technology. International Standards, Regulations, and Clinical Trial Protocols were investigated and analyzed for this study. As a result of this study, the safety, performance and clinical effectiveness test guideline for Versatile Ophthalmic Laser System were proposed. This guideline will ensure the safety and efficacy of Medical device, and furthermore it is expected to be able to promote the development of technology development by supporting a clinical trial plan.