• 제목/요약/키워드: optical scanning

Search Result 1,613, Processing Time 0.029 seconds

Observation of Morphology, Surface potential and Optical Transmission Images in the Thin Film Using SPM (SPM을 이용한 박막의 모폴로지, 표면전위와 광투과이미지 관찰)

  • Shin, Hoon-Kyu;Kwon, Young-Soo
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2000.05b
    • /
    • pp.327-330
    • /
    • 2000
  • The scanning Maxwell-stress microscopy (SMM) is a dynamic noncontact electric force microscopy that allows simultaneous access to the electrical properties of molecular system such as surface potential, surface charge, dielectric constant and conductivity along with the topography. The Scanning near-field optical / atomic force microscopy (SNOAM) is a new tool for surface imaging which was introduced as one application of the atomic force microscope (AFM). Operated with non-contact forces between the optical fiber and sample as well as equipped with the piezoscanners, the instrument reports on surface topology without damaging or modifying the surface for measuring of optical characteristic in the films. We report our recent results of its application to nanoscopic study of domain structures and electrical functionality in organic thin films by SMM. Furthermore, we have illustrated the SNOAM image in obtaining the merocyanine dye films as well as the optical image.

  • PDF

Binocular Holographic Three-Dimensional Imaging System Using Optical Scanning Holography (광 스캐닝 홀로그래피를 이용한 양안식 3차원 홀로그래픽 영상 시스템)

  • Kim, You Seok;Kim, Taegeun
    • Korean Journal of Optics and Photonics
    • /
    • v.26 no.5
    • /
    • pp.249-254
    • /
    • 2015
  • In this paper we propose a binocular holographic three-dimensional (3D) imaging system using optical scanning holography. To realize a binocular 3D holographic imaging system, we could acquire the complex holograms of a real object after designing a holographic display system based on interpupillary distance and pupil size, and these holograms could be optically reconstructed following numerical signal processing with an amplitude spatial light modulator. The proposed binocular 3D holographic imaging system using optical scanning holography was verified experimentally.

3-Dimensional Profile Measurement of Free-Formed Surfaces by Slit Beam Scanning Topography (슬릿광 주사방법에 의한 자유곡면의 삼차원형상 측정)

  • 박현구;김승우;박준호
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.17 no.5
    • /
    • pp.1202-1207
    • /
    • 1993
  • An optical method of slit beam scanning topography is presented for the 3-dimensional profile measurement of free-formed surfaces. A slit beam of laser is projected in a scanning mode and its illuminated trajectory on the object is captured by using a CCD camera. The 3-dimensional coordinates of the trajectory is then computed by using the given geometry between the slit beam and the camera, so that the whole surface profile of the object can be obtained in a successive manner. Detailed optical principles are described with special emphasis to lateral are discussed to demonstrate the measuring performances of the slit beam scanning topography proposed in this study.

A Technique to Improve the Readability of Ancient Inscription by Using Optical Triangulation Measurement Principle (광삼각법 측정 원리를 이용한 금석문 가독성 향상 방법)

  • Lee, Geun-Ho;Ko, Sun-Woo;Choi, Won-Ho
    • Journal of Information Technology Services
    • /
    • v.11 no.sup
    • /
    • pp.103-111
    • /
    • 2012
  • In epigraph field to study ancient scripts, alternative readability improvement technologies have been developed to replace existing rubbing method which has low resolution and causes surface pollution of heritages from the viewpoints of extraction process and used materials. Recently many methods which are based on analysis of pixel data for extracting outlines of the specific image have been developed with advancement of image processing techniques. But these methods are not applicable and the results are not satisfied in the damaged inscriptions which are weathered by wind and rain for a long time and in the narrowed one. In this paper laser scanning techniques which uses optical triangulation measurement principle are developed to minimize scanning error. The proposed techniques are consisted of 3 parts:(1) the understanding of optical triangulation measurement principle to find scanning guideline (2) determinations of points interval, scanning distance and scanning angle to guarantee scanning data quality (3) identification of valid point data area which will be used in registration process. The proposed character identification method contributed in decoding an ancient inscription on SeukBingGo in Kyungju.

Implementation of Cost-effective Common Path Spectral Domain Free-hand Scanning OCT System

  • Shoujing Guo;Xuan Liu;Jin U. Kang
    • Current Optics and Photonics
    • /
    • v.7 no.2
    • /
    • pp.176-182
    • /
    • 2023
  • Optical coherence tomography (OCT) is being developed to guide various ophthalmic surgical procedures. However, the high cost of the intraoperative OCT system limits its availability mostly to the largest hospitals and healthcare systems. In this paper, we present a design and evaluation of a low-cost intraoperative common-path free-hand scanning OCT system. The lensed fiber imaging probe is designed and fabricated for intraocular use and the free-hand scanning algorithm that could operate at a low scanning speed was developed. Since the system operates at low frequencies, the cost of the overall system is significantly lower than other commercial intraoperative OCT systems. The assembled system is characterized and shows that it meets the design specifications. The handheld OCT imaging probe is tested on multilayer tape phantom and ex-vivo porcine eyes. The results show that the system could be used as an intraoperative intraocular OCT imaging device.

In Situ Fluorescence Optical Detection Using a Digital Micromirror Device (DMD) for 3D Cell-based Assays

  • Choi, Jong-Ryul;Kim, Kyujung;Kim, Donghyun
    • Journal of the Optical Society of Korea
    • /
    • v.16 no.1
    • /
    • pp.42-46
    • /
    • 2012
  • We have developed a fluorescence optical detection system using a digital micromirror device (DMD) for monitoring 3D cell culture matrices in situ. Full 3D imaging with fast scanning speed was implemented by the combined action of a DMD and a motorized stage. Imaging results with fluorescent microbeads measure the minimum axial resolution of the system as $6.3{\mu}m$, while full 1-mm scanning through 3D alginate-based matrix was demonstrated. For cell imaging, improved images were obtained by removing background fluorescence although the scanning distance was reduced because of low intracellular fluorescence efficiency. The system is expected to be useful to study various dynamics and behaviors of 3-dimensionally cultured cells in microfluidic systems.

Measurement of surface plasmon using near-field scanning optical microscope (근접장 주사 광학 현미경을 이용한 표면 플라즈몬의 측정)

  • 고선아;이관수;박승룡;윤재웅;송석호;김필수;오차환
    • Korean Journal of Optics and Photonics
    • /
    • v.15 no.1
    • /
    • pp.51-55
    • /
    • 2004
  • Surface plasmons (SPs) are charge density oscillations that propagate along an interface between a dielectric and metal. In this paper, the electric field of SPs and the intereference of two SPs are observed by using Near-field Scanning Optical Microscope (NSOM). The excitation condition of SPs is changed as the optical tip approaches the metal surface, because the excitation condition of SPs is very sensitive to surface structures. To measure the microscope field of SPs, the distance between metal surface and optical tip must contain a specific interval.

Evaluation of the Speckle Noise in Optical Scanning Holography (광 스캐닝 홀로그래피와 스펙클 잡음에 의한 오염도 평가)

  • Kim, You Seok;Kim, Taegeun
    • Korean Journal of Optics and Photonics
    • /
    • v.25 no.3
    • /
    • pp.142-145
    • /
    • 2014
  • In this paper we record the complex hologram of a real object with optical scanning holography (OSH). We reconstruct the complex hologram using a numerical process, and then we evaluate the degree of contamination by speckle noise between the reconstruction of the complex hologram and the image captured by a CCD camera. We use the contrast of the speckle pattern for quantitative evaluation.

Auto-focus of Optical Scanning Holographic Microscopy Using Partial Region Analysis (광 스캐닝 홀로그램 현미경에서 부분 영역 해석을 통한 자동 초점)

  • Kim, You-Seok;Kim, Tae-Geun
    • Korean Journal of Optics and Photonics
    • /
    • v.22 no.1
    • /
    • pp.10-15
    • /
    • 2011
  • In this paper, we propose an auto-focusing algorithm which extracts a depth parameter by analyzing a selected part of a hologram, and we use experimental results to show that the algorithm is practical. First, we record a complex hologram using Optical Scanning Holography. Next we select some part of hologram and extract depth information through Gaussian low pass filtering, synthesizing a real-only hologram, power fringe-adjusted filtering and inverting to a new frequency axis. Finally, we reconstruct the hologram automatically using the extracted depth location.