• Title/Summary/Keyword: optical model potential

Search Result 99, Processing Time 0.027 seconds

Swelling Controlled Delivery of Antibiotic from a Hydrophilic Macromolecular Matrix with Hydrophobic Moieties

  • Shukla, Sandeep;Bajpai, Anil Kumar;Bajpai, Jaya
    • Macromolecular Research
    • /
    • v.11 no.4
    • /
    • pp.273-282
    • /
    • 2003
  • A hydrophilic macromolecular network containing hydrophobic moieties has been prepared by free radical copolymerization of acrylamide and styrene in the presence of poly(vinyl alcohol) (PVA) and its potential as controlled drug delivery carrier was evaluated with tetracycline as a model antibiotic drug. The amount of drug was assayed spectrophotometrically. The network was characterized by optical microscopy, infra-red spectroscopy and structural parameters such as average molecular weight between cross1inks ($M_c$), cross1ink density (q) and number of elastically effective chains ($V_e$) were evaluated. It was found that with increasing concentration of PVA, ST and MBA in the hydrogel, the release rate initially increases but after definite concentrations of the above components the release rate falls. In the case of AM, release rate constantly decreases with increasing AM concentration in the hydrogel.

Analysis of Transmission Infrared Laser Bonding for Micro Polymer Devices (폴리머 마이크로 칩에 대한 레이저 투과 마이크로 접합)

  • Kim, Ju-Han;Sin, Gi-Hun
    • Proceedings of the KWS Conference
    • /
    • 2005.06a
    • /
    • pp.43-45
    • /
    • 2005
  • A precise bonding technique, transmission laser bonding using energy transfer, for polymer micro devices is presented. The irradiated IR laser beam passes through the transparent part and absorbed on the opaque part. The absorbed energy is converted to heat and bonding takes place. In order to optimize the bonding quality, the temperature profile on the interface must be obtained. Using optical measurements of the both plates, the absorbed energy can be calculated and heat transfer model was applied for obtaining the transient temperature profile. The transmission laser bonding has a potential in the local precise bonding in MEMS or Lab-on-a-chip.

  • PDF

A BIPOLAR PLANETARY NEBULA NGC 6537: PHOTOIONIZATION OR SHOCK HEATING?

  • HYUNG SIEK
    • Journal of The Korean Astronomical Society
    • /
    • v.32 no.1
    • /
    • pp.55-63
    • /
    • 1999
  • NGC 6537 is an extremely high excitation bipolar planetary nebula. It exhibits a huge range of excitation from lines of [N I] to [Si VI]or [Fe VII], i.e. from neutral atoms to atoms requiring an ionization potential of $\~$167eV. Its kinematical structures are of special interest. We are here primarily concerned with its high resolution spectrum as revealed by the Hamilton Echelle Spectrograph at Lick Observatory (resolution $\~0.2{\AA}$) and supplemented by UV and near-UV data. Photoionization model reproduces the observed global spectrum of NGC 6537, the absolute H$\beta$ flux, and the observed visual or blue magnitude fairly well. The nebulosity of NGC 6537 is likely to be the result of photo-ionization by a very hot star of $T_{eff} \~ 180,000 K$, although the global nebular morphology and kinematics suggest an effect by strong stellar winds and resulting shock heating. NGC 6537 can be classified as a Peimbert Type I planetary nebula. It is extremely young and it may have originated from a star of about 5 $M_{\bigodot}$.

  • PDF

Analysis of Transmission Infrared Laser Bonding for Polymer Micro Devices (폴리머 마이크로 장치에 대한 레이저 투과 마이크로 접합)

  • Kim, Joo-Han;Shin, Ki-Hoon
    • Journal of Welding and Joining
    • /
    • v.23 no.5
    • /
    • pp.55-60
    • /
    • 2005
  • A precise bonding technique, transmission laser bonding using energy transfer, for polymer micro devices is presented. The irradiated IR laser beam passes through the transparent part and absorbed on the opaque part. The absorbed energy is converted into heat and bonding takes place. In order to optimize the bonding quality, the temperature profile on the interface must be obtained. Using optical measurements of the both plates, the absorbed energy can be calculated. At the wavelength of 1100nm $87.5\%$ of incident laser energy was used for bonding process from the calculation. A heat transfer model was applied for obtaining the transient temperature profile. It was found that with the power of 29.5 mW, the interface begins to melt and bond each other in 3 sec and it is in a good agreement with experiment results. The transmission IR laser bonding has a potential in the local precise bonding in MEMS or Lab-on-a-chip applications.

Palmitoylpolysaccharide-coated Liposomes As A Potential Oral Drug Carrier (경구용 약물수송체로서의 팔미토일 치환 다당체로 코팅된 리포좀)

  • Hahn, Yang-Hee;Yi, Jung-Woo;Choi, Young-Wook
    • Journal of Pharmaceutical Investigation
    • /
    • v.24 no.2
    • /
    • pp.73-83
    • /
    • 1994
  • Applications of liposomes as a drug carrier for the oral delivery of poorly-absorbable macromolecular drugs have been limited, because of their instability in gastrointestinal environments including pH, bile salts, and digestive enzymes. Two polysaccharides, dextran(DX) and pullulan(PL), were introduced to the preformed liposomes in order to enhance the stability. Palmitoyl derivatives of polysaccharides, palmitoyldextran(PalDX) and palmitoylpullulan(PalPL), were synthesizd and introduced to the liposomes during preparation for the same purpose of stability. The effects of these polysaccharides coating were evaluated basically by physical properties of particle size distribution and optical microscopy, then compared with uncoated liposomes by the observations of both in vitro stability and in vovo absorption characteristics. The geometric mean diameters of polysaccharide-coated liposomes were greater than that of uncoated liposome, showing the outermost polysaccharide-coated layer under the optical microscopy. In vitro stabilities of uncoated or polysaccharides-coated liposomes were measured by turbidity changes in various pH buffer solutions containing sodium choleate as bile salts. While uncoated liposome was very sensitive to bile salts, polysaccharides-coated liposomes were stable in relatively higher concentrations of sodium choleate, giving the results of better stability of PalDX- and PalPL-coated liposomes than that of DX- and PL-coated liposomes. After liposomal encapsulation of acyclovir(ACV), an antiviral agent as a model drug, it has been administered orally to rats as dose of ACV 40 mg/kg. Plasma concentrations of ACV were assayed by HPLC and analyzed by model-independent pharmacokinetics. Pharmacokinetic parameters of Cmax, tmax, and [AUC] have been compared.

  • PDF

Simulation Studies for Noninvasive Optical Measurements of Blood-Scattering Changes in a Skin Model with a Large Blood Vessel

  • Zephaniah, Phillips V;Paik, Seung-ho;Nam, Jungyong;Chang, Ki Young;Jung, Young-Jin;Choi, Youngwoon;Lee, Joonhyung;Kim, Beop Min
    • Current Optics and Photonics
    • /
    • v.3 no.1
    • /
    • pp.46-53
    • /
    • 2019
  • Monte Carlo simulations were performed for a three-dimensional tissue model with and without an embedded large vessel, to understand how varying vessel geometry affects surface light distribution. Vessel radius was varied from 1 to 5 mm, and vessel depth from 2 to 10 mm. A larger difference in surface fluence rate was observed when the vessel's radius increased. For vessel depth, the largest difference was seen at a depth of approximately 4 mm, corresponding to human wrist region. When the vessel was placed at depths greater than 8 mm, very little difference was observed. We also tested the feasibility of using two source-detector pairs, comprising two detectors distinctly spaced from a common source, to noninvasively measure blood-scattering changes in a large vessel. High sensitivity to blood-scattering changes was achieved by placing the near detector closer to the source and moving the far detector away from the source. However, at longer distances, increasing noise levels limited the sensitivity of the two-detector approach. Our results indicate that the approach using two source-detector pairs may have potential for quantitative measurement of scattering changes in the blood while targeting large vessels near the human wrist region.

Delineation of Rice Productivity Projected via Integration of a Crop Model with Geostationary Satellite Imagery in North Korea

  • Ng, Chi Tim;Ko, Jonghan;Yeom, Jong-min;Jeong, Seungtaek;Jeong, Gwanyong;Choi, Myungin
    • Korean Journal of Remote Sensing
    • /
    • v.35 no.1
    • /
    • pp.57-81
    • /
    • 2019
  • Satellite images can be integrated into a crop model to strengthen the advantages of each technique for crop monitoring and to compensate for weaknesses of each other, which can be systematically applied for monitoring inaccessible croplands. The objective of this study was to outline the productivity of paddy rice based on simulation of the yield of all paddy fields in North Korea, using a grid crop model combined with optical satellite imagery. The grid GRAMI-rice model was used to simulate paddy rice yields for inaccessible North Korea based on the bidirectional reflectance distribution function-adjusted vegetation indices (VIs) and the solar insolation. VIs and solar insolation for the model simulation were obtained from the Geostationary Ocean Color Imager (GOCI) and the Meteorological Imager (MI) sensors of the Communication Ocean and Meteorological Satellite (COMS). Reanalysis data of air temperature were achieved from the Korea Local Analysis and Prediction System (KLAPS). Study results showed that the yields of paddy rice were reproduced with a statistically significant range of accuracy. The regional characteristics of crops for all of the sites in North Korea were successfully defined into four clusters through a spatial analysis using the K-means clustering approach. The current study has demonstrated the potential effectiveness of characterization of crop productivity based on incorporation of a crop model with satellite images, which is a proven consistent technique for monitoring of crop productivity in inaccessible regions.

A Study on the Factors Affecting the use of Optical Aids by the aged with Low Vision (저시력 노인의 시력보조기구 사용에 영향을 미치는 요인에 관한 연구)

  • Yeum, D.M.;Sim, M.Y.;Jung, S.S.
    • Journal of rehabilitation welfare engineering & assistive technology
    • /
    • v.8 no.3
    • /
    • pp.213-219
    • /
    • 2014
  • This study applied the data of 384 senior citizens over 65 years old having difficulties in everyday life, among the ageing research panel of Korea Labor Institute in 2000, due to their visual impairment in the final analysis to investigate factors affecting the use of vision aids by the aged with visual impairment. The analysis was based on the service usage Andersen-Newman model and the factors were classified into preceding factors, potential factors and desire factors. To examine the effects of each factors on the use of vision aids by the aged with visual impairment, logistic regression analysis was carried out. In the analysis results, the level of vision aids usage was shown to increase significantly with unemployed status and higher education level in the preceding factors, lower subjective stratum consciousness in the potential factors, and higher cognitive function in the desire factors. The limitation and implication of this study were suggested on the basis of the results.

  • PDF

Development of a Cost-Effective Tele-Robot System Delivering Speaker's Affirmative and Negative Intentions (화자의 긍정·부정 의도를 전달하는 실용적 텔레프레즌스 로봇 시스템의 개발)

  • Jin, Yong-Kyu;You, Su-Jeong;Cho, Hye-Kyung
    • The Journal of Korea Robotics Society
    • /
    • v.10 no.3
    • /
    • pp.171-177
    • /
    • 2015
  • A telerobot offers a more engaging and enjoyable interaction with people at a distance by communicating via audio, video, expressive gestures, body pose and proxemics. To provide its potential benefits at a reasonable cost, this paper presents a telepresence robot system for video communication which can deliver speaker's head motion through its display stanchion. Head gestures such as nodding and head-shaking can give crucial information during conversation. We also can assume a speaker's eye-gaze, which is known as one of the key non-verbal signals for interaction, from his/her head pose. In order to develop an efficient head tracking method, a 3D cylinder-like head model is employed and the Harris corner detector is combined with the Lucas-Kanade optical flow that is known to be suitable for extracting 3D motion information of the model. Especially, a skin color-based face detection algorithm is proposed to achieve robust performance upon variant directions while maintaining reasonable computational cost. The performance of the proposed head tracking algorithm is verified through the experiments using BU's standard data sets. A design of robot platform is also described as well as the design of supporting systems such as video transmission and robot control interfaces.

The Characteristics of Focused Ion Beam Utilized Silicon Mold Fabrication on the Micro/Nano Scale (집속이온빔을 이용한 마이크로/나노스케일에서의 실리콘 금형 가공 특성)

  • Kim, Heung-Bae;Noh, Sang-Lai
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.28 no.8
    • /
    • pp.966-974
    • /
    • 2011
  • The use of ion beams in the micro/nano scale is greatly increased by technology development. Especially, focused ion beams (FIBs) have a great potential to fabricate the device in sub micro scale. Nevertheless, FIB has several limitations, surface swelling in low ion dose regime, precipitation of incident ions, and the redeposition effect due to the sputtered atoms. In this research, we demonstrate a way which can be used to fabricate mold structures on a silicon substrate using FIBs. For the purpose of the demonstration, two essential subjects are necessary. One is that focused ion beam diameter as well as shape has to be measured and verified. The other one is that the accurate rotational symmetric model of ion-solid interaction has to be mathematically developed. We apply those two, measured beam diameter and mathematical model, to fabricate optical lenses mold on silicon. The characteristics of silicon mold fabrication will be discussed as well as simulation results.