• 제목/요약/키워드: optical measurement system

검색결과 1,154건 처리시간 0.031초

Research on a Method for the Optical Measurement of the Rifling Angle of Artillery Based on Angle Error Correction

  • Zhang, Ye;Zheng, Yang
    • Current Optics and Photonics
    • /
    • 제4권6호
    • /
    • pp.500-508
    • /
    • 2020
  • The rifling angle of artillery is an important parameter, and its determination plays a key role in the stability, hit rate, accuracy and service life of artillery. In this study, we propose an optical measurement method for the rifling angle based on angle error correction. The method is based on the principle of geometrical optics imaging, where the rifling on the inner wall of the artillery barrel is imaged on a CCD camera target surface by an optical system. When the measurement system moves in the barrel, the rifling image rotates accordingly. According to the relationship between the rotation angle of the rifling image and the travel distance of the measurement system, different types of rifling equations are established. Solving equations of the rifling angle are deduced according to the definition of the rifling angle. Furthermore, we added an angle error correction function to the method that is based on the theory of dynamic optics. This function can measure and correct the angle error caused by the posture change of the measurement system. Thus, the rifling angle measurement accuracy is effectively improved. Finally, we simulated and analyzed the influence of parameter changes of the measurement system on rifling angle measurement accuracy. The simulation results show that the rifling angle measurement method has high measurement accuracy, and the method can be applied to different types of rifling angle measurements. The method provides the theoretical basis for the development of a high-precision rifling measurement system in the future.

초점길이 및 왜곡수차 측정장치 제작 (Fabrication of the focal length and distortion measurement system)

  • 조현모
    • 한국광학회:학술대회논문집
    • /
    • 한국광학회 1990년도 제5회 파동 및 레이저 학술발표회 5th Conference on Waves and lasers 논문집 - 한국광학회
    • /
    • pp.82-86
    • /
    • 1990
  • A camera type optical bench system equipped with a lens collimator and an image analyzer is fabricated to measure the equivalent focal length and distortion of lenses. This system is automatized by the computer which controls stepping motors. A nodal slide optical bench system equipped with an off axis reflective collimator is fabricated and improved by using rotating arms and air bearing system. distortion measurement on a wide angle lens using the camera method and the nodal slide method is reported. Defocusing error in the distortion measurement with the nodal slide optical bench is analyzed and improved by iteration method to search the correct image point.

  • PDF

Measurement of Focal Length for Off-axis Optical Systems

  • Choe, Se-woon;Ryu, Jaemyung
    • Current Optics and Photonics
    • /
    • 제5권4호
    • /
    • pp.402-408
    • /
    • 2021
  • An off-axis system refers to an optical system in which the optical axis and normal vector at the vertex of each surface do not match. The most important specification in an optical system is its focal length. Among the various methods for measuring the focal length, the most suitable method for the off-axis system is the method that adopts magnification. However, head-mounted display (HMD) optics must be measured while considering the virtual image distance, which is not infinity owing to product characteristics. For the virtual image distance, a camera with a focusing function was used. By measuring HMD optics via this magnification method, the error generated in this measurement was 0.68% of the HMD's focal length, which is within the 1%-3% range of the conventionally permitted design error for the focal length allowed at the optical design stage. Therefore, it can be verified that the measurement accuracy of the method proposed in this study is sufficiently feasible in practice.

하트만 방법에 의한 광학면의 기상측정 (On-Machine Measurement of an Optical Surface by Hartmann Test)

  • 김용관;오창진;이응석;김옥현
    • 한국공작기계학회:학술대회논문집
    • /
    • 한국공작기계학회 2002년도 추계학술대회 논문집
    • /
    • pp.474-480
    • /
    • 2002
  • Aspheric optical lenses and mirrors are widely used in recent. It is more difficult to manufacture and measure the aspherical optics compared to conventional spherical ones. The interferometric optical test is common for the measurement of spherical optical surface. But the application of the interferometry to the measurement of aspheric surface is difficult because it needs a precise null corrector and very careful environmental conditions such as keeping constant temperature, humidity, atmospheric pressure and vibrations. To enhance productivity of optics manufacturing on-machine measurement and correction has been developed in this study. For practical applications, robustness of the measurement method to environments is more important. For the purpose an optical OMM(On-Machine Measurement) system has been developed using Shack-Hartmann test which has robustness to the environment. The wavefront has been reconstructed from the measured data using the primary aberration polynomial function by least square fitting. The measured result of the developed only system gives the maximum deviation only in 200 nm from the result measured by a commercial Fizeau interferometer Wyko 6000.

  • PDF

정밀 좌표측정용 머신비전 시스템의 광학적 해석에 관한 연구 (A Study on the optical aspects of machine vision based dimensional measurement system)

  • Lee, E.H.
    • 한국정밀공학회지
    • /
    • 제11권2호
    • /
    • pp.149-163
    • /
    • 1994
  • A novel method of dimensional measurement using machine vision, which is called Landmark Tracking System, has been developed. Its advantages come form tracking only the bright, standard shaped "landmarks" which are made from retroreflective sheets. In the design of the LTS, it is essential to know the relationship between optical parameters and their influence on system performance. Such optical parameters include the brightness of landmark image, the illumination system design, and the choice of imaging optics. And the performance of retroreflective material also plays important role in the LTS performances. Influences of such optical parameters on LTS's dimensional measurement characteristics are investigated, with respect to the retroreflective material, the imaging optics, and the illumination system. Measuremtn errors due to parameter variations are also analyzed. Experiments are performed with a LTS prototype. Retroreflective characteristics are verified, and the LTS's measurement performances are measured in the form of repeatability and accuracy. Experimental results shgow that the LTS has repeatability better than 1/30,000 of a field of view(30 degrees), and accuracy better tha 1/3,000 of a field fo view.d fo view.

  • PDF

레이저 반사광을 이용한 표면 거칠기 측정 시스템에서 스크린의 영향에 관한 연구 (Study on the influence of a screen in the surface roughness measure sstem based on parametric optical analysis)

  • 서영호;김화영;안중환;최이존
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2003년도 춘계학술대회
    • /
    • pp.845-850
    • /
    • 2003
  • The scattered light pattern from a machined surface generally contains much information concerning the surface roughness. The light pattern can be acquired by optical system and analyzed by statistical method. This kind of surface roughness measurement system can be easily adopted on the machine measurement. But the fully assembled system is too complex to implement on small systems using micro-controller. This study proposes the idea of reducing the number of optical components by removing screen and examines image processing of a light pattern to minimize the negative result of incomplete optical system. And the Gaussian blur filtering is concluded to be the best method of proposed measurement system. Furthermore light intensity variation of image pattern can be treated as a signal, therefore FIR filtering gives the similar result of Gaussian blur effect.

  • PDF

광학을 이용한 미술품의 표면측정시스템 제작 및 광학적 특성분석을 통한 진위감정 (Development of an Optical Measurement System for the Authenticity of Paintings)

  • 황선희;송혜린;김규정
    • 한국광학회지
    • /
    • 제28권3호
    • /
    • pp.103-107
    • /
    • 2017
  • 본 논문에서는 미술품의 광학적 특성을 분석하여 진위감정을 할 수 있는 시스템을 제작해보았다. 기존의 진위감정방법들보다 간단하고 정확한 광학적 진위감정시스템을 이용하여 미술품의 표면을 측정하고 정보를 얻고자 하였다. 첫 번째로 백색광을 이용하여 다양한 색이 칠해져 있는 미술품 표면의 고유한 색상정보를 확인하였다. 두 번째로는 라인레이저를 이용하여 미술품이 가진 표면형상에 대한 정보를 확인하였다. 진위감정시스템의 신뢰성을 평가하기 위해 진작과 비슷한 위작을 제작하여 실험을 진행해 본 결과, 진작과 위작이 서로 다른 데이터를 보여줌으로써 진작으로부터 위작을 쉽게 감별할 수 있었다.

Spectral-Domain 광 계측을 위한 CCD 이미지 센서 드라이버 제작 (Realization of CCD Image Sensor Driver for Spectral-Domain Optical Measurement System)

  • 김훈섭;이정렬;엄진섭
    • 산업기술연구
    • /
    • 제27권B호
    • /
    • pp.125-128
    • /
    • 2007
  • This paper presents Spectral-Domain optical measurement system using self-fabricated CCD sensor driver. The light source is a high brightness white LED and the detector is a 2048 array typed CCD image sensor. I have fabricated the CCD sensor driver to generate four pulse signals, which are the CCD-driving pulses. Using this Spectral Domain optical measurement system, the distance value between the reference mirror and the sample mirror can be obtained successfully.

  • PDF

지중선로의 분포 온도 측정 시스템 개발 (Development of optical temperature distribution measurement system for Underground Power Transmission tunnel)

  • 이근양;송우성
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1998년도 하계학술대회 논문집 B
    • /
    • pp.766-768
    • /
    • 1998
  • Optical Temperature Distribution measurement System (OTDS) is completely different from conventional electric point sensor in that it uses the optical fiber itself as the sensor. This new concept in temperature measuring system requires only one fiber to be laid. The use of optical fiber also gives the advantage of small diameter, light weight, explosion resistance, and electromagnetic noise resistance. The OTDS is a sensor which is capable of making a precise measurement over a wide range of areas using only a single optical fiber. Since current temperature sensors, such as the thermocouple, are only used to measure temperaturea of point, they are almost impractical for measuring a wider range because of the extremely high cost. In comparision with current sensors, the optical fiber distributed temperature sensor can make much quicker and more precise measurements at a comparatively low cost.

  • PDF

컴퓨터 제작 홀로그램과 데오도라이트를 이용한 인공위성 카메라 주 반사경의 정점 좌표 측정 (Measurement of Primary-mirror Vertex Coordinates for a Space Camera by Using a Computer-generated Hologram and a Theodolite)

  • 강혜은;송재봉;양호순;김학용
    • 한국광학회지
    • /
    • 제28권4호
    • /
    • pp.146-152
    • /
    • 2017
  • 우주용 인공위성 카메라를 구성하는 반사경의 정렬은 광학계의 고분해능, 고성능을 얻기 위한 중요한 과정 중 하나이다. 반사경들의 상호정렬에는 큐브미러(cube mirror)가 대신 사용되기 때문에, 각 반사경과 해당 큐브미러 간의 상호위치관계 정보가 우선 필요하다. 따라서 우주용 카메라 반사경들의 정렬을 위해 각 반사경의 정점과 해당 큐브미러의 상대 좌표값을 정확하게 측정해야하며, 본 논문에서는 컴퓨터 제작 홀로그램(computer-generated hologram, CGH)의 정렬용 세그먼트와 광섬유를 이용하는 새로운 측정 시스템을 제안함으로써 우주용 카메라를 구성하는 반사경의 정점을 요구조건 이내로 측정할 수 있었다. 측정 시스템은 광학계 평가용 간섭계, CGH, 광섬유, 반사경으로 구성되어 있으며, 최종적으로 데오도라이트를 이용해 큐브미러를 기준으로 주 반사경의 정점에 위치한 광섬유 끝단의 3차원 상대 좌표값을 $25{\mu}m$ 이하의 정밀도로 측정할 수 있었다.