• Title/Summary/Keyword: optical image

Search Result 2,683, Processing Time 0.032 seconds

The Moving Object Detecting and Tracking System Using the Difference Images (차영상을 이용한 이동 방향 검출 및 추적 시스템)

  • Moon, Cheol-Hong;Kim, Sung-Oh;Kim, Kap-Sung;Jang, Dong-Young;Roo, Young-Soo
    • Proceedings of the IEEK Conference
    • /
    • 2006.06a
    • /
    • pp.421-422
    • /
    • 2006
  • Using the still image through the camera reports which the moving object tracking system. Moving object direction detected to compare the two difference images. And base block set at moving object. Matching area set current difference image. The edge image of prior frame and current frame implement the moving object tracking system to block matching.

  • PDF

A Study on Construction of Technical Reports Management System Using Optical Technology (광기술을 이용한 연구보고서 관리시스템 구축)

  • 이상헌;김익철
    • Journal of the Korean Society for information Management
    • /
    • v.9 no.1
    • /
    • pp.131-164
    • /
    • 1992
  • In this study. a technical report management system using optical technology is described in detail. This management system is designed for both bibliographic (character) and full-text (image) information. Several optical filing systems already on the Korean market are scrutinized and compared with standard functions in order to build a more efficient management system for technical reports which can be easily integrated into existing KRISS library automation system. For that purpose, up-to-date technologies (i.e., digital image PI-ocessing (DIP), MARC standards, and optical character recognition (OCR), etc.) are applied to this system.

  • PDF

AEROSOL OPTICAL THICKNESS ESTIMATED FROM LANDSAT/ETM+IMAGE DATA

  • Kawata, Yoshiyuki;Fukul, Haruki;Takemata, Kazuya
    • Proceedings of the KSRS Conference
    • /
    • 2002.10a
    • /
    • pp.378-381
    • /
    • 2002
  • We retrieved the aerosol optical thickness $\tau$$_{a}$ over land from Landsat-7/ETM+ image data using the correlation between the visible reflectance and middle IR reflectance. This band correlation method for aerosol retrieval was originally proposed fur MODIS data analysis by Kaufman et al.(1977). The results of retrieved aerosol optical thickness $\tau$$_{a}$ from Landsat-7/ETM+ data were compared with the simultaneous sky observation data at our study site. We found a good agreement between the retrieved and observed values. We presented the distribution maps of the aerosol optical thickness over land, retrieved from Landsat-7/ETM+ image data. Then, the surface reflectance map was also presented. The aerosol optical thickness over sea was retrieved assuming no reflected contribution from sea in the near IR band. In addition, we discussed some limitations when we apply the band correlation method.

  • PDF

Optical Design of an Off-axis Five-mirror-anastigmatic Telescope for Near Infrared Remote Sensing

  • Li, Xing Long;Xu, Min;Pei, Yun Tian
    • Journal of the Optical Society of Korea
    • /
    • v.16 no.4
    • /
    • pp.343-348
    • /
    • 2012
  • This paper described an off-axis five-mirror-anastigmatic telescope. It is composed of three aspheric surfaces and one spherical surface while the third mirror and fifth mirror have the same parameters at the same place. This configuration is useful for having wide field of view. The strip full field of view for the near infrared telescope is $20^{\circ}{\times}0.2^{\circ}$. The entrance pupil is located in front of the first mirror. There is an intermediate image between the second mirror and the third mirror. The entrance pupil diameter is 100 mm and the effective focal length is 250 mm. The spectral range is $0.85-1.75{\mu}m$. The pixel pitch is $15{\mu}m$. The image quality is near the diffraction limit. Some methods were used to restrain the stray light such as a field stop near the intermediate image, the baffle, the narrow-band pass filter and a stop in front of the focal plane.

Accuracy of the Point-Based Image Registration Method in Integrating Radiographic and Optical Scan Images: A Pilot Study

  • Mai, Hai Yen;Lee, Du-Hyeong
    • Journal of Korean Dental Science
    • /
    • v.13 no.1
    • /
    • pp.28-34
    • /
    • 2020
  • Purpose: The purpose of this study was to investigate the influence of different implant computer software on the accuracy of image registration between radiographic and optical scan data. Materials and Methods: Cone-beam computed tomography and optical scan data of a partially edentulous jaw were collected and transferred to three different computer softwares: Blue Sky Plan (Blue Sky Bio), Implant Studio (3M Shape), and Geomagic DesignX (3D systems). In each software, the two image sets were aligned using a point-based automatic image registration algorithm. Image matching error was evaluated by measuring the linear discrepancies between the two images at the anterior and posterior area in the direction of the x-, y-, and z-axes. Kruskal-Wallis test and a post hoc Mann-Whitney U-test with Bonferroni correction were used for statistical analyses. The significance level was set at 0.05. Result: Overall discrepancy values ranged from 0.08 to 0.30 ㎛. The image registration accuracy among the software was significantly different in the x- and z-axes (P=0.009 and <0.001, respectively), but not different in the y-axis (P=0.064). Conclusion: The image registration accuracy performed by a point-based automatic image matching could be different depending on the computer software used.

Effect of image matching experience on the accuracy and working time for 3D image registration between radiographic and optical scan images (술자의 영상정합의 경험이 컴퓨터 단층촬영과 광학스캔 영상 간의 정합 정확성과 작업시간에 미치는 영향)

  • Mai, Hang-Nga;Lee, Du-Hyeong
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.59 no.3
    • /
    • pp.299-304
    • /
    • 2021
  • Purpose. The purpose of the present study was to investigate the effects of image matching experience of operators on the accuracy and working time of image registration between radiographic and optical scan images. Materials and methods. Computed tomography and optical scan of a dentate dental arch were obtained. Image matching between the computed tomography and the optical scan (IDC S1, Amann Girrbach, Koblah, Austria) was performed using the point-based automatic registration method in planning software programs (Implant Studio, 3Shape, Copenhagen, Denmark) using two different experience conditions on image registration: experienced group and inexperienced group (n = 15 per group, N = 30). The accuracy of image registration in each group was evaluated by measuring linear discrepancies between matched images, and working time was recorded. Independent t test was used to statistically analyze the result data (α = .05). Results. In the linear deviation, no statistically significant difference was found between the experienced and inexperienced groups. Meanwhile, the working time for image registration was significantly shorter in the experienced group than in the inexperienced group (P = .007). Conclusion. Difference in the image matching experience may not influence the accuracy of image registration of optical scan to computed tomography when the point-based automatic registration was used, but affect the working time for the image registration.

Speckle Reduction in the Wavelet Domain for Image with Optical Coherence Tomography

  • Chang, Ju-Wan;Lee, Chang-Su;Na, Ji-Hoon;Paes, Stephane;Lee, Byeong-Ha
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2005.06a
    • /
    • pp.2459-2463
    • /
    • 2005
  • Optical coherence tomography (OCT) is high resolution medical imaging system which is obtaining image inside biological objects with non-destructive method. OCT system is based on Michelson interferometer with a reciprocating mirror in the reference arm and a biological object in the sample arm. The obtained OCT image suffers from a granular or mottled image, called speckle. Speckle is caused by random interferences between reflected coherence waves. In this paper, we propose effective speckle reduction method that uses wavelet transform. With wavelet domain image, sub-windowing and thresholding are performed. Finally, speckle reduction experiments for Misgurnus mizolepis skin and rat eye images are shown.

  • PDF

Interferometric Image Encryption and Decryption using Binary Phase Hologram (이진 위상 홀로그램을 이용한 간섭성 영상 암호화 및 복원)

  • 김종윤;김정우
    • The Journal of the Korea Contents Association
    • /
    • v.2 no.3
    • /
    • pp.80-86
    • /
    • 2002
  • In this paper, we propose the new optical security technique using two phase holograms based on interferometer. The encoded random phase image does not have any information on the original image. Without Hewing the key mask, one cannot decode the encrypted image and regenerate the original image. And the use of two phase only images in the proposed security system leads to maximum optical efficiency (100% in theory). Also they cannot be detected by an intensity detector such as a CCD camera. Computer simulations and optical experiments show performance of the proposed methods.

  • PDF

A Study on the Real-time Optical Associative Memory Using Photorefractive Effects in $BaTiO_{3}$ ($BaTiO_{3}$ 의 광굴절 현상을 이용한 실시간 광연상 메모리에 관한 연구)

  • Ihm, J.T.;Oh, C.S.;Kim, S.I.;Park, H.K.
    • Proceedings of the KIEE Conference
    • /
    • 1988.07a
    • /
    • pp.410-413
    • /
    • 1988
  • In this paper, the real-time optical associative memory using multiple hologram which is generated with two angular multiplexed reference beams and Fourier transformed object beam in the $BaTiO_{3}$ crystal based on DFWM mechanism. When one image is recorded in the $BaTiO_{3}$ crystal, complete image can be recalled by 9 % partial input of the stored original image without any additional thresholding and optical feedback process. As an experimental result of multiple Fourier hologram which is recorded with two binary images, OHCHAS and PARKHK, we can obtain complete image recalled by 1/6 partial input of the stored image.

  • PDF

Field-Curvature Correction According to the Curvature of a CMOS Image-Sensor Using Air-Gap Optimization

  • Kwon, Jong-Hoon;Rhee, Hyug-Gyo;Ghim, Young-Sik;Lee, Yun-Woo
    • Journal of the Optical Society of Korea
    • /
    • v.19 no.6
    • /
    • pp.658-664
    • /
    • 2015
  • Lens designers generally refer to flat image fields and attempt to minimize the field curvature. Present-day CMOS image sensors for mobile phone cameras, however, are not flat, but curved. Sometimes it is necessary to generate an intentional field curvature according to the degree and direction of the CMOS image-sensor’s curvature. This paper presents the degree of curvature of a CMOS image sensor measured using an interferometer, and proposes an effective compensation method that minimizes the net field curvature through optimizing the air gap between lens elements, which is demonstrated using simulations and experiments.