• Title/Summary/Keyword: optical eyes

Search Result 153, Processing Time 0.024 seconds

Head Mouse System Based on A Gyro and Opto Sensors (각속도 및 광센서를 이용한 헤드 마우스)

  • Park, Min-Je;Yoo, Jae-Ha;Kim, Soo-Chan
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.46 no.4
    • /
    • pp.70-76
    • /
    • 2009
  • We proposed the device to control a computer mouse with only head movements and eye blinks so that disabilities by car or other accidents can use a computer. The mouse position were estimated from a gyro-sensor which can measure head movements, and the mouse events such as click/double click were from opto sensors which can detect the eyes flicker, respectively. The sensor was mounted on the goggle in order not to disturb the visual field. There was no difference in movement speed between ours and a general mouse, but it required 3$\sim$4 more times in the result of the experiment to evaluate spatial movements and events detection of the proposed mouse because of the low accuracy. We could eliminate cumbersome work to periodically remove the accumulated error and intuitively control the mouse using non-linear relative point method with dead zones. Optical sensors are used in the event detection circuitry designed to remove the influence of the ambient light changes, therefore it was not affected in the change of external light source.

Simulation of Distortion in Image Space due to Observer's Rotation Movement in Stereoscopic Display, and Its Correction (스테레오스코픽 디스플레이에서 관찰자의 회전이동에 따른 영상공간의 왜곡과 왜곡 보정에 대한 전산모사)

  • Kim, Dong-Wook;Lee, Kwang-Hoon;Kim, Sung-Kyu;Chang, Eun-Young
    • Korean Journal of Optics and Photonics
    • /
    • v.20 no.2
    • /
    • pp.87-93
    • /
    • 2009
  • Variation of the observer's viewing position is one of the major causes of image space distortion in the stereoscopic display. Especially, a large image distortion, which is caused by different depth direction positions of the observer's two eyes, is made by the observer's rotation movement in relation to the center of the screen. This is different from distortion of horizontal and depth directional movement of the observer. In this paper, we analyzed distortion of the image space due to the observer's rotation movement and showed the corrected result of distortion through simulation in the stereoscopic display. Finally, we showed that the distortion shape of the observer's rotation movement is different from horizontal and depth directional movement of the observer.

The Efficacy of Ampule Containing Herbal Extract for Improving Skin Wrinkles in Women (한약재 추출물 함유 앰플의 주름개선 효능에 관한 기초 임상연구)

  • Do, Eun-Ju;Lee, Jin-Sang;Park, Hyun-Jin;Ha, Il-Do;Kim, Young-Chul;Kim, Mi-Ryeo
    • Herbal Formula Science
    • /
    • v.17 no.2
    • /
    • pp.111-121
    • /
    • 2009
  • Objectives : This study was performed to evaluate the efficacy of ampule containing herbal extract(Ulmus davidiana, Ginkgo biloba, Perilla ocymoides, Morus alba, Glycyrrhiza uralensis (licorice), and Angelica gigas) on skin wrinkles in adult women with facial wrinkles. Methods : A total of 12 women, 30 to 46 years of age, with wrinkles in the corner of eyes, applied ampule containing herbal extract twice daily for up to 12 weeks. Silicon replicas of right crow's feet area and antecubital fossa were taken before use of test product and at 4, 8 and 12 weeks. The replicas were analyzed by optical profilometry with Skin Visiometer SV600. The wrinkle and roughness parameters, R1, R2, R3, R4 and R5 were calculated and statistically analyzed. In addition, a subjective evaluation of product efficacy was conducted by patient's assessment. Results : The mean values of all the skin roughness parameters were decreased at 4-week, and decreased significantly at 8 and 12-week except R4 at 12-week after test product use. The subjective evaluation of wrinkle by patient's assessment was also improved. However, one patient noted stiffness of face after use of test product. Conclusions : These study suggested that the application of ampule containing herbal extract twice daily for 12 weeks may effectively improve the facial wrinkles without severe side effect.

  • PDF

Detection of Candidate Areas for Automatic Identification of Scirtothrips Dorsalis (볼록총채벌레 자동판정을 위한 후보영역 검출)

  • Moon, Chang Bae;Kim, Byeong Man;Yi, Jong Yeol;Hyun, Jae Wook;Yi, Pyoung Ho
    • Journal of Korea Society of Industrial Information Systems
    • /
    • v.17 no.6
    • /
    • pp.51-58
    • /
    • 2012
  • Scirtothrips Dorsalis (Thysanoptera: Thripidae) recently has been recognized as a major source of the pest damage in the citrus fruit orchards. So its arrival has been predicted periodically but it is difficult to identify adults of the pest with the naked eyes because of their size smaller than the 0.8mm. In this paper, we propose a method to detect candidate areas for automatic identification of Scirtothrips Dorsalis on forecasting traps. The proposed method uses a histogram-based template matching where the composite image synthesized with the gray-scale image and the gradient image is used. In our experiments, images are acquired by the optical microscopy with 50 magnifications. To show the usefulness of the proposed method, it is compared with the method we previously suggested. Also, the performances when the proposed method is applied to noise-reduced images and gradient images are examined. The experimental results show that the proposed method is approximately 14.42% better than our previous method, 41.63% higher than the case that the noise-reduced image is used, and 21.17% higher than the case that the gradient image is used.

Solution to Slow Down Myopia Progression

  • Jung, Ji-Won
    • Journal of Korean Clinical Health Science
    • /
    • v.8 no.1
    • /
    • pp.1386-1397
    • /
    • 2020
  • Purpose: To examine the effectiveness of various treatments; bifocal spectacles, orthokeratology, atropine, and time spent in outdoors; in slowing down the myopia progression for Asian adolescents (6-18age). Methods: The research focused on examining the most effective treatment in controlling myopia based on the literature sources that have been published. Through meta-analysis of various research papers that already has been done in this field, a lot of data was collected. For each treatment, the difference in axial length and spherical equivalent over time was measured and recorded. To quantitatively record the difference, both axial length and spherical equivalent was determined by value of control group value of treatment group. The paper compared the effectiveness of each treatment based on the data that was measured. Results: Adolescents who chose to spend time outdoors in order to slow down myopia progression had axial length difference of 0.03 mm and spherical equivalent difference of 0.17 D. Adolescents that used atropine had axial length difference of 0.36 mm and spherical equivalent difference of 0.92 D. Bifocal spectacle resulted in axial length difference of 0.21 mm and spherical equivalent difference of 0.59 D, and for orthokeratology 0.23 mm and 0.04 D, respectively. Axial length wise, myopia was most controlled by the atropine since there was a greatest difference between the group that got the treatment and the group that did not have the treatment. According to the spherical equivalent difference data, myopia was most controlled by atropine. Conclusion: Atropine showed the most effective result in controlling myopia among the four treatment. Again, compared to other three treatment, using atropine appeared to have greatest ability in slowing down myopia progression since adolescents who were treated with atropine had greatest difference from adolescents in the control group that had the same condition but didn't get the treatment. However, every treatment was only used for 2 or 3 years which is quite short time period to measure the long term effect of the four treatments. Also, since atropine is a pharmaceutical method to control myopia, it may harm adolescents' eyes compared to optical or environmental treatment.

The diagnosis of Plasma Through RGB Data Using Rough Set Theory

  • Lim, Woo-Yup;Park, Soo-Kyong;Hong, Sang-Jeen
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2010.02a
    • /
    • pp.413-413
    • /
    • 2010
  • In semiconductor manufacturing field, all equipments have various sensors to diagnosis the situations of processes. For increasing the accuracy of diagnosis, hundreds of sensors are emplyed. As sensors provide millions of data, the process diagnosis from them are unrealistic. Besides, in some cases, the results from some data which have same conditions are different. We want to find some information, such as data and knowledge, from the data. Nowadays, fault detection and classification (FDC) has been concerned to increasing the yield. Certain faults and no-faults can be classified by various FDC tools. The uncertainty in semiconductor manufacturing, no-faulty in faulty and faulty in no-faulty, has been caused the productivity to decreased. From the uncertainty, the rough set theory is a viable approach for extraction of meaningful knowledge and making predictions. Reduction of data sets, finding hidden data patterns, and generation of decision rules contrasts other approaches such as regression analysis and neural networks. In this research, a RGB sensor was used for diagnosis plasma instead of optical emission spectroscopy (OES). RGB data has just three variables (red, green and blue), while OES data has thousands of variables. RGB data, however, is difficult to analyze by human's eyes. Same outputs in a variable show different outcomes. In other words, RGB data includes the uncertainty. In this research, by rough set theory, decision rules were generated. In decision rules, we could find the hidden data patterns from the uncertainty. RGB sensor can diagnosis the change of plasma condition as over 90% accuracy by the rough set theory. Although we only present a preliminary research result, in this paper, we will continuously develop uncertainty problem solving data mining algorithm for the application of semiconductor process diagnosis.

  • PDF

Forming Properties of Micro Random Pattern Using Micro Abrasive Paper Tool by Roll to Plate Indentation Method (미세 지립 페이퍼 공구와 롤투플레이트 압입공정을 이용한 마이크로 랜덤 패턴의 성형특성)

  • Jeong, Ji-Young;Je, Tae-Jin;Moon, SeungHwan;Lee, Je-Ryung;Choi, Dae-Hee;Kim, Min-Ju;Jeon, Eun-chae
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.33 no.5
    • /
    • pp.385-392
    • /
    • 2016
  • Recently in the display industry, demands for high-luminance and resolution of display devices have been steadily increasing. Generally, micro linear patterns are applied to an optical film in order to improve its properties of light. However, these patterns are easily viewed to eyes and moire phenomenon can be occurred. Micro random patterns are proposed as a method to solve these problems, increasing light-luminance and light-diffusion. However, conventional pattern manufacturing technologies have long processing times and high costs making it difficult to apply to large area molds. In order to combat this issue, micro-random patterns are formed by using a roll to plate indentation method along with abrasive paper tools composed of AlSiO2, SiC, and diamond grains. Also, forming properties, such as size and fill-factor of random patterns, are analyzed depending on type, mesh of abrasive paper tools, and indentation forces.

Synthesis, Film Fabrication, and Optical Properties of Polymers Containing Metal Cation Complex Type D-$\pi$-A Chromophore (금속 양이온 배위형 D-$\pi$-A 발색단을 포함하는 폴리머의 합성 및 박막화와 광학특성)

  • Jeong, Seon-Ju;Kim, Hye-Ryun;Yoon, Keun-Byoung;Han, Yoon-Soo;Fujiki, Michiya;Takagi, Akiko;Kwak, Gi-Seop
    • Polymer(Korea)
    • /
    • v.34 no.4
    • /
    • pp.376-380
    • /
    • 2010
  • Donor-$\pi$-acceptor (D-$\pi$-A) type chromophore-based polymers were newly synthesized. These polymers exhibited absorption peak due to intramolecular charge transfer (ICT) in a visible range as well as absorption peak due to carbonyl group in both solution and film state by measuring UV visible spectra. The addition of $Eu^{3+}$ ion into the polymers induced red-shift in absorption due to ICT and the color changes from yellow to red in the solution and film were observed by naked eyes. The contents of crosslinking agent influenced the features and solubility of the polymers. In addition, the contents of crosslinking agent and the $Eu^{3+}$ ion addition improved film-forming ability.

The improved facial expression recognition algorithm for detecting abnormal symptoms in infants and young children (영유아 이상징후 감지를 위한 표정 인식 알고리즘 개선)

  • Kim, Yun-Su;Lee, Su-In;Seok, Jong-Won
    • Journal of IKEEE
    • /
    • v.25 no.3
    • /
    • pp.430-436
    • /
    • 2021
  • The non-contact body temperature measurement system is one of the key factors, which is manage febrile diseases in mass facilities using optical and thermal imaging cameras. Conventional systems can only be used for simple body temperature measurement in the face area, because it is used only a deep learning-based face detection algorithm. So, there is a limit to detecting abnormal symptoms of the infants and young children, who have difficulty expressing their opinions. This paper proposes an improved facial expression recognition algorithm for detecting abnormal symptoms in infants and young children. The proposed method uses an object detection model to detect infants and young children in an image, then It acquires the coordinates of the eyes, nose, and mouth, which are key elements of facial expression recognition. Finally, facial expression recognition is performed by applying a selective sharpening filter based on the obtained coordinates. According to the experimental results, the proposed algorithm improved by 2.52%, 1.12%, and 2.29%, respectively, for the three expressions of neutral, happy, and sad in the UTK dataset.

Evaluation of Tear Film Lipid Layer Thickness Measurements Obtained Using an Ocular Surface Interferometer in Nasolacrimal Duct Obstruction Patients

  • Lee, Sang Min;Chung, Sok Joong;Lew, Helen
    • Korean Journal of Ophthalmology
    • /
    • v.32 no.6
    • /
    • pp.445-450
    • /
    • 2018
  • Purpose: To compare the tear film lipid layer thickness (LLT) between patients with incomplete nasolacrimal duct obstruction (NLDO) and normal controls and to analyze the changes in tear film LLT and blinking pattern after silicone tube intubation in NLDO patients. Methods: We reviewed the medical records of 68 eyes in 52 incomplete NLDO patients who underwent silicone tube intubation from January 2017 to July 2017. The LLT, blinking pattern, and Meibomian gland image were measured with the LipiView II ocular surface interferometer. The Meibomian gland drop-out ratio was measured using the polygon selection tool in the Image J program. Tear meniscus height, which is the other lacrimal indicator, was assessed with spectral-domain optical coherence tomography. Results: Tear meniscus height was significantly decreased after silicone tube intubation (p < 0.01). Preoperative minimum, maximum, and average LLT values were $62.4{\pm}24.0$, $86.7{\pm}17.9$, and $71.7{\pm}23.3nm$, respectively. Significant changes in the minimum, maximum, and average LLT ($74.8{\pm}23.6$, $98.8{\pm}11.0$, and $91.6{\pm}16.1nm$, respectively) were observed after silicone tube intubation (p < 0.001, p = 0.001, and p < 0.001). The partial blinking/total blinking ratio in 20 seconds and the Meibomian gland drop-out ratio showed no significant change after silicone tube intubation. Conclusions: Overall, the LLT was increased after silicone tube intubation. Silicone tube intubation may be helpful in maintaining LLT with a normalized of amount of tears.