• 제목/요약/키워드: optical depth

검색결과 878건 처리시간 0.03초

A Method for Precise Depth Detection in Stereoscopic Display

  • Lee Seung-Woo;Kim Nam
    • Journal of the Optical Society of Korea
    • /
    • 제10권1호
    • /
    • pp.37-41
    • /
    • 2006
  • This paper discusses a method for precise depth detection in stereoscopic images. The geometry of a stereoscopic camera and a display system is presented. It was found that there exists a difference between the calculated depth and the perceived depth of objects. For precise depth detection, the proposed registration method is investigated and proved by experiment in stable condition.

학습기반의 객체분할과 Optical Flow를 활용한 2D 동영상의 3D 변환 (2D to 3D Conversion Using The Machine Learning-Based Segmentation And Optical Flow)

  • 이상학
    • 한국인터넷방송통신학회논문지
    • /
    • 제11권3호
    • /
    • pp.129-135
    • /
    • 2011
  • 본 논문에서는 2D 동영상을 3D 입체영상으로 변환하기 위해서 머신러닝에 의한 학습기반의 객체분할과 객체의 optical flow를 활용하는 방법을 제안한다. 성공적인 3D 변환을 가능하게 하는 객체분할을 위해서, 객체의 칼라 및 텍스쳐 정보는 학습을 통해 반영하고 움직임이 있는 영역 위주로 객체분할을 수행할 수 있도록 optical flow를 도입한 새로운 에너지함수를 설계하도록 한다. 분할된 객체들에 대해 optical flow 크기에 따른 깊이맵을 추출하여 입체영상에 필요한 좌우 영상을 합성하여 생성하도록 한다. 제안한 기법으로 인해 효과적인 객체분할과 깊이맵을 생성하여 2D 동영상에서 3D 입체동영상으로 변환됨을 실험결과들이 보여준다.

표면 추적 알고리즘을 적용한 공통경로 FD-OCT의 성능개선 (Enhancement of Common-path Fourier-domain Optical Coherence Tomography using Active Surface Tracking Algorithm)

  • 김민호;김거식;송철규
    • 전기학회논문지
    • /
    • 제61권4호
    • /
    • pp.639-642
    • /
    • 2012
  • Optical coherence tomography(OCT) can provide real-time and non-invasive subsurface imaging with ultra-high resolution of micrometer scale. However, conventional OCT systems generally have a limited imaging depth range within a depth of only 1-2 mm. To overcome the limitation, we have proposed an active surface tracking algorithm used in common-path Fourier-domain OCT system in order to extend the imaging depth range. The surface tracking algorithm based on the threshold and Savitzky-Golay filter of A-scan data was applied to real-time tracking. The algorithm has controlled a moving stage according to the sample's surface variance in real time. An OCT image obtained by the algorithm clearly show an extended imaging depth range. Consequently, the proposed algorithm demonstrated the potential for improving the conventional OCT systems with limitary depth range.

심중 프렌넬 렌즈 시스템에서 재생된 입체부양영상의 올바른 깊이감을 구현하기 위한 시차보정 방법에 대한 연구 (A Study on Compensation of Disparity for Incorrect 3D Depth in the Triple Fresnel Lenses floating Image System)

  • 이광훈;김수호;윤영수;김성규
    • 한국광학회지
    • /
    • 제18권4호
    • /
    • pp.246-255
    • /
    • 2007
  • 부양영상시스템은 광학계를 통하여 입력영상 또는 물체의 상을 표시소자의 최종면으로부터 떨어진 특정 공간 내에 재생하는 장치이다. 재생된 입력영상은 표시소자와 관찰자 사이의 공간상에 위치하며 관찰자에게 가상의 입체효과를 제공한다. 입체부양영상시스템은 입체영상 및 입체상을 입력영상으로 하여 재생된 부양영상 내에 돌출 및 후퇴방향의 입체효과를 부과하여 기존의 입체영상 표시소자보다 효과적인 깊이감을 제공한다. 일반적으로 입체영상으로 쓰이는 입력영상의 크기 및 시차량은 광학계를 통하지 않는 입체영상 표시소자에 최적화되어 있다. 따라서 광학계를 통하여 입체상을 재생할 경우, 관찰자에게 재생된 입력영상의 크기 및 시차량은 광학계의 최종배율에 따라 축소 또는 확대된다. 그러나 관찰자와 디스플레이의 최종 면 사이의 관찰거리는 불변이므로 광학계를 통하여 재생된 입체부양영상은 관찰자에게 최종배율과 다른 깊이감을 제공한다. 본 논문은 삼중 프렌넬 렌즈로 이루어진 광학계에서 입체부양영상용 입력영상의 시차량을 광학계의 최종배율에 비례하도록 보정하고, 관찰자에게 올바른 깊이감을 제공하는 방법 및 결과를 제시하였다. 이 광학계는 부양영상의 부양 심도 및 영상의 질 향상을 위하여 사용되었고, 입력영상으로는 19인치 무안경식 입체영상 표시소자를 통하여 재생된 입체영상이 사용되었다.

Lidar Measurement of Optical Properties of Cirrus Clouds at Kwangju, Korea

  • Noh, Y.M.;Choi, S.C.;Kim, Y.J.
    • 대한원격탐사학회:학술대회논문집
    • /
    • 대한원격탐사학회 2003년도 Proceedings of ACRS 2003 ISRS
    • /
    • pp.959-961
    • /
    • 2003
  • Cirrus clouds observation was conducted using a lidar system in order to measure their height, thickness and optical depth at Kwangju (35$^{\circ}$10'N, 126$^{\circ}$53'), Korea in winter, December 2002, and spring March and April 2003. Cirrus clouds at high altitude can be distinguished from atmospheric aerosols location by high depolarization ratio and high altitude. Cirrus clouds were observed at 5${\sim}$12km altitudes with a high depolarization ratio from 0.2 to 0.5. Optical depth of cirrus clouds had varied from 0.28 to 1.81. Radiative effect of observed cirrus cloud on climate system was estimated to be negative net flux from ?0.24 to ?31.04 W/m$^{2}$.

  • PDF

초기우식병소에 대한 레이저 fluorescence의 광학적 탐지감도 (OPTICAL SENSITIVITY OF LASER FLUORESCENCE FOR INCIPIENT CARIES DETECTION)

  • 김효석;김왕근;이창섭;이상호
    • 대한소아치과학회지
    • /
    • 제26권1호
    • /
    • pp.109-118
    • /
    • 1999
  • The aim of this study was to evaluate the optical density of laser fluorescence for detection of incipient caries. Prepared and polished bovine enamel specimens were demineralized in a STPP solution for varying periods of time between 3 hrs. and 60 hrs. with an area of sound enamel retained on each specimen. The randomized specimens were analyzed for optical density of enamel demineralization using laser fluorescence. The specimens were sectioned and examined lesion depth by polarizing light microscope. Results were analyzed statistically with SAS program. The results from this study can be summarized as follows: 1. Optical density measured by laser fluorescence and lesion depth measured by polarizing light microscope was increased as demineralization time was increased(p<0.001). 2. Between optical density measured by laser fluorescence and lesion depth measured by polarizing light microscope was correlated highly(${\gamma}{\geq}0.74956$, p<0.001). 3. Regressive equation was obtained in this study as follows. Y=[X-0.260851]/0.000271(R-square:0.5618, p<0.001) (X:DENSITY, Y:DEPTH) In summary, optical density measured by laser fluorescence would be within the range of possibility to quantitatively presume demineralization amount of incipient caries lesion

  • PDF

Depth Resolution Analysis of Axially Distributed Stereo Camera Systems under Fixed Constrained Resources

  • Cho, Myungjin;Shin, Donghak
    • Journal of the Optical Society of Korea
    • /
    • 제17권6호
    • /
    • pp.500-505
    • /
    • 2013
  • In this paper, we propose a novel framework to evaluate the depth resolution of axially distributed stereo sensing (ADSS) under fixed resource constraints. The proposed framework can evaluate the performance of ADSS systems based on various sensing parameters such as the number of cameras, the number of total pixels, pixel size and so on. The Monte Carlo simulations for the proposed framework are performed and the evaluation results are presented.

워터커튼에서 액적의 크기 분포와 광학 두께의 상관관계 분석 (Analysis on the Relations of Droplet Size Distribution and Optical Depth in Water Curtain)

  • 유우준;유홍선
    • 한국화재소방학회논문지
    • /
    • 제30권2호
    • /
    • pp.62-67
    • /
    • 2016
  • 본 연구에서는 워터 커튼용 노즐(Water curtian nozzle)의 액적 크기 분포(droplet size distribution)에 따라서 복사열을 감쇄하기 위한 광학 두께(optical depth)를 분석하였다. 액적 크기 분포를 측정하기 위해서 HELOS/VARIO 물 입자 측정 장치를 사용하였으며, Deirmenjian의 수정된 감마 분포 함수(modified gamma distribution function)를 적용하여 분사 특성을 정량화 하였다. 본 연구에서 사용한 워터 커튼용 노즐은 분포 상수(distribution constant) ${\alpha}=1$, ${\gamma}=5.2$의 값으로 나타났으며, 액적의 밀도 수(number density)를 고려한 분포 하중(droplet loading)과 액적 크기 분포 변화에 따라서 광학 두께에 관한 일반화된 관계식을 제시하였다. 본 연구 결과는 워터 커튼용 노즐의 설계 조건을 분석하기 위한 유용한 연구 자료가 될 것으로 사료된다.