• Title/Summary/Keyword: optical density

Search Result 1,824, Processing Time 0.022 seconds

Aero-optical transmitting effect in the compressible mixing layer

  • Ma, Handong;Gan, Caijun;Li, Lang
    • International Journal of Aerospace System Engineering
    • /
    • v.2 no.2
    • /
    • pp.79-82
    • /
    • 2015
  • The handicap for investigating the aero-optical effect focuses on the accurate prediction on the index refraction fluctuation or density fluctuation. In recent years, with the development of CFD techniques and optical experimental techniques, the comprehension have developed on the aero-optical transmitting effect in many kinds of complex flow. This study mainly introduces the optical aberration in compressible mixing layer. And then the debates about the mechanism of aero-optical effects and assessment of image blur also present.

Study of The Anisotropy of Electron Energy Distribution of Optical-Field Ionized Oxygen Plasma by Using Polarization Spectroscopy

  • Kim, Dong-Eon;Kim, Jae-Hoon;Kawachi, Tetsuya;Hasegawa, Noboru;Sukegawa, Kouta;Iwamae, Atsushi;Fujimoto, Takashi
    • Journal of the Optical Society of Korea
    • /
    • v.7 no.3
    • /
    • pp.145-149
    • /
    • 2003
  • The anisotropy of electron energy distribution in oxygen plasmas produced by a high intensity laser was investigated by using polarization spectroscopy. An ultra-short pulsed laser with a pulse duration of 66.5 fs and a power density of $1 {\times} 10^17/ W/$\textrm{cm}^2$$ was used. At this power density and pulse duration, the plasma was generated predominantly by optical field ionization. The degree of polarization of OVI 1s$^2$2p$^2$p2- 1s$^2$4d$^2$D$^{0}$ (J = 1/2-3/2 and 3/2-5/2) transition line at 129.92 $\AA$ was measured. O VI 1s$^2$2p$^2$P$^2$ -1s$^2$4s$^2$S$^2$ (J = 1/2-1/2 and 3/2-1/2) transition line at 132.26 $\AA$ was used to calibrate the sensitivity of the optical system. The dependencies of the degree of polarization on the initial gas density and on the laser polarization were investigated. When the laser polarization was changed from a linear to a circular polarization, the degree of polarization was decreased. When the initial gas density was increased, the degree of polarization was decreased.

Parallel Data Extraction Architecture for High-speed Playback of High-density Optical Disc (고용량 광 디스크의 고속 재생을 위한 병렬 데이터 추출구조)

  • Choi, Goang-Seog
    • Journal of Korea Multimedia Society
    • /
    • v.12 no.3
    • /
    • pp.329-334
    • /
    • 2009
  • When an optical disc is being played. the pick-up converts light to analog signal at first. The analog signal is equalized for removing the inter-symbol interference and then the equalized analog signal is converted into the digital signal for extracting the synchronized data and clock signals. There are a lot of algorithms that minimize the BER in extracting the synchronized data and clock when high. density optical disc like BD is being played in low speed. But if the high-density optical disc is played in high speed, it is difficult to adopt the same extraction algorithm to data PLL and PRML architecture used in low speed application. It is because the signal with more than 800MHz should be processed in those architectures. Generally, in the 0.13-${\mu}m$ CMOS technology, it is necessary to have the high speed analog cores and lots of efforts to layout. In this paper, the parallel data PLL and PRML architecture, which enable to process in BD 8x speed of the maximum speed of the high-density optical disc as the extracting data and clock circuit, is proposed. Test results show that the proposed architecture is well operated without processing error at BD 8x speed.

  • PDF

Extended Drude model analysis of n-doped cuprate, Pr0.85LaCe0.15CuO4

  • Lee, Seokbae;Song, Dongjoon;Jung, Eilho;Roh, Seulki;Kim, Changyoung;Hwang, Jungseek
    • Progress in Superconductivity and Cryogenics
    • /
    • v.17 no.4
    • /
    • pp.16-20
    • /
    • 2015
  • We investigated optical properties of an electron-doped copper oxide high temperature superconductor, $Pr_{0.85}LaCe_{0.15}CuO_4$ (PLCCO) single crystal. We obtained the optical conductivity from measured reflectance at various temperatures. We found our data contained c-axis longitudinal optical (LO) phonon modes due to miscut and intrinsic lattice distortion. We applied an extended Drude model to study the correlations between charge carriers in the system. The LO phonons appear as strong sharp peaks in the optical scattering rate. We tried to remove the LO phonon modes by using the energy loss function, which also shows the LO phonons as peaks, and could not remove them completely. We extracted the electron-boson spectral density function using a generalized Allen's formula. We observed that the resulting electron-boson density show similar temperature dependence as hole-doped cuprates.

The Analysis of position Sensitivity and Aberration characteristics of Liquid Crystal Elements (액정 소자의 위치 민감도 및 수차 특성에 대한 연구)

  • Heor Jae-Youn;Yoo Ho-Sik;Yoo Jang-Hoon;Park Soo Han;Jeong Soo-Jin
    • Transactions of the Society of Information Storage Systems
    • /
    • v.1 no.1
    • /
    • pp.78-83
    • /
    • 2005
  • The Blu-ray disc as a next generation high density optical medium uses an objective lens of high numerical aperture(NA 0.85) and blue laser in order to increase the recording density. The double layer is also useful for doubling the density. The spherical aberration of Blu-ray disc is very sensitive to the thickness of the disk because of high numerical aperture. This paper suggests a method to compensate the spherical aberration caused by the change of disk thickness, by using the Liquid Crystal lens instead of the Liquid Crystal panel. It was possible to develop both the LC panel generating the optical phase difference and LC lens changing the optical power. In this paper, we analyzed the aberration performance and a position sensitivity of the two type LC elements when the samples deviate from the optical axis of the objective lens. The results of applying this analysis show that the LC lenses rather than the LC panels have a significant assembling tolerance. The theoretical characteristics of the two elements are calculated and compared with the measurement data.

  • PDF

A COMPARISON OF FLUORESCENCE EFFECT OF VARIOUS LIGHT SOURCES IN EARLY ENAMEL CARIES (초기 우식 병소에서 광원에 따른 형광효과 비교)

  • Jeon, Jeong-Hoon;Lee, Nan-Young;Lee, Chang-Seop;Lee, Sang-Ho
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.32 no.4
    • /
    • pp.611-619
    • /
    • 2005
  • The aim of this study was to apply the quantitative light-induced fluorescence(QLF) and use of fluorescein-enhanced QLF method for quantitative assessment of early enamel demineralization in vitro, comparing effectiveness of light sources : argon laser, halogen lamp, light emitting diode (LED) and plasma arc lamp. Sixty extracted teeth were used, prepared by gentle pumicing and coating in an acid-resistant nail-varnish, except for an exposure to a demineralizing solution. Teeth were removed at regular intervals (24, 48 and 72hrs), air-dried and QLF image were taken. Mineral loss, as measured by difference of optical density, was recorded. For dyeenhanced QLF a 0.075% sodium fluorescein dye was applied after QLF examination and mineral loss was recorded. The following result were obtained : 1. Comparing with mean difference of optical density, plasma arc lamp was higher than other light sources in all group (p<0.05). 2. Comparing each group with mean difference of optical density, there was significant different using plasma are lamp and halogen lamp. 3. For use of dye-enhanced QLF, comparing with mean difference of optical density, plasma arc lamp were higher than other light sources in all group(p<0.05). 4. With this model dye-enhanced QLF compared with QLF in optical density, dye-enhanced QLF was higher than QLF in optical density. From the results presented in this paper, it was concluded that plasma light source was more effective compared with other light source for the detection and the quantification of early enamel caries.

  • PDF

Vascular Morphometric Changes During Tumor Growth and Chemotherapy in a Murine Mammary Tumor Model Using OCT Angiography: a Preliminary Study

  • Kim, Hoonsup;Eom, Tae Joong;Kim, Jae Gwan
    • Current Optics and Photonics
    • /
    • v.3 no.1
    • /
    • pp.54-65
    • /
    • 2019
  • To develop a biomarker predicting tumor treatment efficacy is helpful to reduce time, medical expenditure, and efforts in oncology therapy. In clinics, microvessel density using immunohistochemistry has been proposed as an indicator that correlates with both tumor size and metastasis of cancer. In the preclinical study, we hypothesized that vascular morphometrics using optical coherence tomography angiography (OCTA) could be potential indicators to estimate the treatment efficacy of breast cancer. To verify this hypothesis, a 13762-MAT-B-III rat breast tumor was grown in a dorsal skinfold window chamber which was applied to a nude mouse, and the change in vascular morphology was longitudinally monitored during tumor growth and metronomic cyclophosphamide treatment. Based on the daily OCTA maximum intensity projection map, multiple vessel parameters (vessel skeleton density, vessel diameter index, fractal dimension, and lacunarity) were compared with the tumor size in no tumor, treated tumor, and untreated tumor cases. Although each case has only one animal, we found that the vessel skeleton density (VSD), vessel diameter index and fractal dimension (FD) tended to be positively correlated with tumor size while lacunarity showed a partially negative correlation. Moreover, we observed that the changes in the VSD and FD are prior to the morphological change of the tumor. This feasibility study would be helpful in evaluating the tumor vascular response to treatment in preclinical settings.

Measuring of the Perceptibility and Acceptability in Various Color Quality Measures

  • Kim, A-Ri;Kim, Hong-Suk;Park, Seung-Ok
    • Journal of the Optical Society of Korea
    • /
    • v.15 no.3
    • /
    • pp.310-317
    • /
    • 2011
  • Perceptibility and acceptability are the most often used threshold units in the field of color science. The former refers to a just perceptible difference and the latter evokes a tolerable color difference. Such thresholds can be very significant to color quality control processes in the printing industry and should be defined in quality measure units. Optical density (OD) and color difference models are usually utilized as color quality measures and have been provided in a considerable number of commercial measuring devices such as spectrophotometers. However, their merits and traits are far less understood in the literature. The present study intends to evaluate performance of those color quality measures including the OD and widely known color difference models, e.g. ${\Delta}E{^*}_{ab}$, ${\Delta}E_{CMC(l:c)}$ and ${\Delta}E{^*}_{00}$. A set of psychophysical assessments were carried out in order to accumulate the perceptibility and acceptability thresholds data, and their central trend was compared with the color quality measure estimates.

Development of the 3-Axis Ultra-slim Actuator for Optical Disc Drives (광디스크 드라이브용 3축 초박형 액츄에이터 개발)

  • 김세원;조태민;윤영복;신경식;임경화
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2003.11a
    • /
    • pp.208-213
    • /
    • 2003
  • A note-book PC has become thinner in recent years. And optical disc drives are required to have high memory capacity. Therefore, the actuator of optical disc drives must be thinner and have disc tilt compensation function for high density memory. In this paper, the hybrid type actuator is investigated for 3-axis ultra-slim actuator. A 3-axis ultra-slim actuator is designed by using the modal analysis of the actuator and the electromagnetic analysis of magnetic circuit to achieve dynamic characteristics and magnetic flux density for high sensitivity, respectively. Also, magnetic force between tilt magnet and tilt yoke is investigated to find the influence on the DC sensitivity in the focus and track directions.

  • PDF

Composition Dependence and Optical Properties of Polymethyl Methacrylate/Alumina Nanocomposite in the IR Region Determined by Kramers-Kronig Relation

  • Ghamari, Misagh;Ghasemifard, Mahdi
    • Journal of the Korean Ceramic Society
    • /
    • v.54 no.2
    • /
    • pp.102-107
    • /
    • 2017
  • The dependence of the IR optical properties of PMMA/$Al_2O_3$ nanocomposite on the alumina content was investigated in the wavelength range of $3500-2800cm^{-1}$. The samples were prepared via emulsion polymerization technique using oleic acid as a coupling agent. Grafting density calculations were carried out by means of elemental analysis CHN to yield the best coupling agent content. FTIR analysis confirmed the existence of a chemical bond between aluminum oxide and oleic acid. The outcomes of XRD analyses showed the presence of cubic gamma aluminum oxide in the nanocomposite, in contrast to the amorphous nature of PMMA. TEM images showed the core-shell morphology of the particles other than pristine PMMA. Optical constants of the nanocomposite were calculated based on FTIR spectra and the Kramers-Kronig equations. The presence of nano alumina modified some of the optical indexes in IR region.