• Title/Summary/Keyword: optical density

Search Result 1,822, Processing Time 0.028 seconds

Development of an Optical Tissue Clearing Laser Probe System

  • Yeo, Changmin;Kang, Heesung;Bae, Yunjin;Park, Jihoon;Nelson, J. Stuart;Lee, Kyoung-Joung;Jung, Byungjo
    • Journal of the Optical Society of Korea
    • /
    • v.17 no.4
    • /
    • pp.289-295
    • /
    • 2013
  • Although low-level laser therapy (LLLT) has been a valuable therapeutic technology in the clinic, its efficacy may be reduced in deep tissue layers due to strong light scattering which limits the photon density. In order to enhance the photon density in deep tissue layers, this study developed an optical tissue clearing (OTC) laser probe (OTCLP) system which can utilize four different OTC methods: 1) tissue temperature control from 40 to $10^{\circ}C$; 2) laser pulse frequency from 5 to 30 Hz; 3) glycerol injection at a local region; and 4) a combination of the aforementioned three methods. The efficacy of the OTC methods was evaluated and compared by investigating laser beam profiles in ex-vivo porcine skin samples. Results demonstrated that total (peak) intensity at full width at half maximum of laser beam profile when compared to control data was increased: 1) 1.21(1.39)-fold at $10^{\circ}C$; 2) 1.22 (1.49)-fold at a laser pulse frequency of 5 Hz; 3) 1.64 (2.41)-fold with 95% glycerol injection; 4) 1.86 (3.4)-fold with the combination method. In conclusion, the OTCLP system successfully improved the laser photon density in deep tissue layers and may be utilized as a useful tool in LLLT by increasing laser photon density.

A study on the control method of the high density optical disk drive (고밀도용 광디스크 드라이브의 제어기술에 관한 연구)

  • Bae, Hong-Moon;Choi, Hyun-Taek;Suh, Il-Hong;Jung, Hong-Sang
    • Proceedings of the KIEE Conference
    • /
    • 1999.07b
    • /
    • pp.1009-1012
    • /
    • 1999
  • Recently, there is a strong need of DVD (Digital Versatile Disk) system of high density. high speed, and high accuracy System performances mostly depend on not only optical system, but also servo technology to drive it. Therefore, we investigate main technology concerned with optical pick-up unit based on 4.7GB DVD-RAM and analyzes technology of optical and servo systems that are required for high density high speed and high accuracy from the viewpoint of control. And then, we design a linear controller based on specification of 4.7GB DVD-RAM that is commercially available now. We analyze the dynamic characteristics of optical system that is coupled with control system and verify effect on performance indices of servo due to Parameter variation of pick-up by simulation. Finally, we will propose controller design specifications and provide direction of technical development for servo system and problems coupled with high capacity for 15GB level in the future.

  • PDF

Electrical & Optical Properties of Ion Implanted MPPO (Modified-Polyphenylene Oxide)

  • 임석진;김옥경;장동욱;이재상;하장호;최병호;이재형
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2000.02a
    • /
    • pp.189-189
    • /
    • 2000
  • 고분자 재료에 이온을 주입함으로서 경도, 내마모, 내피로성의 기계적인 특성과 내부식성 등의 화학적 특성이 향상되며, 표면 전기전도도와 광학밀도(optical density)가 변한다. 본 연구에서는 MPPO(Modified-Polyphenlene Oxide) 표면에 N2, Ar, Xe 이온을 에너지 50keV, 선량(dose)을 1$\times$1015에서 1$\times$1017ions/cm2로 증가시키면서 조사하였다. 이온 조사량의 증가에 따라 표면 저항이 2$\times$1015에서 6$\times$106($\Omega$/$\square$)으로 감소하여 표면 전기전도도가 향상되었다. Ar 이온은 1016ion/cm2이하의 조사량(dose)에서 N2보다 표면 저항을 더 많이 감소하는데 반해 1016ion/cm2 이상의 조사량에서는 Ar과 N2의 표면 저항이 비슷한 값을 나타냈다. Xe은 Ar과 N2이온에 비하여 전체적으로 표면저항이 많이 감소하여 전도도의 향상은 Xe, Ar, N2 순서로 질량이 큰 이온이 조사 효과가 큰 것으로 나타났다. 소재 표면은 SIMS 분석을 통하여 깊이에 따른 주입이온의 분포를 관찰하였으며, 표면 색상은 황색에서 갈색을 거쳐 암갈색으로 변화함으로서 가시광선에 대한 반사율(reflectance)이 감소하고 광학밀도(optical density)가 증가하여 광학적 특성이 변하였다. 이온 주입 후 에너지 전이에 의한 효과는 optical gap를 감소시켜 광학밀도(optical density)와 표면 전기 전도도를 증가시킨다. 이에 따라 본 논문에서는 이온주입에 의한 광학적, 전기적 특성간의 상관관계를 밝히고자 한다.

  • PDF

Design Parameters of Optical Pickup Actuator for the Next Generation (차세대 광 픽업 구동기를 위한 설계 변수)

  • Han, Chang-Soo;Kim, Soo-Hyun
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.18 no.1
    • /
    • pp.82-88
    • /
    • 2001
  • The demands of high data transfer rate and high recording density in optical disk memory device are being increased. In this paper, 4 design parameters for next generation optical disk are investigated. As for the high data transfer rate, two design parameters such as driving acceleration and transmissibility are introduced. As the high recording density is concerned, the minimum linearity and the tilt of the actuator are introduced. Two kinds of pickup actuator are used to evaluate the validity of the parameters through the simulation and the experiment. The 4-wire actuator has good linearity but bad stability and tilt characteristics, while the rotary and axis actuator has good stability for the external vibration but bad linearity. It is demonstrated that the newly proposed design parameters are available to design and evaluate quantitatively the performance of the actuator for the next generation optical disk.

  • PDF

Structural, Optical and Photoconductive Properties of Chemically Deposited Nanocrystalline CdS Thin Films

  • Park, Wug-Dong
    • Transactions on Electrical and Electronic Materials
    • /
    • v.12 no.4
    • /
    • pp.164-168
    • /
    • 2011
  • Nanocrystalline cadmium sulphide (CdS) thin films were prepared using chemical bath deposition (CBD), and the structural, optical and photoconductive properties were investigated. The crystal structure of CdS thin film was studied by X-ray diffraction. The crystallite size, dislocation density and lattice constant of CBD CdS thin films were investigated. The dislocation density of CdS thin films initially decreases with increasing film thickness, and it is nearly constant over the thickness of 2,500 ${\AA}$. The dislocation density decreases with increasing the crystallite size. The Urbach energies of CdS thin films are obtained by fitting the optical absorption coefficient. The optical band gap of CdS thin films increases and finally saturates with increasing the lattice constant. The Urbach energy and optical band gap of the 2,900 A-thick CdS thin film prepared for 60 minutes are 0.24 eV and 2.83 eV, respectively. The activation energies of the 2,900 ${\AA}$-thick CdS thin film at low and high temperature regions were 14 meV and 31 meV, respectively. It is considered that these activation energies correspond to donor levels associated with shallow traps or surface states of CdS thin film. Also, the value of ${\gamma}$ was obtained from the light transfer characteristic of CdS thin film. The value of ${\gamma}$ for the 2,900 A-thick CdS thin film was 1 at 10 V, and it saturates with increasing the applied voltage.

Measurement of Hydroxyl Radical Density at Bio-Solutions Generated from the Atmospheric Pressure Non-Thermal Plasma Jet

  • Kim, Yong Hee;Hong, Young June;Uhm, Han Sub;Choi, Eun Ha
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2013.02a
    • /
    • pp.494-494
    • /
    • 2013
  • Atmospheric pressure non-thermal plasma of the needle-typed interaction with aqueous solutions has received increasing attention for their biomedical applications [1]. In this context, surface discharges at bio-solutions were investigated experimentally. We have generated the non-thermal plasma jet bombarding the bio-solution surface by using an Ar gas flow and investigated the emission lines by OES (optical emission spectroscopy) [2]. Moreover, The non-thermal plasma interaction with bio-solutions has received increasing attention for their biomedical applications. So we researched, the OH radical density of various biological solutions in the surface by non-thermal plasma were investigated by Ar gases. The OH radical density of DI water; deionized water, DMEM Dulbecco's modified eagle medium, and PBS; 1x phosphate buffered saline by non-thermal plasma jet. It is noted that the OH radical density of DI water and DMEM are measured to be about $4.33{\times}1016cm-3$ and $2.18{\times}1016cm-3$, respectively, under Ar gas flow 250 sccm (standard cubic centimeter per minute) in this experiment. The OH radical density of buffer solution such as PBS has also been investigated and measured to be value of about $2.18{\times}1016cm-3$ by the ultraviolet optical absorption spectroscopy.

  • PDF