• Title/Summary/Keyword: optic sensor

Search Result 617, Processing Time 0.024 seconds

Fiber optic 산소센서를 이용한 생물공정의 모니터링

  • Lee, Jong-Il;Comte, Andreas;Hung, Lam Tuan;Kim, Jun-Hong
    • 한국생물공학회:학술대회논문집
    • /
    • 2000.04a
    • /
    • pp.569-571
    • /
    • 2000
  • A fiber optic oxygen sensor has been employed to monitor the concentrations of dissolved oxygen in a bioreactor. The characteristics of fiber optic oxygen sensor was investigated, e.g. the dependency of agitation rate on the oxygen measurement and also the dependence of temperature on the performance of fiber optic oxygen sensor etc. We have also applied to monitor the concentrations of dissoved oxygen in real cultivation processes by using the fiber optic oxygens sensor. The fiber optic oxygen sensor can be applied to measure the concentration of metabolites by immobilizing some enzymes, e.g. glucose oxidase and also employed for the environmental technology.

  • PDF

Sound Measurements of the Discharge Break Down Using Fabry-Perot Sensor Array (Fabry-Perot형 광섬유 배열센서의 방전 음압 계측)

  • Lee, Jong-Kil;Lee, June-Ho;Lee, Jin-Woo
    • Proceedings of the KSME Conference
    • /
    • 2003.04a
    • /
    • pp.770-773
    • /
    • 2003
  • To measure discharge breakdown acoustic signal, Fabry-Perot interferometer fiber optic sensor is used. Fiber optic sensor array can measure the partial discharge acoustic signal caused by defect of power facilities such as power cables, transformers and gas insulation. Fabry-Perot interferometer is selected as an fiber optic sensor array. It is shown that Fabry-Perot fiber optic sensor array detected discharge breakdown acoustic signal, effectively.

  • PDF

Design of Distributed Fiber Optic Sensor Net for the Detection of External Sound Frequency (외부 음향 주파수 탐지를 위한 분포형 광섬유 센서망 설계)

  • 이종길
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2003.11a
    • /
    • pp.792-796
    • /
    • 2003
  • In this paper, to detect external sound frequency on the latticed structure, fiber optic sensor net using Sagnac interferometer was fabricated and tested. The latticed structure fabricated with dimension of 50cm in width and 50cm in height, the optical fiber, 50m in length, distributed and fixed on the latticed structure. Single mode fiber, a laser with 1,550nm in wavelength, 2${\times}$2 coupler were used. External sound signal applied to the fiber optic sensor net and the detected optical signals were compared and analyzed to the detected microphone signals against time and frequency domain. Based on the experimental results, fiber optic sensor net using Sagnac interferometer detected external sound frequency, effectively. This system can be expanded to the structural health monitoring system.

  • PDF

Detection of External Sound Frequency by Using the Distributed Fiber Optic Sensor Net (분포형 광섬유 센서망을 이용한 외부 음향 주파수 탐지)

  • 이종길
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.14 no.7
    • /
    • pp.569-576
    • /
    • 2004
  • In this paper, to detect external sound frequencies on the latticed structure, fiber optic sensor net using Sagnac interferometer was fabricated and tested. The latticed structure was fabricated with a dimension of 50 cm in width and 50 cm in height. The optical fiber of 50m in length was distributed and fixed on the surface of the latticed structure. Single mode fiber, a laser with 1,550 nm in wavelength, 2 ${\times}$ 2 coupler were used. External sound signal, 240 Hz, 495 Hz, 1.445 kHz, 2k Hz, applied to the fiber optic sensor net and the detected optical signals were compared to the detected microphone signals against time and frequency domains. Based on the experimental results, fiber optic sensor net using Sagnac interferometer detected external sound frequency, effectively. This system can be expanded to the structural health monitoring system.

Experimental Analysis of Flow Induced Vibration Measurement Using Fiber Optic Sensor (광섬유 센서를 이용한 유체유기진동의 실험적 측정 연구)

  • Lee, Jongkil
    • 대한공업교육학회지
    • /
    • v.34 no.1
    • /
    • pp.274-286
    • /
    • 2009
  • Fiber optic sensor is widely used in measuring acoustic and vibration. Especially interferometric sensors are more suitable to measure the acoustic signal. In this paper, a Fabry-Perot interferometric fiber optic sensor was used to measure flow induced vibration. This vibration also measured using an accelerometer, and the data was compared to one other. The venture, nozzle, drop barrel, and rapid expansion in the pipeline are the measuring objects. The flow rate is changed from 50 L/min to 150 L/min and the average flow velocity was about 7 m/s. Based on the experimental results the suggested fiber optic sensor detects flow induced vibration effectively. Therefore, this kind of fiber optic sensor can be applied to the monitoring the flow induced noise and vibration such as pipelines, cables, buildings.

Strain Sensitivity of Fiber Optic Bragg Grating Sensor (광섬유 브래그 격자 센서의 변형률 감지도)

  • Kwon, Il-Bum;Choi, Man-Yong;Kim, Min-Soo
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.3 no.3
    • /
    • pp.237-243
    • /
    • 1999
  • Recently, there has been considerable interest in the development of fiber-optic sensors based on fiber Bragg gratings (FBGs), which can be made into Ge-doped fiber's core by UV phase mask or holographic methods. A good sensitivity and small size of this sensor make it an ideal candidate for distributed sensing in smart structures or other structural monitoring applications. In this study, fiber optic Bragg grating sensor, which could be applied to measure the absolute strains, was constructed and the strain sensitivity of this sensor was investigated in order to apply to the structural health monitoring. Fiber Fabry-Perot (FFP) filter has been used to detect the optical signals instead of optical spectrum analyzer. It has been convenient to determine the structural strains from the output signal of FBGs. The fiber optic Bragg grating sensor was attached on the aluminum beam near the electrical strain gage to measure the same strain. The relationship between strain and fiber signal was linearly fitted. The strain sensitivity of the fiber optic Bragg grating sensor was determined as $l.57{\mu}{\varepsilon}/{\mu}sec$ from the aluminum beam test.

  • PDF

Operating Characteristic Analysis of Optic Temperature Sensor for Overheat Detection in Panel Board (분전함에서 이상발열 감지를 위한 광온도센서의 동작특성 분석)

  • Moon, Hyun-Wook;Kim, Dong-Woo;Gil, Hyung-Jun;Kim, Dong-Ook;Lee, Ki-Yeon;Kim, Hyang-Kon
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.23 no.10
    • /
    • pp.100-106
    • /
    • 2009
  • In this study, methods of overheat detection at the coupling or wire in electrical facility are investigated, operating characteristic about the optic temperature sensor for continuous on-line temperature monitoring in diagnostics system of electrical facility is analyzed. Heating sources in the experiment for operating characteristics of optic temperature sensor use black body and hot plate, output voltage of optic temperature sensor in accordance with temperature variation is analyzed. Overheat generation due to poor contact at the circuit breaker in panel board detects using a thermocouple, infrared thermal camera and optic temperature sensor, and experiment results are analyzed. The effect of optic temperature sensor is the same that of other methods. These results expect to use basic research material for adjusting field of electrical diagnostics system using RFID type optic temperature sensor in the near future.

Fiber Optic Gyroscope using IOC (IOC를 사용한 광파이버 자이로)

  • Kim, In-Soo S.;Kim, Yo-Hee
    • Proceedings of the KIEE Conference
    • /
    • 1998.07e
    • /
    • pp.1843-1845
    • /
    • 1998
  • Gyroscope is a very important core sensor as a rotation sensor in inertial space, in inertial guidance and navigation system on aeronautics. Plane, vessel and so on for civilian and millitary applications. Research and development of fiber optic gyroscope began in 1976 and focused on improving the gyroscope's sensitivity to rotation. bias performance and reducing noise. We have developed a Interferometric Fiber Optic' Gyroscope using a integrated-optic-circuit (IOC), which is operating with closed-loop electronic circuit. This paper describes the scheme of optical part and electronic part and also test results of this fiber optic gyroscope using a integrated-optic-circuit (IOC). The performance have been achieved as long-term bias drift of $1.73^{\circ}/h$.

  • PDF

Application of a fiber optic TR-EEPI sensor to detect deformation and failure in composite materials (복합재료의 변형 및 파손탐지를 위한 광섬유 TR-EFPI 센서의 적용)

  • 박래영;권일범;최낙삼
    • Proceedings of the Korean Society For Composite Materials Conference
    • /
    • 2002.05a
    • /
    • pp.31-34
    • /
    • 2002
  • A study on the method that can measure the internal strain of composite materials is performed to monitor the health status of composite structures. A fiber optic sensor was constructed using the total reflected extrinsic Fabry-Perot interferometer(TR-EFPI) probe with a broadband light source. Result obtained from electrical strain gage adhered on the aluminum beam specimen was compared with that from the fiber optic TR-EFPI sensor and showed a good agreement. It was found that fiber optic TR-EFPI sensor system was adequate for monitoring the strain and thus failure processes in the interior of composite materials.

  • PDF

Development of Underground Displacement and Convergence Auto-Measuring Program for the Tunnel Using the Fiber Optic Sensor (광섬유 센서를 이용한 터널 지중 및 내공변위 자동계측 프로그램 개발)

  • Choi, Myong-Ho;Yoon, Ji-Son;Kwon, Oh-Duk;Kwon, Oh-Jun
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2005.03a
    • /
    • pp.1361-1368
    • /
    • 2005
  • In this paper, the theoretical method of measuring the tunnel convergence and underground displacement, the objective indices of assessing safety for tunnel construction, using the fiber optic sensor is studied by developing the program to automatically measure them. The model test of Con'c beam is conducted to evaluate reliability of the fiber optic sensor. Furthermore, using the RS232 communication protocol as well as Visual C# and Visual C++, the programming tools, the program was developed to detect automatically the measured value of the fiber optic sensor, calculate the tunnel convergence and underground displacement, predict the deformed shape of the tunnel, and evaluate loosening zone due to the tunnel excavation.

  • PDF