• 제목/요약/키워드: optic flow

검색결과 61건 처리시간 0.025초

티타늄 이소프로폭사이드를 이용한 졸-겔법에 의한 TiN 코팅 cBN 분말 합성 (Synthesis of TiN-Coated cBN Powder by Sol-Gel Method Using Titanium (IV) Isopropoxide)

  • 이윤성;김선욱;이영진;이지선;신동욱;김세훈;김진호
    • 한국전기전자재료학회논문지
    • /
    • 제33권5호
    • /
    • pp.373-379
    • /
    • 2020
  • In this study, TiN-coated cBN (cubic-structure boron nitride) powders were successfully synthesized by a sol-gel method using titanium (IV) isopropoxide (TTIP) and by controlling the heat treatment conditions. After the sol-gel process, amorphous nano-sized TiOx was uniformly coated on the surface of cBN powder particles. The obtained TiOx-coated cBN powders were heated at 1,000~1,300℃ for 1 or 6 h in a flow of 95%N2-5%H2 mixed gas. With increasing temperature, the chemical composition of the TiOx coating layer changed in the order of TiO2→Ti6O11→Ti4O7→TiN due to reduction of the Ti ions. The TiN coating layer was observable in the samples heated at 1,200℃ and appeared as the main phase in the sample heated at 1,300℃. The resulting thickness of the TiN coating layer of the sample heated at 1,300℃ was approximately 45~50 nm.

온도 모니터링을 위한 광섬유 센서와 온도센서 배열 케이블의 비교 연구 (A Study on the Comparison between an Optical Fiber and a Thermal Sensor Cable for Temperature Monitoring)

  • 김중열;김유성;송윤호
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2006년도 춘계 학술발표회 논문집
    • /
    • pp.1100-1109
    • /
    • 2006
  • In this study, two different technologies which can measure temperature simultaneously at many points are introduced. One is to use a thermal sensor cable that is comprised of addressable thermal sensors connected in parallel within a single cable. The other is to use an optic fiber with Distributed Temperature Sensing (DTS) system. The difference between two technologies can be summarized as follows. A thermal sensor cable has a concept of 'point sensing' that can measure temperature at accurate position of a thermal sensor. So the accuracy and resolution of temperature measurement are up to the ability of the thermal sensor. Whereas optic fiber sensor has a concept of 'distributed sensing' because temperature is measured by ratio of Stokes and anti-Stokes component intensities of Raman backscatter that is generated when laser pulse travels along an optic fiber. It's resolution is determined by measuring distance, measuring time and spatial resolution. The purpose of this study is that application targets of two temperature measurement techniques are checked in technical and economical phases by examining the strength and weakness of them. Considering the functions and characteristics of two techniques, the thermal sensor cable will be suitable to apply to the assessment of groundwater flow, geothermal distribution and grouting efficiency within 300m distance. It is expected that the optic fiber sensor can be widely utilized at various fields (for example: pipe line inspection, tunnel fire detection, power line monitoring etc.) which need an information of temperature distribution over relatively long distance.

  • PDF

Y2O3와 Fe2O3가 포함된 LAS 계 결정화 유리 특성 (The properties of glass ceramic of LAS system with Y2O3 and Fe2O3)

  • 이지선;임태영;황종희;이영진;전대우;김선욱;라용호;김진호
    • 한국결정성장학회지
    • /
    • 제29권4호
    • /
    • pp.154-159
    • /
    • 2019
  • 용융 온도를 낮추고 균질화에 영향을 줄 수 있는 yttrium oxide(산화 이트륨)과 iron oxide(산화철)를 사용하여 $LI_2O-Al_2O_3-SiO_2$ 계 결정화 유리를 제조하였다. 조핵제는 Zirconium sulfate(황산지르코늄)을 사용했고, 유리 점도를 낮추기 위해 calcium phosphate(인산칼슘)을 사용해 유리 유동성을 원활하게 하였다. 결정화 유리는 열충격 $750^{\circ}C$ 이상을 만족했고, $800^{\circ}C$ 이상에서 열팽창계수가 급격하게 상승하는 온도를 약 $30^{\circ}C$ 이상 시프트 하였다. 따라서 yttrium oxide와 iron oxide 포함하는 LAS 계 유리는 고온에서 양호한 용융 상태와 우수한 열팽창 저항성을 확인하였고 특수 주방용 재료 분야에 충분히 활용이 가능하리라 판단되었다.

기포흐름 측정을 위한 영상기법 및 광섬유센서 적용 (Application of Image Technique and Optical Fiber Sensor for Air-water Mixture Flow)

  • 류용욱;정태화
    • 한국수자원학회논문집
    • /
    • 제48권7호
    • /
    • pp.535-543
    • /
    • 2015
  • 기포가 포함된 다상흐름의 측정은 중요함에도 불구하고 많은 제약이 있었다. 특히, 공극률이 높은 다상 흐름은 밀도차의 급격한 변화와 두꺼운 공기-물 경계면으로 인해 측정이 매우 어렵다. 본 연구에서는 공극률에 상관없이 기포흐름을 측정할 수 있는 기포영상유속측정법과 다발 광섬유유동측정계를 소개하고자 한다. 기포영상측정기법의 경우, 화상측정시 발생하는 원근에 의한 오차를 최소화하고 추정할 수 있는 피사계 심도에 대한 계산방법을 제시하여 정도 분석을 위한 방안을 제시하였다. 다발 광섬유유동측정계는 얇은 광섬유의 특성을 이용해 다발로 제작하여 측정률을 증가시키고자 하였다. 제시된 두 기법을 기포플룸에 적용하여 신뢰도를 검토하였으며 잘 일치하는 것을 확인하였다. 소개된 기법으로 대표적인 하천 다상흐름인 도수흐름을 측정하여 그 적용성을 검토하였다.

Development a glucose-FIA system with a fiber optic oxygen sensor

  • Sohn, Ok-Jae;Lam, Tuan-Hung;Rhee, Jong-Il
    • 한국생물공학회:학술대회논문집
    • /
    • 한국생물공학회 2005년도 생물공학의 동향(XVII)
    • /
    • pp.730-734
    • /
    • 2005
  • 본 연구에서는 광섬유 산소센서를 기반으로 글루코오스 모니터링용 FIA 시스템을 개발하였다. 운반용액의 낮은 유속에서도 검출가능 하였으며, 산소전극을 이용한 글루코오스-FIA 시스템보다 넓은 범위의 글루코오스 농도를 검출할 수 있었다. 향후, 광섬유 센서를 이용하여 생물반응기에서 기질로 사용되는 글루코오스뿐만 아니라 용존산소, pH, $CO_2$와 같이 다양한 인자들의 모니터링 시스템을 개발하고자 한다.

  • PDF

Development of Respiration Sensors Using Plastic Optical Fiber for Respiratory Monitoring Inside MRI System

  • Yoo, Wook-Jae;Jang, Kyoung-Won;Seo, Jeong-Ki;Heo, Ji-Yeon;Moon, Jin-Soo;Park, Jang-Yeon;Lee, Bong-Soo
    • Journal of the Optical Society of Korea
    • /
    • 제14권3호
    • /
    • pp.235-239
    • /
    • 2010
  • In this study, we have fabricated two types of non-invasive fiber-optic respiration sensors that can measure respiratory signals during magnetic resonance (MR) image acquisition. One is a nasal-cavity attached sensor that can measure the temperature variation of air-flow using a thermochromic pigment. The other is an abdomen attached sensor that can measure the abdominal circumference change using a sensing part composed of polymethyl-methacrylate (PMMA) tubes, a mirror and a spring. We have measured modulated light guided to detectors in the MRI control room via optical fibers due to the respiratory movements of the patient in the MR room, and the respiratory signals of the fiber-optic respiration sensors are compared with those of the BIOPAC$^{(R)}$ system. We have verified that respiratory signals can be obtained without deteriorating the MR image. It is anticipated that the proposed fiber-optic respiration sensors would be highly suitable for respiratory monitoring during surgical procedures performed inside an MRI system.

Gas-Flow Sensor using Optical Fiber Bragg Grating(FBG)

  • Shim, Joon-Hwan;Cho, Seok-Je;Yu, Yung-Ho;Sohn, Kyung-Rak
    • 한국항해항만학회지
    • /
    • 제32권9호
    • /
    • pp.717-722
    • /
    • 2008
  • We have proposed and demonstrated an gas-flow sensor using optical fiber bragg grating(FEG). The flow sensor has no electronics and no mechanical parts in its sensing part and the structure is th11s simple and immune to electromagnetic interference(EMI). The FEG sensor was consisted qf the sensing element and a coil heater. The metal coil was used to supply the current to the FEG. While some currents supply to the coil, the refractive index of the FEG under the coil is changed and thus the wavelength shift of fiber optic sensor was induced In this work, the wavelength shift according to flow-rate was experimentally studied and was used to evaluate the gas flow-rate in a gas tube. As a result, it was possible to measure the flow-rate in a linear range from 5 to $20{\ell}/min$ with a resolution of approximately $1{\ell}/min$ at the applied currents of 100 mA and 120 mA. The measured sensitivities were $15.3\;pm/\ell/min$ for 100 mA and $20.2\;pm/\ell/min$ for 120 mA.

쇄파에 의한 월파의 기포분율에 대한 실험적 연구 (Experimental Study of Overtopping Void Ratio by Wave Breaking)

  • 유용욱;이종인
    • 한국해안·해양공학회논문집
    • /
    • 제20권2호
    • /
    • pp.157-167
    • /
    • 2008
  • 본 연구에서는 직립 구조물 전면에서 발생하는 권파에 의한 월파의 기포분율을 수리모형실험으로 검토하였다. 구조물 직립벽 전면에서 쇄파되는 내습파랑은 쇄파와 월파 과정동안 기포를 연행하거나 액적화되며 강한 난류세기를 갖는 다위상흐름이 된다. 본 연구에서는 광섬유반사율계와 기포를 이용한 영상유속계기법으로 월파의 기포분율, 유속, 그리고 층두께를 측정하였다. 반복된 실험으로 얻어진 기포분율과 유속은 조화평균과 시간평균을 적용하여 분석하였다. 평균된 기포분율의 분포로부터 높은 기포분율은 주로 월파수괴의 전면부에서 발생하는 것을 알 수 있었으며, 구조물 상단표면에 접한 영역과 월파수괴의 후면부 영역은 상대적으로 낮은 기포분율을 보여주었다. 측정된 월파의 기포분율, 유속, 그리고 층두께로부터 월파의 흐름율과 운동량을 산정하였고, 실험결과로부터 기포분율이 중요한 인자임을 알 수 있었다. 수심평균된 기포분율, 유속, 두께의 상사적 분포특성을 이용하여 경험식을 제시하였고, 1차원적 경험식을 이용하여 흐름율과 운동량을 검토하였다.

Convection in the growth of zinc telluride single crystal by physical vapor transport

  • Kim, Geug-Tae
    • 한국결정성장학회지
    • /
    • 제13권4호
    • /
    • pp.187-198
    • /
    • 2003
  • Zinc selenide (ZnSe) single crystals hold promise for many electro-optics, acousto-optic and green laser generation applications. This material is prepared in closed ampoules by the physical vapor transport (PVT) growth method based on the dissociative sublimation. We investigate the effects of diffusive-convection on the crystal growth rate of ZnSe with a low vapor pressure system in a horizontal configuration. Our results show that for the ratios of partial pressures, s=0.2 and 2.9, the growth rate increases with the Peclet number and the temperature differences between the source and crystal. As the ratio of partial pressures approaches the stoichiometric value of 2, the rate increases. The mass fluk based on one dimensional (1D model) flow for low vapor pressure system fall within the range of the predictions (2D model) obtained by solving the coupled set of conservation equations, which indicates the flow fields would be advective-diffusive. Therefore, the rate and the flow fields are independent of gravity acceleration levels.

최대유량역에서 소형 축류 홴의 3차원 난류유동 특성에 관한 연구 (A Study on the Three-Dimensional Turbulent Flour Characteristics of a Small-sized Axial Fan at the Maximum Flowrate Region)

  • 김장권
    • 동력기계공학회지
    • /
    • 제4권3호
    • /
    • pp.25-33
    • /
    • 2000
  • This study represents three-dimensional turbulent flow characteristics around an axial fan measured at the operating point ${\varphi}=0.32$, which is equivalent to the maximum flowrate region, by using three-dimensional fiber-optic type LDA system. This LDA system is composed of a 5 W Argon-ion laser, two optics in back-scatter mode, three BSA's, a PC, and a three-dimensional automatic traversing system. A kind of paraffin fog is used for laser particles in this study. Mean velocity profiles around an axial fan along the downstream radial distance show that the streamwise and the tangential components exist as a predominant velocity and have the maximum value at the radial distance ratio 0.8, while the radial component has a small scale distribution and its flow direction is inward except a part of blade tip. The turbulent intensity profiles show that the radial component exists the most greatly. And also the turbulent kinetic energy shows about 60% as a maximum value at the radial distance ratio 0.9. Moreover, the Reynolds shear stresses do not exist at upstream flow, but the streamwise and the radial components of them show about 20% as a maximum value at the radial distance ratio 0.9 at downstream flow.

  • PDF