• 제목/요약/키워드: optic

검색결과 2,442건 처리시간 0.032초

An Automated Fiber-optic Biosensor Based Binding Inhibition Assay for the Detection of Listeria Monocytogenes

  • Kim, Gi-Young;Morgan, Mark;Ess, Daniel;Hahm, Byoung-Kwon;Kothapalli, Aparna;Bhunia, Arun
    • Food Science and Biotechnology
    • /
    • 제16권3호
    • /
    • pp.337-342
    • /
    • 2007
  • Conventional methods for pathogen detection and identification are labor-intensive and take days to complete. Biosensors have shown great potential for the rapid detection of foodborne pathogens. Fiber-optic biosensors have been used to rapidly detect pathogens because they can be very sensitive and are simple to operate. However, many fiber-optic biosensors rely on manual sensor handling and the sandwich assay, which require more effort and are less sensitive. To increase the simplicity of operation and detection sensitivity, a binding inhibition assay method for detecting Listeria monocytogenes in food samples was developed using an automated, fiber-optic-based immunosensor: RAPTOR (Research International, Monroe, WA, USA). For the assay, fiber-optic biosensors were developed by the immobilization of Listeria antibodies on polystyrene fiber waveguides through a biotin-avidin reaction. Developed fiber-optic biosensors were incorporated into the RAPTOR to evaluate the detection of L. monocytogenes in frankfurter samples. The binding inhibition method combined with RAPTOR was sensitive enough to detect L. monocytogenes ($5.4{\times}10^7\;CFU/mL$) in a frankfurter sample.

시신경에 발생한 전이성 선세포암 - 증 례 보 고 - (Metastatic Adenocarcinoma of Optic Nerve - A Case Report -)

  • 김진용;박상근;김한성;신형식;황용순;김상진
    • Journal of Korean Neurosurgical Society
    • /
    • 제29권8호
    • /
    • pp.1069-1073
    • /
    • 2000
  • Although the most commonly encountered orbital tumor is metastatic tumor, adenocarcinoma of stomach metastasized to the optic nerve is rarely reported. The authors discuss a rare case of metastatic adenocarcinoma of left optic nerve with a review of literature. A 44-year-old man presented with decreased visual acuity of left eye for 3 months. Neurologic examination revealed left optic neuropathy. On MR imaging, a homogenously wellenhanced mass surrounding left optic nerve around optic canal was noticed. The X-rays and the whole body bone scan sho-wed multiple bony metastasis. Subtotal removal was performed via combined subfrontal and pterional approach and metastatic adenocarcinoma from the stomach was confirmed histologically. Postoperative course was uneventful, but there was no improvement of visual acuity.

  • PDF

구조물 음향진동 모니터링을 위한 광섬유 센서 설계 (Fiber Optic Sensor Design for the Monitoring of Structural Sound and Vibration)

  • 이종길
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2007년도 춘계학술대회논문집
    • /
    • pp.81-84
    • /
    • 2007
  • In this paper, fiber optic sound and vibration monitoring sensor which is latticed shape structure based on Sagnac interferometer is fabricated and tested in laboratory conditions. To detect external vibrations surface mounted fibers on the latticed steel wire fence with a dimension of 170cm by 180cm is used. To detect external sound frequency the tightened fiber optic itself wire netting fence with a dimension of 50cm by 50cm is used. Experiments for the detection of the excited vibration and sound signals were performed. A small vibrator induced external vibration signal and it is applied to the latticed structure in the range of 100Hz to several kHz. External sound signal applied to the fiber optic sensor net using non-directional sound speaker. The detected optical signals were compared and analyzed to the detected both accelerometer and microphone signals in the time and frequency domain. Based on the experimental results, distributed fiber optic sensor using Sagnac interferometer detected effectively external vibration and sound signal and had a good performance. This system can be expanded to the monitoring of a significant system and to the structural health monitoring system.

  • PDF

Current-induced Phase Demodulation Using a PWM Sampling for a Fiber-optic CT

  • Park, Hyoung-Jun;Lee, June-Ho;Kim, Hyun-Jin;Song, Min-Ho
    • Journal of the Optical Society of Korea
    • /
    • 제14권3호
    • /
    • pp.240-244
    • /
    • 2010
  • In this work, we used PWM sampling for demodulation of a fiber-optic interferometric current transformer. The interference signal from a fiber-optic CT is sampled with PWM triggers that produce a 90-degree phase difference between two consecutively sampled signals. The current-induced phase is extracted by applying an arctangent demodulation and a phase unwrapping algorithm to the sampled signals. From experiments using the proposed demodulation, we obtained phase measurement accuracy and a linearity error, in AC current measurements, of ~2.35 mrad and 0.18%, respectively. The accuracy of the proposed method was compared with that of a lock-in amplifier demodulation, which showed only 0.36% difference. To compare the birefringence effects of different fiber-optic sensor coils, a flint glass fiber and a standard single-mode fiber were used under the same conditions. The flint glass fiber coil with a Faraday rotator mirror showed the best performance. Because of the simple hardware structure and signal processing, the proposed demodulation would be suitable for low-cost over-current monitoring in high voltage power systems.

고속회전 감지 광섬유자이로 설계 (Design of Fiber Optic Gyroscope for Sensing High Rotation)

  • 도재철;정경호;조민식;송기원;문홍기
    • 한국항공우주학회지
    • /
    • 제37권6호
    • /
    • pp.551-555
    • /
    • 2009
  • 본 논문은 광섬유 간섭계의 제한된 회전 측정범위($\pi$/2[radian]) 확장을 통하여 고속 회전입력을 감지할 수 있는 광섬유자이로 설계에 관한 연구 결과를 기술하였다. 디지털 세로다인 변조 기법을 바탕으로 광섬유자이로 신호처리 회로를 설계하였으며, 제작된 프로토타입 광섬유자이로의 시험결과 약 ${\pm}3000[deg/sec]$의 고속 회전측정 성능과 약 150[ppm]의 환산계수 성능을 확인하였다. 따라서 본 논문에서는 고속회전 감지를 위한 광섬유자이로 설계의 유효성이 검증되었다.

Anterior Communicating Artery Aneurysm Related to Visual Symptoms

  • Park, Jung-Hyun;Park, Sang-Keun;Kim, Tae-Hong;Shin, Jun-Jae;Shin, Hyung-Shik;Hwang, Yong-Soon
    • Journal of Korean Neurosurgical Society
    • /
    • 제46권3호
    • /
    • pp.232-238
    • /
    • 2009
  • Objective : Intracranial aneurysms are sometimes presented with visual symptoms by their rupture or direct compression of the optic nerve. It is because their prevalent sites are anatomically located close to the optic pathway. Anterior communicating artery is especially located in close proximity to optic nerve. Aneurysm arising in this area can produce visual symptoms according to their direction while the size is small. Clinical importance of visual symptoms presented by aneurysmal optic nerve compression is stressed in this study. Methods : Retrospective analysis of ruptured anterior communicating artery aneurysms compressing optic apparatus were carried out. Total 33 cases were enrolled in this study. Optic nerve compression of the aneurysms was confirmed by the surgical fields. Results : In 33 cases among 351 cases of ruptured anterior communicating artery aneurysms treated surgically, from 1991 to 2000, the dome of aneurysm was compressed in optic pathway. In some cases, aneurysm impacted into the optic nerve that deep hollowness was found when the aneurysm sac was removed during operation. Among 33 cases, 10 cases presented with preoperative visual symptoms, such as visual dimness (5), unilateral visual field defect (2) or unilateral visual loss (3), 20 cases had no visual symptoms. Visual symptoms could not be checked in 3 cases due to the poor mental state. In 6 cases among 20 cases having no visual symptoms, optic nerve was deeply compressed by the dome of aneurysm which was seen in the surgical field. Of 10 patients who had visual symptoms, 8 showed improvement in visual symptoms within 6 months after clipping of aneurysms. In 2 cases, the visual symptoms did not recover. Conclusion : Anterior communicating artery aneurysm can cause visual symptoms by compressing the optic nerve or direct rupture to the optic nerve with focal hematoma formation. We emphasize that cerebral vascular study is highly recommended to detect intracranial aneurysm before its rupture in the case of normal CT findings with visual symptoms and frequent headache.

Sagnac형 광섬유 배열센서를 이용한 유증 음답 탐지 연구 (Investigation of the Acoustic Detection in Transformer Oil Using Sagnac Fiber Optic Sensor Array)

  • 이종길;이승홍
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2010년도 추계학술대회 논문집
    • /
    • pp.533-534
    • /
    • 2010
  • Fiber optic sensor has bee widely used in the industrial applications. For the application of acoustic detection of the high voltage electric transformer Sagnac interferometer can be used. In this paper several different materials of mandrel were used in the fiber sensor array. Based on the transformer oil fiber optic sensor is more sensitive than in the air.

  • PDF

MRI의 현황과 전망

  • 전희국
    • 대한의용생체공학회:의공학회지
    • /
    • 제9권1호
    • /
    • pp.125-130
    • /
    • 1988
  • In the conventional infrared imaging system, complex infrared lens systems are usually used for directing collimated narrow infrared beams into the high speed 2-dimensional optic scanner. In this paper, a simple reflective infrared optic system with a 2-dimensional optic scanner is proposed for the realization of medical infrared thermography system. It has been experimentally proven that the intfrared thermography system composed of the proposed optic system has the temperature resolution of $0.1^{\circ}C$ under the spatial resolution of lmrad, the image matrix size of $256 {\times} 240, $ and tile imaging time of 4 seconds.

  • PDF

다중화된 광 손실형 광섬유 센서에 의한 변위의 측정 (Displacement Measurement by Multiplexed Optical Loss -based Fiber Optic Sensor)

  • 권일범;김치엽;유정애
    • 한국전산구조공학회:학술대회논문집
    • /
    • 한국전산구조공학회 2003년도 가을 학술발표회 논문집
    • /
    • pp.556-565
    • /
    • 2003
  • Light losses in optical fibers are investigated by a fiber optic OTDR (Optical Time Domain Reflectometry) sensor system to develop fiber optic probes for structural displacement measurement. The displacement sensitivity was determined by the measurements of fiber-bending loss according to the gage length changes of the displacement sensor. The fiber optic displacement probe was manufactured to verify the feasibility of the structural displacement measurement.

  • PDF