• Title/Summary/Keyword: ophthalmic test

Search Result 279, Processing Time 0.02 seconds

Research on the Refractive State Screening in Preschool Children (취학전 아동의 굴절상태 실태조사)

  • Kim, Jeoung-Hee
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.6 no.2
    • /
    • pp.105-109
    • /
    • 2001
  • The investigate of preschool children at 7-year-old at three kindergartens in Iksan was done by the naked visual acuity, the refractive state and cover-uncover test. Total 246 eyes were examined by the objective and subjective methods. The results were as follows: 1. Among the 246 eyes, the naked visual acuity of below the average 0.7 was 64 eyes(26%). 2. As to the distribution of refractive errors, myopic eyes and hyperopic eyes were 26.55% and 26.55%, respectively. 3. As to the type of astigmatisms, with the rule was 85.8%, against the rule was 8.9% and oblique was 5.3%. 4. The percentage of preschool children who had been tested was 13.8%. 5. In test none of children were the phoria.

  • PDF

Case Study of Vision Therapy (시기능 교정의 임상사례)

  • Park, Hyun-Ju
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.11 no.1
    • /
    • pp.35-41
    • /
    • 2006
  • I performed the refraction and binocular test for study of binocular abnormalities. The problems of the accommodation and binocular on subjects was need to the correction of the refractive error. also the subjects was need to a specific treatment for each of the problems. On two patients who had convergence excess, The full corrections of eyeglasses or (+)ADD for near vision were prescribed and the subjects trained for 4 weeks. After 4 weeks, the unconvenience of near vision have more decrease, and the objective test have good results. On clinical, If the optical correction and vision therapy was applied the treatment for binocular abnormalities. The continuous research of vision training in binocular abnormalities will be good results for treatment of several binocular abnormalities in the future.

  • PDF

A Study on the Phoria of Korean Male and Female Adults (한국인 성인 남녀의 사위에 관한 연구)

  • Sung, Duk Yong
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.6 no.1
    • /
    • pp.59-63
    • /
    • 2001
  • Once refractive error of the eye was fully corrected. Polarization Test was used to investigate binocular vision function. As the results of phoria measurement of Korean adults for 53males and 59 females, orthophoria in 27.68%, esophoria in 12.50%, exophoria in 48.21%, verical phoria in 3.75%, esophoria(+verical phoria) in 2.68%, and exophoria(+vertical phoria) in 5.36%, respectively. Horizontal phoria is below $3{\Delta}$ mostly and verical phoria is below $1{\Delta}$.

  • PDF

A Study of Myopic Astigmatism Eyes on The Highschool Students (남녀고등학생의 근시성 난시안에 대한 연구)

  • Yoon, Kyoung-Han;Kang, Myung-Ki
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.5 no.1
    • /
    • pp.159-163
    • /
    • 2000
  • In this study, It obtained that how myopitic astigmatism eyes appear in highschool students. The results were as follows. 1. In test, myopitic astigmatism eyes of men students are measured 60% in ratio and women students are measured are 57% in ratio. 2. In $-1.00{\geq}$cyl>0.00 Dptr, myopitic astigmatism eyes are measured 82% in ratio and in $-1.50{\geq}$cyl>-1.00 that is measured 12% in ratio. 3. In -2.00>cyl, myopitic astigmatism eyes are measured 6% in ratio. 4. In the kind of astigmatism, The direct astigmatism axis is 81 % in ratio and each of the indirect astigmatism axis and the oblique astigmatism is 5%, 14% in ratio.

  • PDF

Fabrication and Processing Method of Ophthalmic Hydrogel Tinted Lens Containing Indium Tin Oxide-Composited Materials

  • Lee, Min-Jae;Lee, Kyung-Mun;Sung, A-Young
    • Korean Journal of Materials Research
    • /
    • v.28 no.12
    • /
    • pp.685-690
    • /
    • 2018
  • In this study, a multifunctional ophthalmic lens material with an electromagnetic shielding effect, high oxygen permeability, and high water content is tested, and its applicability is evaluated. Metal oxide nanoparticles are applied to the ophthalmic lens material for vision correction to shield harmful electromagnetic waves; the pyridine group is used to improve the antibacterial effect; and silicone substituted with urethane and acrylate is employed to increase the oxygen permeability and water content. In addition, multifunctional tinted ophthalmic lens materials are studied using lens materials with an excellent antibacterial effect (2,6-difluoropyridine, 2-fluoro-4-pyridinecarboxylic acid) and functional (UV protection, high wettability) lens materials (2,4-dihydroxy benzophenone, 2-hydroxy-4-(methacryloyloxy)benzophenone). To solve problems such as air bubbles generated during the polymerization process for the manufacturing and turbidity of the lens surface, polymerization conditions in which the defect rate is minimized are determined. The results show that the polymerization temperature and time are most appropriate when they are $110^{\circ}C$ and 40 minutes, respectively. The optimum injection amount of the polymerization solution is 350 ms. The turbid phenomenon that appears in lens processing is improved by 10 to 95 % according to the test time and conditions.

The Effect of Vision Training on Exophoria and Intermittent Extropia Using MYSTERY CIRCLE System (MYSTERY CIRCLE 시스템을 이용한 폭주부족형 사위 및 간헐성 사시 환자의 시기능 훈련 효과 연구)

  • Lee, Chang-Seon;Kim, Kun-Kyu;Jeon, Young-Ki;Kim, Kong-Ki;Choi, Chul-Hee;Kim, Ki-Hong
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.15 no.4
    • /
    • pp.373-379
    • /
    • 2010
  • Purpose: The purpose of this study was to investigate the effect of vision training using MYSTERY CIRCLE system on patients with exophoria and intermittent extropia. Mehtods: The vision training observation group consists of 26 clients who had exophoria (n=18) and intermittent extropia (n=8) without opthalmic diseases or vertical phoria. Our clients took each vision training once a week for eight weeks and were investigated for the symptoms changes of binocular vision. Results: According to the results, MISTERY CIRCLE vision training methods improved the binocular vision function and sensation symptoms. For Worth 4 Dot test, Titmus test and red lenses showed fusion rate changes. Conclusions: The study proved that MISTERY CIRCLE vision training system for patients with binocular vision was effective for the improvement of the binocular vision symptoms of these patients.

Repeatability of New Phoria Test Using Color Chart and Color Filter (색 시표와 색 필터를 이용한 새로운 사위검사의 신뢰도)

  • Lee, Sun Haeng;Park, Sun-Young;Kim, Sang-Yoeb;Lee, Dong-Yeol;Kim, Kun-Kyu;Son, Jeong-Sik;Lee, Jae Yoon;Cho, Hyun Gug
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.15 no.3
    • /
    • pp.269-274
    • /
    • 2010
  • Purpose: The repeatability of a new Red-Blue phoria chart test (Red-Blue phoria chart; RBP) was appreciated. Methods: Distance (5 m) and near (40 cm) heterophoria was measured in 38 visually normal subjects. Phoria tests using RBP, Howell phoria card (HP), and MIM card (MIM) were done and the repeatability of each phoria test was compared with one another. Results: The mean of horizontal deviations was that RBP was $-0.602{\pm}0.727{\Delta}$, HP was $-0.865{\pm}1.051{\Delta}$, and MIM was $-1.501{\pm}1.346{\Delta}$, at distance, and that RBP was $-2.566{\pm}2.352{\Delta}$, HP was $-2.804{\pm}2.411{\Delta}$, MIM was $-3.838{\pm}2.603{\Delta}$, at near. The repeatability was RBP>MIM>HP in distance tests and MIM>RBP>HP in near tests. Conclusions:RBP test is identified as a reliable phoria test having high repeatability.

Properties of Sunglass Lenses by Non-Destructive Test for the Sunglass Standards (비파괴식 검사를 통한 선글라스의 품질에 관한 연구)

  • Lim, Yong-Moo;Shim, Moon-Sik;Sim, Hyun-Seog;Kim, Sang-Moon
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.6 no.1
    • /
    • pp.125-131
    • /
    • 2001
  • In this study, we compared the properties of 23 high and 55 low price sunglass lenses with the standards in the ordinary optical properties, materials, coloration, UV, IR and luminous transmittance, color acceptance for traffic signal, chromaticity and contrast sensitivity. The ordinary optical properties of the lenses met comparatively the requirements of the KS standard. The HIGH-type and LOW-type lenses were primarily made by glass and acrylate, respectively. In the coloration, HIGH-type was in group around neutral color but LOW-type was distributed widely on the line between 570 nm and 485 nm. There are fails in 7% of HIGH-type and 18% of LOW-type in the stimulus purity of the luminous transmittance. Wavelength of the UV/VIS cut-off was over 350 nm for HIGH-type but 6% of LOW-type was under 350 nm. In the erythemal UV, all HIGH-type met the needs of standards but 5 LOW-type failed with DIN standard In the near UV, KS standard worked in stringency, and HIGH-type showed more failure than LOW-type. The characteristics of the IR transmittance of HIGH-type was better than that of LOW-type. In the color acceptance of traffic signal, all HIGH-type met the needs of ANSI standards but 21.8% of LOW-type failed with the standard. In the contrast sensitivity tested with various coloured sunglasses, the value increased with increasing of Land decreasing of test distance. In view of the results so far, HIGH-type met with excellent properties as compared with LOW-type.

  • PDF

Comparison of three different methods of measuring horizontal phoria and vertical phoria (검사방법에 따른 수평·수직사위량의 비교)

  • Kim, Hye-Dong;Kim, Dae-Nyoun;Park, Eun-Kyeu
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.8 no.2
    • /
    • pp.13-18
    • /
    • 2003
  • We did the comparison research about three different methods of measuring horizontal phoria and vertical phoria which are Von Graefe test, Maddox Rod test and polarizing lens test. The inspection was don with the subjective method of refraction about normal 63 subjects aged from 20 to 28 years old. The analysis of date resulted in as follows : 1. Using Von Graefe Horizontal phoria Measurement, they were measured 5% for orthpharia, 51% for exophoria and 44% for esophoria. 2. Using Von Graefe vertical phoria Measurement, they were measured 68% for orthphoria, 20% for left hypophoria against the right and 12% for left hyperphoria against the right. 3. Using Maddox Rod Horizontal phoria Measurement, they were measured 7% for orthphoria, 49% for exophoria and 44% for esophoria. 4. Using Maddox Rod vertical phoria Measurement, they were measured 70% for orthphoria, 19% for left hypophoria against the right and 11% for left hyperphoria against the right. 5. Using Polarizing Horizontal phoria Measurement, they were measured 10% for orthphoria, 49% for exophoria and 41% for esophoria. 6. Using Polarizing vertical phoria Measurement, they were measured 92% for orthpharia, 5% for left hypophoria against the right and 3% for left hyperphoria against the right.

  • PDF

Comparison of Binocular Function in Normal Subjects and Convergence Insufficiency (정상안과 폭주부족안의 양안시기능 검사값 비교)

  • Shim, Hyun-Seog;Shim, Moon-Sik;Kim, Sang-Hyun
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.15 no.3
    • /
    • pp.287-291
    • /
    • 2010
  • Purpose: The aim of this study was to compare binocular functions such as near point of convergence (NPC), AC/A ratios, heterophoria, accommodation, accommodation lag, positive relative accommodation (PRA), negative relative accommodation (NRA), positive relative convergence (PRC), negative relative convergence (NRC) in normal subjects and convergence insufficiency. Methods: 86 subject (male n=45, female n=41, mean $age{\pm}SD=23.27{\pm}2.85$ years) without amblyopia, strabismus, and ocular pathology were studied. Forty three patients each group were classified as normal subjects and convergence insufficiency group based on AC/A ratio and far and near phoria. Binocular function of the two groups was measured using phoropter. r. Results: The values between normal subjects and convergence insufficiency were 5.71 cm and 7.07 cm for NPC, 5.28 and 2.81 for Heterophria AC/A, 0.92 exo/3.36 exo and 2.17 exo/10.84 exo for far and near phoria, 15.49/23.30/13.30 and 13.50/20.02/9.09 for PRC, respectively. However, there were no significant differences between normal subjects and convergence insufficiency for accommodative amplitude, accommodative lag, PRA, NRA, BI vergence test, BO vergence test, NRC. Conclusions: Both groups were a significant difference for cover test, NPC, Heterophria AC/A, far and near phoria, break point of PRC, and recovery point of PRC.