• Title/Summary/Keyword: ophthalmic lens

Search Result 521, Processing Time 0.032 seconds

Comparison of Accommodative Amplitude Based on Occupation of Initial Presbyopia (직업별 초기 노안자의 조절력 비교)

  • Kim, Hyun-Mok;Son, Jeong-Sik;Kim, In-Su;Cho, Hyun Gug
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.13 no.4
    • /
    • pp.135-139
    • /
    • 2008
  • Purpose: This study was designed to compare the accommodative amplitude whose 40s initial presbyopia patients divided into five occupation (driver, official worker, housewife, field worker, teacher). Methods: Both "push-up"and "inus lens to blur technique" methods were used to examine the average of accommodative amplitude. Results: All the average of accommodative amplitude (OD, OS, and OU) were the lowest in official worker group (3.27${\pm}$0.21D, 3.31${\pm}$0.22D, 3.54${\pm}$0.28D) and the highest in housewife group (4.07${\pm}$0.35D, 4.11${\pm}$0.35D, 4.37${\pm}$0.39D). Conclusions: Because occupational specifications including a fixative habit are able to change the binocular accommodation, it is important to understand thoroughly the patient's occupation when opticians make near vision prescription for initial presbyopia.

  • PDF

Design and Fabrication for the Development of Auto Pattern Maker (자동취형기 개발을 위한 설계 및 제작)

  • Lee, Young-Il;Kim, Jung-Hee;Park, Jee-Hyun
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.18 no.3
    • /
    • pp.231-239
    • /
    • 2013
  • Purpose: To design and fabricate the auto pattern maker for the development. Methods: we got the necessary data, needed in design, by using CAD. Based on the these data, we fabricated the trial product for the development of the auto pattern maker. Results: The auto pattern maker were composed with combinations of many elements; pattern making assembly, control panel, frame attachment and prober unit. The pattern making assembly was comprised of the cutter, the pattern holder, pattern remover and silence cover which could minimize the sound during the cutting process. The control panel was designed to be connected and operated with the main printed circuit board. The prober could get the eye shape data by scanning of 1.8 degrees around the groove of the frame through the encoding data according to the address. After starting, scanning was carried out in two passes, i.e. one right-handed and one left-handed. Communication connector could send the eye shape data from auto pattern maker to outer system with the RS232C transmission system. By using the one-way analysis of variance, we got the error rate of cut pattern size for ${\Phi}22mm$, ${\Phi}55mm$ and ${\Phi}62mm$. Because F-value was 0.510 and p-value was 0.601, no statistically significant differences were found. Also, the mean cutting error of the auto pattern maker was 0.0274 mm. Conclusions: we could succeed in making the trial product by applying it to the development of the auto pattern maker. The role of this auto pattern maker is to find a exact required size of lens to fit the frame by measuring the frame. The acquired data are transferred to outer system for grinding and finishing with patternless process. Also, the trial product can produce pattern to fit the frame. Therefore, it was confidently expected that the optometrists could handily produce pattern to fit the frame with this trial product and dispense the ophthalmic lens because of its efficiency and convenience compared to the past.

Characterization and Application for Hydrogel Lens Material of Acrylate Monomers Containing Hydroxyl Group (하이드록시기를 포함한 아크릴레이트계 모노머들의 하이드로젤 친수성 렌즈 소재로의 응용 및 특성)

  • Lee, Min-Jae;Kim, Tae-Hun;Sung, A-Young
    • Journal of the Korean Chemical Society
    • /
    • v.60 no.3
    • /
    • pp.181-186
    • /
    • 2016
  • The hydrophilic ophthalmic lens with addition of 2-hydroxyethyl acrylate (HEA), 2-hydroxyethyl methacrylate (HEMA), hydroxypropyl methacrylate (HPMA) and Ag nanoparticles were manufactured. And also, the cross-linker ethylene glycol dimethacrylate (EGDMA) and the initiator azobisisobutyronitrile (AIBN) were used for polymerization. The polymerization of the hydrogel lens material was conducted through thermal polymerization in 100 ℃ for 1h. The optical and physical characteristics of hydrogel lens were evaluated by measuring water content, refractive index and optical transmittance. The water content of sample containing HEA, HEMA and HPMA was in the average of 82.12%, 37.06% and 21.57%, respectively. And also, refractive index of the sample containing HEA, HEMA and HPMA was in the average of 1.3540, 1.4330 and 1.4649, respectively. In case of the optical properties of the sample, the results showed that the near-UV transmittance was 82.67%, 80.32% and 79.83%, and the visible transmittance was 89.72%, 88.24% and 86.89%, respectively. And also, optical transmittance of the sample containing Ag nanoparticles showed that the near-UV transmittance of 10.59% and visible transmittance of 43.74% were obtained. From the results, the molecular length influenced on the water content and refractive index of the polymerized material.

Trends and Refractive Status of Cataract Surgery - An Optometry Clinic-Based Survey in Chungbuk (백내장 수술 경향과 굴절상태 - 충북 지역의 안경원 중심으로 조사)

  • Kim, Hyeong-Su;Son, Jeong-Sik;Yu, Dong-Sik
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.18 no.2
    • /
    • pp.143-148
    • /
    • 2013
  • Purpose: The aim of this study was to investigate the distribution of age and gender, types of intraocular lens (IOL), and refractive errors in subjects who had cataract surgery. Methods: 2,217 subjects who had cataract surgery were surveyed at an optometry clinic in Chungbuk from 2010 to 2012. Information about IOL was obtained from case history, reflective and retroillumination images IOL by auto refracto-keratometer. Refractive errors were determined by objective and subjective refraction. Results: The mean age of the subjects was $71.74{\pm}10.62$ years. The number of cataract surgeries increased from 524 persons in 2010 to 888 persons in 2012. Of the subjects surveyed, 52 persons (2.3%) were under the 40 years of age, 144 persons (6.5%) were in 50s, 404 persons (18.2%) were in 60s, 1,132 persons (51.1%) were in 70s, 485 persons (21.9%) were in above 80s. Cataract surgery was significantly prevalent in more female (1,338 persons, 60.4%) than in male (879 persons, 39.6%). Types of IOL were 2,141 persons (96.6%) for monofocal lens, special IOLs such as multifocal, accommodative and toric lens were 76 persons (3.4%). The distribution of refractive errors after cataract operation were 1,588 eyes (38.5%) for simple myopic astigmatism, 327 eyes (7.9%) for simple hyperopic astigmatism, 601 eyes (14.6%) for mixed astigmatism, 1,240 eyes (30.0%) for myopia, 136 eyes (3.3%) for hyperopia, and 234 eyes (5.7%) for emmetropia. The uncorrected and best corrected visual acuity of the subjects were $0.55{\pm}0.25$ and $0.80{\pm}0.23$, respectively. Conclusions: The prevalence of cataract surgery increased with age until 70s years of age, it was more prevalent in men than women over 60s, and frequency of special types of IOL were low. Most cataract surgeries left residual refractive errors. Therefore even after cataract surgery it may need spectacles for better vision at either distance or near.

Study of Masking Effect of Soft Contact Lenses on Cornea after Refractive Surgery (각막굴절교정 수술 안에 대한 소프트콘택트렌즈 착용 시 Masking 효과)

  • Moon, Ye-Rim;Park, Hyung-Min;Chu, Byoung-Sun
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.21 no.2
    • /
    • pp.91-98
    • /
    • 2016
  • Purpose: This study investigated the masking effect of the hydrogel lens and silicone hydrogel lens on the cornea with refractive surgery and without surgery. Methods: 24 university students (means age: $23.48{\pm}2.89years$) without refractive surgery (12, control group) and with refractive surgery (LASIK: 8, LASEK: 4, experimental group) participated in the study. Mean refractive errors of right eyes were -2.73 D for control group and -0.24 D for experimental group. The differences in the refractive power and corneal topography map between pre- and post-wearing the -3.00 D lenses were compared, and 2 kinds of hydrogel contact lenses (0.89 Mpa, 0.49 Mpa) and 2 kinds of silicone hydrogel lenses (1.5 Mpa, 0.8 Mpa) were used for -3.00 D lenses. NVision-K5001 (Shin nippon, Japan) was used to measure the refractive power and Keratograph 5M (Oculus, Germany) to measure the corneal topography map change. Results: Variations in the refractive power increased to the plus direction in the experimental group after wearing soft contact lenses. The corneal topography map showed significant changes on the both groups after wearing soft contact lenses (p<0.05). However there were no significant differences in the refractive power and corneal topography map variations by lens materials. Conclusions: Wearing soft contact lenses showed corneal topography map changes. Especially wearing soft contact lenses on the flat cornea after corneal refractive surgery showed greater corneal power changes. Therefore, it should pay attention to refractive change in case of prescribing soft contact lenses to patients with corneal refractive surgery.

Microbe Pollution Condition on Soft Contact Lenses (소프트 콘택트렌즈에서의 미생물 오염양상)

  • Han, Sun-Hee;Park, Sung-Min;Yu, Tae-Shick
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.10 no.4
    • /
    • pp.313-321
    • /
    • 2005
  • To know the pollution level concerning the microbes contamination condition in soft contact lenses, 2 experiments were operated with different methods. Firs experiment, we observed lenses surfaces through a scanning electronic microscope after pollution sort contact lenses with the suspensions of Staphylococcus aureus, Pseudomonas aeruginosa and Entrobacter aerogenes which can be major bacteria causing keratitis as wearing on soft contact lenses. As 1 hour after pollution with the soft contact lenses, we observed that many bacteria adhered to the lenses, and the pollution condition got worse with passing time increase(2, 4, 6, 12, and 24 hours, respectively). At 12 hours lapse of polluting soft contact lenses with P. aeruginosa, some bacteria adhered to the lenses. And as 24 hours lapsed after pollution soft lenses with E. aerogenes, bacteria adhered to them, and atypical substance was observed some of the surface of lenses. Second experiment, we observed the microbe pollution condition in soft contact lenses by let 21 people in twenties(men & women), who doesn't eye disorders, wear soft contact lenses during 4 hours. As the result, many kinds of bacterium and fungus were observed, and especially, the bacteria could be identified with their colors and the shapes of colony, so we found that single type, two types, and three types of bacteria adhered to their lenses.

  • PDF

A study on Monovision of Fitting soft contact lenses for College students (대학생에게 유도된 소프트 콘택트렌즈 모노비전에 관한 연구)

  • Kim, Jai-Min
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.9 no.1
    • /
    • pp.181-188
    • /
    • 2004
  • Monovision is defined as correcting one eye for distance vision and the other eye for near vision. Single-vision contact lenses are used for each eye. The patient selectively suppresses one eye while using the other eye. This study was performed to measure binocular function and patient satisfaction with monovision induced by adding +3.00D to spectacle prescription for distance vision in nonpresbyopic students. This study comprised 144 nonpresbyopic students with monovision induced by adding +3.00D to spectacle prescription. Monovision was induced by undercorrecting the nondominant eye by adding 3.00 diopters for near vision and correcting the dominant eye with emmetropia for distance vision. For research of the binocular function on Monovision. This study was tested the obstacle course, water pouring test, catching and throwing, bead classification including the stereopsis test. These tests were comparative to the normal binocular state. As a results, the stereopsis have a significant reductions in Monovision. There was no significantly difference between monovision group and control group in monovision exercise (obstacle course, water pouring test, catching and throwing, and bead sorting) at near and distance. This study indicates that monovision is an effective and reasonable therapeutic modality for correcting presbyopia. By the application of above methods, this study could be used the student for the practical practice and understand on the Monovison.

  • PDF

Reliability of Measurements of Back Vertex Power for Soft Contact Lenses Using an Auto-Lensmeter (자동렌즈미터를 이용한 소프트 콘택트렌즈의 굴절력 측정 방법에 관한 신뢰도)

  • Kim, Kun-Kyu;Lee, Wook-Jin;Lee, Sun-Haeng;Kwak, Ho-Won;Yu, Dong-Sik
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.15 no.1
    • /
    • pp.39-46
    • /
    • 2010
  • Purpose: To assess the reliability for measuring the back vertex power of soft contact lenses by dry blotting and wet cell method using an auto-lensmeter. Methods: The soft contact lenses used for measurement were 5 types that were distributed in Korea, and 4 back vertex powers (-1.50D, -3.00D, -6.00D, -9.00D) were used. and repeatability and reproducibility were evaluated by measuring them with an auto-lensmeter by two examiners. Results: Measured powers by dry blotting method were ranged in mean differences from 0.03D to 0.18D for overall lenses, 0.10D to 0.18D for silicone hydrogel lenses, 0.03D to 0.08D for hydrogel lenses. The mean differences between two examiners were less than 0.10D, and the inter-examiner reproducibility was good for dry blotting method. The mean difference between powers determined by wet cell method were 0.09D to 0.69D, the mean differences between two examiners were 0.02D to 0.59D. The reliability of measurements and inter-examiner reproducibility were less than dry blotting method. Conclusions: The reliability of measurements for all materials was better in dry blotting than wet cell method, the re liability of measurements for silicone hydrogel lenses was low in both methods. In clinical practical which requires quick checking of back vertex power using an auto-lensmeter. dry blotting method is thought to be more efficient than wet cell one.

A Clinical Study of Ocular Dimention and Visual Acuity Before and After Cataract Surgery Over Ninety Years Old (90세 이상 초고령 환자들의 백내장 수술전.후 안수치와 시력에 관한 임상연구)

  • Lee, Jung-Mi;Kim, In-Suk;Shin, Jin-Ah
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.15 no.3
    • /
    • pp.275-280
    • /
    • 2010
  • Propose: Due to the rapid growth of medical technologies and the increasing population of older people, we investigated clinical status of ocular dimensions and visual acuity for pre and post cataract surgeries of people over age 90. Methods: From March 2007 to February 2009, we investigated eighty-two eyes of forty-eight patients who had undergone cataract surgeries at an ophthalmic clinic (Ansung, Kyungi-do), investigated maximum corrected vision, axial length, anterior chamber depth and accompanied ocular diseases before and after the surgeries based on the collected data. Results: As patients aged, axial length unchanged but anterior chamber depth decreased over all due to the increase of intraocular lens thickness, and men tended to have a higher degree than women. Seventy-one (86.6%) of eighty-two eyes showed improved corrected vision than before surgeries and forty-three (52.4%) eyes could see more than visual acuity of 0.5. Conclusions: Patients with the systemic disease and accompanied ocular disease showed low vision less than 0.5 after cataract surgery compared to same healthy age peoples. But the others improved correction visual acuity more than 0.5, so the cataract surgery was surely necessary for people over 90 years old and also the presence of ocular disease could have a great influence on correction visual acuity.

Analysis of Addition Power for New Wearer of Progressive Addition Lenses (누진렌즈 안경 처음 착용자의 가입도 분석)

  • Joo, Seok-Hee;Shim, Hyun-Suk;Shim, Jun-Beom
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.18 no.3
    • /
    • pp.247-251
    • /
    • 2013
  • Purpose: To analyse the addition power of new wearer of progressive addition lenses. Methods: Data of 636 subjects who have been prescribed progressive addition lenses as the first time were used for analyse. The range of age for was between 41~78 years old and they visited the optical practice in Gwangju metropolitan city from 2001 to 2013Date of refractive state, gender and age were analysed. Results: The difference of addition by gender was 1.71 D in male and 1.67 D in women. The difference of addition by refractive error was 1.67 D in emmetropic patients and 1.74 D in myopic patients, 1.90 D in hyperopic patients. The difference of addition by age was1.26 D in 41~44 years old sge group, 1.48 D in 45~49 years old age group,1.72 D in 50~54 years old age group 1.84 D in 55~59 years old age group, 2.10 D in 60~64 years old age group and 2.43 D in over 65 years old age group. The difference of addition by diopter in myopic patients was 1.58 D in low myopic patients and 1.48 D in middle myopic patients, 1.67 D in high myopic patients. The difference of addition by axis of astigmatism was 1.80 D in with-the-rule astigmatism, 1.64 D in against-the-rule astigmatism and 1.65 D in oblique astigmatism. Conclusions: The Addition power of progressive lenses were different according to the types of refractive error, astigmatism axis and age.