• Title/Summary/Keyword: operator.

Search Result 5,805, Processing Time 0.039 seconds

Evaluation of Albumin Creatinine Ratio as an Early Urinary Biomarker for Chronic Kidney Disease in Dogs

  • Hyun-Min Kang;Heyong-Seok Kim;Min-Hee Kang;Jong-Won Kim;Dong-Jae Kang;Woong-Bin Ro;Doo-Won Song;Ga-Won Lee;Hee-Myung Park;Hwi-Yool Kim
    • Journal of Veterinary Clinics
    • /
    • v.40 no.6
    • /
    • pp.399-407
    • /
    • 2023
  • Chronic kidney disease (CKD) occurs in more than 15% of the dogs over 10 years of age and causes irreversible renal function deterioration. Therefore, it is important to diagnose CKD early and treat the disease properly. The purpose of this study aimed to to evaluate the clinical utility of urine albumin/creatinine ratio (ACR) using POC (point-of-care) device as an early detection urinary biomarker in CKD dogs and to confirm the correlation between ACR and other known CKD biomarkers. Urine and serum samples were obtained from 50 healthy dogs and 50 dogs with CKD. Serum blood urea nitrogen (BUN), creatinine, and symmetric dimethylarginine (SDMA) concentrations, and urine protein creatinine ratio (UPC) were measured. Urine specific gravity (USG) was evaluated using refractometer, and ACR was measured using an i-SENS A1Care analyzer. The ACR values of dogs with CKD were significantly different from those of healthy dogs (p < 0.001), as with other renal biomarkers. ACR showed significant differences between healthy dogs and dogs with CKD at every IRIS stage (p < 0.005), whereas no significant differences were observed between dogs with CKD IRIS stage I and healthy dogs with UPC. There are significant positive correlation between ACR and BUN (r = 0.611, p < 0.001), creatinine (r = 0.788, p < 0.001), SDMA (r = 0.747, p < 0.001), and UPC (r = 0.784, p < 0.001), and significant negative correlation between ACR and USG (r = -0.700, p < 0.001). In receiver operator characteristic curve analysis, the area under the curve (AUC) was 0.982 (95% CI 0.963-1.000, p < 0.001), with an optimal cut-off value of 64.20 mg/g (94% sensitivity and 94% specificity). Thus, ACR is a useful urinary biomarker for the early diagnosis of proteinuria in CKD and combined use of ACR and other renal biomarkers may be helpful for early diagnosis and prevention of CKD in dogs.

Development of new artificial neural network optimizer to improve water quality index prediction performance (수질 지수 예측성능 향상을 위한 새로운 인공신경망 옵티마이저의 개발)

  • Ryu, Yong Min;Kim, Young Nam;Lee, Dae Won;Lee, Eui Hoon
    • Journal of Korea Water Resources Association
    • /
    • v.57 no.2
    • /
    • pp.73-85
    • /
    • 2024
  • Predicting water quality of rivers and reservoirs is necessary for the management of water resources. Artificial Neural Networks (ANNs) have been used in many studies to predict water quality with high accuracy. Previous studies have used Gradient Descent (GD)-based optimizers as an optimizer, an operator of ANN that searches parameters. However, GD-based optimizers have the disadvantages of the possibility of local optimal convergence and absence of a solution storage and comparison structure. This study developed improved optimizers to overcome the disadvantages of GD-based optimizers. Proposed optimizers are optimizers that combine adaptive moments (Adam) and Nesterov-accelerated adaptive moments (Nadam), which have low learning errors among GD-based optimizers, with Harmony Search (HS) or Novel Self-adaptive Harmony Search (NSHS). To evaluate the performance of Long Short-Term Memory (LSTM) using improved optimizers, the water quality data from the Dasan water quality monitoring station were used for training and prediction. Comparing the learning results, Mean Squared Error (MSE) of LSTM using Nadam combined with NSHS (NadamNSHS) was the lowest at 0.002921. In addition, the prediction rankings according to MSE and R2 for the four water quality indices for each optimizer were compared. Comparing the average of ranking for each optimizer, it was confirmed that LSTM using NadamNSHS was the highest at 2.25.

Angioembolization performed by trauma surgeons for trauma patients: is it feasible in Korea? A retrospective study

  • Soonseong Kwon;Kyounghwan Kim;Soon Tak Jeong;Joongsuck Kim;Kwanghee Yeo;Ohsang Kwon;Sung Jin Park;Jihun Gwak;Wu Seong Kang
    • Journal of Trauma and Injury
    • /
    • v.37 no.1
    • /
    • pp.28-36
    • /
    • 2024
  • Purpose: Recent advancements in interventional radiology have made angioembolization an invaluable modality in trauma care. Angioembolization is typically performed by interventional radiologists. In this study, we aimed to investigate the safety and efficacy of emergency angioembolization performed by trauma surgeons. Methods: We identified trauma patients who underwent emergency angiography due to significant trauma-related hemorrhage between January 2020 and June 2023 at Jeju Regional Trauma Center. Until May 2022, two dedicated interventional radiologists performed emergency angiography at our center. However, since June 2022, a trauma surgeon with a background and experience in vascular surgery has performed emergency angiography for trauma-related bleeding. The indications for trauma surgeon-performed angiography included significant hemorrhage from liver injury, pelvic injury, splenic injury, or kidney injury. We assessed the angiography results according to the operator of the initial angiographic procedure. The term "failure of the first angioembolization" was defined as rebleeding from any cause, encompassing patients who underwent either re-embolization due to rebleeding or surgery due to rebleeding. Results: No significant differences were found between the interventional radiologists and the trauma surgeon in terms of re-embolization due to rebleeding, surgery due to rebleeding, or the overall failure rate of the first angioembolization. Mortality and morbidity rates were also similar between the two groups. In a multivariable logistic regression analysis evaluating failure after the first angioembolization, pelvic embolization emerged as the sole significant risk factor (adjusted odds ratio, 3.29; 95% confidence interval, 1.05-10.33; P=0.041). Trauma surgeon-performed angioembolization was not deemed a significant risk factor in the multivariable logistic regression model. Conclusions: Trauma surgeons, when equipped with the necessary endovascular skills and experience, can safely perform angioembolization. To further improve quality control, an enhanced training curriculum for trauma surgeons is warranted.

Implant assisted removable partial denture using bilateral single implant-supported surveyed crown: a case report (양측성 단일 임플란트 지지 서베이드 크라운을 이용한 하악 임플 란트 보조 국소의치 수복 증례)

  • Seojune Choi;Hong Seok Moon;Jaeyoung Kim
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.62 no.2
    • /
    • pp.146-156
    • /
    • 2024
  • Implant assisted removable partial denture (IARPD) has been practiced in various forms for a long time, and among them, implant surveyed crown RPD is gaining predictability as well as being considered as a treatment option for patients with anatomical and financial disadvantages. The position of implant could be divided as posterior placement or anterior placement according to the purpose of the treatment and should be planned in consider to the alveolar ridge of patient, anticipated prognosis of remaining teeth, and opposing dentition. This case report describes a treatment for mandibular Kennedy class I partial edentulous patient with two implant-supported surveyed crown and implant assisted removable partial denture. Given the difficulty of posterior placement in this patient and the prognosis of the residual teeth, the plan was to place two implants in close proximity to the residual teeth, which were placed in the planned position, angle, and depth using guided surgery. The process of fabricating the fixed prosthesis was carried out in parallel with the maxillary edentulous tooth arrangement process to increase predictability, and when fabricating the localized tooth, the implant was designed in a form that allows the patient to perform functional movements by preventing excessive loading as the last supporting tooth, and was fabricated through a secondary impression process. Each treatment procedure was proceeded as planned, with aesthetically and functionally satisfactory results for both patient and operator.

Variability of Transrectal Shear Wave Elastography in a Phantom Model (팬텀연구에서 경직장 전단파탄성초음파의 가변성)

  • Jihyun Lee;Seong Kuk Yoon;Jin Han Cho;Hee Jin Kwon;Dong Won Kim;Jun Woo Lee
    • Journal of the Korean Society of Radiology
    • /
    • v.84 no.5
    • /
    • pp.1110-1122
    • /
    • 2023
  • Purpose This study aimed to assess the variability of transrectal shear wave elastography (SWE) using a designed phantom. Materials and Methods In a phantom, the SWE values were examined by two radiologists using agarose and emulsion silicone of different sizes (1, 2, and 3 cm) and shapes (round, cubic) at three depths (1, 2, and 3 cm), two region of interest (ROI) and locations (central, peripheral) using two ultrasound machines (A, B from different vendors). Variability was evaluated using the coefficient of variation (CV). Results The CVs decreased with increasing phantom size. Significant changes in SWE values included; agarose phantom at 3 cm depth (p < 0.001; machine A), 1 cm depth (p = 0.01; machine B), emulsion silicone at 2 cm depth (p = 0.047, p = 0.020; both machines). The CVs increased with increasing depth. Significant changes in SWE values included; 1 cm agarose (p = 0.037, p = 0.021; both machines) and 2 cm agarose phantom (p = 0.047; machine A). Significant differences in SWE values were observed between the shapes for emulsion silicone phantom (p = 0.032; machines A) and between ROI locations on machine B (p ≤ 0.001). The SWE values differed significantly between the two machines (p < 0.05). The intra-/inter-operator agreements were excellent (intraclass correlation coefficient > 0.9). Conclusion The phantom size, depth, and different machines affected the variability of transrectal SWE.

Evaluation for Application of IOM Sampler for Agricultural Farmer's Inhalation Exposure to Kresoxim-methyl and Fenthion (농작업자의 Kresoxim-methyl과 fenthion에 대한 호흡노출량 측정을 위한 IOM 채집기의 효율성 평가)

  • Lee, Jiho;Kim, Eunhye;Lee, Jonghwa;Shin, Yongho;Maasfeld, Wolfgang;Choi, Hoon;Moon, Joon-Kwan;Lee, Hyeri;Kim, Jeong-Han
    • The Korean Journal of Pesticide Science
    • /
    • v.19 no.3
    • /
    • pp.230-240
    • /
    • 2015
  • An IOM sampler equipped with glass fiber filter has been recently utilized instead of solid adsorbent, which was used to measure the inhalation exposure of agricultural operator to pesticides. The aim of this study is to validate the efficacy of an IOM sampler by measuring the trapping efficiency and breakthrough using kresoxim-methyl water-dispersible granule and fenthion emulsifiable concentrate. On LC-MS/ MS, minimum detection level was 12.5 pg and method limit of detection was 5.0 ng/mL. Good linearity ($R^2$ > 0.999) for matrix matched standards was obtained. Recoveries of pesticides from glass fiber filter were 102-109% (kresoxim-methyl) and 97-104% (fenthion) while those from XAD-2 resin were 94-98% (kresoxim methyl) and 93-100% (fenthion). Trapping efficiency test was performed with personal air pumps and IOM sampler (glass fiber filter) connected with solid adsorbent (XAD-2 resin) with two types of formulation (solid and liquid) which were diluted by standard rate and sprayed to IOM sampler. Those pesticides were trapped only in glass fiber filter without any breakthrough to solid adsorbent. After spiking of pesticides to glass fiber filter, breakthrough test was carried out with IOM sampler (glass fiber filter) which was connected with solid adsorbent. As a results, 87-101% of kresoxim-methyl and 96-105% of fenthion remained in spiked glass fiber filter, however, no pesticides were detected in second glass fiber filter and solid adsorbent. In conclusion, IOM sampler which equipped with glass fiber filter can be applied widely for pesticide inhalation exposure study since it has good trapping efficiency and adsorption capacity, regardless of the solid or liquid formulation.

A Development of Traffic Queue Length Measuring Algorithm Using ILD(Inductive Loop Detector) Based on COSMOS (실시간 신호제어시스템의 대기길이 추정 알고리즘 개발)

  • seong ki-ju;Lee choul-ki;Jeong Jun-ha;Lee young-in;Park dae-hyun
    • The Journal of The Korea Institute of Intelligent Transport Systems
    • /
    • v.3 no.1 s.4
    • /
    • pp.85-96
    • /
    • 2004
  • The study begin with a basic concept, if the occupancy length of vehicle detector is directly proportional to the delay of vehicle. That is, it analogize vehicle's delay of a occupancy time. The results of a study was far superior in the estimation of a queue length. It is a very good points the operator is not necessary to optimize s1, s2, Thdoc. Thdoc(critical congestion degree) replaced 0.7 with 0.2 - 0.3. But, if vehicles have been experience in delay was not occupy vehicle detector, the study is in existence some problems. In conclusion, it is necessary that stretch queue detector or install paired queue detector. Also I want to be made steady progress a following study relation to this study, because it is required traffic signal control on congestion.

  • PDF

A Study on the Application of Block Chain Technology on EVMS (EVMS 업무의 블록체인 기술 적용 방안 연구)

  • Kim, Il-Han;Kwon, Sun-Dong
    • Management & Information Systems Review
    • /
    • v.39 no.2
    • /
    • pp.39-60
    • /
    • 2020
  • Block chain technology is one of the core elements for realizing the 4th industrial revolution, and many efforts have been made by government and companies to provide services based on block chain technology. In this study we analyzed the benefits of block chain technology for EVMS and designed EVMS block chain platform with increased data security and work efficiency for project management data, which are important assets in monitoring progress, foreseeing future events, and managing post-completion. We did the case studies on the benefits of block chain technology and then conducted the survey study on security, reliability, and efficiency of block chain technology, targeting 18 block chain experts and project developers. And then, we interviewed EVMS system operator on the compatibility between block chain technology and EVM Systems. The result of the case studies showed that block chain technology can be applied to financial, logistic, medical, and public services to simplify the insurance claim process and to improve reliability by distributing transaction data storage and applying security·encryption features. Also, our research on the characteristics and necessity of block chain technology in EVMS revealed the improvability of security, reliability, and efficiency of management and distribution of EVMS data. Finally, we designed a network model, a block structure, and a consensus algorithm model and combined them to construct a conceptual block chain model for EVM system. This study has the following contribution. First, we reviewed that the block chain technology is suitable for application in the defense sector and proposed a conceptual model. Second, the effect that can be obtained by applying block chain technology to EVMS was derived, and the possibility of improving the existing business process was derived.

The treatment of an edentulous patient with DENTCA$^{TM}$ CAD/CAM Denture (CAD/CAM Denture를 이용한 완전 무치악 환자 수복 증례)

  • Park, Joon-Ho;Cho, In-Ho;Shin, Soo-Yeon;Choi, Yu-Sung
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.53 no.1
    • /
    • pp.19-25
    • /
    • 2015
  • Nowadays, CAD/CAM is broadly used in dentistry for inlays, crowns, implant abutments and its spectrum is expanding to complete dentures. Utilizing CAD/CAM to fabricate complete dentures is expected to decrease chair time and the number of visits, thus decreasing total fabrication time, expenses and errors caused during fabrication processes. One of the systems using CAD/CAM, DENTCA$^{TM}$ CAD/CAM denture (DENTCA Inc. Los Angeles, USA) scans edentulous impressions, designs dentures digitally, fabricates try-in dentures by 3D printing and converts them into final dentures. Patients can wear final dentures after only 2 - 3 visits with satisfying adaptation. This case report introduces a 71-year-old male patient who visited to consult remaking of existing old dentures. Residual teeth with bad prognosis and root remnants were extracted and the patient used reformed existing mandibular denture for 2 months. And then DENTCA system started. One-step border molding was done using conventional tray of adequate size provided by DENTCA system and wash impression was taken. Gothic arch tracing was completed based on the vertical dimension of existing dentures. Both maxillary and mandibular trays were placed to the resultant centric relation and bite registration was taken. Then DENTCA scanned the bite registration, arranged the teeth, completed the festooning and fabricated the try-in dentures by 3D printing. The try-in dentures were positioned, occlusal plane and occlusal relations were evaluated. The try-in dentures were converted to final dentures. To create bilateral balanced occlusion, occlusal adjustment was done after clinical remounting using facebow transfer. The result was satisfactory and it was confirmed by patient and operator.

Assessment and Calibration of Ultrasonic Velocity Measurement for Estimating the Weathering Index of Stone Cultural Heritage (석조문화재의 풍화지수 산정을 위한 초음파속도의 평가 및 보정)

  • Lee, Young-Jun;Keehm, Young-Seuk;Lee, Min-Hui;Han, June-Hee;Kim, Min-Su
    • Journal of the Korean earth science society
    • /
    • v.33 no.2
    • /
    • pp.126-138
    • /
    • 2012
  • Ultrasonic method is widely used for the evaluation of weathering index and of degree of deterioration because it is easily applicable $in$ $situ$. The basic idea of the method is that the ultrasonic velocity decreases as a rock is being weathered. Thus, the difference of ultrasonic velocities between fresh rock and weathered rock indicates the degree of weathering. In this method, the ultrasonic velocity of fresh rock is assumed to be 5,000 m/s. However, this assumption can cause significant errors in estimating weathering index, especially in case that those rocks of the same type have a wide range of ultrasonic velocities such as in Korea. Therefore, we obtained twenty rock specimens and sixty core samples commonly used for stone cultural heritages in Korea, and measured ultrasonic velocities. From the results, we found that the ultrasonic velocities of the same rock type, granite samples range from 3,118 to 5,380 m/s, and that the estimated weathering index can be highly biased if we use the fixed value of 5,000 m/s. We created a database (DB) by combining the measurement data and reported it. We also measured ultrasonic velocities by direct and indirect methods to quantify the calibration coefficient for each sampling site. We found that the calibration coefficients vary widely from site to site (1.31-1.76). Other factors, such as operator bias and temperature did not show any significant effect on errors in ultrasonic velocity measurements. Lastly, we applied our ultrasonic velocity DB and calibration coefficients to a stone cultural heritage, Bonghwang-ri Buddha statue. Our estimation of the weathering index was 0.3, 0.1 smaller than that by conventional method. The degree of deterioration was also different, "moderately weathered", while conventional method gave "highly weathered". Since other independent studies reported that the degree of deterioration of the Buddha statue was "moderately weathered", our estimation seems to be more accurate. Thus our method can help accurately evaluate the weathering index and the conservation planning for a stone cultural heritage.