• 제목/요약/키워드: operational characteristic

검색결과 266건 처리시간 0.037초

개선된 보상특성을 갖는 증폭기용 온도보상회로 (Thermal Compensation Circuit with Improved Compensation Characteristic for Power Amplifier)

  • 정영배
    • 전기전자학회논문지
    • /
    • 제16권3호
    • /
    • pp.177-181
    • /
    • 2012
  • 본 논문에서는 증폭기의 온도에 따른 균일한 출력특성을 구현하기 위한 개선된 보상특성을 갖는 증폭기용 온도보상회로를 제안한다. 제안된 온도보상회로는 직렬로 연결된 2개의 브랜치라인(Branchline) 결합기와 결합기 사이에 위치한 2개의 다이오드로 구성된다. 그리고, 회로의 주변온도에 따라서 저항값이 반비례하는 특서을 갖는 써미스터(Thermistor)와 써미스터를 포함하는 오피엠프(Operational amplifier, OP-Amp.)회로로 다이오드의 동작 특성을 조정함으로써 기존의 온도보상회로에 비하여 보다 효율적인 보상특성을 갖도록 설계하였다.

연산증폭기를 이용한 접지형 인덕터의 구성에 관한 연구 (Study on a grounded inductor simulated by the use of the operational amplifier)

  • 김성수;공남수
    • 전기의세계
    • /
    • 제28권9호
    • /
    • pp.35-40
    • /
    • 1979
  • A grounded inductor is proposed which contains only one resistor and operational amplifier. The circuit uses the inherent frequency dependent characteristic of an amplifier to simulate the inductor. A parallel resonance circuit is constructed with the proposed circuit. It has been proved by the experimental results of the resonant circuit that the proposed circuit is equivalent to the grounded lossy inductor. The lossy inductor is imbedded in a passive bandstop prototype, and the resultant characteristic curve has been verified by the experiment.

  • PDF

녹색 신교통 시스템 바이모달트램의 수송수요 및 운행속도별 운영비용 분포특성 분석 (The Analysis of Distribution Characteristic on the Operation Cost for Respective Transport Volume and Travel Speed of New Transit System Bi-Modal Tram)

  • 배을호;김경만;신철호;김도한;박영곤
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2010년도 춘계학술대회 논문집
    • /
    • pp.2297-2302
    • /
    • 2010
  • The status and effectiveness of Bi-modal Tram is analyzed through the comparison of the transport effectiveness and operation cost between the public transportation systems (bus, light rail transit) considering the vehicle and operation characteristic of new transit system Bi-modal Tram. The standard operation schedule is established in consideration of the vehicle specification and operation characteristic of main public transportation modes, and then the annual average operation cost is estimated depending on the volume, speed, analysis length for respective public transportation mode. Through analyzing the operation cost and distribution characteristic of public transportation modes depending on the transport volume and travel speed, the operational efficiency suitable for the city is derived. It is concluded that the operational efficiency of Bi-modal Tram is superior to that of the bus and light rail transit on the aspect of travel volume and operation speed.

  • PDF

New methodologies to derive discharge limits considering operational flexibility of radioactive effluents from Korean nuclear power plants based on historical discharge data

  • Kang, Ji Su;Cheong, Jae Hak
    • Nuclear Engineering and Technology
    • /
    • 제54권3호
    • /
    • pp.1003-1015
    • /
    • 2022
  • The new methodologies to derive discharge limits considering operational flexibility according to international safety standards were developed to help reduce the environmental releases of radioactive effluents from nuclear power plants (NPPs). To overcome the limitations of the two existing methods to set up discharge limits assuming a specific statistical distribution of the effluent discharge, two modified equations were newly proposed to directly derive a particular discharge limits corresponding to the target 'compliance probability' based on the actual annual discharge data for a specific NPP and radionuclide groups. By applying these to the actual yearly discharge data of 14 Korean NPPs for 7 radionuclide groups for the past 20 years, the applicability of two new methodologies to actual cases was demonstrated. The 'characteristic value' with approximately a 90% compliance probability for each Korean NPP and radionuclide group was proposed based on the results. The new approaches for setting up the discharge limits and the characteristic values developed in this study are expected to be effectively utilized to foster operator's efforts to progressively reduce the environmental releases of radioactive effluents of NPPs relative to the previous discharge data considering operational flexibilities.

농업용 저수지 관개 취약성 특성 곡선 산정 (Evaluation of Irrigation Vulnerability Characteristic Curves in Agricultural Reservoir)

  • 남원호;김태곤;최진용;김한중
    • 한국농공학회논문집
    • /
    • 제54권6호
    • /
    • pp.39-44
    • /
    • 2012
  • Water supply capacity and operational capability in agricultural reservoirs are expressed differently in the limited storage due to seasonal and local variation of precipitation. Since agricultural water supply and demand basically assumes the uncertainty of hydrological phenomena, it is necessary to improve probabilistic approach for potential risk assessment of water supply capacity in reservoir for enhanced operational storage management. Here, it was introduced the irrigation vulnerability characteristic curves to represent the water supply capacity corresponding to probability distribution of the water demand from the paddy field and water supply in agricultural reservoir. Irrigation vulnerability probability was formulated using reliability analysis method based on water supply and demand probability distribution. The lower duration of irrigation vulnerability probability defined as the time period requiring intensive water management, and it will be considered to assessment tools as a risk mitigated water supply planning in decision making with a limited reservoir storage.

Pilot Plant Study on Biological Nutrient Removal of Wastewater

  • Ahn, Sang-Jin;Kim, Geon-Heung;Ahn, Bok-Kyoun
    • Korean Journal of Hydrosciences
    • /
    • 제1권
    • /
    • pp.99-106
    • /
    • 1990
  • An extensive biological nutrient removal pilot plant study of anoxic/anaerobic/ aerobic treatment process was conducted to eastblish an optimum operational mode using primary dffluent. Two operational modes, (1) Qr/Q was 3.0 and maintaining EMLSS of 3100 mg/L in which the best operational results were obtained from previous bench scale study using synthetic wastewater (2) Qr/Q was 0.5 and EMLSS of 2200 mg/L which was compatible with the main plant, were Compared and evaluated for removal of nitrogen and/or phosphorous under field conditions. The nitrogen removal increased with increasing recycle ratios, but the phosphorous removal revealed more consistent results with 83percent removal efficiency in the second mode compared with 80 percent in the first mode. Above all, the two modes equally showed good BOD and nitrogen removals by nitrification-denitrification processes. It was also observed that no scum formed in the pilot plant and the sludge exhibited excellent settling characteristic all the time. The modified biological nutrient removal train can be adopted to the main plant without any major changes of their operational modes.

  • PDF

최적화 기법에 의한 발전시뮬레이션 방법론의 개발 및 전원확충계획 문제에의 적용 (The Development of Production Simulation Methodology by Optimization Technique and It's Application to Utility Expansion Planning)

  • 송길영;오광해;김용하;차준민
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1996년도 하계학술대회 논문집 B
    • /
    • pp.793-796
    • /
    • 1996
  • This study proposes a new algorithm which performs a production simulation under various constraints and maintains computational efficiency. In order to consider the environmental and operational constraints, the proposed algorithm is based on optimization techniques formulated in LP form In the algorithm, "system characteristic constraints" reflect the system characteristics such as LDC shape, unit loading order and forced outage rate. By using the concept of Energy Invariance Property and two operational rules i.e. Compliance Rule for Emission Constraint, Compliance Rule for Limited Energy of Individual Unit, the number of system characteristic constraints is appreciably reduced. As a solution method of the optimization problem, the author uses Karmarkar's method which performs effectively in solving large scale LP problem. The efficiency of production simulation is meaningful when it is effectively used in power system planning. With the proposed production simulation algorithm, an optimal expansion planning model which can cope with operational constraints, environmental restriction, and various uncertainties is developed. This expansion planning model is applied to the long range planning schemes by WASP, and determines an optimal expansion scheme which considers the effect of supply interruption, load forecasting errors, multistates of unit operation, plural limited energy plants etc.

  • PDF

FACTS 기기가 설치된 송전선로에서 거리계전기의 응동특성 (A Study of Distance Relay Characteristic of Transmission Line including FACTS Devices)

  • 정창호;서정남;방성원;김진오
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2000년도 하계학술대회 논문집 A
    • /
    • pp.31-33
    • /
    • 2000
  • This paper discusses the operational characteristic analysis of distance relay depending on the power system parameters in transmission line including FACTS devices. Distance relay requires protective coordination because the FACTS devices change power system parameters to increase power transmission capacity. In this paper, the dynamic operational characteristics of distance relay are analyed for the effect of fault resistance and operation mode of FACTS devices according to the installed points of these devices.

  • PDF

Synthesis of a planar 3 degree-of-freedom adjustible compliance mechanism

  • Kim, Whee-Kuk;Yi, Byung-Ju;Kim, Dong-Gu
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 1994년도 Proceedings of the Korea Automatic Control Conference, 9th (KACC) ; Taejeon, Korea; 17-20 Oct. 1994
    • /
    • pp.334-339
    • /
    • 1994
  • In this work, we propose a planar three degree-of-freedom parallel mechanism as another type of assembly device which utilized joint compliances. These joint compliances can be adjusted either by properly replacing the joint compliances or by actively controlling stiffness at joints, in order to generate the desired operational compliance characteristics at RCC point, The operational compliance matrix for this mechanism is explicitly obtained by symbolic manipulation and its operational compliance characteristics are examined, it is found that the RCC point exists at the center of the workspace when the mechanism maintains symmetric configurations. Compliance characteristic and its sensitivity of this mechanism is analyzed with respect to the magnitude of the diagonal compliance components and two different matrix norms measuring compliance sensitivity. It is expected that the analysis results provide the designer with a helpful information to determine a set of optimal parameters of this RCC mechanism.

  • PDF

Analog multiplier using operational amplifier

  • Petchmaneelumka, Wandee;Songsataya, Kiettiwan;Riewruja, Vanchai;Julsereewong, Prasit
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2005년도 ICCAS
    • /
    • pp.868-871
    • /
    • 2005
  • In this article, presents an analog multiplier using a general-purpose operational amplifier (opamp). The realization method is based on the quarter-square technique, which utilize the square-law characteristic of the class AB output stage of the opamp. The experimental results verifying the proposed multiplier performances are also included. The linearity error and the total harmonic distortion is about 0.8% and 1.6%, respectively.

  • PDF