• Title/Summary/Keyword: operation principle

Search Result 897, Processing Time 0.027 seconds

Design and Prototyping of a Novel Type Piezoelectric Micro-pump

  • Oh, Jin-Heon;Lim, Jong-Nam;Lee, Seung-Su;Heo, Jun;Lim, Kee-Joe
    • Transactions on Electrical and Electronic Materials
    • /
    • 제9권5호
    • /
    • pp.181-185
    • /
    • 2008
  • Using the extensional vibration mode of PZT ring, a piezopump is successfully made. The PZT ring is polarized with thickness direction. The traveling extensional wave along the circumference of the ring is obtained by dividing two standing waves which are temporally and spatially phase shifted by 90 degrees from each other. The proposed piezopump is consisted of coaxial cylindrical shells that are bonded piezoelectric ceramic ring. The pump takes an unobtrusive operation into the simple displacing mechanism using peristaltic traveling waves without the physical moving parts. The finite elements analysis on the proposed pump model is carried out to verify its operation principle and design by the commercial FEM software. Components of piezopump were made, assembled, and tested to validate the concepts of the proposed pump and confirm the simulation results. The performance of the proposed piezopump is about 580 ${\mu}l/min$ in flow rate with the highest pressure level of 0.85 kPa, when the driving voltage is 150 $V_p$, 57 kHz.

Fontan 술식의 치험 23례에 관한 고찰 (Twenty three experiences of Fontan operation)

  • 안재호
    • Journal of Chest Surgery
    • /
    • 제16권3호
    • /
    • pp.342-348
    • /
    • 1983
  • The Fontan principle of redirecting systemic venous blood into the pulmonary arteries via a conduit was initially proposed for Tricuspid Atresia, but it and its modifications have now gained a much wider application than initially intended. From September 1978 to July 1983, Atriopulmonary anastomosis has been performed in 23 patients, 2 months to 19 years of age, Seoul National University Hospital. The diagnoses were Tricuspid Atresia [TA] in 13, Univentricular Heart [UVH] in 9 and one case of Double Outlet of Right Ventricle [DORV]. Previous procedures included two Glenn shunts and one Blalock-Taussl8 shunt. Among these 23 patients, 10 patients had Right Atrial to Pulmonary Artery conduit, with a valve in 7 and without in 3. The remaining 13 patients had direct anastomosis between RA to PA. There were 14 early deaths, 7 of 13 TA patients, 6 of 9 UVH patients and one DORV, and the total hospital mortality was 60%. But there were no later deaths, 9 of these 23 patients survived operation and are presently alive. The Fontan procedure can be done with an acceptable low mortality with good functional results for Tricuspid Atresia and other complex lesion in foreign hospital, but till now our results revealed much higher risks. For our good operative results and effective patients selection, we must clarify the exact condition of pulmonary arterial system and accumulate much more experiences and technique.

  • PDF

Zero-Voltage and Zero-Current Switching Interleaved Two-Switch Forward Converter

  • Chu, Enhui;Bao, Jianqun;Song, Qi;Zhang, Yang;Xie, Haolin;Chen, Zhifang;Zhou, Yue
    • Journal of Power Electronics
    • /
    • 제19권6호
    • /
    • pp.1413-1428
    • /
    • 2019
  • In this paper, a novel zero-voltage and zero-current switching (ZVZCS) interleaved two switch forward converter is proposed. By using a coupled-inductor-type smoothing filter, a snubber capacitor, the parallel capacitance of the leading switches and the transformer parasitic inductance, the proposed converter can realize soft-switching for the main power switches. This converter can effectively reduce the primary circulating current loss by using the coupled inductor and the snubber capacitor. Furthermore, this converter can reduce the reverse recovery loss, parasitic ringing and transient voltage stress in the secondary rectifier diodes caused by the leakage inductors of the transformer and the coupled inductance. The operation principle and steady state characteristics of the converter are analyzed according to the equivalent circuits in different operation modes. The practical effectiveness of the proposed converter was is illustrated by simulation and experimental results via a 500W, 100 kHz prototype using the power MOSFET.

이중 제로터의 설계 및 응용 가능성에 대한 연구 (Design and Feasibility Study of Double Gerotor)

  • 이성철
    • Tribology and Lubricants
    • /
    • 제35권4호
    • /
    • pp.215-221
    • /
    • 2019
  • A gerotor set consists of two elements, an inner rotor and an outer rotor. The outer rotor has one more tooth than the inner rotor and has its centerline positioned at a fixed eccentricity from the centerline of the inner rotor. Although gerotors come in a variety of geometric configurations, all gerotor sets share the basic principle of having generated tooth profiles that provide continuous tight sealing during operation. The size of the gerotor is proportional to the number of teeth and the amount of eccentricity. The interior of an inner rotor with a large number of teeth has an enough space to include other machine elements. In this paper, the double gerotor mechanism, constructed by putting a small gerotor in the interior of a large inner rotor, is conceptualized. The double gerotor set is composed of an inner rotor, a planetary rotor, and an outer rotor. The inside profile of the planetary rotor corresponds to the outer rotor profile of the small gerotor, and the outside profile is the inner rotor profile of the large gerotor. In the double gerotor, the centers of the inner and the outer rotor are coincident because the eccentricities of two gerotors are balanced. The operation of a double gerotor is examined by analyzing the planetary motion, and a feasibility study for application of the double gerotor for hydraulic motors and pumps is performed. The double gerotor set has much application potential as a component of hydraulic systems.

Analysis and Implementation of LC Series Resonant Converter with Secondary Side Clamp Diodes under DCM Operation for High Step-Up Applications

  • Jia, Pengyu;Yuan, Yiqin
    • Journal of Power Electronics
    • /
    • 제19권2호
    • /
    • pp.363-379
    • /
    • 2019
  • Resonant converters have attracted a lot of attention because of their high efficiency due to the soft-switching performance. An isolated high step-up converter with secondary-side resonant loops is proposed and analyzed in this paper. By placing the resonant loops on the secondary side, the current stress for the resonant capacitors is greatly reduced. The power loss caused by the equivalent series resistance of the resonant capacitor is also decreased. Clamp diodes in parallel with the resonant capacitors ensure a unique discontinuous current mode in the converter. Under this mode, the active switches can realize soft-switching during both turn-on and turn-off transitions. Meanwhile, the reverse-recovery problems of diodes are also alleviated by the leakage inductor. The converter is essentially a step-up converter. Therefore, it is helpful for decreasing the transformer turn-ratio when it is applied as a high step-up converter. The steady-state operation principle is analyzed in detail and design considerations are presented in this paper. Theoretical conclusions are verified by experimental results obtained from a 500W prototype with a 35V-42V input and a 400V output.

Self-Feeder Driver for Voltage Balance in Series-Connected IGBT Associations

  • Guerrero-Guerrero, A.F.;Ustariz-Farfan, A.J.;Tacca, H.E.;Cano-Plata, E.A.
    • Journal of Power Electronics
    • /
    • 제19권1호
    • /
    • pp.68-78
    • /
    • 2019
  • The emergence of high voltage conversion applications has resulted in a trend of using semiconductor device series associations. Series associations allow for operation at blocking voltages, which are higher than the nominal voltage for each of the semiconductor devices. The main challenge with these topologies is finding a way to guarantee the voltage balance between devices in both blocking and switching transients. Most of the methods that have been proposed to mitigate static and dynamic voltage unbalances result in increased losses within the device. This paper introduces a new series stack topology, where the voltage unbalances are reduced. This in turn, mitigates the switching losses. The proposed topology consists of a circuit that ensures the soft switching of each device, and one auxiliary circuit that allows for switching energy recovery. The principle for the topology operation is presented and experimental tests are performed for two modules. The topology performs excellently for switching transients on each of the devices. The voltage static unbalances were limited to 10%, while the activation/deactivation delay introduced by the lower module IGBT driver takes place in the dynamic unbalances. Thus, the switching losses are reduced by 40%, when compared to hard switching configurations.

연안복합어선의 연승조업과정에 따른 선장의 주의 배분 (Allocation of the skipper's attention depending on the longline fishing process of the coastal composite fishing vessel)

  • 김민선;황보규
    • 수산해양기술연구
    • /
    • 제58권2호
    • /
    • pp.175-184
    • /
    • 2022
  • This study analyzed the allocation of the skipper's attention during fishing operation in the wheelhouse of a Korean coastal composite fishing vessel by using video observation. To summarize the results, the ratio of lookout, radar and GPS monitoring, which is essential for prevention of collision at sea, was significantly lower than that of other fishing operation due to the attention concentration on the work place during hauling line. In order to reduce exposure to risk of collisions due to concentration of attention to certain tasks such as line hauling, it is necessary to develop an alert system that can notify the approach of other ships or obstruction throughout the ship using information from radar or the automatic identification system. In addition, the order of attention allocation to devices and facilities obtained in this study is expected to be used as basic data for device or facility layout based on the principle of usage frequency in designing wheelhouse for coastal composite fishing vessels in the future.

항만하역 노동력의 효율적인 배분에 관하여 (On the Optimal Allocation of Labour Gangs in the Port)

  • Lee, Cheol-Yeong;Woo, Byung-Goo
    • 한국항만학회지
    • /
    • 제1권1호
    • /
    • pp.21-47
    • /
    • 1987
  • Nowaday all the countries of the world have studied the various problems caused in operating their own ports efficiently. Ship delay in the port is attributal to the inefficient operation in the navigation aids, the cargo handling, the storage and transfer facilities, and to the inefficient allocation of gangs or to a bad service for ships. Among these elements the allocation of gangs is the predominating factor in minimizing ship's turn round time. At present, in the case of Pusan Port. the labour union and stevedoring companies allocate gangs in every hatches of ships by a rule of thumb, just placing emphasis on minimizing ship's turn round time, without applying the principle of allocation during the cargo handling. Owing to this the efficiency of the cargo handling could not be expected to be maximized and this unsystematic operation result in supplying human resources of much unnecessary surplus gangs. Therefore in this paper the optimal size and allocation of gangs for minimizing the ship's turn round time is studied and formularized. For the determination of the priority for allocation the evaluation function, namely $F=PHi^{n}{\times}(W+H)$, can be obtained; where, PHI : Principal Hatch Index W : Total Cargo Weight represented in Gang-Shifts H : Total Number of Ship's hatches and also for the optimal size of gangs the average number of gang allocated per shift (Ng), namely Ng=W/PHI, is used. The proposed algorithm is applied to Pusan Port and its validity is verified.

  • PDF

시스템사고에 기반한 상수도 효율성 개선에 관한 연구: 충청북도를 중심으로 (A study on the improvement of efficiency for waterworks on the basis of the accidents in the system by setting the example of Chungcheongbuk-do)

  • 김나윤;김선덕;이만형
    • 한국시스템다이내믹스연구
    • /
    • 제17권2호
    • /
    • pp.81-99
    • /
    • 2016
  • The service for waterworks is important infrastructure structuring the cities and the public properties affecting the health and the abundant lives of the residents at the same time. However, the waterworks project still has many problems in reality in spite of the continuous efforts from the nation, local governments and many related people in waterworks projects. From the aspect of the situation, this purpose of this study is to review the actual operation state and the operation principle on the basis of the accidents in the system and to suggest the policy leverages for accurate diagnosis of the waterworks project and for the efficient operation. The operation structure of the service for waterworks is the complicated system showing the overlapped forms of the relation with other various factors. Moreover, as this has been influenced by other external environments, it has flexible features that can be changed by unexpected factors even if the internally close causality has been established The domestic local operation of waterworks have been divided by an administrative district and it causes inefficiency in the aspect of the country and the local government with small sized of budget faces the insufficient investments. These phenomena have been shown in some small sized areas located in Chungcheongbuk-do and, making a realistic suggestion by the related local government to improve the waterworks operation project is urgent. For this reason, this study is to lead the policy leverages to increase the efficiency of the service for waterworks and to stabilize the structure of virtuous circle in the system. At first, the reformation of the waterworks structure should be performed after the various supports and system maintenance. At second, the service quality should be improved through the creativity in management and the consideration of the efficiency by the participation of private enterprises for waterworks service. At third, through the specialized waterworks operation, the quality improvement of the waterworks and satisfying the standard of natural environment should be related. In this context, the fundamental solutions for the problems of domestic waterworks service and finding realistic alternatives are considered to be the priority for the waterworks project to be operated efficiently.

A Novel type of High-Frequency Transformer Linked Soft-Switching PWM DC-DC Power Converter for Large Current Applications

  • Morimoto Keiki;Ahmed Nabil A.;Lee Hyun-Woo;Nakaoka Mutsuo
    • Journal of Electrical Engineering and Technology
    • /
    • 제1권2호
    • /
    • pp.216-225
    • /
    • 2006
  • This paper presents a new circuit topology of DC busline switch and snubbing capacitor-assisted full-bridge soft-switching PWM inverter type DC-DC power converter with a high frequency link for low voltage large current applications as DC feeding systems, telecommunication power plants, automotive DC bus converters, plasma generator, electro plating plants, fuel cell interfaced power conditioner and arc welding power supplies. The proposed power converter circuit is based upon a voltage source-fed H type full-bridge high frequency PWM inverter with a high frequency transformer link. The conventional type high frequency inverter circuit is modified by adding a single power semiconductor switching device in series with DC rail and snubbing lossless capacitor in parallel with the inverter bridge legs. All the active power switches in the full-bridge inverter arms and DC busline can achieve ZVS/ZVT turn-off and ZCS turn-on commutation operation. Therefore, the total switching losses at turn-off and turn-on switching transitions of these power semiconductor devices can be reduced even in the high switching frequency bands ranging from 20 kHz to 100 kHz. The switching frequency of this DC-DC power converter using IGBT power modules is selected to be 60 kHz. It is proved experimentally by the power loss analysis that the more the switching frequency increases, the more the proposed DC-DC converter can achieve high performance, lighter in weight, lower power losses and miniaturization in size as compared to the conventional hard switching one. The principle of operation, operation modes, practical and inherent effectiveness of this novel DC-DC power converter topology is proved for a low voltage and large current DC-DC power supplies of arc welder applications in industry.