• Title/Summary/Keyword: operation of the Center

Search Result 4,865, Processing Time 0.042 seconds

RELIABLE OPERATION IN COMS GROUND CENTERS

  • Lim, Hyun-Su;Ahn, Sang-Il
    • Proceedings of the KSRS Conference
    • /
    • 2007.10a
    • /
    • pp.496-499
    • /
    • 2007
  • The COMS ground segment will operate the geostationary satellite continuously 24h/7days and deliver processed data to end-users with respect to the predefined schedule without delay. For reliable operation, each COMS ground center has internally dual-configuration for critical systems but impossible to every components. Any unexpected failure or regular maintenance to the single configured antenna system may lead the interruption of COMS service and operation. The natural disaster or external attack can destroy one ground center and the operation will be stopped. Therefore COMS program implements backup system remotely located in other centers. Even considering foreign geostationary systems, it's the best solution guaranteeing consistent system operation against internal failure or external disaster.

  • PDF

Long Term Operation and Improvement Reliability for SOFC System (SOFC 시스템의 장시간 운전 및 시스템 신뢰성 향상)

  • YI, YONG;SHIN, SEOCK JAE;PARK, SE JIN;KIM, MIN SOO;KIM, HYUNG JOONG;KIM, JUN HO;KIM, INHWAN;KIM, YONG SU
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.28 no.5
    • /
    • pp.502-511
    • /
    • 2017
  • Design, manufacture and operate the 700W Solid oxide fuel cell system suitable for housing. Except for BOP not produced domestically, most of the domestic BOPs were applied as much as possible. Finally, the system size was 350 liter. System performance was electric efficiency 44.64%, thermal efficiency 40.99%, total efficiency 85.62% at certificate authority. The system was operated for 4,500 hours, this operation time include automatically system on/off, E-stop for emergency stop, load trip for blackout and inverter error. There were that the system on/off were 26 times. System performance remains intact after system on/off.

Operational Efficiency Scheme of Mailing Center for Automation (자동화 중심 우편집중국 운영 효율화 방안)

  • Um Insup;Lee Hongchul;Kang Jungyun
    • Proceedings of the Korean Operations and Management Science Society Conference
    • /
    • 2003.05a
    • /
    • pp.999-1006
    • /
    • 2003
  • This research presents efficient operation schemes that is emphasized on mailing center's automation parts. We utilized the automation indicator to analyzed the mailing center system. For automation of the mailing center, we proposed the sorting automation alternative of registered mail, automation of conveyance system between workshops and the Up-Grade scheme for process improvement in mailing center. The selection of the registered mailing f s automation alternatives is composed of the AHP(Analytic Hierarchy Process) method. Through the analysis of the space and the quantity of materials, the simulation experiments are conducted to examine conveyance equipment possibility of the mailing center. By simplifying the mailing center conceptually, we proposed the upgrade of process for the mailing center system. The result of this research can give some ideas to people who are formulating a policy for the mailing center operation.

  • PDF

Technical Analysis on Existing Ship's Economical Operation (운항선 중심의 선박 경제운항 관리의 기술적 분석)

  • Kang, Nam-seon;Kim, Yong-dae;Yoon, Hyeon-kyu;Byeon, Sang-su
    • Journal of Advanced Navigation Technology
    • /
    • v.20 no.6
    • /
    • pp.519-527
    • /
    • 2016
  • The present study is concept research on the operation cost management of shipping firms, especially considering technology for economical ship operation of existing ships in units of voyage. The factors that influence economical ship operation management were identified by analyzing the current status of the shipping industry, the development of economical ship operation technologies, technological requirements, and the cost factors of ship operation. Economical operation of existing ships, especially, the economical operation of the units of each voyage, may minimize fuel cost and port charges. This requires low-load streaming cruise control, ballast control, optimal trim, optimal routing, terminal work efficiency improvement, and ship energy management. Optimal routing and terminal work efficiency improvement manage the time saved. To determine the low-load streaming, cruise control, ballast control, optimal trim and ship energy management are meeting the recommendations.

The application of Lean Six Sigma Methodology for Improving Operation in Distribution Center (물류센터 운영 개선을 위한 Lean Six Sigma 기법 적용)

  • Park, Sang-Min;Lee, Bum-Woo
    • Journal of the Korea Safety Management & Science
    • /
    • v.9 no.3
    • /
    • pp.95-102
    • /
    • 2007
  • Nowadays, globally high-grade companies have done their best for increasing their competitive power through a many kinds of method in incisive competition for making certain of a pacesetting position. Among the rest, Six Sigma have been the best methodology of improving process and have proven to be effective by the result of improving process in many of manufacturing business, however, it has not obtained excellent results in the transaction business. In transaction business, a $30\sim50%$ costs in total costs is generated by slow-speed working and reworking. The slow processes decrease the quality and increase the cost, which decreases customer satisfaction, and finally the income is decreased. All of them are so called wastes in processes. For this, adopting of lean six sigma methodology in process management can eliminate the wastes and reduce the variation. This study focuses on distribution with the domains like capacity, layout, amount of location, assignment of product, operation procedure and operation rule in order to improve these domains, we make a further application of eight analysis ways based on DMAIC method for improving operation of processes of distribution center as the third profit source. The goal of this study is to trace an approach that can easily adopt of Lean Six Sigma in operational management of distribution center by a kind of data, analysis method and template.

Analysis of Tilting Angle of KOMPSAT-1 EOC Image for Improvement of Geometric Accuracy Using Bundle Adjustment

  • Seo, Doo-Chun;Lee, Dong-Han;Kim, Jong-Ah;Kim, Yong-Seung
    • Proceedings of the KSRS Conference
    • /
    • 2002.10a
    • /
    • pp.780-785
    • /
    • 2002
  • As the KOMPSAT-1 satellite can roll tilt up to $\pm$45$^{\circ}$, we have analyzed some EOC images taken at different tilt angles fur this study. The required ground coordinates for bundle adjustment and geometric accuracy, are read from the digital map produced by the National Geography Institution, at a scale of 1:5, 000. These are the steps taken for the tilting angle of KOMPSAT-1 satellite to be present in the evaluation of the accuracy of the geometric of each different stereo image data: Firstly, as the tilting angle is different in each image, the satellite dynamic characteristic must be determined by the sensor modeling. Then the best sensor modeling equation is determined. The result of this research, the difference between the RMSE values of individual stereo images is due more the quality of image and ground coordinates than to the tilt angle. The bundle adjustment using three KOMPSAT-1 stereo pairs, first degree of polynomials for modeling the satellite position were sufficient.

  • PDF

A study on the safe operation condition for Bi-2223/Ag tapes with applied alternating currents (교류용 Bi-2223/Ag 선재의 안정 통전 조건에 관한 연구)

  • Yim S. W.;Sohn S. H.;Hwang S. D.;Lim S. H.
    • Progress in Superconductivity
    • /
    • v.6 no.2
    • /
    • pp.138-141
    • /
    • 2005
  • Bi-2223/Ag tapes need to be safe, even it is under the over-critical current state for the protection of a superconducting power machine. However, it is not easy to identify the condition for the safe operation because of their broad S/N transition region. In this paper, for the study of the operation condition of Bi-2223/ Ag tapes, we investigated the V-I curves and the temperature variation of Bi-2223/ Ag tapes experimentally, applying alternating over-currents, and analyzed the relationship between resistance and temperature increase. For the experiments, a Bi-2223/Ag tape of 57 A $I_c$ was prepared, and the over-critical current characteristics under adiabatic state from $LN_2$ was measured. From the experiments, we confirmed that the Joule heating predicted by V-I curve corresponded with the increase of the measured temperature exactly. Using the results, a safe operation condition of Bi-2223 tape was discussed.

  • PDF

DUAL DUTY CYCLE CONTROLLED SOFT-SWITCHING HIGH FREQUENCY INVERTER USING AUXILIARY REVERSE BLOCKING SWITCHED RESONANT CAPACITOR

  • Bishwajit, Saha;Suh, Ki-Young;Lee, Hyun-Woo;Mutsuo, Nakaoka
    • Proceedings of the KIEE Conference
    • /
    • 2006.10d
    • /
    • pp.129-131
    • /
    • 2006
  • This paper presents a new ZVS-PWM high frequency inverter. The ZVS operation is achieved in the whole load range by using a simple auxiliary reverse blocking switch in parallel with series resonant capacitor. The operating principle and the operating characteristics of the new high frequency circuit treated here are illustrated and evaluated on the basis of simulation results. It was examined that the complete soft switching operation can be achieved even for low power setting ranges by introducing the high frequency dual duty cycle control scheme. In the proposed high frequency inverter treated here, the dual mode pulse modulation control strategy of the asymmetrical PWM in the higher power setting ranges and the lower power setting ones, the output power of this high frequency inverter could introduce in order to extend soft switching operation ranges. Dual duty cycle is used to provide a wide range of output power regulation that is important in many high frequency inverter applications. It is more suitable for induction heating applications the operation and control principle of the proposed high frequency inverter are described and verified through simulated results.

  • PDF

A Study on the Performance and Operation Limit of Electrodialysis Cell for HI Concentration (HI 농축에 대한 전기투석 셀의 성능 및 운전한계조건 연구)

  • Lee, Byung-Woo;Jeong, Seong-Uk;Cho, Won-Chul;Kang, Kyoung-Soo;Park, Chu-Sik;Bae, Ki-Kwang;Kim, Young-Ho;Kim, Chang-Hee
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.22 no.6
    • /
    • pp.749-758
    • /
    • 2011
  • The present work explores the performance and operation limit of electrodialysis cell for HI concentration in sulfur iodine thermochemical hydrogen production process, For this purpose, the electrodialysis cell was assembled with Nafion 117 as a PEM membrane and two activated carbon papers as the electrodes. HIx solution was prepared with composition of HI: $I_2$: $H_2O$ = 1: 0.5~2.5: 5.2 in molar ratio. The cell and its peripheral apparatus were placed in the specially designed convective oven in order to uniformly maintain the operation temperature. As operation temperature increased, the amount of water transport from anode to cathode increased, thus reducing HI molarity in catholyte. Meanwhile, the current efficiency was constant as about 90 %, irrespective of temperature change. The cell voltage increased with initial $I_2$ mole ratio as well as anolyte to catholyte mole ratio. Moreover the cell voltage overshot took place within 10 h cell operation, which is due to the $I_2$ precipitation inside the cell. From the analysis of $I_2$ mole ratio in the anolyte, it is noted that operation limit (in $I_2$ mole ratio) of the electrodialysis cell, arising from was measured to be 3.2, which is much lower than bulk solubility limit of 4.7.

Evaluation of Operation Efficiency in the Korean RCC/RSC Using Fuzzy-Logic and DEA (퍼지로직과 DEA를 이용한 RCC/RSC별 운영효율성 평가)

  • Jang, Woon-Jae;Keum, Jong-Soo
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.12 no.4 s.27
    • /
    • pp.233-239
    • /
    • 2006
  • This paper aims to evaluate the operation efficiency of Korean RCC(Rescue Co-ordination Center)/RSC(Rescue Sub-Center) using DEA(Data Envelopment Analysis). for this evaluation, this paper use the quantitative data for DEA analysis with two inputs and four outputs and a qualitative data analysis with the use of expert assessment. The tool for integrating heterogeneous data is fuzzy logic model to decision support system. In this paper, therefore, RCC/RSC evaluates the priority for operation efficiency. The result are found as order as Inchon, Mokpo, Jeju, Donghae, Busan, Pohang, Yosu, Sokcho, Tongyeong, Ulsan, Taean, Gunsan RSC.

  • PDF