• Title/Summary/Keyword: operation indices

Search Result 208, Processing Time 0.029 seconds

Quality and Environmental Performance Indices for Electrical Appliance Recycling in Taiwan

  • Shih, Li-Hsing;Lan, Yuan-Bo
    • Proceedings of the IEEK Conference
    • /
    • 2001.10a
    • /
    • pp.65-70
    • /
    • 2001
  • Six recycling plants have started operation for recycling scrap home appliances since the spring of 2000 in Taiwan. The performance of the plants has not yet been measured during the 18-month period. The performance measurement, however, can be looked in several aspects. Because of the nature of these recycling plants, at least three aspects, namely government (representing general public), appliance manufacturers and owners of the recycling plants themselves should be considered in the performance evaluation. This study proposes various performance indices categorized in four groups: profitability, recyclability, automation and environment. The indices are different from the productivity and cost measures that are used in conventional manufacturing plants. Performances of three existing plants in Taiwan are evaluated as illustrative examples to demonstrate the use of the proposed measures. The practical implications of the performance indices are also discussed.

  • PDF

Optimal Operation of Dispersed Generation in MicroGrid Systems (마이크로 그리드에서 분산전원의 최적 운영 방안)

  • Kim, Kyu-Ho;Rhee, Sang-Bong;Kim, Soo-Nam;Lee, Sang-Keun
    • Proceedings of the KIEE Conference
    • /
    • 2009.07a
    • /
    • pp.486_487
    • /
    • 2009
  • This paper presents a method for optimal operation to improve reliability of MicroGrid systems considering load types and interruption cost. The objective functions such as power losses cost, operation cost of dispersed generations, power purchasing cost, and interruption cost are minimized for reliability improvement and efficient operation. The several indices for reliability evaluation are improved by renewable energy sources installation.

  • PDF

Calculating and Improving Operational Decision-Making Indices for Public Railways by Inclusion of Non-economic Factors (비경제성 요소를 포함한 철도운행 의사결정을 위한 지표 산정 및 개선에 관한 연구)

  • Yang, Jungyu;Ha, Ohkeun;Kim, Ikhee
    • Journal of the Korean Society for Railway
    • /
    • v.16 no.1
    • /
    • pp.65-70
    • /
    • 2013
  • In many cases, operation of regional trunk lines is not profitable to railway operators. Nevertheless, railway operators are under pressure to manage regional trunk lines running under deficits, to better serve public interests. Given this situation, railway operators need to optimize assets by adjusting train schedules or changing the number of trains running. When railway operators judge the operation of a regional trunk line, the B/C ratio is generally used as a management index. This ratio is not considered part of strategic operational policy over the long term, and excessively influenced by the aspects of supply and demand over the short term. Accordingly, this study focused on indices that might be used to prevent worsening deficits and provide long term strategic operation policies, main indices to better measure economic situations, and auxiliary indices to supplement the main index. The main indices were measured in conventional ways to target experts and employees. This study presents quantitative standards, which are intended to be used to create itemized criteria through an Analytic Hierarchy Process, for better decision-making.

A Study on Operation Problems for the Emergency Medical Process Using Real-Time Data (실시간데이터를 활용한 응급의료 프로세스 운영에 관한 연구)

  • Kim, Daebeom
    • Journal of the Korea Society for Simulation
    • /
    • v.26 no.3
    • /
    • pp.125-139
    • /
    • 2017
  • Recently, interest in improving the quality of EMS(emergency medical services) has been increasing. Much effort is being made to innovate the EMS process. The rapid progress of ICT technology has accelerated the automation or intelligence of EMS processes. This study suggests an emergency room management method based on real-time data considering resource utilization optimization, minimization of human error and enhancement of predictability of medical care. Emergency room operation indices - Emergency care index, Short stay index, Human error inducing index, Waiting patience index - are developed. And emergency room operation rules based on these indices are presented. Simulation was performed on a virtual emergency room to verify the effectiveness of the proposed operating rule. Simulation results showed excellent performance in terms of length of stay.

The Effect of Application of Injury Area to Overcrowding Indices in Local Emergency Department (지역응급의료센터에서 손상구역 운용이 응급실 과밀화 지표에 미치는 영향)

  • Kang, Jin Wook;Shin, Sang Do;Suh, Gil Joon;You, Eun Young;Song, Kyoung Jun
    • Journal of Trauma and Injury
    • /
    • v.20 no.2
    • /
    • pp.77-82
    • /
    • 2007
  • Purposes: There have been many efforts to improve the service of emergency centers. In spite of these, no evidence is showing any landmark advancement of emergency services, especially in the hospital stage, exists. We need some efficient standard criteria to evaluate emergency service in the hospital stage, and a useful method might utilize the overcrowding index. We want to know the change in the overcrowding index at a regional emergency center after injury area administration. Injury area means an area in which only an assigned duty physician manages patients with injuries such as those from traffic accidents, falls, assualts, collisions, lacerations, amputations, bums, intoxication, asphyxia, drowning, animal bites, sexual assualts, etc. Methods: We started to operate an injury area in our emergency department from late 2004, and from January to June in 2004 and in 2005, we collected patients' data, age, sex, assigned department, and result from hospital order communication system to figure out overcrowding indices and result indices. We found the daily number of patients, the turnover rate, the admission rate, the ICU admission rate, the emergency operation rate, the ED stay duration, and the ED patient volume to be overcrowding indices. Also we found the withdrawal rate, the transfer rate, and mortality to be result indices. We compared these indices between 2004 to 2005 by using a t-test. Results: There was a significant increase in the daily number of visiting patients in 2005, overcrowding indices, such as the turnover rate, the admission rate, the ICU admission rate, and the emergency operation rate, also showed statistically significant increases in 2005 (P<0.001). As for the result indices, there was a noticeable decrease in the number of withdrawals (11.77/day in 2004 to 4.53/day in 2005). Conclusion: Operating an injury area in a mildly overcrowded local emergency center is beneficial. Evaluating the effect of operating an injury area and it's impact on hospital finances by conducting a similar study analyziing patients for a longer duration would be valuable.

Early Postoperative Hemodynamic Changes in Patients of Congenital Complex Heart Disease using Blood Cardioplegic Solution (Blood cardioplegic solution을 사용한 선천성 복잡 심기형 환자의 술 후 조기 혈류학 변화에 관한 연구)

  • Kim, Yeong-Tae;Kim, Yong-Jin
    • Journal of Chest Surgery
    • /
    • v.25 no.11
    • /
    • pp.1192-1202
    • /
    • 1992
  • Postoperative cardiac outputs and other hernoaynamic values were serially measured in fifteen patients of cyanotic congenital heart disease, after use of blood cardioplegic solution. Cardiac indices showed no change untill eight postoparative hours, then it began to decline to reach as low as 3.22$\pm$0.7L/min/m2 at 12 hours. After then gradual increse occ-ured to recover upto immediate postoperative value at 20 hours. Sharp decrese of heart rate and increse of systemic vascular resistance during 8~16 hours and steady increase of stroke indices during the whole study periods were observed. These observations suggested that the myocardium recovered gradually after open heart surgery, and that the decrease of cardiac indices during 8~16 hours could be a result of decrease of heart rates and increase of afterload. The changes of cardiac indices correlated with the changes of heart rate, postoperative time and mixed venous oxygen saturation [p<0.05]. No other hemodynamic values found to be in statistically significant correlation with the changes of cardiac indices. Left ventricular dysfunction seemed to occur more frequently during 8~12 hours, but it was not statistically significant. [p=0.73] In conclusion, great care must be taken during 2~3 days after the operation of cyanotic congenital heart disease, not to fall into a low cardiac output state, by maintaing adequate heart rates and reducing afterload especially when the systemic vascular resistance increases.

  • PDF

A Novel Method for Clustering Critical Generator by using Stability Indices and Energy Margin (안정도 지수와 에너지 마진을 이용한 불안정 발전기의 clustering 법)

  • Chang Dong-Hwan;Jung Yun-Jae;Chun Yeonghan;Nam Hae-Kon
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.54 no.9
    • /
    • pp.441-448
    • /
    • 2005
  • On-line dynamic security assessment is becoming more and more important for the stable operation of power systems as load level increases. The necessity is getting apparent under Electricity Market environments, as operation of power system is exposed to more various operating conditions. For on-line dynamic security assessment, fast transient stability analysis tool is required for contingency selection. The TEF(Transient Energy Function) method is a good candidate for this purpose. The clustering of critical generators is crucial for the precise and fast calculation of energy margin. In this paper, we propose a new method for fast decision of mode of instability by using stability indices. Case study shows very promising results.

Probabilistic Reliability Evaluation of KEPCO System using TRELSS - V (TRELSS를 이용한 우리나라의 확률론적 신뢰도 평가에 관한 연구 - V)

  • Jeon D.;Kim T.;Cha S.;Choo J.;Tran T.;Lee S.;Choi J.
    • Proceedings of the KIEE Conference
    • /
    • summer
    • /
    • pp.11-14
    • /
    • 2004
  • In recent, the importance and necessity of some studies on reliability evaluation of grid comes from the recent black-out accidents occurred in the world. The quantity evaluation of transmission system reliability is very important under competitive electricity environment. The reason is that the successful operation of electric power under the deregulated electricity market depends on transmission system reliability management. This paper introduces features and operation modes of the Transmission Reliability Evaluation for Large-Scale Systems(TRELSS) Version 6.2, a program made in EPRI, for assessing reliability indices of composite power system. The package accesses not only bulk but also buses indices for reliability evaluation of composite powers system. The characteristics of the TRELSS program are illustrated by the case studies using the KEPCO system

  • PDF

The Enhancement of Power System Security Using flexible AC Transmission Systems (FACTS) (FACTS 기기를 이용한 전력시스템의 안전도 향상)

  • 송성환;임정욱;문승일
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.52 no.3
    • /
    • pp.165-172
    • /
    • 2003
  • This paper presents an operation scheme to enhance the power system security by applying FACTS on Power systems. Three main generic types of FACTS devices are suggested an illustrated. Flow congestions over lines have been solved by controlling active power of series-compensated FACTS devices and low voltages at buses have been solved by controlling reactive power of shunt-compensated FACTS devices. Especially, Especially, UPFC has been applied in both line congestion and low voltages. Two kinds of indices which indicate the power system security level related to line flow and bus voltage are utilized in this paper. They have been minimized to enhance the power system security level through the iterative method and the sensitivity vector of security index is derived to determine the direction to minimum. The proposed algorithm has been tested on the IEEE 57-bus system with FACTS devices in a normal condition and a line-faulted contingency.

Probabilistic Reliability Evaluation of Power System using TRELSS I (TRELSS를 이용한 전력계통의 확률론적 신뢰도 평가 I)

  • Kang, Sung-Rok;Tran, Tungtinh;Choi, Jae-Sok;Jeon, Dong-Hoon;Moon, Seung-Pil;Choo, Jin-Boo
    • Proceedings of the KIEE Conference
    • /
    • 2003.11a
    • /
    • pp.62-66
    • /
    • 2003
  • In recent, the importance and necessity of some studies on reliability evaluation of grid comes from the recent black-out accidents occurred in the world. The quantity evaluation of transmission system reliability is very important under competitive electricity environment. The reason is that the successful operation of electric power under the deregulated electricity market depends on transmission system reliability management. This paper introduces features and operation modes of the Transmission Reliability Evaluation for Large-Scale Systems(TRELSS) Version 5_1, a program made in EPRI, for assessing reliability indices of composite power system. The package accesses not only bulk but also buses indices for reliability evaluation of composite powers system. The characteristics of the TRELSS program are illustrated by the case studies using the IEEE 25buses system.

  • PDF