• Title/Summary/Keyword: operation factor

Search Result 2,754, Processing Time 0.028 seconds

New Controller for Power Factor and Harmonics Compensation of Single-Phase PWM Converter without AC Voltage Sensor (단상 PWM 컨버터의 역률 및 고조파 보상을 위한 교류전압 검출기가 없는 새로운 제어기)

  • Jon, Y.S.;Baek, S.T.;Kim, H.J.;Han, B.M.
    • Proceedings of the KIEE Conference
    • /
    • 2003.10b
    • /
    • pp.161-165
    • /
    • 2003
  • In this paper, A new controller for power factor and harmonics compensation of a single-phase PWM converter is described. The proposed controller requires only the dc voltage sensor and the at current sensor to compensate the power factor and harmonics. Detail simulation model with EMTBC (Electro-Magnetic Transient program for DC transmission) including power circuit and controller was developed to verify the operation of proposed controller. The application feasibility of the proposed controller was verified through experimental works with a prototype. The proposed controller has a simple structure in the point of hardware implementation, and shows excellent performance in normal operation as well as in sudden load change.

  • PDF

A Study on the Generator Capability Curve (발전기(發電機)의 가능출력곡선(可能出力曲線)에 관한 연구(硏究))

  • Park, Seong-Jin;Nam, Si-Bok
    • Proceedings of the KIEE Conference
    • /
    • 1999.11a
    • /
    • pp.35-42
    • /
    • 1999
  • As our power system has changed the past undeveloped model causing the lacked supply of power to the civilized model that the remained one makes the voltage and the frequency rise at the middle of the night, the leading power factor operation of generators, that is, the under-exited operation is essentially to be needed, so, at a viewpoint of the stability of the power system, it is a very important factor. In this investigation. the equation of curves for each area on the capability curve has been studied at the above-mentioned viewpoint. Also, each capability curve for the operating power stations (Nuclear P/S, Thermal P/S, Hydrolic & pumping-up P/S Gas turbine P/S) has, been presented, and studied whether the leading power factor operational area is able to be expanded or not.

  • PDF

Analysis of the Distribution STATCOM for Improving the power factor and Mitigation of Voltage Flicker in Real System (전압플리커 저감과 역률 보상 기능을 갖는 배전용 STATCOM의 실계통연계 운전결과 분석)

  • Oh, Kwan-Il;Jeon, Young-Soo;Park, Sang-Tae;Choo, Jin-Boo
    • Proceedings of the KIEE Conference
    • /
    • 2000.07a
    • /
    • pp.245-248
    • /
    • 2000
  • This paper presents the test and operation results of the domestic demonstration of the reactive power compensation device called STATCOM (STATic COMpensator). The object of the paper is to describe the reliability of the unit based on the extensive operation databases. By controlling reactive power, the technology offers utilities the opportunity for increased efficiency and their capabilities will permit transmission planners make the best use of their existing transmission resources STATCOM is a custom power device in a way and can be used in a similar way for the dynamic compensation of power transmission systems, mitigation of voltage flicker and improving the power factor. It is shown that the STATCOM has clear advantages in areas such as: mitigation of voltage flicker and improving power factor.

  • PDF

An Integrated Single-Stage Zero Current Switched Quasi-Resonant Power Factor Correction Converter with Active Clamp Circuit (능동 클램프 회로를 적용한 단상 ZCS 공진형 역률개선 컨버터)

  • 이준영;문건우;고관본;윤명중
    • Proceedings of the KIPE Conference
    • /
    • 1999.07a
    • /
    • pp.626-630
    • /
    • 1999
  • A new integrated single-stage zero current switched(ZCS) quasi-resonant converter (QRC) for the power factor correction(PFC) converter is introduced in this paper. The power factor correction can be achieved by the discontinuous conduction mode(DCM) operation of an input current. The proposed converter has the characteristics of the good power factor, low line current harmonics, and tight output regulation. Furthermore, the ringing effect due to the output capacitance of the main switch can be eliminated by use of active clamp circuit.

  • PDF

A Characteristic Study on the Power Factor Correction Application for Induction Motor (유도전동기에 대한 역률 보상설비의 특성 해석)

  • Kim, Jong-Gyeum;Park, Young-Jeen
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.22 no.9
    • /
    • pp.25-31
    • /
    • 2008
  • The field of induction motor is magnetized and demagnetized for each reversal of the current. This field component of the motor accounts for most of the reactive component of inductive load. Reactive power needs to sustain the electromagnetic field required for the induction motor to operate. Power factor of induction motor is usually low and power factor correction needs. Power factor becomes low by the effect of the reduction operation of load capacity. In most cases, Capacitor capacity for the power factor correction should be complied with the recommendation by the motor capacity. But Capacitor value for power factor correction can't change during the normal operation. In this paper, we analyzed characteristics of power and power factor changing by load fluctuation of low-voltage small size induction motor and show that lower power factor correction's parameter of existing recommendation should be revised by new value.

Examining Importance of Urban Rotorcraft Operations Using Analytic Hierarchy Process

  • Hye-Jin, Hong;Yong-og, Kim;Sungkwan, Ku
    • International Journal of Advanced Culture Technology
    • /
    • v.10 no.4
    • /
    • pp.487-498
    • /
    • 2022
  • This study aims to determine the importance of each factor considered when operating a rotorcraft in a city. After identifying factors that could affect urban air mobility, we reviewed the influencing factors by applying an analytic hierarchy process (AHP). Level 1 classifies the essential factors of the urban operation of rotorcraft in nominal and off-nominal situations. The factors corresponding to the characteristics of each were composed of lower levels, such as Levels 2 and 3. Using this, the importance of influencing factors was analyzed and the most important factors were determined. The most influential factors of the urban operation of rotorcraft included engine failure, fire situations, and vehicle safety. Accordingly, an environment that can guarantee safe operation by considering the most influential factors in advance in an actual operation stage must be constructed.

An Empirical Analysis on Public Transportation Demand and TOD Design Factors in Seoul subway adjacent area (서울시 역세권의 TOD환경과 대중교통이용수요 관계분석)

  • Moon, Young-Il;Rho, Jeong-Hyun
    • International Journal of Highway Engineering
    • /
    • v.13 no.4
    • /
    • pp.211-220
    • /
    • 2011
  • TOD(Transit Oriented Development) has recently been active, which presents that TOD planning elements should be comprehensively taken into consideration in order to enhance domestic transit ridership by changing environments in rail station areas and an empirical analysis on the type of rail station areas and transportation demand should be a prerequisite for usage of future development planning. This study aims to grasp a variety of TOD of influence factors in Seoul rail station area and to perform analysis to identify relationship between public transportation demand and these TOD design factors. To make it come true, we gathered data with respect to Density, Diversity, and Accessibility as representative TOD planning elements and carried out factorial and regression analysis. Consequently, we drew 7 influence factors base on factorial analysis: Factor 1(Diversity/ -Use Mix(LUM)), Factor 2(Density/development density), Factor 3(Accessibility/public transportation facility supply), Factor 4(Design/street design), Factor 5(Green/access mode (pedestrian, bike), Factor 6(Design/subway size), Factor 7(Accessibility/Public transit operation) As the result of model development by using factorial and regression analysis, positive influence factors on passenger flow in rail station area are Factor 1(Diversity : Land-Use Mix), Factor 3(Accessibility : public transportation facility supply), Factor 2(Density : development density), Factor 5(Design/ access mode) and Factor 6(subway size) Next, negative influence factor on passenger flow in rail station area shows Factor 7(Accessibility/Public transit operation) as the most influential factor. This is because the growth of service interval of linked subway and bus leads to reduced demand.

Extraction of Primary Factors Influencing Dam Operation Using Factor Analysis (요인분석 통계기법을 이용한 댐 운영에 대한 영향 요인 추출)

  • Kang, Min-Goo;Jung, Chan-Yong;Lee, Gwang-Man
    • Journal of Korea Water Resources Association
    • /
    • v.40 no.10
    • /
    • pp.769-781
    • /
    • 2007
  • Factor analysis has been usually employed in reducing quantity of data and summarizing information on a system or phenomenon. In this analysis methodology, variables are grouped into several factors by consideration of statistic characteristics, and the results are used for dropping variables which have lower weight than others. In this study, factor analysis was applied for extracting primary factors influencing multi-dam system operation in the Han River basin, where there are two multi-purpose dams such as Soyanggang Dam and Chungju Dam, and water has been supplied by integrating two dams in water use season. In order to fulfill factor analysis, first the variables related to two dams operation were gathered and divided into five groups (Soyanggang Dam: inflow, hydropower product, storage management, storage, and operation results of the past; Chungju Dam: inflow, hydropower product, water demand, storage, and operation results of the past). And then, considering statistic properties, in the gathered variables, some variables were chosen and grouped into five factors; hydrological condition, dam operation of the past, dam operation at normal season, water demand, and downstream dam operation. In order to check the appropriateness and applicability of factors, a multiple regression equation was newly constructed using factors as description variables, and those factors were compared with terms of objective function used in operation water resources optimally in a river basin. Reviewing the results through two check processes, it was revealed that the suggested approach provided satisfactory results. And, it was expected for extracted primary factors to be useful for making dam operation schedule considering the future situation and previous results.

Real time control special quality research for $CO_2$ laser's output change rate stability for accumulation style surgical operation rehabilitation of ventriculus that use Photosensor (Photosensor를 이용한 재활 치료형을 위한 $CO_2$ laser 의 출력변동율 안정을 위한 실시간 제어특성 연구)

  • Kim, Whi-Young
    • Proceedings of the IEEK Conference
    • /
    • 2006.06a
    • /
    • pp.1015-1016
    • /
    • 2006
  • The important parameters deciding the fluctuation of Accumulation style surgical operation of ventriculus laser beam are smoothing capacitor, frequency and he characteristics of laser resonator. In this thesis, we control the fluctuation of medical $CO_2C$ laser in realtime by changing Duty-Ratio of IGBT and switching frequency with fixed the smoothing capacitor to improve the fluctuation of laser beam. We detect the light on laser resonator using a CdS photo sensor to improve ripple factor of laser beam and feedback fluctuated signals refined by a band pass filter into the control circuit to stabilize fluctuation actively. There is much to be desired in the realtime controlling technique of the light on Accumulation style surgical operation of ventriculus laser discharge tube in electrical signal. We propose switching control technique with microprocessor and photo sensing technique by controlling switch devices optimum operation and feedback signals detected by a photo sensor into the laser power supply in order to improve ripple factor of the $CO_2$ laser beam.

  • PDF

Loss Analysis of Three Phase Induction Motor Connected to Single Phase Source (단상전원에 접속된 3상 유도전동기의 손실분석)

  • Kim, Do-Jin;Jwa, Chong-Keun
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.57 no.2
    • /
    • pp.121-126
    • /
    • 2008
  • This paper analyzes the losses of a Steinmetz connection three-phase induction motor which is supplied by a single-phase source. The T-type equivalent circuit which is taken no-load losses into account is used to determine phase converter capacitive reactances at starting and rated speed by using the condition of the minimum voltage unbalance. The starting and the operating capacitor are replaced at the slip of the same voltage unbalance factor points which are depicted using two capacitive reactances. The operation characteristics are investigated by comparing with those of three-phase balanced operation to find the feasibility of single-phase operation. To analyze the losses of this motor, the output power decrease factor(OPDF), the loss ratio(LR), the no load loss ratio(NLLR), the copper loss ratio(CLR), the stator copper loss ratio(SCLR), and the rotor copper loss ratio(RCLR) are defined and simulated in the whole slip range. The simulated results show that OPDF is maintained almost uniformly, LR is low at low speed and high at high speed, CLR is higher !ban NLLR, but CLR varies concavely and NLLR varies convexly at high speed, SCLR is low at low speed and high at high speed, but SCLR varies convexly at high speed, and RCLR is nearly opposite to SCLR.