• Title/Summary/Keyword: operation Modes

Search Result 815, Processing Time 0.028 seconds

Analysis and Design of a New Topology of Soft-Switching Inverters

  • Chen, Rong;Zhang, Jia-Sheng
    • Journal of Power Electronics
    • /
    • v.13 no.1
    • /
    • pp.51-58
    • /
    • 2013
  • This paper proposes the power conversion mechanism of a bailer-charge-transfer zero-current-switching (CT-ZCS) circuit. The operation modes are analyzed and researched using state trajectory equations. The topology of CT-ZCS based on soft-switching inverters offers some merits such as: tracking the input reference signal dynamically, bearing load shock and short circuit, multiplying inverter N+1 redundancy parallel, coordinating power balance for easy control, and soft-switching commutation for high efficiency and large capacity. These advantages are distinctive from conventional inverter topologies and are especially demanded in AC drives: new energy generation and grid, distributed generation systems, switching power amplifier, active power filter, and reactive power compensation and so on. Prototype is manufactured and experiment results show the feasibility and dynamic voltage-tracking characteristics of the topology.

A study on the rotating machine characteristics drived by chopper (초퍼 회로를 사용한 회전기계의 특성해석에 관한 연구)

  • 이승원
    • 전기의세계
    • /
    • v.29 no.6
    • /
    • pp.393-400
    • /
    • 1980
  • It is shown in this paper that it is possible to derive generalized state equations for computation of electrical circults constanining SCR and diode elements. Revankar's binary logic variable method is used for formulation of the state equation of chopper circuit. Advantage of this method is that the state equations can be set up without the exact knowledge of the circuit operaton. The different modes of operation of the circuit are identified by the computer itself. By applying this method, the steady state performances of separately excited chopper-fed dc motor considering the counter electromotive force of the motor are investigated and the results of the computer simulation are presented. There is a satisfactory agreement between the theoretical and experimental results.

  • PDF

Analytical Coexistence Benchmark for Assessing the Utmost Interference Tolerated by IEEE 802.20

  • Abdulla, Mouhamed;Shayan, Yousef R.
    • Journal of Information Processing Systems
    • /
    • v.7 no.1
    • /
    • pp.43-52
    • /
    • 2011
  • Whether it is crosstalk, harmonics, or in-band operation of wireless technologies, interference between a reference system and a host of offenders is virtually unavoidable. In past contributions, a benchmark has been established and considered for coexistence analysis with a number of technologies including FWA, UMTS, and WiMAX. However, the previously presented model does not take into account the mobility factor of the reference node in addition to a number of interdependent requirements regarding the link direction, channel state, data rate and system factors; hence limiting its applicability for the MBWA (IEEE 802.20) standard. Thus, over diverse modes, in this correspondence we analytically derived the greatest aggregate interference level tolerated for high-fidelity transmission tailored specifically for the MBWA standard. Our results, in the form of benchmark indicators, should be of particular interest to peers analyzing and researching RF coexistence scenarios with this new protocol.

The Design Criteria and Conduction Noise Reduction of Electronic Ballasts (전자식안정기의 설계기준 및 전도노이즈 저감)

  • 권진욱;최인식;박영진;윤덕종;홍순찬
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.43 no.3
    • /
    • pp.409-419
    • /
    • 1994
  • This paper deals with the design criteria and conduction noise reduction of electronic ballast system which is based on half-bridge series inverters. The system is theoretically analyzed in six modes and operating frequency range is selected to obtain the high efficacy and no sound noise. It is proposed the criteria for determining the values of L and C which are the dey points in system design Because of high operating frequency, electromagnetic noise, especially conduction noise, is a serious problem in electronic ballasts. To reduce the conduction noise, the operation and attenuation characteristics of noise filter are analyzed and the method to determine the values of filter elements is proposed. Also, the parasitic components of the inductor and capacitor are taken into consideration in filter analysis. Digital simulations and experiments are carried out to prove the theoretical results. And perfor mances of the system are verified through tests.

How Much Development Can a Rail Station Lead? A Case Study of Hong Kong

  • Xue, Charlie Qiuli;Sun, Cong
    • International Journal of High-Rise Buildings
    • /
    • v.7 no.2
    • /
    • pp.95-109
    • /
    • 2018
  • Since the concept was first introduced in the 1970s, transit-oriented-development (TOD) has greatly expanded in East Asian cities such as Hong Kong. Rail stations are built together with clusters of residential-commercial towers and government services to form a new style of living - a "rail village." This paper examines the composition, scale, spatial form, organization and operation of several typical rail villages in Hong Kong. The cases range across those planned from the mid-1990s to 2015. Based on the analysis of the rail village composition, the paper derives a development ratio to indicate the density, effectiveness and efficiency of a rail village catchment area. The ratio provides a useful and direct figure for the comparison of different stations, cities and development modes.

Failure Management Plan of the Rubber-Tired AGT Light Rail Vehicle (고무차륜 AGT 경량전철 차량의 고장관리 계획)

  • Kim Y.S.;Park S.H.;Lee A.H.;Han S.Y.
    • Proceedings of the KSR Conference
    • /
    • 2003.05a
    • /
    • pp.139-144
    • /
    • 2003
  • This study was aimed to establish failure management plan of the rubber-tired AGT light rail vehicle for its safety case, which was developed according to the Korean standardized specifications for the light rail vehicle. Vehicular 9 failure modes anticipated during the system operation were considered, which are single malfunction of redundant equipment, malfunction of train radio, public address and air compressor, battery, main circuit NFB trip, on-board ATO control device malfunction, on-board ATP control device malfunction, fail of brake release, flat tire, train emergency door open.

  • PDF

Torque ripple reduction of a closed-loop driven permanent magnet stepping motor by lead angle control (Lead angle 제어에 의한 폐루프 운전 영구자석형 스테핑 전동기의 토오크 리플 저감)

  • Lee, Hyun-Chang;Jun, Ho-Ik;Woo, Kwang-Joon
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.3 no.3
    • /
    • pp.280-288
    • /
    • 1997
  • In this paper, we will show that the torque ripple in closed-loop drives of permanent magnet stepping motors is reduced as properly selected lead angle control method. We propose an instantaneous torque equation, which is the function of lead angle, to estimate the influence on torque ripple. We design a closed-loop lead angle control system based on the proposed instantaneous torque equation and measure the instantaneous torque in various excitation modes. It is shown that torque ripple is greatly reduced, as seen from the experimental results as well as from the computer simulation results. For example, torque ripple reduced from 78.25% to 46.82% in the case of 50 PPS single-phase excitation mode operation.

  • PDF

Liquid Crystal Modes for Display Applications (디스플레이 응용을 위한 액정 모드)

  • Kim, Jung-Wook;Yoon, Tae-Hoon
    • Korean Journal of Optics and Photonics
    • /
    • v.24 no.4
    • /
    • pp.168-175
    • /
    • 2013
  • An information display device is a key component in the information society. A liquid crystal display is the most widely used among information display devices. However, its performance still needs to be improved in order to survive in competition with other information display devices. In this paper, we explain the structure and the operation principle of a liquid crystal display device and introduce our recent research activities on liquid crystal mode technology.

Experiments of Smoke Behavior in an Underground Subway Station (지하역사에서의 화재연기거동 실험)

  • Kim, Dong-Hyeon;Jang, Yong-Jun;Park, Won-Hee
    • Journal of the Korean Society for Railway
    • /
    • v.10 no.1 s.38
    • /
    • pp.67-73
    • /
    • 2007
  • Experiments were carried out to investigate smoke movement in platform of a subway station which currently is in service in Pusan, the second largest city in Korea. The recently constructed underground station of the "bank type" (two platforms on both sides of track) which is the popular layout of platforms in Korea, is chosen in Pusan. The smoke generator and heater are used for simulating the smoke movement at the fire break in the platform located in the 2nd basement of the station. Video recordings were used to monitor smoke lowering. In this study, the movements of smoke in the underground station are investigated under various smoke-control operating modes. Three tests wire conducted according to its operating mode of the ventilation systems in the platform: no operation of any ventilation systems, smoke extraction mode in occurrence of fire (presently running mode) and full capacity of smoke extraction where all vents are activated in the platform. The results can be used for comparing with the numerical prediction results of fire subway stations.

A Three-Phase Parallel Active Power Filter Operating with PCC Voltage Compensation by Controlling Reactive Power (무효전력 제어에 의한 PCC전압 보상을 갖는 삼상 병렬형 능동전력필터)

  • Lee, U-Cheol;Hyeon, Dong-Seok;Lee, Taek-Gi
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.49 no.3
    • /
    • pp.211-218
    • /
    • 2000
  • The performance and dynamic characteristics of three-phase active power filter with PCC voltage compensation is presented and analyzed in this paper. The characteristics of parallel active filter are discussed when they are applied to nonlinear loads with current source and voltage source type, the characteristics of voltage compensator and comparison of two functions are discussed. The proposed scheme in this paper employs a PWM voltage-source inverter and has two operation modes. First, it operates as a conventional active filter with reactive power compensation while PCC voltage is in a certain range. Second, is operates as a voltage compensator while PCC voltage is out of range. Finally, the validity of this scheme is investigated through analysis of simulation and experimental results for a prototype active power filter system rated at 10KVA.

  • PDF