• Title/Summary/Keyword: operation Modes

Search Result 815, Processing Time 0.035 seconds

Grid-Tied and Stand-Alone Operation of Distributed Generation Modules Aggregated by Cascaded Boost Converters

  • Noroozian, Reza;Gharehpetian, Gevorg;Abedi, Mehrdad;Mahmoodi, Mishel
    • Journal of Power Electronics
    • /
    • v.10 no.1
    • /
    • pp.97-105
    • /
    • 2010
  • This paper presents the modeling, control and simulation of an interconnection system (ICS) of cascaded distributed generation (DG) modules for both grid-tied and stand-alone operations. The overall configuration of the interconnection system is given. The interconnection system consists of a cascaded DC/DC boost converters and a DC/AC inverter. Detailed modeling of the interconnection system incorporating a cascaded architecture has not been considered in previous research. In this paper, suitable control systems for the cascaded architecture of power electronic converters in an interconnection system have been studied and modeled in detail. A novel control system for DC/DC boost converters is presented based on a droop voltage controller. Also, a novel control strategy for DC/AC inverters based on the average large signal model to control the aggregated DG modules under both grid-tied and stand-alone modes is demonstrated. Simulation results indicate the effectiveness of the proposed control systems.

A BLMS Adaptive Receiver for Direct-Sequence Code Division Multiple Access Systems

  • Hamouda Walaa;McLane Peter J.
    • Journal of Communications and Networks
    • /
    • v.7 no.3
    • /
    • pp.243-247
    • /
    • 2005
  • We propose an efficient block least-mean-square (BLMS) adaptive algorithm, in conjunction with error control coding, for direct-sequence code division multiple access (DS-CDMA) systems. The proposed adaptive receiver incorporates decision feedback detection and channel encoding in order to improve the performance of the standard LMS algorithm in convolutionally coded systems. The BLMS algorithm involves two modes of operation: (i) The training mode where an uncoded training sequence is used for initial filter tap-weights adaptation, and (ii) the decision-directed where the filter weights are adapted, using the BLMS algorithm, after decoding/encoding operation. It is shown that the proposed adaptive receiver structure is able to compensate for the signal-to­noise ratio (SNR) loss incurred due to the switching from uncoded training mode to coded decision-directed mode. Our results show that by using the proposed adaptive receiver (with decision feed­back block adaptation) one can achieve a much better performance than both the coded LMS with no decision feedback employed. The convergence behavior of the proposed BLMS receiver is simulated and compared to the standard LMS with and without channel coding. We also examine the steady-state bit-error rate (BER) performance of the proposed adaptive BLMS and standard LMS, both with convolutional coding, where we show that the former is more superior than the latter especially at large SNRs ($SNR\;\geq\;9\;dB$).

Nitrogen Removal in Livestock Wastewater Using Sequencing Batch Reactor (SBR을 이용한 축산폐수의 질소 제거)

  • Shin, Hang-Sik;Kim, Ku-Yong;Lee, Sang-Hyung;Lim, Jae-Lim
    • Journal of the Korean GEO-environmental Society
    • /
    • v.4 no.3
    • /
    • pp.61-67
    • /
    • 2003
  • A new precess which consists of pre-dewatering device, post composting for solid phase and post sequencing batch reactor(SBR) for liquid phase was designed. Nitrogen in supernatants of dewatering device was removed by sequencing batch reactor. Experiments were carried out to investigate the SBR operation modes such as fill ratio, SRT, and operation cycle. The optimum fill ratio, SRT and aeration/non-aeration time were 1/12, 15days, and 2hr aeration / 1hr non aeraion, respectively. Methanol as an external carbon source increased denitrification when step feeding method was applied, not single feeding method.

  • PDF

A Study on the Optimization of Power Consumption Pattern using Building Smart Microgrid Test-Bed (Building Smart Microgrid Test-Bed를 이용한 전력사용량 패턴 최적화방안 연구)

  • Lee, Sang-Woo;Kang, Jin-Kyu;Lee, Dong-Ha
    • Journal of the Korean Solar Energy Society
    • /
    • v.34 no.4
    • /
    • pp.1-7
    • /
    • 2014
  • The microgrid system is the combination of photovoltaic(PV) array, load, and battery energy storage system. The control strategies were defined as multi-modes of operation, including rest operation without use of battery, power charging, and power discharging, which enables grid connected mode or islanded mode. Photovoltaic power is a problem of the uniformity of power quality because the power generated from solar light is very sensitive to variation of insolation and duration of sunshine. As a solution to the above problem, energy storage system(ESS) is considered generally. There fore, in this study, we did basic research activities about optimization method of the amount of energy used, using a smart microgrid test-bed constructed in building. First, we analyzed the daily, monthly and period energy pattern amount of power energy used, and analyzed PV power generation level which is built on the roof. Utilizing building energy pattern analysis data, we was studied an efficient method of employing the ESS about building power consumption pattern and PV generation.

Analysis of Applicability in the Public Transportation System considering the Cost-volume Supply Curve of New Transit System Bi-Modal Tram (녹색 신교통 시스템 바이모달트램의 비용-수요 공급곡선을 고려한 도시 대중교통체계 적용 특성 분석)

  • Kim, Hong-Seok;Kim, Ryang-Gyun;Ham, Jae-Hyun;Jeon, Jae-Cheong;Yoon, Hee-Taek
    • Proceedings of the KSR Conference
    • /
    • 2010.06a
    • /
    • pp.2303-2308
    • /
    • 2010
  • We studied the cost-volume supply characteristic of public transportation systems focused on Bi-modal Tram in the main cities to analyze the applicability and status for the new transit system Bi-modal Tram as public transportation system. The operation cost considering the characteristic of vehicle, facilities, operation and average cost for respective public transportation system and the time cost considering the travel and transfer time are defined to the social cost, and the cost-volume supply curve is based on this social cost. The cost-volume supply characteristic between public transportation modes in the city is determined on the basis of cost-volume supply curve. Through the comparison between cost-volume supply characteristic of main transportation systems, it is analyzed about the relation between public transportation systems in the city and the characteristic for proper service provision. The application of Bi-modal Tram in the city is concluded that it is effective to reduce the social cost on the existing public transportation system.

  • PDF

The Performance Analysis of Integrated Navigation System Based on the Tactical Communication and VISION for the Accurate Localization of Unmanned Robot (무인로봇 정밀위치추정을 위한 전술통신 및 영상 기반의 통합항법 성능 분석)

  • Choi, Ji-Hoon;Park, Yong-Woon;Song, Jae-Bok;Kweon, In-So
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.14 no.2
    • /
    • pp.271-280
    • /
    • 2011
  • This paper presents a navigation system based on the tactical communication and vision system in outdoor environments which is applied to unmanned robot for perimeter surveillance operations. GPS errors of robot are compensated by the reference station of C2(command and control) vehicle and WiBro(Wireless Broadband) is used for the communication between two systems. In the outdoor environments, GPS signals can be easily blocked due to trees and buildings. In this environments, however, vision system is very efficient because there are many features. With the feature MAP around the operation environments, the robot can estimate the position by the image matching and pose estimation. In the navigation system, thus, operation modes is switched by navigation manager according to some environment conditions. The experimental results show that the unmanned robot can estimate the position very accurately in outdoor environment.

Power Control of a Hoist System Using Supercapacitor (수퍼캐패시터를 이용한 권상부하 시스템의 전력 제어)

  • Kim, Sang-Min;Yoo, Hyun-Jae;Sul, Seung-Ki
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.54 no.11
    • /
    • pp.561-568
    • /
    • 2005
  • This paper proposes a method that distributes the load power and stores the regenerated energy for a hoist-load system using the supercapacitor, an energy storage device. The crane, which is a representative hoist-load system, operates in two modes. The first is the hoist-up mode in which the load container is lifted up: the maximum power is required at the end of acceleration. The second is the hoist-down mode in which the load container is lifted down; the regenerated energy is wasted by the resistor In this paper, the supercapacitor stores the regenerated energy in the hoist-down operation and supplies the peak power demand in the hoist-up operation. The same structure as the commercially available three-phase inverter is proposed as a bidirectional do-dc converter to charge and discharge the supercapacitor. A power control algorithm is proposed to optimize the load sharing between the generator and the supercapacitor. Using the proposed method, it is effected that the generator size can be cut down to one third of the original one; it leads to the reduction of the fuel consumption, noise and air pollution. Simulation and experimental results verify the effectiveness of the Proposed method.

Heuristic Algorithm for Performance Improvement of Non-Communication Inverter Type Refrigerator (휴리스틱 기법을 이용한 비통신 인버터형 냉장시스템의 성능개선 알고리즘 개발)

  • Min, Seon Gyu;Kim, Hyung Jun;Lee, Ju Kyoung;Hwang, Jun Hyeon;Lee, Suk
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.34 no.2
    • /
    • pp.133-138
    • /
    • 2017
  • Inverter-Type refrigerators are known to consume less energy by varying the inverter frequency according to indoor temperatures and refrigerant pressure through indoor-outdoor communication. However, many commercial operators cannot afford to replace indoor units with ones capable of communication. In a non-communication configuration, indoor units are connected with an inverter-type outdoor unit without intercommunication abilities. The research goal is finding appropriate operating parameters to achieve energy efficiency. Thus, an operation algorithm with two modes is proposed, i.e., one to search the best operating parameters and one for normal operation with the best parameters. The experimental evaluation showed 11.27% reduction in energy consumption, indicating a good applicability of the algorithm.

Pulmonary Resection of Hemoptysis Patients -29 case- (각혈 환자의 폐절제술 -29례 보고-)

  • 박병률
    • Journal of Chest Surgery
    • /
    • v.28 no.12
    • /
    • pp.1139-1143
    • /
    • 1995
  • We experienced 29 cases of patients with a chief complaint of hemoptysis who were performed pulmonary resection at the Department of Thoracic and Cardiovascular Surgery, Pusan Medical Center Hospital for 3 years from May 1990 to April 1993. The mean age of hemoptysis patients was 34.7 year old, and hemoptysis was most prevalent in third and fourth decades. The underlying lung diseases of hemoptysis patients were tuberculosis in 12[41.4% , bronchiectasis in 9[31.0% , lung cancer in 4[13.8% , aspergyllosis in 3[10.3% and pneumonia in 1[3.5% . Modes of hemoptysis were blood tinged in 7[24.1% , massive in 22[75.9% . Operation times were elective in 7[24.1% of all blood tinged hemoptysis, delayed in 20[69.0% , emergency in 2[6.9% out of massive hemoptysis. The cases of the definite bleeding focus found by bronchoscopy were 19 cases[65.5% . The operative procedures of hemoptysis were single lobectomy in 14[48.3% , pneumonectomy in 6[20.7% , lobectomy with segmentectomy in 5[17.2% , bilobectomy in 3[10.3% and segmentectomy in 1[3.5% . The postoperative results of hemoptysis were complete recovery in 27[93.0% , rehemoptysis in 1[3.5% which was treated by anti-Tbc medication completely, and hospital death in 1[3.5% which was brain metastasis of lung cancer. It was concluded that definitive diagnosis, preoperative control of hemoptysis and operation were important in the management of hemoptysis patients.

  • PDF

Electrical characteristics of lateral poly0silicon field emission triode using LOCOS process

  • Lee, Jae-Hoon;Lee, Myoung-Bok;Park, Dong-Il;Ham, Sung-Ho;Lee, Jong-Hyun;Lee, Jung-Hee
    • Journal of Korean Vacuum Science & Technology
    • /
    • v.3 no.1
    • /
    • pp.38-42
    • /
    • 1999
  • Using the LOCOS process, we have fabricated the lateral type polysilicon field emission triodes with poly-Si/oxide/Si structure and investigated their current-voltage characteristics for three biasing modes of operation. The fabricated devices exhibit excellent electrical performances such as a relatively low turn-on anode voltage of 14 V at VGC = 0V, a stable and high emission current of 92${\mu}$A/triode over 90 hours, a small gate leakage current of 0.23 ${\mu}$A/triode and an outstanding transconductance of 57${\mu}$S/5triodes at VGC = 5V and VAC = 26V. these superior electrical operation is believed to be due to a large field enhancement effect, which is related to the sharp cathode tips produced by the LOCOS process as well as the high aspect ratio (height /radius ) of the cathode tip end.

  • PDF