• 제목/요약/키워드: operating unit

검색결과 1,251건 처리시간 0.029초

수술부 리모델링을 통한 공간구성 변화에 관한 연구 (A Study on the Area Composition of the Operating Unit After Remodeling)

  • 김길채
    • 의료ㆍ복지 건축 : 한국의료복지건축학회 논문집
    • /
    • 제29권4호
    • /
    • pp.57-67
    • /
    • 2023
  • Purpose: Recently, the operating unit remodeling compititon has been increasing rapidly in Korea, but there are no design infomation for spatial planning of sterile supply storage. Therefore, the propose of this study is to present area composition of the operating unit after remodeling. Methods: For literature review, the 6 studies and guidelines of operating unit(guidelines in the U.S, Australia, UK and Korea and 2 studies in Korea) conducted surveys and analysis. Room and space composition and zone of operating unit are redefined for this study. For obtaining area, to conduct masuring and calcuating of document of operating unit before and after remodeling in 3 cases. There are some patterns of plan in operaing unit by sterile supply storage. This study derived data for attributes of area composition of sterile supply storage. Results: The results of this study are as follows: First, Reviewing previous studies and Guidelines, for this study the suggested model was 5 zones(Operating zone, Support zone, Patient zone, Staff zone, Circulation zone) and redefined each room and space. Second, For infection control, sterile supply storage was provided to directly accessible to the operating room. Third, According to ralation of operting room and sterile supply storage, there are two types : 'double loaded type' and 'single loded type'. Sterile supply storage shall increase area of ciculation zone. Implications: This study can be used as primary data on remodeling of operating unit. In addition, it suggests that for infect control sterile supply storage is functional area.

종합병원 하이브리드수술유니트의 공간구성에 관한 연구 (1) (A Study on the Space Composition of Hybrid Operating Unit in General Hospital (1))

  • 김병수;채철균
    • 의료ㆍ복지 건축 : 한국의료복지건축학회 논문집
    • /
    • 제30권2호
    • /
    • pp.23-34
    • /
    • 2024
  • Purpose: The Hybrid care environment, combining interventional procedures and surgeries in one space, is crucial for managing complex diseases, responding to emergencies, and reducing recovery times and pain. This study provides foundational data for creating architectural guidelines for a Hybrid Operating Unit in a general hospital's surgical department, focusing on cardiovascular care. Methods: The study analyzed the spatial and configuration types of the Vascular Angiography Unit and the Cardiac Operating Unit, which are the basic components of the Hybrid Operating Unit, through a literature review. Based on the initial research findings, interviews with experts were conducted. Results: In the Hybrid Operating Process, the study proposed spatial configuration alternatives that consider the positioning of medical staff and the types and arrangement changes of equipment, including Angiography, Heart-lung machines, and other surgical tools and instruments. Implications: The integration of the two units leads to increased diversity and demand for medical staff, equipment, and supplies during surgical and interventional procedures. Therefore, strategic spatial configurations and equipment placement are necessary to effectively respond to these needs.

Study of combinations of site operating states for multi-unit PSA

  • Yoo, Heejong;Jin, Kyungho;Heo, Gyunyoung
    • Nuclear Engineering and Technology
    • /
    • 제53권10호
    • /
    • pp.3247-3255
    • /
    • 2021
  • As Probabilistic Safety Assessments (PSAs) are thoroughly conducted for the Site Operating States (SOSs) for a single unit, multi-unit Probabilistic Safety Assessments (MUPSAs) are ongoing worldwide to address new technical challenges or issues. In South Korea, the determination of the site operating states for a single site requires a logical approach with reasonable assumptions due to the fact that there are 4-8 operating units for each site. This paper suggests a simulation model that gives a reasonable expectation of the site operation states using the Monte-Carlo method as a stochastic approach and deterministic aspects such as operational policies. Statistical hypothesis tests were conducted so that the reliance of the simulation results can be guaranteed. In this study, 7 units of the Kori site were analysed as a case study. The result shows that the fraction of full power for all 7 units is nearly 0.45. For situations when more than two units are not in operation, the highest fraction combination was obtained for Plant Operation State (POS) 8, which is the stage of inspection and repairment. By entering various site operation scenarios, the simulation model can be used for the analysis of other site operation states.

EA 담당조직의 역할과 EA 활용역량이 EA 성과에 미치는 영향에 관한 실증적 연구 (An Empirical Study on the Effects of the Role of EA Operating Unit and EA Utilization Capability on the EA Performance)

  • 박일규;김상훈;서일정
    • 한국IT서비스학회지
    • /
    • 제9권1호
    • /
    • pp.27-42
    • /
    • 2010
  • Recently, many organizations are actively adopting Enterprise Architecture (EA) as a methodology to manage IT assets and build IT-based business system. However, most existing studies on EA have focused on the adoption stage of EA. Now the research concerning effective management and utilization of EA after adopting EA is keenly required. This study intended to empirically examine how the role of EA operating unit and the EA utilization capability of organizational members impact on EA performance at the post-adoption stage of EA. Based on Resource Based View (RBV), this study proposed the model and the hypotheses describing that the impact of the role of EA operating unit on EA performance is mediated by the EA utilization capability of organizational members. In order to test the hypotheses, the field survey whose respondents were seventy four Korean public agencies which have adopted EA was conducted by means of questionnaire. Data analysis was done with partial least square (PLS), which is a structural equation modeling (SEM) technique that uses a component-based approach to estimation. The results of the empirical analyses showed that the organizational operation ability of EA operating unit significantly influenced EA performance via the EA utilization capability of organizational members, but that EA education and training performed by EA operating unit did not. The results of this study provided a lot of theoretical and practical implications regarding EA management activities at the post-adoption stage of EA to enhance EA performance.

수술유니트의 유형 및 규모 산정을 위한 건축계획 프로그램에 관한 연구 (A study on the Architectural Planning Program for the type and scale computation of Operating-Unit)

  • 채철균
    • 의료ㆍ복지 건축 : 한국의료복지건축학회 논문집
    • /
    • 제8권2호
    • /
    • pp.43-50
    • /
    • 2002
  • By reason of development of anesthesia, advent of new surgical operation type and change of hygiene criterion and economical index is increasing recently request about alteration of existing unit or new surgical operation-unit type. The purpose of this study is to provide of architectural planning program for the type decision and the scale computation of operating-unit in healthcare facilities. As a result of this study, presented program of six type according to surgical operation process including space and time side.

  • PDF

매립가스 자원화를 위한 가스엔진 발전의 수익성에 관한 연구 (A Study on Profitability of Power Plant for Landfill Gas)

  • 김오우;이정일
    • 산학경영연구
    • /
    • 제19권2호
    • /
    • pp.69-94
    • /
    • 2006
  • 매립된 패기물의 분해과정에서 생성되는 부산물로서의 매립가스는 악취와 환경오염을 유발하는 유해한 가스로 여겨져 왔다. 그러나 발열량이 $5,000kcal/m^3$에 달하는 매립가스의 특성은 에너지원으로써의 활용가치가 탁월한데다 지구온난화의 주범으로 떠오르면서 그 회수 필요성이 더욱 강조되고 있어, 재생에너지로서의 매립가스를 대체에너지 자원으로 이용하려는 추세는 매우 고무적인 현상이라 하겠다. 현재 우리나라의 매립가스자원화 사업은 가스엔진을 이용한 전력생산이 대부분을 차지하고 있으며, 부분적으로 중질가스와 고질가스의 활용에도 관심을 보이고 있다. 가스발전기의 가동률과 전력단가의 변동을 고려하여 매립가스의 경제성을 분석해본 결과, 초기 투자비 회수와 지속적인 수익성 확보를 위해서는 최소한 10년 이상의 발전사업 운영 및 전력판매 단가의 현실화가 요구되고 있다.

  • PDF

Investigation on the Reduction Effect on Cooling Power Consumption and Operating Cost of Mist-spray Outdoor Units in Air Conditioner

  • Lee, Keon-ho;Cho, Dong-woo;Kim, Hyemi;Song, Young-hak
    • Architectural research
    • /
    • 제19권4호
    • /
    • pp.101-108
    • /
    • 2017
  • The use of the air conditioner is increasing due to the rise of the outdoor temperature during summer, and the problems of the fire and the cooling performance deterioration are caused due to lack of maintenance of the outdoor unit. In particular, overall performance of cooling system and efficiency in outdoor units have been degraded due to an intake of high-temperature outdoor air thereby increasing cooling energy and operating cost. Thus, this study aimed to increase efficiency of outdoor units by evaporating and cooling intake air through mist spray at the intake port surface in the outdoor unit. The measurements results showed that total power consumption of misting outdoor unit compared to that of conventional outdoor units was reduced by 21% approximately, and total power consumption of the entire system including pump was reduced by 16.7%. In addition, the operating cost including water use was reduced by 13.5% approximately. In summary, if a mist-spray nozzle kit is installed in air-cooled outdoor units, the reduction in the usage of cooling energy and operating cost will be achieved without replacement of existing cooling systems or a large scale of repairs.

인버터 스크롤 압축기를 사용한 멀티 에어컨의 냉방 특성에 대한 실험적 연구 (Experimental Study on Cooling Characteristics of Multi - Air Conditioner using Inverter Scroll Compressor)

  • 권영철;고국원;진의선;허삼행;전용호;이영덕;박인규
    • 설비공학논문집
    • /
    • 제16권4호
    • /
    • pp.311-317
    • /
    • 2004
  • In the present study, the cooling characteristics of the multi-air conditioner (A/C) using an inverter scroll compressor are experimentally investigated for the number of the indoor units and the operating conditions (2$0^{\circ}C$, 24$^{\circ}C$, 26$^{\circ}C$) under the cooling standard conditions by KS C 9306. In the case of the simultaneous operation for 3 indoor units, the cooling capacity, the mass flow rate and the input power have a decreasing trend and COP has an increasing trend, with decreasing the difference in the operating temperature of the indoor unit and the room temperature. In the case of the simultaneous operation for 2 indoor units, the COP of the indoor unit with large cooling capacity is high when the operating temperature is high, but the COP of the indoor unit with low cooling capacity is high when the operating temperature is low. In the case of the single operation for one unit, when the large cooling capacity of the indoor unit is less than 50% the compressor operates at the minimum operation frequency region and the COP decreases.

시간별 신뢰도 가치를 고려한 분산전원의 최적 운영전략 (Optimal Operating Strategy of Distributed Generation Considering Hourly Reliability Worth)

  • 배인수;신동준;김진오
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제52권8호
    • /
    • pp.457-462
    • /
    • 2003
  • This paper presents an optimal operating strategy of distributed generation (DG) with reliability worth evaluation of distribution systems. Using DG for peak-shaving unit could reduce the overall system operating cost, and using DG for standby power unit could reduce the customer interruption cost. If DG operating cost is less than utility power cost in peak time, DG should be running to reduce the overall system operating cost. When customer interruption cost enlarges, however, standby power strategy may be the better operating strategy than peak-shaving strategy. Selection of whether DG should be operated for peak-shaving or for standby power, needs the accurate reliability worth evaluation and the accurate power cost evaluation. Instead of using annual average reliability worth, the concept of hourly reliability worth is introduced in this paper to determine the optimal operating decision of DG. Applying suggested hourly reliability worth, the distribution companies that possess DG could set up the optimal operating strategy of DG.

상용 초정밀 관성항법시스템용 윈도우즈 운영체제 기반 CDU(Control Display Unit) 설계 (A Windows Operating System based Control Display Unit for a Commercial High Precision Inertial Navigation System)

  • 김정원;신대식;황동환;이상정;박용운
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 학술대회 논문집 정보 및 제어부문
    • /
    • pp.101-103
    • /
    • 2005
  • This paper designs a CDU(Control Disaply Unit) for commercial high precision INS(Inertial Navigation System). The CDU is designed using GUI(Graphic User Interface) programming running on Windows operating system. Since the designed CDU provides standard functions of the Windows operating systems and has a modular structure, it is easy to modify and extend. The CDU has been interfaced to the H-726 INS, from which it's usefulness can be seen.

  • PDF