• Title/Summary/Keyword: operating time

Search Result 5,688, Processing Time 0.031 seconds

A Group Maintenance Model with Extended Operating Horizon (연장된 운용기간을 활용하는 그룹보전모형)

  • Yoo, Young-Kwan
    • Journal of the Korea Safety Management & Science
    • /
    • v.19 no.3
    • /
    • pp.89-95
    • /
    • 2017
  • This paper presents another maintenance policy for a group of units under finite operating horizon. A group of identical units are subject to random failures. Group maintenances are performed to all units together at specified intervals, and the failed units during operation are remained idle until the next group maintenance set-up. Unlike the traditional assumption of infinite operating horizon, we adopt the assumption of the finite operating horizon which reflect the rapid industrial advance and short life cycle of modern times. The units are under operation until the end of the operating horizon. Further, the operation of units are extended to the first group maintenance time after the end of the horizon. The total cost under the proposed maintenance policy is derived. The optimal group maintenance interval and the expected number of group maintenances during the horizon are found. It is shown that the proposed policy is better than the classical group maintenance policy in terms of total cost over the operating horizon. Numerical examples are presented for illustrations.

The Degumming and Sericin Recovery of the Silk fabric Using the Electrolytic Water(II) (전해수를 이용한 견섬유 정련 및 세리신 회수(II)-분리막에 의한 세리신 농축을 중심으로-)

  • 배기서;이태상;노덕길;홍영기
    • Textile Coloration and Finishing
    • /
    • v.16 no.4
    • /
    • pp.10-18
    • /
    • 2004
  • In this work, Aqueous sericin solution was prepared by degumming process with electrolytic reduction water. Then, the microfiltration and ultrafiltration systems were applied to the concentration of aqueous sericin solution. The objective of this study was to select the optimum operating condition among the different pressure. The permeate flux and rejection ratio were observed with time, pressure, flow rate and concentration. and, the wastewater and permeated water quality values such as pH, BOD, COD, and NH levels were measured. In order to see the influence of electrolytic reduction water, the flux of pure water and electrolytic reduction water by PVDF22(MF) and PS100(UF) membrane was measured. In microfiltration system, the relative flux reduction decreased rapidly to 0.02 in the 30min, as the concentration polarization and gel layer formation were increased. and then the sericin concentration rejection ratio was 40%. In ultrafiltration system, the permeate flux decreased with time and concentration, and increased with the operating pressure and flow rate. Optimal condition in PS100 membrane system for sericin concentration was operating pressure 1.464kgf/$cm^24, operating flow rate $7\ell/min at\; 40^{\circ}C$. At that time, sericin concentration rejection ratio was 83% respectably. The sericin solution was concentrated from 0.1wt% solution to 0.2 wt % solution during about 2 hrs by the UF filteration membrane system.

The Implementation of a Media Player on Q+ Real-time Operating System (Q+ 실시간 운영체제에서 동작하는 미디어 재생기의 구현)

  • Cho, Chang-Sik;Mah, Pyeong-Soo
    • The Transactions of the Korea Information Processing Society
    • /
    • v.7 no.11
    • /
    • pp.3509-3518
    • /
    • 2000
  • Due to a recent advance on the internet access technologies such as ADSL and ISDN, ti becomes possible to watch movies or listen to music at home through the internet. In this paper, we propose Implementation technique and expenence we lcarnet in the development of media plavers operating on Q+ reall-time operating system. The media player can manipulate MPS, MPEG-1, and MPEG-4 streams, and the decofing routime is implemented by software. Ths medial player is operated on the digital TV set-top-box and is implomented by using Q+ librares. In this paper, we focus on programming technique on q+ real-time operating system and performance enhancement technique.

  • PDF

The Development of an Operating System for Load-following Real-time Transformer Loss Minimization and Economic Analyses on its' Test Operation (부하 추종형 실시간 변압기 손실감소운전시스템 개발과 시범운영 경제성 분석)

  • Lee, Ok-Bae;Ahn, Jae-Kyoung
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.61 no.6
    • /
    • pp.797-803
    • /
    • 2012
  • In this paper, for minimizing the real-time operating load losses of the power transformer, a SCADA optimum operating system was developed, and the economic analyses on the test operation were performed. Transformer loss DB which reflects the economic integration operation criteria was constructed by referring the transformer manufacturer's loss data(iron loss, copper loss). Based on the loss DB, each substation transformer real-time loss was calculated according to the size of the transformer loads, and if integration or separation transformer operating conditions minimizing the loss are met, then a window pops-up and the dispatcher performs the substation equipments operation according to the procedure provided by this system. With the existing SCADA main program, the relation database of the substation facilities and integration/separation operation algorithm were developed and applied to Auto MTR Processor and pconn Processor Task module. Seven stations test data for seven months were analyzed for the economic analyses, and the results showed that Cost-Benefit ratio was 2.64, and IRR(Internal Rate of Return), 36%, which asserted the economic justification of the proposed system.

Evaluation of Autoligation Technique for Castration in Small Breed Dogs

  • Kim, Jong-In;Jeong, Soon-Wuk
    • Journal of Veterinary Clinics
    • /
    • v.37 no.2
    • /
    • pp.75-81
    • /
    • 2020
  • The objective of the present study was to evaluate the effectiveness of autoligation techniques for castrating healthy male small breed dogs. Forty dogs were divided into four groups, with 10 in each group, based on maturity and the surgical technique used: 1) immature dogs aged less than 1 year, with autoligation of the spermatic cord via a scrotal approach (SAL) as the surgical technique (SAL-IM); 2) mature dogs aged 1 year or older, with the same SAL surgical technique (SAL-M); 3) immature dogs aged less than 1 year, with double ligation of the spermatic cord with an absorbable suture via a prescrotal approach (PDL) as the surgical technique (PDL-IM); and 4) mature dogs aged 1 year or older, with the same PDL surgical technique (PDL-M). The effectiveness of the surgical technique was evaluated by comparing the operating time and complications between these four groups. The significant decreases in operating times were found in SAL-IM and SAL-M compared with those of PDL-IM and PDL-M (p < 0.01 and p < 0.01). Regardless of maturity, the SAL surgical technique reduced operating time by approximately 69.5% compared with the PDL surgical technique. When the complication severities were scored, the results showed no significant differences among the four group. The autoligation technique for castration in healthy male small breed dogs is considered to be effective because the operating time consuming is less than conventional techniques.

API Implementation for Internet Appliances (정보가전기기에 적용되는 실시간 운용체제용 API 제안)

  • 신창민;김도형;박승민
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2002.11a
    • /
    • pp.920-923
    • /
    • 2002
  • As the new technologies, such as IEEE 1394, USB, Bluetooth, PLC are appeared, the embedded real time operating system which is satisfied the various technologies is needed. This paper proposed and implemented C standard library which is independently used in real time operating system and which supports an application development interface. The proposed C standard library is based on EL/IX, an Embedded Linux API based on POSIX, which is suitable for other embedded operating systems as well. And because the proposed C standard library has four level, it supports various Internet appliances, such as digital TV, settop box. The developed C library is tested at Qplus-P real time operating system which is developed at ETRI.

  • PDF

Elevated Temperature Design of KALIMER Reactor Internals Accounting for Creep and Stress-Rupture Effects

  • Koo, Gyeong-Hoi;Bong Yoo
    • Nuclear Engineering and Technology
    • /
    • v.32 no.6
    • /
    • pp.566-594
    • /
    • 2000
  • In most LMFBR(Liquid Metal Fast Breed Reactor) design, the operating temperature is very high and the time-dependent creep and stress-rupture effects become so important in reactor structural design. Therefore, unlike with conventional PWR, the normal operating conditions can be basically dominant design loading because the hold time at elevated temperature condition is so long and enough to result in severe total creep ratcheting strains during total service lifetime. In this paper, elevated temperature design of the conceptually designed baffle annulus regions of KALIMER(Korea Advanced Liquid MEtal Reactor) reactor internal strictures is carried out for normal operating conditions which have the operating temperature 53$0^{\circ}C$ and the total service lifetime of 30 years. For the elevated temperature design of reactor internal structures, the ASME Code Case N-201-4 is used. Using this code, the time-dependent stress limits, the accumulated total inelastic strain during service lifetime, and the creep-fatigue damages are evaluated with the calculation results by the elastic analysis under conservative assumptions. The application procedures of elevated temperature design of the reactor internal structures using ASME Code Case N-201-4 with the elastic analysis method are described step by step in detail. This paper will be useful guide for actual application of elevated temperature design of various reactor types accounting for creep and stress-rupture effects.

  • PDF

A Study on Chemical Cleaning of Electrolytic Facilities with Sea Water (해수전해설비의 화학세정 최적화 방안에 관한 연구)

  • 이한철;이창우;현성호
    • Journal of the Korean Society of Safety
    • /
    • v.14 no.4
    • /
    • pp.114-119
    • /
    • 1999
  • When NaOCl was generated and put into sea-water cooling machine in order to overcome the biological hindrances against sea-water cooling machine, it was converted into metallic ion, particularly Ca and Mg, as a hydrate in sea-water and is to stick to electrolyte as a side reaction. This phenomena make the distance between the electrolytes narrow to decrease the flow rate, which induces the local vortex flow which erodes the pole plate. Moreover, this increases the resistance of the electrolyte as well as voltage to decrease the electrolytic efficiency, which has curtailed a chlorine yield and caused a pole plate cut. We are able to overcome these problems by chemical cleaning and intend to extend the life-time of electrolyte and to increase output of the sea-water electrolysis facilities by studying optimal policy regarding chemical cleaning of electrolytic cell. Cleaning time of electrolytic facilities is determined when both increase in electrolytic efficiency and decrease in pole-plate voltage are 10%. At this time as operating current of electrolytic facilities is high, operating time is diminished. Whereas, parameter of end point determination according to cleaning is Mg ionic concentration in solution. When we use Cleaner as a 7wt% HCl, cleaning time is about 80min proper. We are able to maintain pole plate performance by protecting against pole plate cut by means of electrolytic by-product, improve operating rate of facilities, and cut down on maintenance expenditure after acidic cleaning.

  • PDF

Model Based Design and Validation of Control Systems using Real-time Operating System (실시간 운영체제를 적용한 제어시스템의 모델기반 설계 및 검증)

  • Youn, Jea-Myoung;Ma, Joo-Young;SunWoo, Myoung-Ho;Lee, Woo-Taik
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.16 no.2
    • /
    • pp.8-17
    • /
    • 2008
  • This paper presents the Matlab/Simulink-based software-in-the-loop simulation(SILS) environment which is the co-simulator for temporal and functional simulations of control systems. The temporal behavior of a control system is strongly dependent on the implemented software and hardware such as the real-time operating system, the target CPU, and the communication protocol. The proposed SILS abstracts the system with tasks, task executions, real-time schedulers, and real-time networks close to the implementation. Methods to realize these components in graphical block representations are investigated with Matlab/Simulink, which is most commonly used tool for designing and simulating control algorithms in control engineering. In order to achieve a seamless development from SILS to rapid control prototyping (RCP), the SILS block-set is designed to support automatic code generation without tool changes and block modifications.

EXCUTE REAL-TIME PROCESSING IN RTOS ON 8BIT MCU WITH TEMP AND HUMIDITY SENSOR

  • Kim, Ki-Su;Lee, Jong-Chan
    • Journal of the Korea Society of Computer and Information
    • /
    • v.24 no.11
    • /
    • pp.21-27
    • /
    • 2019
  • Recently, embedded systems have been introduced in various fields such as smart factories, industrial drones, and medical robots. Since sensor data collection and IoT functions for machine learning and big data processing are essential in embedded systems, it is essential to port the operating system that is suitable for the function requirements. However, in embedded systems, it is necessary to separate the hard real-time system, which must process within a fixed time according to service characteristics, and the flexible real-time system, which is more flexible in processing time. It is difficult to port the operating system to a low-performance embedded device such as 8BIT MCU to perform simultaneous real-time. When porting a real-time OS (RTOS) to a low-specification MCU and performing a number of tasks, the performance of the real-time and general processing greatly deteriorates, causing a problem of re-designing the hardware and software if a hard real-time system is required for an operating system ported to a low-performance MCU such as an 8BIT MCU. Research on the technology that can process real-time processing system requirements on RTOS (ported in low-performance MCU) is needed.