• 제목/요약/키워드: operating temperature measurement

검색결과 195건 처리시간 0.025초

경수로 사용후핵연료 건식저장시스템의 격납감시 기술현황 분석 (Status Analysis for the Confinement Monitoring Technology of PWR Spent Nuclear Fuel Dry Storage System)

  • 백창열;조천형
    • 방사성폐기물학회지
    • /
    • 제14권1호
    • /
    • pp.35-44
    • /
    • 2016
  • Leading national R&D project to design a PWR spent nuclear fuel interim dry storage system that has been under development since mid-2009, which consists of a dual purpose metal cask and concrete storage cask. To ensure the safe operation of dry storage systems in foreign countries, major confinement monitoring techniques currently consist of pressure and temperature measurement. In the case of a dual purpose metal cask, a pressure sensor is installed in the interspace of bolted double lid(primary and secondary lid) in order to measure pressure. A concrete storage cask is a canister based system made of double/redundant welded lid to ensure confinement integrity. For this reason, confinement monitoring method is real time temperature measurement by thermocouple placed in the air flow(air intake and exit) of the concrete structure(over pack and module). The use of various monitoring technologies and operating experiences for the interim dry storage system over the last decades in foreign countries were analyzed. On the basis of the analysis above, development of the confinement monitoring technology that can be used optimally in our system will be available in the near future.

Monitoring soil respiration using an automatic operating chamber in a Gwangneung temperate deciduous forest

  • Lee, Jae-Seok
    • Journal of Ecology and Environment
    • /
    • 제34권4호
    • /
    • pp.411-423
    • /
    • 2011
  • This study was conducted to quantify soil $CO_2$ efflux using the continuous measurement method and to examine the applicability of an automatic continuous measurement system in a Korean deciduous broad-leaved forest. Soil respiration rate (Rs) was assessed through continuous measurements during the 2004-2005 full growing seasons using an automatic opening/closing chamber system in sections of a Gwangneung temperate deciduous forest, Korea. The study site was an old-growth natural mixed deciduous forest approximately 80 years old. For each full growth season, the annual Rs, which had a gap that was filled with data using an exponential function derived from soil temperature (Ts) at 5-cm depth, and Rs values collected in each season were 2,738.1 g $CO_2$ $m^{-2}y^{-1}$ in 2004 and 3,355.1 g $CO_2$ $m^{-2}y^{-1}$ in 2005. However, the diurnal variation in Rs showed stronger correlations with Ts (r = 0.91, P < 0.001 in 2004, r = 0.87, P < 0.001 in 2005) and air temperature (Ta) (r = 0.84, P < 0.001 in 2004, r = 0.79, P < 0.001 in 2005) than with deep Ts during the spring season. However, the temperature functions derived from the Ts at various depths of 0, -2, -5, -10, and -20 cm revealed that the correlation coefficient decreased with increasing soil depth in the spring season, whereas it increased in the summer. Rs showed a weak correlation with precipitation (r = 0.25, P < 0.01) and soil water content (r = 0.28, P < 0.05). Additionally, the diurnal change in Rs revealed a higher correlation with Ta than that of Ts. The $Q_{10}$ values from spring to winter were calculated from each season's dataset and were 3.2, 1.5, 7.4, and 2.7 in 2004 and 6.0, 3.1, 3.0, and 2.6 in 2005; thus, showing high fluctuation within each season. The applicability of an automatic continuous system was demonstrated for collecting a high resolution soil $CO_2$ efflux dataset under various environmental conditions.

OXYGEN CONCENTRATION IN THE CATHODE CHANNEL OF PEM FUEL CELL USING GAS CHROMATOGRAPH

  • Ha, T.H.;Kim, H.S.;Min, K.D.
    • International Journal of Automotive Technology
    • /
    • 제8권1호
    • /
    • pp.119-126
    • /
    • 2007
  • Because of the low temperature operation, proton exchange membrane (PEM) fuel cell has a water phase transition. Therefore, water management is an important operation issue in a PEM fuel cell because the liquid water in the fuel cell causes electrode flooding that can lower the cell performance under high current density conditions. In this study, in order to understand the reactant distributions in the cathode channels of the PEM fuel cell, an experimental technique that can measure the species concentrations of reactant gases by using gas chromatograph (GC) is applied for an operating PEM fuel cell. The oxygen distribution along the cathode flow channels of PEM fuel cell is mainly investigated with various operating conditions. Also, the relations between cathode flooding and oxygen concentrations and oxygen consumption pattern along the cathode channel configurations of the unit cell adopted for this study are discussed using GC measurement and visualization experiment of cathode flooding. It is found that the amount of oxygen consumption is very sensitive to various operating conditions of the fuel cell and was much affected by the flooding occurrence in cathode channels.

지열원히트펌프를 활용한 도로융설시스템의 성능 평가 및 예측 (An Evaluation and Prediction of Performance of Road Snow-melting System Utilized by Ground Source Heat Pump)

  • 최덕인;황광일
    • 한국태양에너지학회 논문집
    • /
    • 제32권3호
    • /
    • pp.138-145
    • /
    • 2012
  • Because of the climate changes and the development of building technologies, the cooling loads have been increased. Among the various renewable energies, geothermal energy is known as very useful and stable energy for heating and cooling of building. This study proposes a road snow-melting system of which heat is supplied from GSHP(Ground source heat pump) in viewpoint of the initial investment and annual running performance, which is also operating as a main facility of heating and cooling for common spaces. The results of this study is as followings. From the site measurement, it is found out that the road surface temperature above the geothermal heating pipe rose up to $5^{\circ}C$, which is the design temperature of road snow-melting, after 2 hours' operation and average COP(Coefficient of performance) was estimated as 3.5. The reliability of CFD has confirmed, because the temperature difference between results of CFD analysis and site measurement is only ${\pm}0.4^{\circ}C$ and the trend of temperature variation is quite similar. CFD analysis on the effect of pavement materials clearly show that more than 2 hours is needed for snow-melting, if the road is paved by ascon or concrete. But the road paved by brick is not reached to $5^{\circ}C$ at all. To evaluate the feasibility of snow-melting system operated by a geothermal circulation which has not GSHP, the surface temperature of concrete-paved road rise up to $0^{\circ}C$ after 2 hour and 40 minutes, and it does never increase to $5^{\circ}C$. And the roads paved by ascon and brick is maintained as below $0^{\circ}C$ after 12 hours geothermal circulation.

Galvanic Corrosion between Carbon Steel 1018 and Alloy 600 in Crevice with Boric Acid Solution

  • Kim, Dong Jin;Macdonald, Digby D.;Kim, Hong Pyo;Kim, Joung Soo
    • Corrosion Science and Technology
    • /
    • 제4권3호
    • /
    • pp.75-80
    • /
    • 2005
  • This work dealt with the evaluation of galvanic corrosion rate in a corrosion cell having annular gap of 0.5 mm between carbon steel 1018 and alloy 600 as a function of temperature and boron concentration. Temperature and boron concentration were ranged from 110 to 300 $^{\circ}C$ and 2000~10000 ppm, respectively. After the operating temperature of the corrosion cell where the electrolyte was injected was attained at setting temperature, galvanic coupling was made and at the same time galvanic current was measured. The galvanic corrosion rate decreased with time, which was described by corrosion product such as protective film as well as boric acid deposit formed on the carbon steel with time. From the galvanic current obtained as a function of temperature and boron concentration, it was found that the galvanic corrosion rate decreased with temperaturewhilethe corrosionrate increasedwith boronconcentration. The experimental resultsobtained from galvanic corrosion measurement were explained by adhesive property of corrosion product such as protective film, boric acid deposit formed on the carbon steel wall and dehydration of boric acid to be slightlysolubleboric acid phase.Moreoverthe galvaniccorrosionrate calculatedusing initialgalvaniccoupling current instead of steady state coupling current was remarked, which could give us relatively closer galvanic corrosion rate to real pressurized water reactor.

엔진 캠/태핏 시스템의 토크 측정과 마찰$cdot$마멸 특성에 관한 연구 (Torque Measurement and Tribological Characteristics of the Cam/Tappet System in an I.C. Engine)

  • 여창동;김대은;윤정의
    • 한국윤활학회:학술대회논문집
    • /
    • 한국윤활학회 1997년도 제25회 춘계학술대회
    • /
    • pp.19-24
    • /
    • 1997
  • The operating torque and tribological characteristics of the cam/tappet system in an I.C. engine have an important effect on engine efficiency. In this paper, we measured the torque of cam/tappet system with respect to the oil temperature and camshaft speed to characterize the tribological behavior. Also, accelerated test was performed to analyze the wear characteristics of cam/tappet interface. The torque of the cam/tappet system decreased with respect to camshaft speed and was not significantly affected by the oil temperature. The results of accelerated test showed that the running-in wear occurred during the tests and the center of the tappet was mainly damaged by the rolling and sliding friction.

  • PDF

오일레스 복합계 베어링재의 최대허용 PV값 측정에 관한 실험적 고찰 (An Experimental Analysis on the Maximum Allowable PV Value of Oilless Composite Bearing Materials)

  • 공호성;윤의성;전기수;송광호
    • Tribology and Lubricants
    • /
    • 제11권1호
    • /
    • pp.27-36
    • /
    • 1995
  • Maximum allowable PV values of oilless composite bearing materials (70% epoxy-resin/30% Graphite) were measured and compared at various types of test rigs that have different contact geometry and the operating conditions. Test results showed that material failure was mainly characterized by the sharp increase in both coefficient of friction and surface temperature, and different PV values were measured under different Contact geometry. The discrepancy in measurement of PV values was analyzed in the light of theoretical frictional heating analysis. Results show that surface temperature rise depends on its contact geometry, and PV values could be overestimated in the testing conditions of high sliding velocity. Test data of different contact geometry were normalized by using a normalized contact pressure and sliding velocity; it showed a good correlation. This work suggests that normalized PV values could be more effective in evaluating bearing materials than conventional PV values for a design parameter of journal bearings.

자연형태양열 트롬월 축열벽 시스템의 열성능 특성 실측 분석 연구 (Experimental Study on the Thermal Performance of Passive Solar Trombe Wall System)

  • 윤종호;백남춘;신우철
    • 한국태양에너지학회 논문집
    • /
    • 제28권1호
    • /
    • pp.75-81
    • /
    • 2008
  • Thermal performance of passive solar Trombe wall system which is applied on the south wall of KIER Zero energy Solar House has been monitored for 6 months of heating season. Based upon the long-term measurement results, extensive statistical analysis was conducted to investigate temperature profiler and heat flow pattern in Trombe wall system under actual operating condition. Heat flow characteristics depending on the time variation of day and month was clearly revealed. Heat gain and loss on the inner surface of the Trombe wall was calculated base upon measured temperature data. Those results would be utilized to improve the efficiency of new type solar storage wall system.

겨울철 강설 관측을 위한 강수량계 가열 시스템 운영 조건 선정에 관한 연구 (The study on the selection of operating conditions of the precipitation heating system for observation of snowfall in winter)

  • 김병택;황성은;이영태;김민후;황현준;인소라;윤진아;김기훈
    • 한국수자원학회논문집
    • /
    • 제56권7호
    • /
    • pp.461-470
    • /
    • 2023
  • 본 연구는 겨울철 적설 관측에 사용되는 전도형 강수량계 가열 시스템의 최적 온도, 위치, 제어 방식을 도출하기 위해 수행하였다. 수수구, 외부, 내부를 가변적으로 제어 가능한 전도형 강수량계를 제작하여 실내·외 실험을 수행하였다. 실내 실험은 강수량계 가열시스템의 성능비교와 적정온도를 도출하기 위해 항온항습챔버에서 수행되었다. 이후 다설지인 대관령에 위치한 구름물리선도센터에서 실외실험을 수행하여 실내실험 결과를 검증하였다. 분석 결과, 수수구의 가열 온도는 10~30℃, 내부 가열 온도는 70℃가 최적으로 확인되었다. 또한, 측정 지연을 최소화하기 위한 가열 장치의 최적 위치는 강수량계 외부, 수수구 테두리, 수수구 수직면으로 확인되었다. 본 연구 결과는 겨울철 고체 강수 측정을 위한 강수량계 가열 시스템의 운영 조건에 대한 기초자료로 활용이 가능할 것으로 판단된다.

주.보기용 4행정 대형디젤엔진의 IMO운전모드에 따른 배기 배출특성 (The Emission Characteristics of a 4-stroke Large Diesel Engines for Propulsion and Generation Application in IMO modes)

  • 김현규;김규보;전충환;장영준
    • 대한기계학회논문집B
    • /
    • 제26권10호
    • /
    • pp.1472-1479
    • /
    • 2002
  • Environmental protection on the ocean has been interested and nowadays the International Maritime Organization(IMO) has advanced on the prevention of air pollution from ships. This study presents the emission characteristics of 4 stroke marine diesel engines in E3 cycle (propulsion application) and D2 cycle (generation application). Also the effects of important operating parameters in terms of intake air pressure and temperature, and maximum combustion pressure on the specific emissions are described. Emissions measurement and calculation are processed according to IMO Technical Code. The results show that NOx emission level in E3 cycle is higher than that in D2 cycle due to lower engine speed at low load and the maximum combustion pressure by fuel injection timing control and intake air temperature has strong influence on NOx emission production. And CO, HC emissions are not affected by maximum combustion pressure and intake air pressure and temperature.