• 제목/요약/키워드: operating temperature measurement

검색결과 195건 처리시간 0.028초

제과공장의 폐수처리장에서 발생하는 악취 저감 (Reduction of the Offensive Odor from Confectionery Wastewater Plant)

  • 김영식;손병현;조상원;정종현
    • 한국환경보건학회지
    • /
    • 제24권1호
    • /
    • pp.62-69
    • /
    • 1998
  • It has been studied that the measurement of odor component emission at confectionery manufacture. The objects of this study were to investigate reduction of offensive odor. The survey effects of odorous materials are presented as follows. The countermeasure of operating process is to minimize sludge sediment in each unit facility. Especially, in summer, we have to clean the sludge frequently, because anaerobic decomposing is likely to occur easily. The sludge or scum from sedimentation tank pond, and floating tank should be treated quickly. We should avoid overloading operation. In the case of overloading, dissolved oxygen should be increased, the quality of wastewater input should be decreased. When dried cakes from condense tank or floating tank are left in treatment plant, we should cover, to prevent diffusion of smell with masking materials. The seasonal condition of operating should be fixed and the kind of coagulants should be changed because the wastewater in each season have different loading rates and organic materials. Odorous materials are very sensitive to the seasonal temperature variation. Especially, when the amount of rainfall is small and the high temperature of maintenance in long periods, air diffusion rate is large, so odorous materials can make great effect on surroundings comparision with other periods. To reduce odorous gas, as short term method, we had better take ceramic addition method. Especially, in summer we should take ceramic addition method. Also, as long term method, the size of wastewater treatment facility is the most important in the normal operating of wastewater treatment facility. But wastewater treatment facilities in this factory are too old, treatment process is old fashion, and the size is too small. So, large wastewater quantity to treat in summer. As results, the expansion of wastewater treatment facility and the process of improvement are required. Restriction level of odor was exceed. As it is overloaded in summer, the basis cause of odor is that the size of wastewater treatment facility is small. The prediction of air quality equilibrium density variation show that the odorous materials from working place are Amine materials whose smell strength is about 2.5(a little strong degree). We can suppose that in summer is sensitive to temperature variation, smell strength is larger as to reduce the origin of odor. We must expand wastewater treatment facility and improve the process A.S.A.P.

  • PDF

DMMP 검출용 금속산화물을 첨가한 $SnO_2$ 가스센서 제조 (Fabrication of $SnO_2$ Gas Sensor added by Metal Oxide for DMMP)

  • 최낙진;반태현;곽준혁;백원우;김재창;허증수;이덕동
    • 한국군사과학기술학회지
    • /
    • 제6권3호
    • /
    • pp.54-61
    • /
    • 2003
  • $SnO_2$ gas sensor for the detection DMMP, simulant of nerve gas was fabricated and its characteristics were examined. Sensing materials were $SnO_2$ added by TEX>$\alpha$-$Al_{2}O_{3}$ with 0∼20wt.% and $In_{2}O_{3}$ with 0∼3wt.% and were physically mixed each material. They were deposited by screen printing method on alumina substrate. The sensor was consisted of sensing electrode with interdigit(IDT) type in front and a heater in back side. Its dimension was 7$\times$10$\times$0.6$\textrm{mm}^2$. Crystallite size 8t phase identification, specific surface area and morphology of fabricated $SnO_2$ powders were analyzed by X-ray diffraction(XRD), surface area analyzer(BET) and by a scanning electron microscope(SEM), respectively. Sensor was measured as flow type and sensor resistance change was monitored as real time using LabVIEW program. The best sensitivities were 75% at adding 4wt.% TEX>$\alpha$-$Al_{2}O_{3}$, operating temperature $300^{\circ}C$ and 87% at adding 2wt.% $In_{2}O_{3}$, operating temperature $350^{\circ}C$ to DMMP 0.5ppm. Response and recovery times were about 1 and 3 min., respectively. Repetition measurement was very good with $\pm$3% in full scale. As a result, operating temperature was lower TEX>$\alpha$-$Al_{2}O_{3}$ than $In_{2}O_{3}$, but sensitivity was higher $In_{2}O_{3}$ than $\alpha$-$Al_{2}O_{3}$.

Lifetime Assessment for Oil-Paper Insulation using Thermal and Electrical Multiple Degradation

  • Kim, Jeongtae;Kim, Woobin;Park, Hung-Sok;Kang, Ji-Won
    • Journal of Electrical Engineering and Technology
    • /
    • 제12권2호
    • /
    • pp.840-845
    • /
    • 2017
  • In this paper, in order to investigate the lifetime of oil-paper insulation, specimens were artificially aged with thermal and electrical multiple stresses. Accelerated ageing factors and equivalent operating years for each aging temperatures were derived from results of tensile strengths for the aged paper specimens. Also, the evaluation for the multi-stress aged specimens were carried out through the measurement of impulse breakdown voltage at high temperature of $85^{\circ}C$. The lifetimes of the oil-paper insulations were calculated with the value of 66.7 for 1.0 mm thickness specimens and 69.7 for 1.25 mm thickness specimens throughout the analysis of impulse BD voltages using equivalent operating years, which means that dielectric strengths would not be severely decreased until the mechanical lifetime limit. Therefore, for the lifetime evaluation of the oil-paper insulation, thermal aging would be considered as a dominant factor whereas electrical degradation would be less effective.

가변용량형 피스톤펌프의 파라미터 추정 (Estimation of Parameters in a Variable Displacement Piston Pump)

  • 허준영;리차드 버튼
    • 유공압시스템학회논문집
    • /
    • 제1권4호
    • /
    • pp.9-14
    • /
    • 2004
  • An estimation technique called the Extended Kalman filter is used to estimate viscous friction, spring initial contraction, and the spring constant on the swash plate of a variable displacement pump. The feasibility of the approach was established using a simulation study. It showed that these parameters could be estimated very accurately in a reliable and independent fashion. A special experimental system was set up to facilitate the measurement of certain states to enhance the Kalman Filtering approach. The aforementioned parameters were estimated and found to be reasonably repeatable for a common operating point. It was very evident that as the operating conditions changed (i.e. temperature) so did the estimated values of certain parameters such as viscous friction. This was believed to be a good verification test for the approach.

  • PDF

Reference Point Projection Method for Improved Dynamics of Solar Array Hardware Emulation

  • Wellawatta, Thusitha;Choi, Sung-Jin
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2018년도 전력전자학술대회
    • /
    • pp.126-128
    • /
    • 2018
  • Solar array simulator (SAS) is a special DC power supply that regulates the output voltage or current to emulate characteristics of photovoltaic (PV) panels. Especially, the control of SAS is a challenging task due to the nonlinearity in the output curve, which is dependent on irradiance as well as temperature and is determined by panel materials. Conventionally, both current-mode control and voltage-mode control should be alternated by partitioning the operating curve into multiple sections, which is not only for the measurement noise problem with the feedback sensing but also for the control stability issue near the maximum power point. However, the occurrence of transition among different controllers may deteriorate the overall performance. To eliminate the mode transitions, a novel single controller scheme has been introduced in this paper, where the reference operating projection technique enables simple, smooth and numerically stable control. Theoretical consideration on the loop stability issue is discussed and the performance is verified experimentally for the emulation of a PV panel data in view of stability and response speed.

  • PDF

가속열화시험에 의한 18kV ZnO 피뢰기의 누설 전류 특성 분석 (Leakage Current Characteristics of 18kv ZnO Lightning Arresters by Accelerated Aging Test)

  • 김주용;송일근;김찬영;문재덕
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제51권2호
    • /
    • pp.62-67
    • /
    • 2002
  • This paper provides the results of accelerated aging test of 18kV ZnO lightning arresters to investigate the leakage current characteristics. It was impossible to establish the replacement criterion for field operating lightning arrester because conventional aging test was only focused on the aging of ZnO elements. In general, it is possible to replace the aged arresters before the failure in the field using the leakage current measurement because it must be increased by the aging. But we can not use the method because we don't know the characteristics of the installed lightning arresters. Therefore in this paper we applied operating voltage and accelerating cycle which consists of temperature and humidity to the arresters. Then we measured the variation of total and resistive leakage current and found out the characteristics of the acted lightning arresters.

급수기구 발생음의 실험실 측정방법 제3부 : 직렬 밸브와 급수기구의 설치방법 및 작동조건 (Laboratory tests on noise emission from appliances and equipment used in water supply installations Part 3: Mounting and operating conditions for in-line valves and appliances)

  • 정갑철;양관섭;박현구;김선우
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2004년도 추계학술대회논문집
    • /
    • pp.986-989
    • /
    • 2004
  • The method of measurement for laboratory tests on noise emission from appliances and equipment used in water supply installations is specified in ISO 3822-1 This part of standard gives detailed descriptions for mounting and operating in-line valves and appliances, which control the flow, pressure or temperature of the water in water supply installations in such laboratory tests.

  • PDF

고속열차용 감속기 모니터링 시스템 개발 (Development of Condition Monitoring System for Reduction Unit of High-speed Rail)

  • 이동형;권석진;박병수;조덕영;김진우
    • 한국정밀공학회지
    • /
    • 제30권7호
    • /
    • pp.667-672
    • /
    • 2013
  • This paper presents the development of a condition monitoring system that monitors the operating conditions of a reduction unit, such as the bearing temperature, gearbox vibration, and gear oil deterioration, and notifies the operator of potential problems or abnormal conditions. A series of field tests on high-speed rail and conventional lines was performed to identify the characteristics of temperature rise and vibration levels on the reduction unit during operation. The monitoring system was designed based on the proper sensor selection, measurement method, and signal analysis to optimize the interface with the operating system of high-speed trains. Application of this monitoring system to high-speed trains will play an important role in their proper maintenance and safe operation.

노말프로판올과 아세틱에씨드 계의 최소자연발화온도(AIT) 측정 및 예측 (Measurement and Prediction of Autoignition Temperature(AIT) of n-Propanol and Acetic acid System)

  • 하동명
    • 한국안전학회지
    • /
    • 제32권2호
    • /
    • pp.66-71
    • /
    • 2017
  • The autoignition temperature (AIT) is crucial combustible characteristics which need attention in chemical process that handle hazardous materials. The AIT, also to as minimum spontaneous ignition temperature(MSIT), is the lowest temperature of a hot surface at which the substance will spontaneously ignite without any obvious sources of ignition such as a spark or flame. The AIT may be used as combustion property to specify operating, storage, and materials handling procedures for process safety. This study measured the AITs of n-propanol+acetic acid system from ignition delay time(time lag) by using ASTM E659 apparatus. The AITs of n-propanol and acetic acid which constituted binary system were $435^{\circ}C$ and $212^{\circ}C$, respectively. The experimental AITs of n-propanol+acetic acid system were a good agreement with the calculated AITs by the proposed equations with a few A.A.D.(average absolute deviation). In the case of n-propanol and acetic acid system, the minimum autoignition temperature behavior (MAITB), which is lower than the lower AIT, is shown among the two pure substances constituting the mixture.

신조 8,500GT 화학물 운반선의 여름철 선실 내 온열환경 실측평가 (A Measurement and Evaluation of the Indoor Thermal Conditions in Summer of a Newly-Launched 8,500GT Chemical Carrier)

  • 황광일;도근영;조효제;우상우;신동걸;임성택
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제32권5호
    • /
    • pp.717-723
    • /
    • 2008
  • The purpose of this study is to measure and analyze the indoor thermal conditions of a 8,500GT class chemical carrier which was launched on July 2007. The measurement was operated from 4th June to 4th June 2007, just before handing over to Owner. Followings are the results of this study. (1)The temperature variations of supply air were related to the outdoor temperature variations, but the humidity was stable at $65{\sim}80%$. (2)The temperature variations at the representative position of bridge, restaurant, crew's cabin showed gentle slopes. but that of conference room was very steepy. The humidities of bridge and restaurant were unstable because of outdoor-contact and cooking, respectively. (4)The temperature and humidity of ECR(Engine Control Room) which was designed to supply heating and cooling by PAC(Package Air Conditioner) were directly affected by the operating conditions of PAC. (5)The measured supply air volume from dampers of bridge, crew's cabin and conference room were satisfied with the design supply air volume. (5)For the improvement of the indoor thermal conditions, the temperature of crew's cabin and restaurant and the humidity of conference room, and the temperature and humidity of bridge should be controlled, respectively.