• 제목/요약/키워드: operating temperature

검색결과 3,662건 처리시간 0.027초

Effects of phosphorus content and operating temperature on the electrochemical performance of phosphorus-doped soft carbons

  • Kim, Eun Hee;Jung, Yongju
    • Carbon letters
    • /
    • 제15권4호
    • /
    • pp.277-281
    • /
    • 2014
  • A series of high capacity soft carbons with different phosphorus contents were successfully prepared by carbonizing petroleum cokes treated with hypophosphorous acid at $900^{\circ}C$. The effect of phosphorus content on the electrochemical performance of the soft carbons was extensively investigated. The P-doped soft carbons exhibited greatly enhanced discharge capacities and outstanding rate capabilities with increasing phosphorus content. In addition, the influence of temperature on the electrochemical behaviors of the soft carbons was investigated in a wide temperature range of $25^{\circ}C$ to $50^{\circ}C$. Surprisingly, the electrochemical properties of the pristine and P-doped soft carbons were highly sensitive to the operating temperature, unlike conventional graphite. The pristine and P-doped soft carbons exhibited significantly high discharge capacities of 470 and 522 mAh/g, respectively, at a high temperature of $50^{\circ}C$.

A Low Voltage Bandgap Current Reference with Low Dependence on Process, Power Supply, and Temperature

  • Cheon, Jimin
    • 한국정보기술학회 영문논문지
    • /
    • 제8권2호
    • /
    • pp.59-67
    • /
    • 2018
  • The minimum power supply voltage of a typical bandgap current reference (BGCR) is limited by operating temperature and input common mode range (ICMR) of a feedback amplifier. A new BGCR using a bandgap voltage generator (BGVG) is proposed to minimize the effect of temperature, supply voltage, and process variation. The BGVG is designed with proportional to absolute temperature (PTAT) characteristic, and a feedback amplifier is designed with weak-inversion transistors for low voltage operation. It is verified with a $0.18-{\mu}m$ CMOS process with five corners for MOS transistors and three corners for BJTs. The proposed circuit is superior to other reported current references under temperature variation from $-40^{\circ}C$ to $120^{\circ}C$ and power supply variation from 1.2 V to 1.8 V. The total power consumption is $126{\mu}W$ under the conditions that the power supply voltage is 1.2 V, the output current is $10{\mu}A$, and the operating temperature is $20^{\circ}C$.

미생물연료전지의 전기생산에 미치는 운전온도 및 전극간 거리의 영향 (Effects of Operating Temperature and Electrode Gap Distance on Electricity Generation in Microbial Fuel Cells)

  • 최영대;이명은;송영채;우정희;유규선;이채영;정재우
    • 유기물자원화
    • /
    • 제20권1호
    • /
    • pp.41-49
    • /
    • 2012
  • 이형반응기 미생물연료전지(MFC) 시스템의 전기생산에 미치는 운전온도 및 전극간 거리의 영향에 관한 실험실 규모 실험을 수행하였다. 외부저항이 $(100\;{\Omega})$인 조건에서 시스템의 평균온도가 $30^{\circ}C$에서 $34^{\circ}C$로 증가할 때 외부저항 양단의 전압은 약 1.4배 증가하였다. 운전온도의 증가는 MFC의 OCV(open circuit voltage)를 증가시키며, 전극간 거리가 감소하고 운전온도가 증가함에 의해 최대전력이 얻어지는 전류가 상승하는 것으로 나타났다. MFC 시스템의 운전온도 증가에 의해 모든 전극간 거리조건에서 최대전력밀도가 크게 증가하였다. 시스템의 평균온도가 $4^{\circ}C$로 증가할 때 5~10 cm의 전극간 거리에서 얻어지는 최대전력밀도는 1.9~2.4배 증가하였고 동일한 온도조건에서는 전극간 거리가 감소할수록 전력수율이 증가하였다. MFC의 전기생산에 미치는 운전온도와 전극간 거리의 영향은 시스템의 내부저항과 밀접하게 관련되어 있는 것으로 나타났다. 즉, MFC의 운전온도가 증가하고 전극간 거리가 감소함에 의해 시스템의 내부저항이 감소함으로써 전기생산이 증가하였다.

바이오가스 연료를 사용하는 소형 가스/증기터빈 복합 발전 시스템의 성능특성 해석 (Operating Characteristics Study of a Small Gas/Steam Turbine Combined System Using Biogas)

  • 강도원;신현동;김동섭;허광범;박정극
    • 한국유체기계학회 논문집
    • /
    • 제15권3호
    • /
    • pp.51-56
    • /
    • 2012
  • This study analyzed the influence of firing biogas on the performance and operation of a gas/steam turbine combined system. A reference gas/steam turbine combined system, designed with biogas fuel(57% volumetric methane) was set up and off-design simulation was made to investigate operating characteristics when a couple of operating schemes to mitigate turbine blade overheating were applied. Performance at base-load operation using each scheme was compared and part load operation using the variable inlet guide vane was analysed. Also, differences in operating characteristics and performance caused by changes in the methane content of biogas and ambient temperature were examined.

가변속 스크롤 압축기의 운전조건의 변화에 따른 성능 해석 (Performance Analysis on the Variable Speed Scroll Compressor with Operating Conditions)

  • 박홍희;박윤철;김용찬
    • 설비공학논문집
    • /
    • 제12권7호
    • /
    • pp.649-658
    • /
    • 2000
  • Thermodynamic modeling of low-pressure scroll compressor was developed by combining continuity and energy conservation equation. Suction gas heating was considered using energy balance inside the low pressure shell. Pressure, temperature and mass of refrigerant-22 as a function of orbiting angle were calculated by solving the governing equations using fourth order Rung-Kutta scheme. Motor efficiency was taken by experiments with a variation of frequency. The developed model was applied to the analysis of an inverter driven scroll compressor with a variation of frequency, pressure ratio and operating conditions. The model was verified with the experimental results at the same operating conditions. The developed model was adequate to predict performance of the inverter driven scroll compressor as a function of operating conditions. Calculated parameters from the model were discharge temperature, mass flow rate, power input, COP, and thermodynamic properties with respect to orbiting angle. To enhance the performance of a scroll compressor, it is essential to diminish leakage at low frequency level and improve the mechanical efficiency at high frequency level.

  • PDF

운전조건에 따른 고분자 직접메탄올 연료전지 성능 특성 (Performance Characterization of Polymer Electrolyte Membrane Direct Methanol Fuel Cell on the Various Operation Conditions)

  • 정두환;이창형;신동열
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1996년도 하계학술대회 논문집 C
    • /
    • pp.1409-1411
    • /
    • 1996
  • Direct Methanol Fuel Cell(DMFC) using Pt-Ru electrocatlayst and Nafion menbrane can provide high performance if operating conditions are well designed. In this study, operating temperature, pressure, and fuel flow rate were changed to obtain optimum operating conditions of DHFC single cell. Performance of DMFC were increased by the increase of operating temperature. The concentration of fuel methanol was 2.0M $CH_{3}OH$ and pressure difference of cathode and anode was 2 atm were showed maximum performance of DMFC single cell with showing the current density of 160 $mA/cm^2$ at 0.2V cell voltage.

  • PDF

뉴스초점 - 광유와 합성유의 에너지 소비량, 온도변화 등의 성능시험 비교 고찰 (Study for Synthetic Oil Performance Test Comparing with Mineral Gear oil in an Agitator Gear Box:Power consumption, Temperature, Oil & parts life for the Heavy load gear box in the Phosphoric Acid Plant)

  • 이재근
    • 기술사
    • /
    • 제45권6호
    • /
    • pp.28-32
    • /
    • 2012
  • Namhae chemical is one of the largest fertilizer manufacturing company in Korea which company has operating 4 unit agitator gear boxes and producing variety kinds of fertilizer production. The gearbox operating temperature of agitator is approximated in $55^{\circ}C{\sim}90^{\circ}C$ and required to keep operating continuous without stopping. The system required high performance oil and longer oil drain interval as limited workforce in maintenance team. It was lubricated by mineral gear oil of ISO VG 320 and also need to change to new oil frequently. Namhae Chemical would expect to keep stable operating condition without shut down and consider, lower cost of operation and equipment protection.

  • PDF

사이클론의 작동온도가 압력손실에 미치는 영향에 관한 연구 (A Study on Effects of Operating Temperatures of Cyclone on Pressure Drop)

  • 곽지영;송명준;이열
    • 한국추진공학회:학술대회논문집
    • /
    • 한국추진공학회 2012년도 제38회 춘계학술대회논문집
    • /
    • pp.515-519
    • /
    • 2012
  • Lapple 방식의 사이클론 내부유동 특성과 작동온도와의 연관성이 수치해석적으로 관찰되었다. 수치계산의 결과는 과거 실험적/수치해석적 연구결과와 좋은 일치를 보였다. 사이클론 작동온도의 상승으로 벽면전단응력과 접선방향속도가 감소되어 압력손실이 저감되는 것이 관찰되었으며, 아울러 다양한 작동온도 조건에서 수치해석의 결과와 이론적 예측모델들의 압력손실 결과가 비교 분석되었다.

  • PDF

분전함에서 이상발열 감지를 위한 광온도센서의 동작특성 분석 (Operating Characteristic Analysis of Optic Temperature Sensor for Overheat Detection in Panel Board)

  • 문현욱;김동우;길형준;김동욱;이기연;김향곤
    • 조명전기설비학회논문지
    • /
    • 제23권10호
    • /
    • pp.100-106
    • /
    • 2009
  • 본 논문에서는 전기설비의 전기적 접속부 또는 전기배선 등에서 발생하는 이상발열을 감지하는 방법에 대해 알아보고, 분전함에서의 발열상태를 실시간으로 모니터링하는 전력설비 진단시스템에 사용되고 있는 광온도센서에 대하여 동작특성을 실험, 분석하였다. 광온도센서의 동작특성 실험을 위한 열원으로는 Black Body와 Hot Plate를 사용하였으며 각각에서의 열원의 온도변화에 따른 광온도센서 출력전압값을 측정, 분석하였다. 그리고 분전함내 차단기 단자에서의 체결불량으로 인한 이상발열 감지 실험을 기존의 발열 감지방법인 열전대와 적외선 열화상장치를 이용하여 실시하였고, 광온도센서를 이용해 실시하여 결과를 비교 분석하였다. 실험결과, 광온도센서의 이상발열 감지능력이 유사함을 확인할 수 있었다. 이러한 분석 결과는 향후 RFID형 광온도센서를 이용한 전력설비 진단시스템의 현장 적용에 있어 기본 자료가 될 것으로 기대된다.

반류수처리를 위한 현장 pilot plant 생물막 아질산화 반응조에서 운전인자 평가 (Evaluation of Operating Parameters of Reject Water Treatment System with Pilot-scale Biofilm Nitritation Plant at Field Condition)

  • 한진희;권민;한종훈;윤주환;남해욱;고주형
    • 한국물환경학회지
    • /
    • 제23권5호
    • /
    • pp.636-641
    • /
    • 2007
  • A pilot-scale biofilm nitiritation reactor was operated with the reject water from a large wastewater treatment plant. The effects of various operating parameters including pH, temperature, dissolved oxygen, solids and organic concentrations were examined. A stable nitritation was achieved at operating pH range of 7.3 to 8.8 with an alkalinity addition. Higher operating temperature of $35{\pm}0.7^{\circ}C$ achieved more stable nitritation compared to $30{\pm}0.2^{\circ}C$. It has been noticed that nitrite accumulation maintained with DO, solids and organic concentrations range of 0.8 to 3.9 mg/L, 3,400 to 11,000 mg/L, and 86 to 572 mg/L, respectively. It seems that the accumulation of nitrite was caused by both the inhibition of $NO_2{^-}$ oxidizers due to free ammonia and the maintenance of the high operating temperature of $35^{\circ}C$ which promote to accumulate the $NH_4{^+}$ oxidizers in the reactor. According to microbial community analysis of fluorescence in situ hybridization and INT-Dehydrogenase measurements, more nitrifiers were presented in attached form compared to suspended growth.