• Title/Summary/Keyword: operating standard

Search Result 1,426, Processing Time 0.041 seconds

Creating of Standard Operating Procedures for Chronic Inhlation and Carcinogenicity Test (흡입노출에 의한 만성·발암성시험 표준작업지침서 작성 연구)

  • Rim, Kyung-Taek;Kim, Soo-Jin
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.24 no.4
    • /
    • pp.578-586
    • /
    • 2014
  • Objectives: There is a requirement to establish the standard operating procedures(SOPs) for chronic inhalation/carcinogenicity testing, so we would like to set them appropriately. Methods and Results: We established SOPs according to guidelines from international organizations such as OECD, the US EPA, and relevant institutions in advanced countries. We also benchmarked other contract research organizations(CROs) in Korea. Conclusions: We created appropriate SOPs for chronic inhalation/carcinogenicity testing.

The Estimation of Standard Child Care Service Cost in Family Childcare Centers (가정어린이집 표준보육비 산정 연구)

  • Kim, Hye Gum;Lim, Yang Mi;Jo, Hye Young
    • Korean Journal of Childcare and Education
    • /
    • v.9 no.5
    • /
    • pp.37-78
    • /
    • 2013
  • This study aimed to analyze the operating expenses and to estimate the standard child-care service cost in family childcare centers. The subjects were 442 family childcare centers in Korea and the data were analyzed with descriptive statistics by using SPSS 18.0 programs. The main results were as follows. Firstly, as the result of operating expenses analyses of family childcare centers, monthly average staff wages were 5,120,000 won and average general operating costs per month were 5,114,170 won. Therefore, monthly average operating costs of family childcare centers were totally 10,234,170 won. Secondly, the four standard child care service costs were calculated on the basis of the directors holding an additional teacher's position concurrently, whether the additional cooking staff were employed or not, and the type of lunch/snack materials.

API Implementation for Internet Appliances (정보가전기기에 적용되는 실시간 운용체제용 API 제안)

  • 신창민;김도형;박승민
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2002.11a
    • /
    • pp.920-923
    • /
    • 2002
  • As the new technologies, such as IEEE 1394, USB, Bluetooth, PLC are appeared, the embedded real time operating system which is satisfied the various technologies is needed. This paper proposed and implemented C standard library which is independently used in real time operating system and which supports an application development interface. The proposed C standard library is based on EL/IX, an Embedded Linux API based on POSIX, which is suitable for other embedded operating systems as well. And because the proposed C standard library has four level, it supports various Internet appliances, such as digital TV, settop box. The developed C library is tested at Qplus-P real time operating system which is developed at ETRI.

  • PDF

Design and Implementation of MOST Network Service over POSIX (차량용 MOST 네트워크를 위한 POSIX 기반의 Network Service 설계 및 구현)

  • Lee, Mu-Youl;Chung, Sung-Moon;Jin, Hyun-Wook
    • IEMEK Journal of Embedded Systems and Applications
    • /
    • v.5 no.1
    • /
    • pp.23-28
    • /
    • 2010
  • The automotive industry tries to provide infotainment systems to emerging automobiles. Since the infotainment systems require various peripheral devices and network connectivity, legacy operating systems such as Linux and Windows can be much preferred due to its plentiful device drivers and multimedia applications while the operating systems following OSEK standard are used for automotive electronic control units. Thus it is highly desired that the system software supporting infotainment applications can be portable over different legacy operating systems providing unified programming interfaces. The majority of legacy operating systems support POSIX interfaces for application development. MOST is an automotive network standard for infotainment systems. Network Service defines the protocol stacks for MOST control data, which is essential to implement infotainment applications over MOST. In this paper, we suggest a POSIX-based Network Service so that we can utilize legacy device drivers and applications for automotive infotainment systems. We measure the performance of the POSIX-based Network Service and show that its overhead is not significant.

A Method for Reliability Analysis of Process Facilities under Changing Operating Conditions (운전조건이 변화하는 공정설비의 신뢰도 분석기법)

  • Choi Soo Hyoung
    • Journal of the Korean Institute of Gas
    • /
    • v.7 no.4 s.21
    • /
    • pp.20-23
    • /
    • 2003
  • The analysis of reliabilities of process facilities often uses models based on the Weibull distribution. The parameters in these models are functions of operating conditions, and determined by experiments. Using these values, we calculate the reliability, mean time to failure, and standard deviation. The conventional method assumes that the operating condition is constant, and thus treats the model parameters as constants. In this paper, a reliability function is proposed which is applicable when the scale parameter is a function of time, and an analysis method based on this is also presented. A case study on a cooling fan resulted in a big difference from the conventional method to which the average operating conditions were applied. The proposed method is also applicable to other process facilities, and expected to effectively take into account the effects of changes in the operating conditions on the reliabilities of the facilities.

  • PDF

Incorporating Climate Change Scenarios into Water Resources Management (기후 변화를 고려한 수자원 관리 기법)

  • Kim, Yeong-O
    • Journal of Korea Water Resources Association
    • /
    • v.31 no.4
    • /
    • pp.407-413
    • /
    • 1998
  • This study reviewed the recent studies for the climate change impact on water resource systems and applied one of the techniques to a real reservoir system - the Skagit hydropower system in U.S.A. The technique assumed that the climate change results in ±5% change in monthly average and/or standard deviation of the observed inflows for the Skagit system. For each case of the altered average and standard deviation, an optimal operating policy was derived using s SDP(Stochastic Dynamic Programming) model and compared with the operating policy for the non-climate change case. The results showed that the oparating policy of the Skagit system is more sensitive to the change in the streamflow average than that in the streamflow standard deviation. The derived operating policies were also simulated using the synthetic streamflow scenarios and their average annual gains were compared as a performance index. To choose the best operating policy among the derived policies, a Bayesian decision strategy was also presented with an example. Keywords : climate change, reservoir operating policy, stochastic dynamic programming, Bayesian decision theory.

  • PDF

Analysis of IEC 61727 Photovoltaic (PV) systems Characteristics of the utility interface

  • Lee, Jeong Hyeon;Yoon, Yong Ho;Kim, Jae Moon
    • International Journal of Internet, Broadcasting and Communication
    • /
    • v.7 no.2
    • /
    • pp.90-95
    • /
    • 2015
  • This paper describes IEC 61727 standard of Photovoltaic (PV) systems -Characteristics of the utility interface. IEC 61727 standard tests include utility compatibility and personnel safety and equipment protection of PV inverter performance functions. Especially utility compatibility part includes test items of 1) voltage, current and frequency, 2) normal voltage operating range, 3) flicker, 4) DC injection, 5) normal frequency operating range, 6) harmonics and 7) waveform distortion, 8) power factor of PV inverter. Also personnel safety and equipment protection part includes test items 1)loss of utility voltage, 2)over/under voltage and frequency, 3)Islanding protection, 4)response to utility recovery, 5)earthing, 6)short circuit protection, 7)Isolation and switching of PV inverter. In this paper, each item of IEC 61727 standard test is studied and analyzed and finally full tested by PV inverter performance function.

A study on the design and construction of operating room (병원 수술실 설계 및 시공에 관한 연구)

  • Jung, Eul-Kyu;Oh, Jung-Keun
    • Journal of the Korea Institute of Building Construction
    • /
    • v.3 no.2
    • /
    • pp.103-110
    • /
    • 2003
  • In the early 1990's the clean room system was a new trend of the operating room. This is the concept using in seminconductor plants. That is what the space around the operating table so clean as it remove contaminations with circulation of interior air. These articles describe the standard of interior construction and drawing details.

STANDARD OPERATING PROCEDURES OF HARD TISSUES SUCH AS FEMORAL HEAD, ALLOGRAFTS OBTAINED FROM LIVING DONORS (생존 기증자로부터 채취된 경조직(대퇴골두 등)의 조직은행 술식)

  • Lee, Eun-Young;Kim, Kyung-Won;Um, In-Woong;Ryu, Ju-Youn
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.30 no.5
    • /
    • pp.406-413
    • /
    • 2004
  • Progress in medical science and cell biology has resulted in the transplantation of human cells and tissues from on human into another, facilitating reproduction and the restoration of form and function, as well as enhancing the quality of life. For more than 40 years, society has recognized the medical and humanitarian value of donation and transplanting organs and tissues. The standard operating procedures of hard tissues reflect the collective expertise and conscientious efforts of tissue bank professionals to provide a foundation for the guidance of tissue banking activities. Procurement of allograft tissues from surgical bone donors is a part of tissue banking. During the past decades the use of bone allografts has become widely accepted for the filling of skelectal defects in a variety of surgical procedures. In particular in the field of orthopaedic and oral and maxillofacial surgery the demand for allografts obtained from either living or post-mortem donors has increased. Hospital-based tissue banks mainly retrieve allografts from living donors undergoing primary total hip replacement for osteoarthritis or hemi arthroplasty for hip fractures and orthgnatic surgery such as angle reduction. Although bone banks have existed for many years, the elements of organized and maintaining a hospital bone bank have not been well documented. The experience with a tissue bank at Korea Tissue Bank(KTB) between 2001 and 2004 provides a model of procurement, storage, processing, sterilization and documentation associated with such a facility. The following report describes the standard operating procedures of hard tissues such as femoral head obtained from living donors.

Process Development of a Standard Operating Procedure (SOP) for the Manufacturing of Standardized Distribution Boards (규격화된 분전반 제작을 위한 표준작업절차(SOP)의 공정 개발)

  • Ko, Wan-Su;Lee, Byung-Seol;Choi, Chung-Seog
    • Journal of the Korean Society of Safety
    • /
    • v.33 no.5
    • /
    • pp.21-27
    • /
    • 2018
  • The purpose of this study is to develop a SOP (Standard Operating Procedure) for a distribution board that can monitor the leakage current of a load distribution line in real time. The developed distribution board was fabricated by applying IEC 61439-1. It consists of the distribution board and an alarm device. The work process for making the distribution board was compliant with the KEMC (Korea Electrical Manufacturers Cooperative) regulations. And the AC distribution board range is 1,000 V. In addition, the voltage in DC is less than 1500 V. The distribution board receives a 3-phases and 4-wires power supply system and can supply power to the load of a maximum of 32 single or three phase distribution circuits. Also, leakage current measured on the power distribution board was used by sensors installed. The SOP of the developed distribution board consists of the installation standards for the short circuit alarm device and sensor, the surge protection device, switches and indication lamps, and other devices. The operation procedure was prepared so that each manufacturing step of the distribution board must be confirmed by the persons in charge of preparation, production, quality control and approval before moving forward to the next step.