• Title/Summary/Keyword: operating performance

Search Result 6,475, Processing Time 0.037 seconds

Effects of environmental temperature on the performance of direct methanol fuel cell for vehicles (외부온도가 수송용 메탄올연료전지 성능에 미치는 영향)

  • Han, Chang-Hwa;Jung, Dae-Seung;Choi, Ji-Sun;Han, Sang-Hun;Lee, Joong-Hee
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2009.11a
    • /
    • pp.176-179
    • /
    • 2009
  • The performance of direct methanol fuel cells is affected by operating conditions such as, methanol feeding temperatures, methanol concentrations, and methanol flow rates during the operation in different environmental conditions. In this study, effects of the environmental temperature on performance of direct methanol fuel cells have been investigated in order to test a applicability of direct methanol fuel cell to the vehicle. The environmental temperature (ET) was varied from $-20^{\circ}C$ to $+30^{\circ}C$. The inside fuel cell temperature (CT) during test at various operating conditions was monitored and the performance of fuel cell was measured in the I-V polarization curve. With increasing the ET, the performance of the fuel cell was significantly improved and the CT also almost linearly increased. However, at below $0^{\circ}C$ ET, the DMFC showed very poor performance and needed to control CT or methanol feeding temperature (MFT), methanol flow rate(MFR) to obtain enough power of the vehicle.

  • PDF

Impacts of Financial Distress and ICT on Operating Performance and Efficiency: Empirical Evidence from Commercial Banks in India

  • RAWAL, Aashi;RASTOGI, Shailesh;SHARMA, Rahul;RASTOGI, Samaksh
    • The Journal of Asian Finance, Economics and Business
    • /
    • v.9 no.6
    • /
    • pp.105-114
    • /
    • 2022
  • With the help of this study, we aim to investigate the influence of Financial Distress (FD) and information and communication technology (ICT) on the operating performance and efficiency of banks in the Indian banking sector. FD can be defined as a position in which a company or individual is not in a condition to fulfill their promise of paying their obligations on time. The term "financial distress" refers to a situation in which a corporation or individual is unable to keep their promise of paying their debts on time. In this work, panel data analysis (PDA) was used to analyze data from 33 Indian banks over ten years (2010 to 2019). According to the findings, FD has a positive and significant impact on bank operational performance and efficiency. The current study will give the banking industry a better understanding of how a bank's performance can be negatively impacted by distressing conditions that render it inefficient and ineffective. Second, it will show investors how the level of distress can have a significant impact on bank performance in the market, finally resulting in the loss of money invested.

Operating Performance of Solenoid Valve and Nozzle Sets for Target Selectable Sprayers (이동형 국소 분무장치용 전자 밸브와 노즐 조합 작동특성)

  • Suh, S.R.;Kim, H.O.;Kim, Y.T.;Choi, Y.S.;Yoo, S.N.
    • Journal of Biosystems Engineering
    • /
    • v.31 no.1 s.114
    • /
    • pp.39-45
    • /
    • 2006
  • Fundamental informations on performance of sets of solenoid valve and nozzle were necessary to develop a target selectable spraying system. The experiments were performed for the sets of solenoid valves and flat spraying nozzles at 3 levels of the operating pressures, and the obtained results are as follows; Rise time of the system pressure to reach up to 90% of the operating pressure after the valve turned was affected by nozzle size and operating pressure. Maximum overshoot of the system pressure was about 170% not affected by the sets of valve and nozzle and operating pressure. The system pressure after its settle down within 5% of the set pressure showed good uniformity in any condition of the experiment as less as 2.3% of its coefficient of variation. Time requirement to lower the system pressure down to 50% after the valve power turned off was affected by valve and nozzle set and operating pressure.

Design of Vehicle Control Algorithm and Engine-generator Control for Drivability of Range-extended Electric Vehicle (주행거리 연장형 전기자동차의 차량제어 알고리즘 설계 및 운전성 확보를 위한 엔진 발전시스템 제어)

  • Park, Youngkug
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.24 no.6
    • /
    • pp.649-659
    • /
    • 2016
  • This paper describes control algorithm and control structure of vehicle control unit for range-extended electric vehicle equipped with engine-generator system, and specially presents methods which determine optimal operating points and decreases a vibration or a shock for operating the engine-generating system. The vehicle control algorithm is consisted of several parts which are sequence control, calculation of wheel demand torque, determination of operating points, and management of operating points and so vehicle controller has be made possible to efficiently manage calibration parameters. The control algorithm is evaluated by driving test modes, launching performance and operating engine-generator system and so on. In conclusion, this paper present methods for extending a mileage, improving a launching performance and reducing vibration or shock when the engine-generating system is starting or is stopping.

An Empirical Study of Financial Analyst's Forecasting Activities on the Firm's Operating Performances (기업실적에 대한 재무분석가의 예측활동에 관한 실증연구)

  • Kwak, Jae-Seok
    • The Korean Journal of Financial Management
    • /
    • v.20 no.1
    • /
    • pp.93-124
    • /
    • 2003
  • This paper studies the financial analyst's forecasting activities on the firm's operating performance during the period from 1999 to 2003. In this study, financial analyst's forecasting activities are focused on the sales, operating income and net income and financial analyst's forecasting accuracy, forecasting revising patterns and forecasting activities to the unexpected firm's operating performance are studied. Some empirical findings in this study are as follows. First, standard estimate error on the sales, operating income and net income are all significantly negative value and so financial analyst's forecast on the firm's operating performance are upwardly biased. Second, domestic financial analyst's forecasting activities is relatively more accuracy than foreign financial analyst's forecasting activities. Third, forecasting time is more close to the end of the operating performance announcement day, forecasting activities are more accuracy. Fourth, comparing with individual financial analyst's forecast, consensus forecast is more accuracy. Fifth, in the comparative forecasting activities study according to the prior firm's operating performance, financial analyst's forecasting revision activities are found to be upward or downward. Sixth, financial analysts overreact in the sales forecast and underreact in the operating income and net income forecast. Seventh, in the empirical analysis on the Easterwood-Nutt's test model(1999) which the firm's performance change are divided into the expected performance change and the unexpected performance change, it is found that financial analyst's forecasting activities on the firm's operating performance are systematically optimistic.

  • PDF

Performance Characteristics of a Liquid-Metal Heat Pipe for igh-temperature Solar Thermal Devices Depending on the Operating Conditions (고온 태양열기기용 액체금속 히트파이프의 작동조건에 따른 성능 특성)

  • Park, Cheol-Min;Lee, Jung-Ryun;Boo, Joon-Hong;Kang, Yong-Heack
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2009.06a
    • /
    • pp.247-250
    • /
    • 2009
  • Sodium heat pipe for high-temperature solar thermal application was manufactured and tested for transient and steady-state operations. Total length of the heat pipe was 650 mm and the outer diameter was 12.7 mm. Thermal performance was compared experimentally for two different cooling methods of the forced and the natural convection cooling in the heat pipe condenser. During the experiment, the maximum temperature was about 1300K, and different cooling methods were applied to the condenser region to charge the operating temperature. The effective thermal conductivity and the thermal resistance were investigated as a function of heat flux, heat transport length, and operating temperature.

  • PDF

A Study on Stability and Performance Characteristics in Aero - Valved Pulsating Combustion System (공기밸브형 맥동연소 시스템의 안정성 및 성능특성에 관한 연구)

  • 임광렬
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.17 no.4
    • /
    • pp.11-19
    • /
    • 1993
  • The experimental study was carried out to investigate the stability and the performance characteristics of the aero-valved pulsating combustion system with maximum operating capacity of 60KW. The effect of geometry of combustion system on the stable condition, the flammability limit, the total pressure oscillation amplitude, and the operating frequency can be identified, and the maximum turn-down-ratio is obtained up to 3.3. The total pressure oscillation amplitude can be controlled by tunning the length of the air inlet pipe. The empirical equation with which the operating frequency can be approximated is proposed and the discrepancy is within 5%. The volumetric efficiency is identified to be one of the important parameters determining the upper flammability limit and the maximum value of which is approximately 22%.

  • PDF

The Analysis of the Operating Characteristics In A 500W Portable Air Cooled Polymer Electrolyte Membrane Fuel Cell (PEMFC) (500W급 공냉식 고분자 연료전지 설계, 제작 및 운전 특성)

  • Son Yeong Jun;Yang Tae Hyeon;Park Gu Gon;Im Seong Dae;Yun Yeong Gi;Lee Won Yong;Kim Chang Su
    • 한국전기화학회:학술대회논문집
    • /
    • 2004.06a
    • /
    • pp.37-42
    • /
    • 2004
  • To maintain proper operating conditions is important to get optimal output power of a PEMFC stack. The air cooled fuel cell stack is widely used in sub kW PEMFC systems. A 500W air cooled PEMFC stack was experimentally investigated to evaluate the design performance and to get optimal operating conditions for the portable application. The relationship between the operating conditions and the performance was analyzed. The results can be used as design criteria for portable PEMFC under various conditions.

  • PDF

Study for Synthetic Oil Performance Test Comparing with Mineral Gear oil in an Agitator Gear Box:Power consumption, Temperature, Oil & parts life for the Heavy load gear box in the Phosphoric Acid Plant (뉴스초점 - 광유와 합성유의 에너지 소비량, 온도변화 등의 성능시험 비교 고찰)

  • Lee, Jae Keun
    • Journal of the Korean Professional Engineers Association
    • /
    • v.45 no.6
    • /
    • pp.28-32
    • /
    • 2012
  • Namhae chemical is one of the largest fertilizer manufacturing company in Korea which company has operating 4 unit agitator gear boxes and producing variety kinds of fertilizer production. The gearbox operating temperature of agitator is approximated in $55^{\circ}C{\sim}90^{\circ}C$ and required to keep operating continuous without stopping. The system required high performance oil and longer oil drain interval as limited workforce in maintenance team. It was lubricated by mineral gear oil of ISO VG 320 and also need to change to new oil frequently. Namhae Chemical would expect to keep stable operating condition without shut down and consider, lower cost of operation and equipment protection.

  • PDF

A Performance analysis of robot tele-operator using 3D Images (입체영상(立體映像)을 이용한 원격Robot 조작자의 수행도 분석)

  • Jo, Am;Jeon, Yong-Ung
    • Journal of the Ergonomics Society of Korea
    • /
    • v.18 no.3
    • /
    • pp.127-140
    • /
    • 1999
  • In order to apply three-dimensional images to industries, the possibility of realizing three-dimensional images should be ensured and when operating a task using three-dimensional images, the intention of the observer and the result of operation should be precisely related. The aim of this paper is to investigate the task performance of a human operator during operating a robot manipulator using three-dimensional and two-dimensional image displays. From the result of this research, it was found that the accuracy of robot operation in the case of using three-dimensional displays is much higher than in the case of using two-dimensional displays and the adapting time to the operating task using three-dimensional displays is shorter than that using two-dimensional displays. From such results, we concluded that the application of three-dimensional displays, which can closely reflect real environment, to industries is desirable.

  • PDF