• Title/Summary/Keyword: operating frequency

Search Result 2,845, Processing Time 0.028 seconds

The Analysis of a High Frequency Series Resonant DC-DC Converter (고주파 직렬공진형 DC-DC Converter의 특성 해석)

  • 이윤종;김철진
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.39 no.9
    • /
    • pp.934-943
    • /
    • 1990
  • There are no turn-on losses in the series Resonant Converter which operates above the resonance frequency, and the commutation stress on the switched component is low. For a given Series Resonant Converter with specified load resistance, the output voltage is a function of the operation frequency. This paper describes the static and dynamic characteristic analysis of the Series Resonant DC to DC Converter, which is operating above the resonant frequency, with frequency control. For the analysis method, state plane technique is adopted, and the circuit operation is defined from normalized switching frequency, Fsn. Under this condition, circuit performance is analyzed ideally. The validity of the proposed analysis is verified by comparing with experimental results, the stability of the converter is confirmed against small variations around the operating point by conventional frequency domain analysis, and the stress quantity added to switch component is shown.

  • PDF

Utility AC Frequency to High Frequency ACPower Conversion Circuit with Soft Switching PWM Strategy

  • Sugimura Hisayuki;Ahmed Nabil A.;Ahmed Tarek;Lee Hyun-Woo;Nakaoka Mutsuo
    • KIEE International Transaction on Electrical Machinery and Energy Conversion Systems
    • /
    • v.5B no.2
    • /
    • pp.181-188
    • /
    • 2005
  • In this paper, a DC smoothing filterless soft switching pulse modulated high frequency AC power conversion circuit connected to utility. frequency AC power source is proposed for consumer induction heating hot water producer, steamer and super heated steamer. The operating principle of DC link filterless utility frequency AC-high frequency AC (HF AC) power conversion circuit defined as high frequency cycloinverter is described, which can operate under a principle of ZVS/AVT and power regulation based on alternate asymmetrical PWM in synchronization with the utility frequency single phase AC positive or negative half wave voltage. The dual mode modulation control scheme based on high frequency PWM and commercial frequency AC voltage PDM for the proposed high frequency cycloinverter are discussed to enlarge its soft switching commutation operating range for wide HF AC power regulation. This high frequency cycloinverter is developed for high frequency IH Dual Packs Heater (DPH) type boiler used in consumer and industrial fluid pipeline systems. Based on the experiment and simulation results, this high frequency cycloinverter is proved to be suitable for the consumer use IH-DPH boiler and hot water producers. The cycloinverter power regulation and power conversion efficiency characteristics are evaluated and discussed.

A study on the optimum operation scheme with operating reserve power (운전예비력의 최적운용방식에 관한 연구)

  • 송길영
    • 전기의세계
    • /
    • v.28 no.5
    • /
    • pp.49-55
    • /
    • 1979
  • During severe emergencies which result in insufficient generation to meet load, an automatic load shedding method considering the spinning and operating reserve can establish the optimum system operation. This paper presents methods and results of a study on the optimum operating scheme with spinning and operating reserve power in case of outage of large generator units to prevent frequency decay and continue stable operation. This study covers following three parts 1) Analysis of spinning reserve characteristics 2) Determination of operating reserve requirements 3) Development of the optimum load shedding programs By this study the optimum system operating method was recommended for reliable operation of power system.

  • PDF

Frequency Characteristics of Fluctuating Velocity According to Flow Rates in a Tip Leakage Vortex and a Wake Flow in an Axial Flow Fan (축류 홴의 익단누설와류 및 후류에서 유량에 따른 변동속도의 주파수 특성)

  • Jang, Choon-Man;Kim, Kwang-Yong;Fukano, Tohru
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.28 no.2
    • /
    • pp.181-188
    • /
    • 2004
  • The frequency characteristics in an axial flow fan operating at a design and three off-design operating conditions have been investigated by measuring the velocity fluctuation of a tip leakage vortex and a wake flow. Two hot-wire probe sensors rotating with the fan rotor. a fixed and a moving ones, were introduced to obtain a cross-correlation coefficient between two sensors as well as the fluctuating velocity. The results show that the spectral peaks due to the fluctuating velocity near the rotor tip are mainly observed in the reverse flow region of higher flow rates than those in the peak pressure operating condition. However, no peak frequency presents near the rotor tip for near stall condition. Detailed wake flow just downstream of the rotor blade was also measured by the rotating hot-wire sensor. The peak frequency of a high velocity fluctuation due to Karman vortex shedding in the wake region is mainly observed at the higher flow rate condition than that in the design point.

Study of High-Power-Factor Single-Stage Electronic Ballast for fluorescent lamps (고역률 단일 전력단을 갖는 형광등용 전자식 안정기에 관한 연구)

  • Park, J.W.;Seo, C.S.;Ro, C.G.;Kim, D.H.;Lee, K.H.;Seo, J.W.
    • Proceedings of the KIEE Conference
    • /
    • 2001.07b
    • /
    • pp.1129-1131
    • /
    • 2001
  • A new low cost single stage high power factor electronic ballast for fluorescent lamps is presented in this paper. The proposed topology is based on integration of two-boost converter and LC type high frequency resonant converter. A ballast is obtained by simple construction, because full bridge rectifier diode is eliminated and simple control circuits is applied. Using two boost converter operating positive and negative half cycle respectively at line frequency (60Hz), operating in discontinuous conduction mode performs high power factor. The simulated and experimental results for 64W fluorescent lamps operating at 45kHz switching frequency and 110V line voltage have been obtained.

  • PDF

Design and Comparison of the Frequency Synthesizers for MB-OFDM UWB Systems (MB-OFDM UWB 시스템을 위한 주파수 합성기의 유형별 설계 및 비교)

  • Lee, J.K.;Cheong, T.H.;Park, J.T.;Yu, C.G.
    • Proceedings of the KIEE Conference
    • /
    • 2006.10c
    • /
    • pp.482-484
    • /
    • 2006
  • This paper describes fast-hopping frequency synthesizers for multi-band OFDM(MB-OFDM) ultra-wide band(UWB) systems. Three different structures in generating 3 center frequencies(3432MHz, 3960MHz, 4488MHz) are designed and compared. The first structure generates 3 center frequencies using only one PLL operating at 4224MHz. The second uses three PLLs operating at corresponding center frequencies. The third employes two PLLs operating at 3960MHz and 528MHz. Simulation results using a 0.18um RF CMOS process parameters show that the third structure exhibit the best characteristics. The band switching time of the proposed synthesizer is less than 1.3ns and the spur is less than -36dBc. The synthesizer consumes 22mA from a 1.8V supply.

  • PDF

An Improvement of Sensorless Driving Performance for Brushless DC Motor Using Variable PWM Switching Frequency (가변 PWM 스위칭 주파수를 이용한 브러시리스 직류전동기의 센서리스구동 특성개선)

  • Woo, Hyuk-J.;Song, Myung-H.;Park, Kyu-N.;Yeo, Hyeong-G.;Kim, Kyoung-M.
    • Proceedings of the KIEE Conference
    • /
    • 1999.07f
    • /
    • pp.2534-2536
    • /
    • 1999
  • This paper suggested a new sensorless driving strategy for brushless de motor which can improve the conventional degradation of highspeed operating performances, lowspeed operating performances and starting performances caused by applying general single pwm switching frequency. By varying PWM switching frequency during operating time, the proposed method can get some desired upper performances. For confirming the validity of the proposed method, the sensorless driving system is implemented with an rPM module and 87c196MC micro controller.

  • PDF

Self-Oscillating Switching Technique for Current Source Parallel Resonant Induction Heating Systems

  • Namadmalan, Alireza;Moghani, Javad Shokrollahi
    • Journal of Power Electronics
    • /
    • v.12 no.6
    • /
    • pp.851-858
    • /
    • 2012
  • This paper presents resonant inverter tuning for current source parallel resonant induction heating systems based on a new self oscillating switching technique. The phase error is suppressed in a wide range of operating frequencies in comparison with Phase Locked Loop (PLL) techniques. The proposed switching method has the capability of tuning under fast changes in the resonant frequency. According to this switching method, a multi-frequency induction heating (IH) system is proposed by using a single inverter. In comparison with multi-level inverter based IH systems, the advantages of this technique are its simple structure, better transients and wide range of operating frequencies. A laboratory prototype was built with an operating frequency of 35 kHz to 55 kHz and 300 W of output power. The performance of the IH system shows the validity of the new switching technique.

Study of Single-Stage High-Power-Factor Electronic Ballast for fluorescent lamps operating in critical conduction mode (임계모드에서 동작하는 단일 전력단을 갖는 고역률 형광등용 전자식 안정기에 관한 연구)

  • Seo, C.S.;Kim, D.H.;Byun, Y.B.;Lee, P.S.;Sim, K.Y.;Oh, S.H.
    • Proceedings of the KIEE Conference
    • /
    • 2001.07b
    • /
    • pp.1126-1128
    • /
    • 2001
  • A single-stage high-power-factor electron ic ballast operating in critical conduction mode is presented in this paper. The proposed topology is based on integration of a boost-like converter and a LCC Type half-bridge serial resonant inverter. The power-factor-correction(PFC) stage is a boost-like converter operating in critical conduction mode for positive and negative half cycle voltage respectively at line frequency (60Hz) so that a high power factor is achieved naturally. The simulated and experimental results for 100w fluorescent lamps operating at 42kHz switching frequency and 220V line voltage have been obtained.

  • PDF

A Study on the Principal Factors for the Stirling Refrigerator Performance (일체형 스터링 냉동기 성능에 미치는 주요 인자에 관한 연구)

  • Kim, D.W.;Park, S.J.;Hong, Y.J.;Kim, H.B.;Ko, S.C.
    • Progress in Superconductivity and Cryogenics
    • /
    • v.10 no.1
    • /
    • pp.67-70
    • /
    • 2008
  • Performance of integral type Stirling refrigerator used for cooling infrared detector is affected by principal factors such as design factors and operating factors. Operating factors include charging pressure and operating frequency. The purpose of this paper is to examine the basic design analysis on the integral type Stirling refrigerator and the changes in performance through experiments on operating factors.