• 제목/요약/키워드: operating frequency

검색결과 2,845건 처리시간 0.025초

Fault Detection of Governor Systems Using Discrete Wavelet Transform Analysis

  • Kim, Sung-Shin;Bae, Hyeon;Lee, Jae-Hyun
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제36권5호
    • /
    • pp.662-673
    • /
    • 2012
  • This study introduces a condition diagnosis technique for a turbine governor system. The governor system is an important control system to handle turbine speed in a nuclear power plant. The turbine governor system includes turbine valves and stop valves which have their own functions in the system. Because a turbine governor system is operated by high oil pressure, it is very difficult to maintain under stable operating conditions. Turbine valves supply oil pressure to the governor system for proper operation. Using the pressure variation of turbine and governor valves, operating conditions of the turbine governor control system are detected and identified. To achieve automatic detection of valve status, time-based and frequency-based analysis is employed. In this study, a new approach, wavelet decomposition, was used to extract specific features from the pressure signals of the governor and stop valves. The extracted features, which represent the operating conditions of the turbine governor system, include important information to control and diagnose the valves. After extracting the specific features, decision rules were used to classify the valve conditions. The rules were generated by a decision tree algorithm (a typical simple method for data-based rule generation). The results given by the wavelet-based analysis were compared to detection results using time- and frequency-based approaches. Compared with the several related studies, the wavelet transform-based analysis, the proposed in this study has the advantage of easier application without auxiliary features.

비동기 방식의 직렬통신 시스템에서 헤드 검출 기능을 가진 회전기용 리시버의 FPGA 구현 (A FPGA Implementation of a Rotary Machine Receiver with Detecting a Header on the Asynchronous Serial Communication System)

  • 강봉순;이창훈;김인규;하주영;김주현
    • 한국정보통신학회논문지
    • /
    • 제9권1호
    • /
    • pp.88-94
    • /
    • 2005
  • 본 논문에서는 회전기의 위치에 대한 정보를 가지고 있는 Encoder와 정해진 경로(Serial Signal)를 통해 Data를 전송하거나 받고, DSP로 Data를 정해진 경로(Paralle Signal)를 통해 Data를 전송하거나 받는 기능을 가진 Receiver를 FPGA Design한 것이다. 동일 동작 Clock을 사용하지 않는 다른 System의 Serial Data 통신을 하는 경우, 새로운 헤더 검출 방법을 제시하여 Serial Data의 유효한 각 Bit의 정보를 얻기 위해서는 헤더 내의 Sync. Code를 해석하여 유효 Data의 길이를 찾을 수 있다. 또한 Receiver의 동작 주파수를 'clk_select' Port를 사용하여 내부 동작 주파수를 20MHz 또는 60MHz를 선택할 수 있다.

풍력-디젤-BESS 독립형 마이크로그리드 모델링 및 운전제어 알고리즘에 관한 연구 (Modeling & Operating Algorithm of Islanding Microgrid with Wind Turbine, Diesel Generator and BESS)

  • 김재언
    • 한국산학기술학회논문지
    • /
    • 제15권9호
    • /
    • pp.5893-5898
    • /
    • 2014
  • 본 논문은 연료비를 최소화 할 수 있는 2차전지 전력저장장치(BESS: Battery Energy Storage System)와 풍력-디젤 복합발전시스템으로 구성되는 독립형 마이크로그리드을 모델링하는 방법과 그 운전제어 알고리즘을 제안하였다. 먼저, 부하변동 및 풍속변동에 따른 주파수와 전압을 일정하게 제어할 수 있는 양방향 DC/AC 컨버터의 BESS를 모델링하고, 디젤발전기는 공급전력의 부족 및 BESS의 충전시에만 가동하도록 하는 운전제어알고리즘을 제안한다. 그리고, 제안된 모델링 방법과 운전제어알고리즘을 독립형 마이크로그리드에 적용한 결과, 풍속 및 부하변화에 대하여 주파수와 전압변동이 적정범위내로 유지할 수 있음을 증명할 수 있었다.

공기밸브형 맥동연소기의 동적 특성에 관한 실험적 연구 (An experimental study on the dynamic behavior in an aero-valved pulsating combustor)

  • 임광열;최병륜;오상헌
    • 대한기계학회논문집
    • /
    • 제11권5호
    • /
    • pp.846-855
    • /
    • 1987
  • 본 연구에서는 실용적 설계및 이론해석에 필요한 동적 거동에 관한 현상규명 및 기초자료를 제공하기위해, 기하학적 형상변화에 따른 맥동연소의 안정성 및 흡입공 기량의 측정을 통한당량비의 범위를 관찰하고, 연소실과 배기관, 공기유입관, 연료노 즐실에서의 압력을 각각 동시측정해서 동적거동에 관해 고찰하고, 작동주파수에 관한 간단한 실험식의 확립과 추력성능에 관한 실험을 행했다.

Modeling of 18-Pulse STATCOM for Power System Applications

  • Singh, Bhim;Saha, R.
    • Journal of Power Electronics
    • /
    • 제7권2호
    • /
    • pp.146-158
    • /
    • 2007
  • A multi-pulse GTO based voltage source converter (VSC) topology together with a fundamental frequency switching mode of gate control is a mature technology being widely used in static synchronous compensators (STATCOMs). The present practice in utility/industry is to employ a high number of pulses in the STATCOM, preferably a 48-pulse along with matching components of magnetics for dynamic reactive power compensation, voltage regulation, etc. in electrical networks. With an increase in the pulse order, need of power electronic devices and inter-facing magnetic apparatus increases multi-fold to achieve a desired operating performance. In this paper, a competitive topology with a fewer number of devices and reduced magnetics is evolved to develop an 18-pulse, 2-level $\pm$ 100MVAR STATCOM in which a GTO-VSC device is operated at fundamental frequency switching gate control. The inter-facing magnetics topology is conceptualized in two stages and with this harmonics distortion in the network is minimized to permissible IEEE-519 standard limits. This compensator is modeled, designed and simulated by a SimPowerSystems tool box in MATLAB platform and is tested for voltage regulation and power factor correction in power systems. The operating characteristics corresponding to steady state and dynamic operating conditions show an acceptable performance.

소형 압축기를 이용한 관성관형 맥동관 냉동기의 성능 특성에 대한 실험적 연구 (An Experimental Study on Performance of the Inertance Pulse Tube Refrigerator using a Small Compressor)

  • 김홍성;정상권
    • 설비공학논문집
    • /
    • 제17권6호
    • /
    • pp.552-559
    • /
    • 2005
  • This paper describes an experimental study on the inertance pulse tube refrigerator using a small compressor. The purpose of this experimental study is to identify the performance of the inertance pulse tube refrigerator for various operating conditions and to obtain the optimum configuration. The dead volume effect is verified by two experimental apparatuses with different dead volumes between the compressor and the aftercooler. The refrigerator of the smaller dead volume shows better performance. The influence of operating frequency and charging pressure on the performance of the refrigerator is experimentally investigated. Reducing the regenerator mesh size improves the performance of the refrigerator. Finally, the inertance pulse tube refrigerator has maximum cooling capacity at the specific combination of the pulse tube length and the inertance tube length. The loss analysis is used to analyze and predict the optimum condition of the pulse tube refrigerator.

실내주차장의 실내공기질 농도특성 및 환기에 의한 저감효과 (The Effect of Ventilation and Concentration of Indoor Air Quality at Indoor Parking Lots)

  • 박정호
    • 한국산업보건학회지
    • /
    • 제20권4호
    • /
    • pp.241-247
    • /
    • 2010
  • Recently, indoor air quality (IAQ) has been one of the major concerns of people. Indoor parking lots are subject to be exposed to high concentrations of air pollutants emitted from vehicles. This study was performed to investigate indoor air quality (IAQ) at indoor parking lots. Sampling sites were selected 5 indoor parking lots. Target indoor air quality parameters include a number of criteria pollutants such PM$_{10}$, CO, CO$_2$, and HCHO. In addition, a variation of IAQ according to ventilation system operating was measured at C site (underground parking lot). In general, all pollutants were maintained below indoor air quality maintenance standards. The indoor air quality at indoor parking lots was affected by the availability of the ventilation facility and their operation frequency. At the underground parking lot (C site) with ventilation system, TVOC concentration according to ventilation system operating were found to be lower operating (488.2 ${\mu}g/m^3$) than non-operating (1,401.2 ${\mu}g/m^3$).

5상 5kW 표면부착형 영구자석 동기발전기 운전특성 (An Operating Characteristics of Surface Permanent Magnetic Synchronous Generator for 5-Phase 5kW)

  • 정형우;김민회;송현직;김동희
    • 조명전기설비학회논문지
    • /
    • 제27권6호
    • /
    • pp.9-16
    • /
    • 2013
  • This paper presents an operating characteristics of the 5-phase 5kW with developed the surface permanent magnetic synchronous generato (SPMSG) in order to make a study of a polyphase ac motors keeping hold of more advantages. There are shown a amplitude and waveform of the generated electromotive force, in FFT analysis of harmonics, within output voltages, and reviewing a experiment results in no-load test, resistive load, and inductive load using 5-phase induction motor by variable output frequency. The operating characteristics of the developed manufacturing generator include voltage regulation, efficiency, power factor, THD, and so on at rated load.

비선형 보상기와 외란관측기를 이용한 공기압 실리더의 위치제어 (Position Control of a Pneumatic Cylinder with a Nonlinear Compensator and a Disturbance Observer)

  • 장지성
    • 대한기계학회논문집A
    • /
    • 제26권9호
    • /
    • pp.1795-1805
    • /
    • 2002
  • A position controller which can achieve a specified dynamic performance irrespective of the different operating position of the pneumatic cylinder is proposed. The position controller developed in this paper is composed of a nonlinear compensator and a disturbance observer. The nonlinear compensator which feeds back position, velocity and acceleration is derived from the nonlinear dominating equations of the position control system to compensate for variation of dynamic characteristics of a pneumatic cylinder according to the change of the operating position. The disturbance observer including a simplified linear model is designed to reduce the effect of model discrepancy in the low frequency range which cannot be suppressed by the nonlinear compensator. The results of the experiments show that the position control performance maintains a designed performance regardless of the variations of an operating position of the pneumatic cylinder.

음향방출 계측에 의한 터빈 제어밸브 내부누설 평가연구 (Study on Evaluation of Internal Leak of Turbine Control Valve in Power Plant Using Acoustic Emission Signal Measurement)

  • 이상국
    • 동력기계공학회지
    • /
    • 제12권5호
    • /
    • pp.65-70
    • /
    • 2008
  • The purpose of this study is to verify availability of the acoustic emission in-situ monitoring method to the internal leak and operating conditions of the turbine major valves relating to safety for turbine operating and prevention of turbine trouble at nuclear power plants. In this study, acoustic emission tests are performed when the pressurized electro-hydraulic control oil flowed through turbine electro-hydraulic controller oil check valve and turbine power/trip fluid solenoid valve in the condition of actual turbine operating. The acoustic emission method was applied to the valves at the site, and the background noise was measured far the abnormal plant condition. To judge for the leak existence ell the object valves, voltage analysis and frequency analysis of acoustic signal emitted from infernal leak in the valve operating condition are performed. It was conformed that acoustic emission method could monitor for valve internal leak to high sensitivity.

  • PDF