The Korean government is currently expanding the business startup incubator support program and funds for new ventures with innovative technology in order to spread the second venture boom. However, despite the fact that entrepreneurial education and mentoring that entrepreneurs should have are important parts for the sustainable growth of the startup, some companies selected for government support programs are reluctant to participate in programs such as entrepreneurship education and mentoring for the sole purpose of funding commercialization. This research addressed the effects of entrepreneurial alertness with opportunity awareness as its medium and the small business mentoring service along with the number of times the mentoring has taken place, on the corporate performances. The results of empirical research are as follow: the first one is that scanning-search and evaluation-judgment can influence a company's performance (financial, non-financial) through opportunity recognition, with the exception of association-connection, which is a sub-factor of entrepreneurial alertness. Secondly, it was found to affect a company's financial and non-financial performance through opportunity recognition for financing mentoring, technical support mentoring, and management support mentoring. Thirdly, it was found that the number of mentoring also affects the financial and non-financial performance of a company through opportunity recognition. The implications of this study are that it should be revisited that program managers consider rooms that do not violate the startup founder's strategic decision-making opportunities when designing and operating the program as entrepreneurial alertness sub-factor association-connection does not affect corporate performance through opportunity recognition. This study also emphasizes the need for customized mentoring to meet the outcome goals of each startup, as it has been empirically clarified that the mentoring provided to the startup by the government's support is important. The contribution of this research is that entrepreneurial alertness and opportunity recognition that are treated as important components in research for entrepreneurship, and the factors of mentoring and mentoring frequency that are recognized as important elements in the practical aspect of startup business are clarified theoretically and empirically as an influential factor in corporate performance. And this study also provide a rationale for the startup business support agency supplying mentoring.
In a survey in which farmers were asked about their levels of satisfaction with agricultural machines, Japanese products scored higher than local products by 1.2, 1.3, and 1.4 times for tractors, combine harvesters, and rice transplanter, respectively. Japanese products corresponded to generally high satisfaction levels in terms of operating performance, operability, frequency of breakdowns, and durability, excluding sales price and after-sales services. Effective countermeasures through quality improvement are therefore necessary for Korean products. Furthermore, a survey of dealers showed that the components and consumables for core agricultural machines had high frequencies of breakdowns and repairs. Four major components of tractors represented 85.3% of all breakdowns and repairs, five components of combine harvesters represented 89.6%, and three components of rice transplanters represented 80.5%. Moreover, a comparison of the technological levels between local and imported machines showed that the local machines' levels were at 60-100% for tractors, 70-100% for combine harvesters, and 70-95% for rice transplanters. Small and mid-sized tractors, 4 interrow combine harvesters, and 6 interrow rice transplanters showed similar levels of technology. The results of the analysis suggest that action is urgently needed at a policy level to establish an agricultural machinery component research center for the development, production, and supply of commonly-used components, with the participation of manufacturers of agricultural machines and components, in order to enhance the competitiveness of local manufacturers and to revitalize the agricultural machine market.
Purpose: This study compared the injury mechanism, site, type, initial management approach of orthopedic injury, and outcomes according to the injury severity in moderate-to-severe injured patients. Materials and Methods: During 57-month, excluding the period when the authors' emergency/trauma center was not operating, from 2014 to 2019, a retrospective study was conducted on 778 patients with orthopedic injuries among patients with an Injury Severity Score (ISS)>9 scored. The patients were classified into moderate-injured group (group-1, 679) and severe-injured group (group-2, 99) according to the injury severity based on the ISS and physiologic parameters. The injury mechanism and non-orthopedic injury were evaluated. Orthopedic injuries were assessed according to the injury pattern and the number of anatomical regions and bone sites involved. The management approach for the orthopedic injuries in two groups was compared. Outcomes (hospital stay, systemic complications, and in-hospital mortality) were evaluated, and the risk factors for mortality were analyzed. Results: In group-2, the incidence of younger males, high-energy mechanisms, and accompanying injuries was significantly higher than in group-1. The number of anatomical regions and bone sites involved increased in group-2. The involvement of the pelvis, spine, and upper extremity was significantly higher in group-2, whereas group-1 was involved mainly by the lower extremities. Depending on the patient's condition, definitive or staged management for orthopedic injuries may be used. Group-1 was treated mainly with definite fixation after the physiological stabilization process, and group-2 was treated with staged management using temporary external fixation. The hospital stay was significantly longer in group-2. The overall systematic complications and in-hospital mortality was approximately 4.9% and 4.5%. A higher injury severity was associated with higher in-hospital mortality (2.9%, 15.2%; p<0.0001). Increasing age and high ISS are independent risk factors for mortality. Conclusion: A higher severity of injury was associated with a higher incidence of high-energy mechanism, younger, male, accompanying injuries, and the frequency and severity of orthopedic injuries. Severe polytrauma patients were treated mainly with a staged approach, such as external fixation. The hospital stay, systematic complications, and in-hospital mortality were significantly higher in severe-injured patients. Age and ISS are strong predictors of in-hospital mortality in polytrauma.
Recently, prior to the commercialization of urban air mobility (UAM), the importance of R&D for air transportation-related industries in urban areas has significantly increased. To create a UAM environment, research is being conducted on personal air vehicles (PAVs). They are key means of air transportation, but research on the physical factors influencing their passengers is relatively insufficient. In particular, because the PAV is expected to be used as a living space for the passengers, research on the effects of the physical elements generated in the PAV on the human body is essential to design an interior space that supports the in-vehicle activities of the passengers. Therefore, the purpose of this study is to derive the constraint factors that affect the human body due to the air navigation characteristics of the PAV and to understand the impact of these constraint factors on the bodies of the passengers performing in-vehicle activities. The results of this study indicate that when the PAV was operated at less than 4,000 ft, which is the operating standard, the constraint factors were noise, vibration, and motion sickness caused by low-frequency motion. These constraint factors affect in-vehicle activity; thus, the in-vehicle activities that can be performed in a PAV were derived using autonomous cars, airplanes, and PAV concept cases. Furthermore, considering the impact of the constraint factors and their levels on the human body, recommended constraint factor criteria to support in-vehicle activities were established. To reduce the level of impact of the constraint factors on the human body and to support in-vehicle activity, the seat's shape and built-in functions of the seat (vibration reduction function, temperature control, LED lighting, etc.) and external noise reduction using a directional speaker for each individual seat were recommended. Moreover, it was suggested that interior materials for noise and vibration reduction should be used in the design of the interior space. The contributions of this study are the determination of the constraint factors affecting the in-vehicle PAV activity and the confirmation of the level of impact of the factors on the human body; in the future, these findings can be used as basic data for suitable PAV interior design.
This study attempted to contribute to the clinical application of implant operation by making a quantitative nerve examination using a neurometer for the evaluation of sensory disturbances that could be incurred after the implantation in the dental clinics, and it intended to establish an objective guideline in the evaluation of sensory nerve after the operation of implant. An inspection was performed with the frequencies of 2000Hz, 250 Hz and 5 Hz before and after the operations of tooth implant using
The wall shear stress in the vicinity of end-to end anastomoses under steady flow conditions was measured using a flush-mounted hot-film anemometer(FMHFA) probe. The experimental measurements were in good agreement with numerical results except in flow with low Reynolds numbers. The wall shear stress increased proximal to the anastomosis in flow from the Penrose tubing (simulating an artery) to the PTFE: graft. In flow from the PTFE graft to the Penrose tubing, low wall shear stress was observed distal to the anastomosis. Abnormal distributions of wall shear stress in the vicinity of the anastomosis, resulting from the compliance mismatch between the graft and the host artery, might be an important factor of ANFH formation and the graft failure. The present study suggests a correlation between regions of the low wall shear stress and the development of anastomotic neointimal fibrous hyperplasia(ANPH) in end-to-end anastomoses. 30523 T00401030523 ^x Air pressure decay(APD) rate and ultrafiltration rate(UFR) tests were performed on new and saline rinsed dialyzers as well as those roused in patients several times. C-DAK 4000 (Cordis Dow) and CF IS-11 (Baxter Travenol) reused dialyzers obtained from the dialysis clinic were used in the present study. The new dialyzers exhibited a relatively flat APD, whereas saline rinsed and reused dialyzers showed considerable amount of decay. C-DAH dialyzers had a larger APD(11.70
The wall shear stress in the vicinity of end-to end anastomoses under steady flow conditions was measured using a flush-mounted hot-film anemometer(FMHFA) probe. The experimental measurements were in good agreement with numerical results except in flow with low Reynolds numbers. The wall shear stress increased proximal to the anastomosis in flow from the Penrose tubing (simulating an artery) to the PTFE: graft. In flow from the PTFE graft to the Penrose tubing, low wall shear stress was observed distal to the anastomosis. Abnormal distributions of wall shear stress in the vicinity of the anastomosis, resulting from the compliance mismatch between the graft and the host artery, might be an important factor of ANFH formation and the graft failure. The present study suggests a correlation between regions of the low wall shear stress and the development of anastomotic neointimal fibrous hyperplasia(ANPH) in end-to-end anastomoses. 30523 T00401030523 ^x Air pressure decay(APD) rate and ultrafiltration rate(UFR) tests were performed on new and saline rinsed dialyzers as well as those roused in patients several times. C-DAK 4000 (Cordis Dow) and CF IS-11 (Baxter Travenol) reused dialyzers obtained from the dialysis clinic were used in the present study. The new dialyzers exhibited a relatively flat APD, whereas saline rinsed and reused dialyzers showed considerable amount of decay. C-DAH dialyzers had a larger APD(11.70