Infrared Target Extraction Using Weighted Information Entropy and Adaptive Opening Filter

  • Bae, Tae Wuk;Kim, Hwi Gang;Kim, Young Choon;Ahn, Sang Ho
    • ETRI Journal
    • /
    • v.37 no.5
    • /
    • pp.1023-1031
    • /
    • 2015
  • In infrared (IR) images, near targets have a transient distribution at the boundary region, as opposed to a steady one at the inner region. Based on this fact, this paper proposes a novel IR target extraction method that uses both a weighted information entropy (WIE) and an adaptive opening filter to extract near finely shaped targets in IR images. Firstly, the boundary region of a target is detected using a local variance WIE of an original image. Next, a coarse target region is estimated via a labeling process used on the boundary region of the target. From the estimated coarse target region, a fine target shape is extracted by means of an opening filter having an adaptive structure element. The size of the structure element is decided in accordance with the width information of the target boundary and mean WIE values of windows of varying size. Our experimental results show that the proposed method obtains a better extraction performance than existing algorithms.

Development of an Automatic Face Velocity Controller for a Fume Hood System (흄후드 시스템의 면 풍속 자동 제어기 개발)

  • Kim, Hogeol;Jeong, Kyuwon
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.22 no.2
    • /
    • pp.304-309
    • /
    • 2013
  • In chemical, medical or biology laboratories Fume Hoods are basic facilities which can protect researchers from dangerous gas as blowing the contaminated air outside. After the air inside the laboratory room is sucked into the hume hood, then, it is blew out by a fan rotated by an AC induction motor. In addition, a damper controls the inside opening of a duct, which the air flows through. The face velocity, air velocity through the front door, have to be kept constant as the set value even though the opening of the door is varied. However, conventional fume hood used to be operated by operator's manual switches. So that, in this paper an automatic control system is developed which controls the face velocity by adjusting the rotating speed of the blow motor and the opening of the damper. Experiments show that this developed system can be used at such laboratories.

Development of an Automatic Cap Opening And Closing Device for Unmanned Chemical Manufacturing Processes (화학제조공정의 무인화를 위한 자동 캡 개폐장치 개발)

  • Jun-Sik Lee;Oh-Seong Kwon;Jun-Ho Lee
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.27 no.1
    • /
    • pp.71-76
    • /
    • 2024
  • Automatic production systems are constantly advancing technologies to improve productivity and safety. Specifically, liquid filling machines are primarily utilized to package products into drums after manufacturing process in the hazardous chemical industry. Most existing filling machines allow the operator to open the drum cap and inject the product directly or semi-automation. In this study, we have developed a cap opening and closing mechanism onto the existing drum filling machine, enabling automatic and safe cap manipulation while filling the product in the IBC tank. By applying the appropriate torque value through numerical analysis, we confirmed that the system worked without any problems during the process of opening and closing the cap. Therefore, it is expected that the developed machine will give more production and reduce human efforts without risk in the chemical packaging industry.

3D Segmentation of a Diagnostic Object in Ultrasound Images Using LoG Operator (초음파 영상에서 LoG 연산자를 이용한 진단 객체의 3차원 분할)

  • 정말남;곽종인;김상현;김남철
    • Journal of Biomedical Engineering Research
    • /
    • v.24 no.4
    • /
    • pp.247-257
    • /
    • 2003
  • This paper proposes a three-dimensional (3D) segmentation algorithm for extracting a diagnostic object from ultrasound images by using a LoG operator In the proposed algorithm, 2D cutting planes are first obtained by the equiangular revolution of a cross sectional Plane on a reference axis for a 3D volume data. In each 2D ultrasound image. a region of interest (ROI) box that is included tightly in a diagnostic object of interest is set. Inside the ROI box, a LoG operator, where the value of $\sigma$ is adaptively selected by the distance between reference points and the variance of the 2D image, extracts edges in the 2D image. In Post processing. regions of the edge image are found out by region filling, small regions in the region filled image are removed. and the contour image of the object is obtained by morphological opening finally. a 3D volume of the diagnostic object is rendered from the set of contour images obtained by post-processing. Experimental results for a tumor and gall bladder volume data show that the proposed method yields on average two times reduction in error rate over Krivanek's method when the results obtained manually are used as a reference data.

Decay Beat Removal and Operator's Intervention During A Very Small L()CA (매우 작은 규모의 냉각재 상실 사고 동안 잔열 제거와 운전자의 개입)

  • Hee Cheon No
    • Nuclear Engineering and Technology
    • /
    • v.16 no.1
    • /
    • pp.11-17
    • /
    • 1984
  • Sample calculations were done for KORI-1 to develop a better understanding of what happens after very small LOCA ($\leq$0.05 ft$^2$). For a water-side break with the break size larger than 0.006 ft$^2$, fluid-loss through break exceeds the makeup. If the break size is larger than 0.008ft$^2$, decay heat can be completely removed through break. Based on these results, it was concluded that KORI-1 is fairly safe for the whole spectrum of sizes in very small LOCA. However, for the reactor with 900 MWe or 1200 MWe, a certain spectrum of sizes in very small LOCA should be carefully considered. In the accident sequence the transition from natural circulation to pool boiling or from pool boiling to natural circulation may be troublesome to the operator or in the safety analysis. Operator's intervention was discussed; primary pump shutoff, HPI pump shutoff, break isolation, and opening relief valve. It was proved that continuous operation of HPI pumps after shutdown will not threaten the integrity of the primary system.

  • PDF

Common Errors in Endodontic treatment

  • Kim, Jin-Woo
    • Proceedings of the KACD Conference
    • /
    • 2001.05a
    • /
    • pp.257-257
    • /
    • 2001
  • Failures occur in dentistry as a result of manny factors some of which can be controlled by the operator whilst others are unavoidable. The long-term success rate of endodontic treatment has often been thought to be very high although studies reported in the literature do not support this perception. The number of failure can be reduced by adhereing to accepted treatment procedures and by avoiding 'short cut'. Endodontic disaters are usually related to operator errors and they mat have detrimental effects on the outcome of treatment in the long term, eventually becoming catastrophes. Endodontic disasters will require special techniques to salvage them whereas catastrophes usually result in loss of the tooth and every effort should be made to prevent such problems from occurring. This presentation will cover common errors in endodontic procedures especially access opening, canal negotiation, canal irrigation, canal preparation, canal filling, post preparation.ration.

  • PDF

Development of Automatic Operating System for Exit Door using RF (무선을 이용한 비상문 자동개폐 시스템 개발)

  • Lim Youn-Sub;Hwang Byung-Kon
    • Journal of Korea Society of Industrial Information Systems
    • /
    • v.11 no.1
    • /
    • pp.7-12
    • /
    • 2006
  • In this paper, we develop a control system with fire receiver and emergency light that controls (manages) emergency door by wireless signals which prevents crime but also helps evacuate in (fire) emergency. This automatic door operator can be installed on any buildings which have a problem of opening or shutting emergency doors, and it is especially good for buildings with high fire vulnerabilities such as complex buildings, apartments and multistoried buildings without easy control of rooftop doors.

  • PDF

A Flow Analysis of a Refrigeration Warehouse where an Unusual Death of an Operator Occurred by Deficiency of Oxygen

  • Park, Chan-Seong;Moon, Jung-Eun;Kim, Yoon-Ho;Kim, Jin-Pyo
    • International Journal of Safety
    • /
    • v.5 no.2
    • /
    • pp.29-33
    • /
    • 2006
  • A numerical flow analysis of the case of a refrigeration warehouse where an unusual death of an operator occurred by deficiency of oxygen is performed by using STAR-CD program of the computational fluid dynamics (CFD) code. The refrigeration room of the warehouse for storing the fruits maintains an atmosphere of 95% nitrogen and 5% oxygen by volume. When the operator was found dead in the refrigeration room, the room was in normal operating conditions except for the fact that the auxiliary door had been left open. For the flow analysis, unsteady 3-dimensional natural convection with mass transfer is considered. The flow analysis result is compared with the oxygen concentration level measured against time during on-site investigation. The change in oxygen concentration level in the warehouse due to the opening of the auxiliary door is found to be negligible.

(Distance and Speed Measurements of Moving Object Using Difference Image in Stereo Vision System) (스테레오 비전 시스템에서 차 영상을 이용한 이동 물체의 거리와 속도측정)

  • 허상민;조미령;이상훈;강준길;전형준
    • Journal of the Korea Computer Industry Society
    • /
    • v.3 no.9
    • /
    • pp.1145-1156
    • /
    • 2002
  • A method to measure the speed and distance of moving object is proposed using the stereo vision system. One of the most important factors for measuring the speed and distance of moving object is the accuracy of object tracking. Accordingly, the background image algorithm is adopted to track the rapidly moving object and the local opening operator algorithm is used to remove the shadow and noise of object. The extraction efficiency of moving object is improved by using the adaptive threshold algorithm independent to variation of brightness. Since the left and right central points are compensated, the more exact speed and distance of object can be measured. Using the background image algorithm and local opening operator algorithm, the computational processes are reduced and it is possible to achieve the real-time processing of the speed and distance of moving object. The simulation results show that background image algorithm can track the moving object more rapidly than any other algorithm. The application of adaptive threshold algorithm improved the extraction efficiency of the target by reducing the candidate areas. Since the central point of the target is compensated by using the binocular parallax, the error of measurement for the speed and distance of moving object is reduced. The error rate of measurement for the distance from the stereo camera to moving object and for the speed of moving object are 2.68% and 3.32%, respectively.

  • PDF

Orbital Floor Reconstruction through Endoscopic Transnasal Approach Alone (안와하벽 파열 골절에 대한 내시경적 접근법만을 이용한 재건술)

  • Bae, Seong Hwan;Kang, Kyung Dong;Nam, Su Bong;Bae, Yong Chan;Choi, Soo Jong
    • Archives of Craniofacial Surgery
    • /
    • v.13 no.2
    • /
    • pp.99-103
    • /
    • 2012
  • Purpose: Many surgical methods for reconstruction of orbital floor fracture have been reported, which include subciliary approach, transconjunctival approach, transantral and transnasal endoscopic approach, etc. The purpose of this study is to demonstrate a surgical technique and analyze the results of transnasal endoscopic approach with Foley catheter ballooning without implantation of artificial surgical material through subciliary approach. Methods: Between February 2007 and November 2010, 29 orbital floor fracture patients, who had no herniated muscles through bone fragments, were treated through transnasal endoscopic approach with Foley catheter ballooning. Under the endoscopic view, the operator identified the opening of maxillary sinus. After widening of the opening using forceps, the operator reduced the fragmented bone with curved suction tip. Thereafter, 18-Fr Foley catheter was inserted. Four weeks after the operation, the catheter was removed. Results: Preoperatively, 6 patients had diplopias, 4 patients had limitations of extraocular motions and 3 patients had enophthalmos. After removal of the Foley catheter 4 weeks after the operation, 2 patients had diplopias, 1 patient had a limitation of extraocular motion, 1 patient has an enophthalmos and 1 patient had numbness on the cheek. These symptoms were resolved about 6 months after the surgery. Conclusion: The operative technique of Foley catheter ballooning through transnasal endoscopic approach without implantation of the artificial surgical material through subciliary approach can be considered one of the appropriate techniques for orbital floor fracture.