Decay Beat Removal and Operator's Intervention During A Very Small L()CA

매우 작은 규모의 냉각재 상실 사고 동안 잔열 제거와 운전자의 개입

  • Hee Cheon No (Korea Advanced Institute of Science and Technology)
  • Published : 1984.03.01

Abstract

Sample calculations were done for KORI-1 to develop a better understanding of what happens after very small LOCA ($\leq$0.05 ft$^2$). For a water-side break with the break size larger than 0.006 ft$^2$, fluid-loss through break exceeds the makeup. If the break size is larger than 0.008ft$^2$, decay heat can be completely removed through break. Based on these results, it was concluded that KORI-1 is fairly safe for the whole spectrum of sizes in very small LOCA. However, for the reactor with 900 MWe or 1200 MWe, a certain spectrum of sizes in very small LOCA should be carefully considered. In the accident sequence the transition from natural circulation to pool boiling or from pool boiling to natural circulation may be troublesome to the operator or in the safety analysis. Operator's intervention was discussed; primary pump shutoff, HPI pump shutoff, break isolation, and opening relief valve. It was proved that continuous operation of HPI pumps after shutdown will not threaten the integrity of the primary system.

매우 작은 규모의 냉각재 상실 사고후($\leq$0.05ft$^2$) 어떤 일이 일어나는 가를 더 잘 이해하기 위해 고리 1호기에 대한 샘플 계산을 수행하였다 깨진 크기가 0.006 ft$^2$ 보다 큰 사고에 대해서는 냉각재 상실이 보충되는 양을 초과한다. 0.008 ft$^2$ 보다 큰 깨진 크기에 대해서는 잔열은 깨진 곳을 통해 완전히 제거된다. 이와 같은 결과에 비추어 고리 1호기는 매우 작은 규모의 냉각재 상실 사고의 전 영역에 걸쳐 비교적 안전하다고 결론지었다. 하지만, 900MWe 나 1200MWe 를 가진 원자로에 있어서, 어떤 깨진 크기에 대해서는 이 사고가 주의깊게 고려되어야 한다. 자연 순환에서 pool boiling 으로 또는 pool boiling에서 자연 순환으로 천이할때, 특별히 운전자와 안전 분석에 문제점을 남긴다. Primary pump shutoff, HPI pump shutoff, break isolation, opening relief valve의 운전자 간섭에 대해서도 논의 되었다. Shutoff 후 HPI pump의 연속적인 운전은 primary system의 건전성을 위협하지 않는다는 것이 증명되었다.

Keywords