• 제목/요약/키워드: oneM2M standards

Search Result 147, Processing Time 0.029 seconds

ANISOTROPY CONSTANTS OF $(Sm_{0.5}RE_{0.5})Fe_{11}Ti$ COMPOUNDS (RE=RARE EARTH)

  • Kim, H.T.;Kim, Y.B.;Park, W.S.;Kim, C.S.;Kim, T.K.;Jin, Han-Min
    • 한국자기학회지
    • /
    • 제5권5호
    • /
    • pp.683-686
    • /
    • 1995
  • Using by the x-ray diffractometry(XRD), the thermomagnetic analysis(TMA), a scanning electron microscopy (SEM-EDX), we knew that the $(Sm_{0.5}RE_{0.5})Fe_{11}Ti$ (RE=Ce,Pr,Nd,Sm,Gd,Tb) compounds were formed to tetragonal $ThMn_{12}$-type structure having a uniaxial magnetocrystalline anisotropy with easy magnetization c-axis. The intrinsic magnetic properties of those were determined by fitting the two magnetization curves of experimental and calculation magnetization. The anisotropy constant $K_{1}$ of this compounds was in the range of $1.75\;-\;9.2\;MJ/m^{3}$ and approximately one order higher than $K_{2}$. $SmFe_{11}Ti$ had the highest anisotropy of $K_{1}\;=\;9.2\;MJ/m^{3}$, $K_{2}\;=\;0.4\;MJ/m^{3}$ and ${\mu}_{o}H_{A}=\;19.8\;T$ among the compounds, substitution of any other rare earth elements for Sm decreased magnetocrystalline anisotropy.

  • PDF

IoT-enabled Solutions for Tour Photography Services

  • Jeong, Isu;Baek, Seungwoo;An, Eunsol;Kim, Yujin;Choi, Jiwoo;Yun, Jaeseok
    • 한국컴퓨터정보학회논문지
    • /
    • 제25권5호
    • /
    • pp.127-135
    • /
    • 2020
  • 본 논문에서는 관광 서비스 산업 분야에서 소규모 투자와 최소한의 인력만으로 경제적/사회적/문화적 효과를 이끌어낼 수 있는 관광 사진 촬영 서비스를 제공하기 위한 IoT 기반 솔루션을 제안한다. 오픈 하드웨어 플랫폼과 국제 IoT 표준인 oneM2M 기반 소프트웨어 플랫폼을 활용하여 원격 제어가 가능한 IoT 카메라를 구현하고 이 과정에서 센서 및 액추에이터들을 oneM2M 표준 디바이스로 변환이 가능한 미들웨어를 개발하였다. 포토존에 설치된 IoT 카메라는 oneM2M 기반 게이트웨이에서 제공하는 웹앱 인터페이스를 통해 앵글 조절이 가능하고 촬영한 이미지를 사용자 스마트폰으로 전달할 수 있다. 관광지 밖에서도 사용자에게 부여된 식별자를 이용하여 동일한 방식으로 촬영했던 사진 다운로드가 가능하다. 본 연구에서 제안한 솔루션을 발판으로 복합 서비스 산업 중 하나인 관광 분야에서도 IoT 관련 기술들이 보다 활발히 적용되기를 기대한다.

loT 장치 관리 표준 및 YANG 기반의 관리 정보 설계 (Device Management Standards of IoT and YANG based Management Information Design)

  • 최수길;최미정
    • 한국정보처리학회:학술대회논문집
    • /
    • 한국정보처리학회 2015년도 춘계학술발표대회
    • /
    • pp.228-230
    • /
    • 2015
  • 차세대 성장동력으로 각광받고 있는 사물인터넷은 국제 표준 혐의체인 oneM2M의 주도 아래 표준화가 진행중이다. 사물인터넷은 모든 사물이 연결되는 초연결성이라는 점과 연산 능력, 메모리, 배터리 등에 많은 한계를 갖는 제약 많은 장치가 대상이라는 두가지 큰 특징이 있다. 본 논문에서는 oneM2M의 장치 관리 표준에 대해서 설명한다. 또한 사물인터넷의 기술적 이슈를 해결하기 위해 등장한 CoAP 기반의 LWM2M 표준 기술을 소개하고 이를 데이터 모델링 언어인 YANG 기반의 장치관리 정보 설계를 제안한다.

Study on the Defects Detection in Composites by Using Optical Position and Infrared Thermography

  • Kwon, Koo-Ahn;Park, Hee-Sang;Choi, Man-Yong;Park, Jeong-Hak;Choi, Won Jae
    • 비파괴검사학회지
    • /
    • 제36권2호
    • /
    • pp.130-137
    • /
    • 2016
  • Non-destructive testing methods for composite materials (e.g., carbon fiber-reinforced and glass fiber-reinforced plastic) have been widely used to detect damage in the overall industry. This study detects defects using optical infrared thermography. The transient heat transport in a solid body is characterized by two dynamic quantities, namely, thermal diffusivity and thermal effusivity. The first quantity describes the speed with thermal energy diffuses through a material, whereas the second one represents a type of thermal inertia. The defect detection rate is increased by utilizing a lock-in method and performing a comparison of the defect detection rates. The comparison is conducted by dividing the irradiation method into reflection and transmission methods and the irradiation time into 50 mHz and 100 mHz. The experimental results show that detecting defects at 50 mHz is easy using the transmission method. This result implies that low-frequency thermal waves penetrate a material deeper than the high-frequency waves.

액체질소 냉각형광대역 cw CO 레이저 (A $LN_2$-cooled, Broadband cw CO Laser)

  • 김용평;최종운;원종욱
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1989년도 하계종합학술대회 논문집
    • /
    • pp.667-671
    • /
    • 1989
  • The CO laser is one of powerful light source for laser magnetic resonance spectroscopy in the mid-infrared region of the spectrum because of its wideband operational characteristics. In this work, a liquid nitrogen cooled cw CO laser is developed to allow broad-band operation from 5 to 8 ${\mu}m$. The design details will be presented.

  • PDF

IoT 기반 벼농사 생장 물 관리 시스템 연구 (A Study on the Rice growing water-management System based on IoT)

  • 남강현
    • 한국전자통신학회논문지
    • /
    • 제11권10호
    • /
    • pp.989-994
    • /
    • 2016
  • 본 연구는 논에 적용된 수위센서, 송수구 그리고 배수구 장치를 통하여 수위 관리를 수행 한다. 게이트웨이는 LoRa 접속을 통하여 수위센서 물높이 정보를 IoT(: Internet of Thing) 플랫폼에 oneM2M(: Machine to Machine) 규격으로 정보전달 한다. IoT 플랫폼에서 요청하는 물의 높이에 따라서, 게이트웨이는 송수구 또는 배수구 모터 스위치를 On 또는 Off하고 수위센서 정보를 전달한다. IoT 플랫폼은 물높이의 조건에 따라 지능적인 어플리케이션 기능을 수행한다.

Development of an Isotope-Dilution Liquid Chromatography/Mass Spectrometric Method for the Accurate Determination of Acetaminophen in Tablets

  • Shin, Hyun-Ju;Kim, Byung-Joo;Lee, Joon-Hee;Hwang, Eui-Jin
    • Bulletin of the Korean Chemical Society
    • /
    • 제31권12호
    • /
    • pp.3663-3667
    • /
    • 2010
  • Acetaminophen (N-acetyl-p-aminophenol) is one of the most popular analgesic and antipyretic drugs. An isotope dilution mass spectrometric method based on LC/MS was developed as a candidate reference method for the accurate determination of acetaminophen in pharmaceutical product. After spiking an isotope labeled acetaminophen (acetyl-$^{13}C_2$, $^{15}N$-acetaminophen) as an internal standard, tablet extracts were analyzed by LC/MS in a selected reaction monitoring (SRM) mode to detect ions at m/z $152{\rightarrow}110$ and m/z $155{\rightarrow}111$ for acetaminophen and acetyl-$^{13}C_2$, $^{15}N$-acetaminophen, respectively. The repeatability and reproducibility of the developed ID/LC-MS method were tested for the validation and assessment of metrological quality of the method.

후박(厚朴)의 외.내부형태 및 이화학패턴연구 (A Study of Morphology and Pattern Analysis in Magnoliae Cortex)

  • 이금산;김정훈;최고야;강대훈;황성연;정승일;김홍준;주영승
    • 대한본초학회지
    • /
    • 제23권4호
    • /
    • pp.21-29
    • /
    • 2008
  • Objectives: To determine the standards for discrimination of Magnoliae Cortex, the experiment of specific external-internal characters and the physicochemical pattern analysis were performed. Methods: External characteristics was observed using a stereoscope. Paraffin-mediated sectioned materials were stained by Ju's method. Physicochemical patterns of materials were analyzed using HPLC. Results: 1. Botanical characteristics: Magnolia officinalis had one seed and a white flower, while M. obovata had two seeds and a white flower. Machilus thunbergii had berry and spherical fruits and yellowish green panicles. 2. External characteristics: M. officinalis and M obovata were dark and thick. M. officinalis was gray brown and greasy while M. obovata was light-gray, less oily and smoothly sectioned. Machilus thunbergii was thin and relatively light or yellow-brown, coarsely sectioned and faintly specific scents. 3. Internal characteristics: The bast parts of M. officinalis and M. obovata were commonly wider than Machilus thunbergii The cork cortex of M. officinalis was $10{\sim}mg/L$ cell layers with many oil cells, while that of M. obovata was $4{\sim}7$ cell layers with less oil cells. Machilus thunbergii's xylem which consisted of ring-shaped cambium at 1st and 2nd part was occupied in large portion. 4. Physicochemical pattern: Both M. officinalis and M. obovata involved honokiol and magnolol. All kinds of M. officinalis involved Magnatriol B but one kind of M. ovobata and all of Machilus thunbergii didn't. Machilus thunbergii showed different pattern of chromatogram from that of 2 species above. Conclusions: These results could be used as standards for discrimination of Magnoliae Cortex and as the method of objectification in medicinal herbs giving the basic resource for bioactivity research.

  • PDF

중환자실 병상주변공간의 면적과 간격에 관한 연구 (A Study on the Area and Clearances around Patient Bed Space in Intensive Care Unit)

  • 이현진;권순정
    • 의료ㆍ복지 건축 : 한국의료복지건축학회 논문집
    • /
    • 제25권3호
    • /
    • pp.47-55
    • /
    • 2019
  • Purpose: This study tries to propose the dimensions and area related to patient bed and surroundings in ICU considering nurses' observation and medical care. Methods: Literature survey, 11 Case studies, some Interviews with nurses and measuring of medical equipments' dimension in ICU have been mobilized in order to deepen the ICU bed area standards. Results: 0.3m clearance between head wall and patient bed is necessary for emergency cases. The minimum distance at the foot of the bed should not be less than 0.9m for EMR cart and medical tray. The clear floor area of one bed and surroundings in open ward is $10.2m^2(3m{\times}3.4m)$. In a single-bed patient room, the minimum clear floor area is $16.0m^2(4m{\times}4m)$. Considering the control of cross infection in ICU, Single bed patient room is recommended. Implications: The result of this study can be applied to the design of ICU and legislation of ICU standard.

Accuracy Assessment for Measuring Surface Figures of Large Aspheric Mirrors

  • Kim, Young-Soo;Ahn, Ki-Beom;Park, Kwi-Jong;Moon, Il-Kweon;Yang, Ho-Soon
    • Journal of the Optical Society of Korea
    • /
    • 제13권2호
    • /
    • pp.178-183
    • /
    • 2009
  • At the time that the Keck-I 10m telescope was constructed in 1993, the era of Very Large Telescopes (VLTs) was opened. Now thirteen VLTs are in operation, and the largest of the monolithic mirrors is 8.4 m in diameter. Such monolithic mirrors are mostly aspheric and require high accuracies on the surface figures, reaching up to the diffraction limit. At present, next generation telescopes, Giant telescopes, are being developed. One is the GMT (Giant Magellan Telescope) whose size is 25.4 m in diameter. The primary mirror consists of seven segments figuring elliptical shapes on the surface. The surrounding six segments are off-axis and the edges are steep, as the fast focal ratio is adopted. It means that testing of the mirrors is a challenging task. In this paper, testing methods for the GMT primary mirror are reviewed, and accuracy of measuring devices is assessed. Results and discussions follow.