• 제목/요약/키워드: one-third octave

검색결과 17건 처리시간 0.026초

IEC 규격에 따른 풍력 터빈 소음의 현장 실증 (Field Test and Evaluation of Wind Turbine Noise according to IEC Standards)

  • 정철웅;정성수;정완섭;신수현;전세종;이생희
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2005년도 제17회 워크샵 및 추계학술대회
    • /
    • pp.579-582
    • /
    • 2005
  • The sound measurement techniques in IEC 61400-11 are applied to field test and evaluation of noise emission from 1.5 MW wind turbine generator (WTG) at Yongdang-Lee and 650 kW WTG at Hangwon-Lee in Jeju Island. Apparent sound power level, wind speed dependence and third-octave band levels are evaluated for both of WTGs. 1.5 MW WTG at Yongdang is found to emit lower sound power than 660 kW one at Hangwon, which seems to be due to lower rotating speed of the rotor of WTG at Yongdang. Equivalent continuous sound pressure level s (ECSPL) of 650 kW WTG at Hangwon vary more widely with speed than those of 1.5 MW WTG at Yongdang. The reason for this is believed to be the fixed blade-rotating speed of WTG at Yongdang. One-third octave band analysis of the measured data show that the band components around 400-500 Hz are dominant for 1.5 MW WTG at Yongdang and those around 1K Hz are dominant for 660 kW WTG at Hangwon.

  • PDF

제주도 용당/행원 풍력발전기 현장 소음 실증 (Field Test and Evaluation of Noise from Wind Turbine Generators at Yongdang and Hangwon in Jeju Island)

  • 정철웅;정성수;정완섭;신수현;전세종;이생희
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2005년도 추계학술대회논문집
    • /
    • pp.818-821
    • /
    • 2005
  • The sound measurement procedures of IEC 61400-11 are applied to field test and evaluation of noise emission from 1.5 MW wind turbine generator (WTG) at Yongdang and 660 kW WTG at Hangwon in Jeju Island. Apparent sound power level, wind speed dependence and third-octave band levels are evaluated for both of WTGs. 1.5 MW WTG at Yongdang is found to emit lower sound power than 660 kW one at Hangwon, which seems to be due to lower rotating speed of the rotor of WTG at Yongdang. Equivalent continuous sound pressure levels (ECSPL) of 660 kW WTG at Hangwon vary more widely with wind speed than those of 1.5 MW WTG at Yongdang. The reason for this is believed to be the fixed blade rotating speed of WTG at Yongdang. One-third octave band analysis of the measured data show that the band components around 400-500 Hz are dominant for 1.5 MW WTG at Yongdang and those around 1K Hz are dominant for 660 kW WTG at Hangwon.

  • PDF

Time Stretched Pulse를 이용한 무향실 자유음장 분석 (Analysis of free field for Acoustic Anechoic Chamber based on Time Stretched Pulse)

  • 김건욱
    • 대한전자공학회논문지SP
    • /
    • 제49권4호
    • /
    • pp.111-119
    • /
    • 2012
  • Time Stretched Pulse (TSP)는 공간적으로 임펄스(Impulse)를 효율적으로 전달하고 분석하기 위해서 사용되어 진다. 하지만 발신기와 수신기의 전달함수를 포함시키지 않으면, 시간 영역에서의 분석은 직, 간접 신호의 중첩으로 공간의 자유음장 특성을 파악하기 불가능하다. 일반적으로 공간의 자유음장(Free Field)은 표준 ISO 3745 Annex A에 의해서 평가되고 있는데, 일정 주파수 간격의 1/3 옥타브 밴드 신호를 연속적으로 발신 및 수신하여 거리별 신호 감소를 역자승 법칙(Inverse Square Law)을 적용하여 판단하고 있다. 본 논문은 자유음장 분석에서 TSP 신호를 적용하여 일반적인 ISO 3745의 1/3 옥타브 밴드 신호와 비교하였다. 역자승 모델 값과의 차이점을 분석한 결과 TSP 신호 또한 1/3 옥타브 밴드 신호와 유사한 결과를 보이고 있으며, 측정 시간 및 확장성에 대해서는 우수하게 판단되었다. 본 실험에서는 ISO 3745에 의해서 제한된 주파수 범위에서 자유음장과 반자유음장(Hemi-free Field)을 검증 받은 무향실을 사용하였다.

Design and Analysis of Experimental Anechoic Chamber for Localization

  • Kim, Keon-Wook
    • 한국음향학회지
    • /
    • 제31권4호
    • /
    • pp.225-234
    • /
    • 2012
  • The anechoic chamber is essential tool to measure the various acoustic parameters with high precision. The chamber provides the climate controlled indoor environments but requires the dedicated room at a great cost in order to isolate and absorb sound field. Provided the purpose of the chamber is specific to the experiments of sound localization, the performance requirements excluding free field can be alleviated for cost effective solution. This paper designs low cost and profile anechoic chamber based on acoustic pyramids and evaluates the performance specified by the Annex of ISO 3745. Data analysis is employed to measure the free and hemi-free field performance over five straight paths for working areas and four paths for non-working areas. The identical two measurement campaigns were conducted for free and hemi-free field chamber which is easily interchangeable by simple labor in this chamber design. In the working area with conventional speaker, the results of these analyses demonstrate that lab-designed anechoic chamber is in conformance with ISO 3745 for 250 Hz - 16 kHz one-third octave band at free field chamber and for 1 kHz - 16 kHz one-third octave band at hemi-free field chamber.

보-판 결합 구조물에서 에너지 흡수체로 작용하는 판의 특성에 따른 파워 전달 특성에 관한 연구 (An Investigation of Power Flow Mechanism in Beam-plate Built-up Structures with an Energy-absorbing Plate)

  • 유지우
    • 한국소음진동공학회논문집
    • /
    • 제17권1호
    • /
    • pp.55-64
    • /
    • 2007
  • In the built-up structure consisting of a stiff beam and a flexible plate, Grice showed that the plate behaves as an energy absorber in narrow frequency bands(called plate blocking effect). This paper deals with such beam-plate coupled structures, where the plate is an energy absorber and the excited beam is an energy path. It is found that such energy dissipation can occur in the relatively broad bands, if different stiffnesses are used in the rectangular plate. It was experimentally verified by Heckl that the energies in terms of one-third octave band averages transferred to the plate(or dissipated in the plate) increase for increased plate damping. This Paper, however, shows that the energy absorption suddenly reduces at the certain narrow frequency bands where the plate damping effect upon the coupled beam is maximum. Also, in order to minimize energy transfer through the beam in terms of one-third octave band averages, it is advantageous to increase the plate damping closer to the excitation point All these results are based on the wane method.

청탁의 음성학적 의미 (Phonetic meaning of clarity and turbidity)

  • 박한상
    • 말소리와 음성과학
    • /
    • 제9권4호
    • /
    • pp.77-89
    • /
    • 2017
  • This study investigates the phonetic meaning of clarity and turbidity(淸濁) that has been used in psychoacoustics, musicology, and linguistics in both the East and the West. With a view to clarifying the phonetic meaning of clarity and turbidity, this study conducts three perception tests. First, 34 subjects were asked to take one of Clear and Turbid by forced choice for 5 pure and complex tones, respectively, ranging from A2 to A6 differing by octave. Second, they were asked to select between the two choices for 25 pure and complex tones, respectively, ranging from A2 to A4 differing by semitone. Third, they were asked to opt for one of the two choices for 8 different vowels of different formant and fundamental frequencies. Results showed that there is a certain range of tone which is perceived as clear, that clarity level increases as fundamental frequency increases, and that pure tones have a higher level of clarity than complex ones, fundamental frequency being equal. Results also showed that vocal tract resonance enhances clarity level on the whole, and that lower vowels have a higher level of clarity than higher ones. This study is significant in that it demonstrates that clarity level is proportional to fundamental frequency and the first formant frequency, all else being equal.

고가선로에서 철도소음 전파예측에 관한 연구 (A Study on the Pediction of Train Noise Propagation From an Elvated Railway)

  • 주진수
    • 소음진동
    • /
    • 제8권2호
    • /
    • pp.289-296
    • /
    • 1998
  • To predict the noise propagation from an elevated railway, sound radiation characteristics of elevated structure are measured by using the sound intensity method. In the base of the results, we propose the source model of elevated structure noise and the calculation model for elevated railway noise. Acoustic model of the former is modeled a row of single sources with directivity cos .theta. positioned in the center of a bogie and arranged in the lower side of slabs. Also prediction model is presented with rolling noise and elevated structure noise calculated by considering the power level of a source for one-third octave band, ground absorption and barrier deflection. Noise level unit patterns of a passing train is calculated based on this model and the results are compared with available field data.

  • PDF

원음장에서의 충격성 소음전파에 관한 실험적 연구 (An Experimental Study on the Propagation of Impulse Noise in the Far Sound Field)

  • 송화영;제현수;이주원;이성태;이동훈
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2004년도 춘계학술대회논문집
    • /
    • pp.852-855
    • /
    • 2004
  • This experimental study describes the propagation characteristics of the impulse noise emitted from the exit of a straight pipe attached to the open end of a simple shock tube. The sound pressure level and directivity of the impulse noise propagating from the exit of pipe with several different diameters are measured in the far sound fold for the range of the incident shock wave Mach number between 1.07 and 1.26. The experimental results showed that the peak values of impulse noises had a strong dependance on the exit diameter of a pipe and the shock wave Mach number. The impulse noise had the directivity propagating toward to the pipe axis and the characteristics of inverse square law of propagation distance. Moreover, it was shown that the one-third octave band SPL of impulse noise was almost constant regardless of the frequency band.

  • PDF

Sound transmission of lightweight block walls and panels-Theory and Experiments

  • S Kandaswamy;A Ramachandraiah
    • 한국음향학회:학술대회논문집
    • /
    • 한국음향학회 2004년도 춘계학술발표대회 논문집 제23권 1호
    • /
    • pp.235-239
    • /
    • 2004
  • Sound transmission either as airborne or structure borne is a potential problem that occurs in buildings either from sources within or from outside. With the expansion of real estate activities in countries like India, the need to attend sound insulation requirements also assumes greater dimensions. The focus of this research is on studying the sound transmission characteristics of building structures made of hollow blocks, neocrete block, aerocon block and prefabricated panels such as Ferrocement panel. The tests were carried out the blocks with and without plastering and their sound reduction index was measured at one-third octave frequencies. In the case of ferrocement panels, different types of systems were tested in the TL suite. Panels with cavity, with cavity ties, with insulation, with stiffeners and with plasterboard were investigated. Sound reduction index of these panels was measured with additional quantities like longitudinal wavespeed, and loss factors (internal and total loss factor). Tests were also conducted on Cypcrete wall panel and Sandwiched wooden panel in a similar way. Theoretical investigations were carried out using Statistical Energy Analysis (SEA) for the above systems. Sound reduction index was then compared between the predicted and the measured values.

  • PDF

Comparison of Transfer Function Method and Reverberation Room Method in Measuring the Sound Absorption Coefficient of Rice Straw Particle Mat

  • Kang, Chun-Won;Jang, Eun-Suk;Jang, Sang-Sik;Kang, Ho-Yang
    • Journal of the Korean Wood Science and Technology
    • /
    • 제46권4호
    • /
    • pp.362-367
    • /
    • 2018
  • This study estimates the sound absorption capability of rice straw particle mats by two methods: the transfer function method and the reverberation room method. In the reverberation method, the central frequency was set to the one-third octave band in the 100-5000 Hz range; in the transfer function method, the frequency range was 500-6400 Hz. Both methods yielded similar noise reduction coefficients of the rice straw mats. The noise reduction coefficient was approximately 0.8, indicating a high sound-absorption property of the mats. Therefore, rice straw matting is a suitable candidate material for sound-barrier walls against highway noise.