• 제목/요약/키워드: on-state resistance

검색결과 1,163건 처리시간 0.023초

Online Estimation of SOC and Parameters of Battery Using Augmented Sigma-Point Kalman Filter and RLS

  • Hoang, Thi Quynh Chi;Nguyen, Hoang Vu;Lee, Dong-Choon
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2014년도 전력전자학술대회 논문집
    • /
    • pp.542-543
    • /
    • 2014
  • In this paper, an estimation scheme based on an augmented sigma-point Kalman filter to estimate the state of charge (SOC) of the battery is presented, where the battery parameters of the series resistance ($R_o$), diffusion capacitance ($C_1$) and resistance ($R_1$) are also estimated through the recursive least squares (RLS) for better accuracy of the SOC. The effectiveness of the proposed method is verified by simulation results.

  • PDF

High Frequency Grounding Impedances of Vertically-Driven Ground Rods

  • Kim, Tae-Ki;Lee, Bok-Hee;Jeon, Duk-Kyu
    • 조명전기설비학회논문지
    • /
    • 제23권7호
    • /
    • pp.41-48
    • /
    • 2009
  • Grounding impedance depends on the frequency of current flowing into a grounding system lightning in particular has a broad frequency spectrum from some tens of Hz to a few MHz. So the grounding impedance related to transient currents such as lightning should be measured. In this paper, the grounding impedances of vertically-driven ground rods of 10, 30 and 48[m] long are measured and analyzed as functions of the frequency of injected current and the feeding point. As a result, the longer the ground rod is, the lower the steady-state ground resistance is. However the grounding impedance of a vertically-driven ground rod at a high frequency is significantly increased. It is not always true that low grounding impedance follows from a low steady-state ground resistance. It is important to evaluate the high frequency performance of grounding systems for protection against lightning.

교육벤처창업을 위한 스마트러닝 사용자의 혁신저항과 이용의도에 관한 연구 (A Study of the Innovation Resistance of Users and Intention to Use toward Smart Learning for Education Business Ventures)

  • 조상훈;양홍석
    • 벤처창업연구
    • /
    • 제10권1호
    • /
    • pp.55-67
    • /
    • 2015
  • 본 연구는 최근 교육시장의 벤처기업이나 사내 벤처를 위한 혁신기술로 부상하고 있는 스마트러닝(Smart Learning)의 혁신저항에 대하여 연구하였다. 스마트러닝 학습 방법에 대한 지각된 혁신 특성의 상대적 이점, 복잡성 및 적합성이 혁신저항에 유의한 영향을 미치는지 알아보았다. 이어서 기존 학습법에 대한 태도와 지각된 자기효능이 혁신저항에 유의한 영향을 미치는지 알아보았다. 그리고 이용자의 이러한 혁신저항이 향후 이용에 영향을 미치는지 알아보았고, 인구통계에 따라 조절효과가 나타나는지 살펴보았다. 구조방정식 모형을 사용하여 분석한 결과, 상대적 이점만을 제외한 모든 요인이 혁신저항에 영향을 주는 것으로 나타났다. 이를 통해 혁신저항 역시 향후 이용의도에 유의한 영향을 미친다는 결과를 얻을 수 있었다.

  • PDF

용체화처리된 Mg-4%Zn 합금의 부식 저항성에 미치는 미량 Ca 첨가의 영향 (Effect of Trace Amount of Ca on Corrosion Resistance of Solutionized Mg-4%Zn Alloy)

  • 전중환;황인제
    • 열처리공학회지
    • /
    • 제29권4호
    • /
    • pp.168-175
    • /
    • 2016
  • Influence of trace amount of Ca addition on the corrosion resistance was comparatively investigated in solutionized Mg-4%Zn and Mg-4%Zn-0.1%Ca alloys. In as-cast state, the alloys were characterized by primary ${\alpha}-(Mg)$ dendrite with MgZn intermetallic compound particles. After solution-treatment, both alloys consisted of single ${\alpha}-(Mg)$ phase by dissolution of the compound particles into the matrix. It was found from the immersion and electrochemical corrosion tests that the Mg-4%Zn alloy had better corrosion resistance than the Mg-4%Zn-0.1%Ca alloy. Morphological and compositional analyses on the surface corrosion products indicate that the incorporation of Ca oxide with low PBR value into the surface corrosion products would be responsible for the decreased corrosion resistance of the Ca-containing alloy.

전기콘센트의 사용환경과 전류값에 따른 열적특성 및 절연저항 분석 (Analysis of Thermal Characteristics and Insulation Resistance based on Usage Environment and Current Value of Electrical Socket Outlet)

  • 김경천;김두현;김성철
    • 한국안전학회지
    • /
    • 제34권5호
    • /
    • pp.22-30
    • /
    • 2019
  • In 2018, overload, overcurrent, insulation aging, and a contact failure caused 659 electric fires. There is almost no failure of electrical socket outlets during their manufacturing or installation period. After several months or several years, overload or overcurrent of electrical socket outlets leads to a contact failure or short circuit which causes an electric fire. Therefore, this paper analyzed for thermal characteristics based on a current value and the change in insulation resistance along with a temperature rise caused by electrical socket outlets and the state of laboratory use in workplaces. As a results, regarding the thermal characteristics based on the current value of each installation year, a temperature increase was related to a current value, an installation year, and whether the contact unit is corroded. Insulation resistance began to decrease when a temperature increased to a certain level. With a lapse of installation year, the temperature at which insulation resistance began to decrease was lowered. This paper can be applicable for the survey data about electrical socket outlet induced fire accidents and management guidelines.

Fire Resistance Studies on High Strength Steel Structures

  • Wang, Wei-Yong;Xia, Yue;Li, Guo-Qiang
    • 국제초고층학회논문집
    • /
    • 제7권4호
    • /
    • pp.287-298
    • /
    • 2018
  • High strength steels have been widely applied in recent years due to high strength and good working performance. When subjected to fire conditions, the strength and elastic modulus of high strength steels deteriorate significantly and hence the load bearing capacity of structures reduces at elevated temperatures. The reduction factors of mechanical properties of high strength steels are quite different from mild steels. Therefore, the fire design methods deduced from mild steel structures are not applicable to high strength steel structures. In recent ten years, the first author of this paper has carried out a lot of fundamental research on fire behavior of high strength steels and structures. Summary of these research is presented in this paper, including mechanical properties of high strength steels at elevated temperature and after fire exposure, creep response of high strength steels at elevated temperature, residual stresses of welded high strength steel member after fire exposure, fire resistance of high strength steel columns, fire resistance of high strength steel beams, local buckling of high strength steel members, and residual strength of high strength steel columns after fire exposure. The results show that the mechanical properties of high strength steel in fire condition and the corresponding fire resistance of high strength steel structures are different from those of mild steel and structures, and the fire design methods recommended in current design codes are not applicable to high strength steel structures.

역기전력 추정 기반 SMPMSM 센서리스 드라이브에서 저항 오차가 대역폭에 미치는 영향 (Influence of Resistance Error to the Bandwidth of Back-EMF Estimation based SMPMSM Sensorless Drives)

  • 김재석;설승기
    • 전력전자학회논문지
    • /
    • 제21권5호
    • /
    • pp.418-426
    • /
    • 2016
  • This paper analyzes the effect of resistance error to the performance of sensorless drive system of surface-mounted permanent magnet synchronous machine (SMPMSM) based on the back-EMF observer. The analysis shows that the bandwidth of the entire sensorless drive system decreased in the low-speed region when using smaller resistance value than the actual one in the back-EMF observer. Even if the back-EMF observer invokes estimation error, the entire sensorless drive system does not make any steady-state position error. These characteristics may have positive effects such as extension of the low speed limit that goes further down in the sensorless drive. The validity of the analysis is verified by the experimental setup comprising the MG set.

The Analysis of Heat Transfer through the Multi-layered Wall of the Insulating Package

  • Choi, Seung-Jin
    • 한국포장학회지
    • /
    • 제12권1호
    • /
    • pp.45-53
    • /
    • 2006
  • Thermal insulation is used in a variety of applications to protect temperature sensitive products from thermal damage. Several factors affect the performance of insulation packages. Among these factors, the thermal resistance of the insulating wall is the most important factor to determine the performance of the insulating package. In many cases, insulating wall consists of multi-layered structure and the heat transfer through this structure is a very complex process. In this study, an one-dimensional mathematical model, which includes all of the heat transfer principles covering conduction, convection and radiation in multi-layered structure, were developed. Based on this model, several heat transfer phenomena occurred in the air space between the layer of the insulating wall were investigated. From the simulation results, it was observed that the heat transfer through the air space between the layer were dominated by conduction and radiation and the low emissivity of the surface of each solid layer of the wall can dramatically increase the thermal resistance of the wall. For practical use, an equation was derived for the calculation of the thermal resistance of a multi-layered wall.

  • PDF

무도장 내후성 강교량의 Box Girder 내부볼트 연결부에 대한 외부전원식 정기방식효과에 관한 연구 (A study on the effect of the external electric type corrosion resistance for the bolt connection in weathering steel box girders.)

  • 박용걸;김헌태;백찬호;최정열
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2004년도 추계학술대회 논문집
    • /
    • pp.988-993
    • /
    • 2004
  • This paper considers corrosion problems in the bolt connection of weathering steel box girder bridge using the external electric type corrosion resistance method which resisted to local corrosion in coated steel surface with contacted air. The weathering steel was created a rust itself in the passive state. but a coated box girder type was easily dew form could be made galvanic cell that accelerated corrosion. so that it was ruled by protection coat with some paint. Therefore, it needed that can be applied the external electric type corrosion resistance method in coated surface. As a result of the test of polarization amount had measured that the weathering steel was higher currents than the general steel by about $5\~10\%$. Therefore. an external electric type corrosion resistance method can be used to protect local corrosion in the coated bolt connection of weathering steel box girders effectively.

  • PDF

미지의 회전자 저항을 갖는 유도기의 적응 자속 관측자 설계 (An Adaptive Flux Observer of Induction Motors with Unknown Rotor Resistance)

  • 김도우;양해원;윤지섭;박병석;김홍필
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1998년도 추계학술대회 논문집 학회본부 B
    • /
    • pp.438-441
    • /
    • 1998
  • In this paper, we proposes an adaptive flux observer to estimate initial values of rotor fluxes and unknown rotor resistance. The error system between the model of induction motor and a proposed observer is devided as a fast subsystem and a slow one by a singular perturbation system. The fast subsystem is exponentially convergent on a boundary-layer. And the overall error system is reduced to a quasi-steady-state system. The adaptive law for an unknown rotor resistance is designed to stabilize the approximate error system. As computer simulation results show, the proposed adaptive flux observer estimates fast initial values of rotor fluxes and unknown rotor resistance.

  • PDF