• 제목/요약/키워드: on-site testing

검색결과 448건 처리시간 0.024초

A Study on the Application of NDT(Non-Destructive Testing) Techniques to the Unknown Bridge Foundations (미지의 교량기초에 대한 비파괴 시험기법(NDT)의 적용성에 관한 연구)

  • 채종훈;이원제;유재명;이우진
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 한국지반공학회 2000년도 봄 학술발표회 논문집
    • /
    • pp.317-324
    • /
    • 2000
  • In this study, ten drilled shafts were constructed for evaluating the application of NDT(Non-Destructive Testing) techniques. The drilled shafts, 0.4 m in diameter and 7.0 m in length, were constructed at Namyangju site in Namyangju City. One of the shafts was constructed with no defect, and the other shafts were constructed with the defects of soft bottom, necking, bulging, cave-in and/or weak concrete. Then, these techniques were applied to the bridge foundations for studying unknown bridge foundation characteristics.

  • PDF

A Study for Testing Conditions of Microtox Toxicity Test to the Quality of Sediment in Domestic Rivers (국내 하천 퇴적물 건강성평가를 위한 Microtox 독성시험 조건확립 연구)

  • 정홍배;박정규;문성환;류태권;김소정;배철한;황인영
    • Environmental Analysis Health and Toxicology
    • /
    • 제16권4호
    • /
    • pp.143-151
    • /
    • 2001
  • Six rivers were selected as preliminary screening sites to determine the test conditions of Microtox in assessing the toxicity of the sediment. In addition, a pH range of 6.0∼6.5 was established in testing pore water, aqueous extracts and organic extracts. Each extractable fraction of sediment showed different toxicities. Therefore, in order to properly examine the toxicity in the sediment, all extractable fractions of sediment samples needed to be tested with Microtox. Thus, sediment samples were additionally collected from at least 4 secondary sites within 50∼100m area of the primary sampling site to reduce any variation or deviation in toxicity assessment. From all sediment toxicity data that was collected from this study, it was concluded that the Keumho river was the most polluted with the highest sediment toxicity of all the rivers analyzed and needed further detailed research on its pollution problem.

  • PDF

Development of Eddy Current Technique for Reactor In-Core Flux Thimble Wear (원자로 In-Core Flux Thimble 결함의 와전류 탐상 기술 개발)

  • Park, S.S.;Jang, Y.Y.;Yim, C.Y.;Park, K.H.
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • 제10권2호
    • /
    • pp.15-22
    • /
    • 1990
  • Since in-core flux thimble tube wear the due to flow-induced vibration could degrade the integrity of nuclear reactor, the effective detection and interpretation of the wear is important. In order to establish an inspection technique for thimble tubes, an eddy current experiment was performed to determine the optimum test frequency, defect sensitivity and evaluation accuracy. Eddy current probes were designed and fabricated with a theory. Specimens with artificial defects were fabricated using electro discharge machining method. The results from inspection technique developed and on-site inspection showed good applicability.

  • PDF

Hereditary cancer and genetic counseling (유전성 암과 유전상담)

  • Jeong, Seung-Yong
    • Journal of Genetic Medicine
    • /
    • 제4권1호
    • /
    • pp.15-21
    • /
    • 2007
  • Hereditary syndromes cause approximately 5 to 10% of overall cancer cases. Cancer related with genetic syndromes are found elsewhere, including stomach, breast, colorectum, ovary, brain and so on. Because hereditary cancers are due to germline mutations, these patients have unique clinical features distinct from sporadic cancer. Generally these features include (i) early age-of onset of cancer, (ii) frequent association with synchronous or metachronous tumors, (iii) frequent bilateral involvement in paired organs (iv) frequent association with other site tumors or characteristic clinical manifestation specific to each genetic syndrome. Due to these differences, the management strategy for patients with hereditary cancer is quite different from that for sporadic cancer. Additionally, there are important screening and surveillance implications for family members. Genetic counselling is prerequisite to these families for risk assessment by pedigree analysis, and guidance to clinical or genetic testing. The genes responsible for these syndromes has recently identified, as a result, genetic testing has become important determining factor in clinical decisions.

  • PDF

A New Multi-site Test for System-on-Chip Using Multi-site Star Test Architecture

  • Han, Dongkwan;Lee, Yong;Kang, Sungho
    • ETRI Journal
    • /
    • 제36권2호
    • /
    • pp.293-300
    • /
    • 2014
  • As the system-on-chip (SoC) design becomes more complex, the test costs are increasing. One of the main obstacles of a test cost reduction is the limited number of test channels of the ATE while the number of pins in the design increases. To overcome this problem, a new test architecture using a channel sharing compliant with IEEE Standard 1149.1 and 1500 is proposed. It can significantly reduce the pin count for testing a SoC design. The test input data is transmitted using a test access mechanism composed of only input pins. A single test data output pin is used to measure the sink values. The experimental results show that the proposed architecture not only increases the number of sites to be tested simultaneously, but also reduces the test time. In addition, the yield loss owing to the proven contact problems can be reduced. Using the new architecture, it is possible to achieve a large test time and cost reduction for complex SoC designs with negligible design and test overheads.

Fluorescence Characteristic Spectra of Domestic Fuel Products through Laser Induced Fluorescence Detection

  • Wu, Ting-Nien;Chang, Shui-Ping;Tsai, Wen-Hsien;Lin, Cian-Yi
    • Journal of Soil and Groundwater Environment
    • /
    • 제19권5호
    • /
    • pp.18-25
    • /
    • 2014
  • Traditional investigation procedures of soil and groundwater contamination are followed by soil gas sampling, soil sampling, groundwater sampling, establishment of monitoring wells, and groundwater monitoring. It often takes several weeks to obtain the analysis reports, and sometimes, it needs supplemental sampling and analysis to delineate the polluted area. Laser induced fluorescence (LIF) system is designed for the detection of free-phase petroleum pollutants, and it is suitable for on-site real-time site investigation when coupling with a direct push testing tool. Petroleum products always contain polycyclic aromatic hydrocarbon (PAH) compounds possessing fluorescence characteristics that make them detectable through LIF detection. In this study, LIF spectroscopy of 5 major fuel products was conducted to establish the databank of LIF fluorescence characteristic spectra, including gasoline, diesel, jet fuel, marine fuel and low-sulfur fuel. Multivariate statistical tools were also applied to distinguish LIF fluorescence characteristic spectra among the mixtures of selected fuel products. This study successfully demonstrated the feasibility of identifying fuel species based on LIF characteristic fluorescence spectra, also LIF seemed to be uncovered its powerful ability of tracing underground petroleum leakages.

Understanding the Degradative Effects of Different Climatological Conditions on Architectural Coatings: Progress Report on Korea Institute of Construction Materials Site Comparison Study of Seosan (Korea) Outdoor Exposure Testing Facility

  • Choi, Yoon;Pyo, Soonjin;Seo, Junsik;Yang, Inmo;Kim, Seungjin;Kim, Sangmyoung
    • Corrosion Science and Technology
    • /
    • 제8권3호
    • /
    • pp.116-118
    • /
    • 2009
  • Korea Institute of Construction Materials founded Seosan Outdoor Exposure Test Site 2005 at Korea, which is a part of Worldwide Exposure Network (WEN). To evaluate the test site along with other exposure test sites, three different types of paints have been under real time weathering conditions at three major weathering test facilities around the world. Using these test specimens several spectroscopic experiments along with physical tests have been performed. Also acceleration tests have been performed using the same paints. The correlation of weathered paints among three different test facilities and accelerated test results has been compared. From the results the reliability of Seosan Weathering Test Facility and reasonable life time prediction tests are discussed.

Research on the Operation of Safeguards Equipment in Extreme Environmental Conditions (극한 환경 내 안전조치 장비 운영에 관한 연구)

  • Jiyoung Han;Suhui Park;Jewan Park;Yongmin Kim
    • Journal of the Korean Society of Radiology
    • /
    • 제17권7호
    • /
    • pp.1189-1195
    • /
    • 2023
  • In scenarios involving inspections and verifications of nuclear facilities, ensuring the proper functioning of on-site safeguards equipment is crucial. There have been precedents in Kazakhstan where equipment failed to operate properly due to extremly cold temperatures, and the year-round minimum temperature at North Korea's Punggye-ri nuclear test site is approximately minus 30 degrees Celsius. To ensure the proper functioning of equipment in extreme environments for on-site verification of nuclear activities on the Korean Peninsula, relevant research is necessary. This includes confirming the functionality of equipment used in inspections and verifications, as well as analyzing factors that may disrupt their normal operation. This study aims to conduct a risk analysis for the normal operation of equipment in extreme environments and develop criteria and procedures for environmental-based performance testing. To achieve this, we conducted a risk analysis based on IAEA safeguards, analyzed the utilization of equipment, and performed a risk analysis associated with transportation for on-site verification considering the environmental characteristics of the Korean Peninsula. Furthermore, we provided performance testing criteria and procedures. The research results can be utilized as reference material in the verification and monitoring processes of nuclear activities.

A study on the Site Survey and Detection Efficiency for Kepco Lightning Detection and Information Network (낙뢰측정 네트워크(KLDNet)를 위한 감지기 사이트서베이와 낙뢰 감지율 검토)

  • Woo, J.W.;Kwak, J.S.;Moon, J.D.
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • 제55권11호
    • /
    • pp.532-537
    • /
    • 2006
  • Lightning induced faults accounts for more than 66% at the transmission lines of KEPCO. The lightning causes damages to power system equipments including transmission line, the blackout of electricity and the electro-magnetic interference. Because of this reason, we need the real time lightning information for the optimal operation of power system. And, it is required to obtain and accumulate the lightning current parameters for the insulation design. In 2005, KEPRI constructed a lightning detection network, the KLDNet (i.e. Kepco Lightning Detection & Information System) and launched a lightning information service for KEPCO customers. It is intended to provide data service on the operation of transmission lines and collect lightning-related data, which is the most important factor regulating power system design and operation. The new system will replace LPATS, the old detection system, which has been operating since 1995 and is rapidly failing in terms of both detection performance and location accuracy. The purpose of this paper is to explain the work performed and the results of that work in performing a site survey of several locations. The purpose of the site survey is to find locations acceptable for the installation of a lightning location receiver in support of a Lightning detection system(LDS). A restriction was placed on the surveyed locations, as they must belong to the Korea Electric Power Company. This requirement was made to facilitate the communication needs of the LDS network. Total of 15 sites were evaluated as possible LDS sensor sites. Some of the sites were rejected for physical reasons and therefore no electrical testing was performed. Of the 15 sites, total of 10 sites were considered acceptable and 5 sites were rejected for various reason. In this paper, we would like to explain the site survey and detection efficiency for LDS.

3-Dimensional Imaging of Shear Wave Velocity in the Soil Site using HWAW Method (HWAW방법을 이용한 지반의 전단파 속도 3-D 영상화)

  • Park, Hyung-Choon;Hwang, Hea-Jin;Cho, Sung-Eun
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 한국지반공학회 2010년도 춘계 학술발표회
    • /
    • pp.176-181
    • /
    • 2010
  • The evaluation of shear modulus (or shear wave velocity) profile of the site is very important in various fields of geotechnical engineering. In the field, there exist spatial variations of shear modulus that case uncertainty in the geotechnical analysis or design. So it is necessary to evaluate the spatial variation of shear wave velocities of the soil site. In this study, the HWAW method is applied to the determination of a 3-D Vs map of soil site. The HWAW method, which is based on harmonic wavelet transforms, has been developed to determine phase and group velocities of waves. The HWAW method uses only the signal portion of the maximum local signal/noise ratio to evaluate the phase velocity in order to minimize the effect of the noise. The field testing of this method is relatively simple and fast because only one experimental setup, which consists of one pair of receivers on the surface, is needed using a short receiver spacing setup (1~3m). These characteristics make it possible to determine detailed local Vs profile in the site with lateral Vs variation and to evaluate 3-D Vs map by performing a series of tests on the grid. To estimate the applicability of the proposed method, field tests were performed. Through field applications validity and applicability of the proposed method were verified.

  • PDF