• 제목/요약/키워드: on-off control

검색결과 2,539건 처리시간 0.031초

고전압 차단기용 솔레노이드 액추에이터의 거동 (Behavior of the Solenoid Actuator for High-Voltage Circuit Breaker)

  • 윤소남;함영복;안병규;김고도
    • 유공압시스템학회논문집
    • /
    • 제1권3호
    • /
    • pp.1-6
    • /
    • 2004
  • In the last few years, a considerable number of studies have been made on On-Off solenoid for fluid control. But, only few attempts have so far been made at solenoid actuator for high-voltage circuit breaker. In case of the high-pressure and high-flow system like high-voltage circuit breaker, a big size of On/Off solenoid is necessary which size is proportional to control pressure and flow rate. So, it is non-effective in the view point of system optimization. In this paper, On/Off solenoid actuator with the farce amplifier connected to the solenoid rod was proposed to get a high mechanical force and a fast response time. The magnetic force and the mechanical stress distributions were analysed using finite element analysis. The performances of suggested solenoid actuator were evaluated through the experimental results and compared with the analysis results.

  • PDF

군간부 숙소에 적용된 중용량 및 멀티 보일러 시스템의 난방 및 급탕에너지 비교 (Heating and Hot Water Supply Energy Comparison of Medium Capacity and Multi Boilers System applied to Military Officer Housing)

  • 김민용;김영일;정광섭
    • 한국지열·수열에너지학회논문집
    • /
    • 제10권3호
    • /
    • pp.8-16
    • /
    • 2014
  • Heating and hot water supply energy consumption of medium and multi boiler systems applied to military officer housing are compared with in-situ experiment and TRNSYS dynamic simulation program. In a multiple boiler system, small capacity boilers are connected in parallel to meet the required capacity. For handling partial loads, medium capacity boiler relies on on-off control, while multi boiler adopts PI control. Since multi boiler has higher efficiency and better control strategy, the results show that energy consumption can be reduced significantly with the multi boiler system.

엑티브 머플러를 이용한 실차 배기 소음 저감에 관한 연구 (A study on the exhaust noise reduction of automobile with the active muffler)

  • 홍진석;신준;김흥섭;송진호;오재응
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 1996년도 추계학술대회 논문집
    • /
    • pp.283-287
    • /
    • 1996
  • The exhaust noise reduction of automobile with the active muffler is experimentally investigated. The control algorithm is the filtered-x LMS algorithm and the inverse algorithm with the adaptive line enhancer. Also, the control efficiency is increased with synthesized second harmonic engine frequency. In the experiment, the active muffler is applied to the end of exhaust system in automobile and the control with on-line secondary path modeling method(inverse algorithm) is compared the control of off-line secondary path modeling method. As secondary path transfer functions are changed, the experimental results show that the control performance with on-line method is more efficient than that with off-line method in the exhaust noise reduction of automobile.

  • PDF

지능형 도로 LED 라인조명 시스템 (LED Line Lamp System for Intelligent Road)

  • 양진영;김원식;김진희;박찬원
    • 산업기술연구
    • /
    • 제29권B호
    • /
    • pp.133-137
    • /
    • 2009
  • This paper presents the development of smart road line lamp system consisting light control device. It can perform the individual power control or partial on/off control of a LED lamp by control center and can detect the error of the LEDs by current sensing. Also, the ability to control the brightness and period of on/off by detecting the car's existence. This light control circuit consists of road line lamp unit device. It can give a lot of solutions when the server, which controls the whole system, is operated through CDMA(Code-Division Multiple Access) network.

  • PDF

Intelligent Switching Control of Pneumatic Cylinders by Learning Vector Quantization Neural Network

  • Ahn KyoungKwan;Lee ByungRyong
    • Journal of Mechanical Science and Technology
    • /
    • 제19권2호
    • /
    • pp.529-539
    • /
    • 2005
  • The development of a fast, accurate, and inexpensive position-controlled pneumatic actuator that may be applied to various practical positioning applications with various external loads is described in this paper. A novel modified pulse-width modulation (MPWM) valve pulsing algorithm allows on/off solenoid valves to be used in place of costly servo valves. A comparison between the system response of the standard PWM technique and that of the modified PWM technique shows that the performance of the proposed technique was significantly increased. A state-feedback controller with position, velocity and acceleration feedback was successfully implemented as a continuous controller. A switching algorithm for control parameters using a learning vector quantization neural network (LVQNN) has newly proposed, which classifies the external load of the pneumatic actuator. The effectiveness of this proposed control algorithm with smooth switching control has been demonstrated through experiments with various external loads.

맨체스터 코드의 부반송파 변조를 이용한 가시광통신의 조명제어 (Dimming Control in Visible Light Communication Using Subcarrier Modulation of Manchester Code)

  • 이성호
    • 센서학회지
    • /
    • 제28권3호
    • /
    • pp.191-197
    • /
    • 2019
  • In this study, we propose a dimming control method for a visible light communication (VLC) system, in which the subcarrier on-off keying (OOK) modulation of Manchester code is used for data transmission. In the VLC transmitter, non-return-to-zero (NRZ) code data is transformed to Manchester code, which is OOK modulated with a subcarrier. Manchester code is used for flicker-free lighting; the duty factor is changed for dimming control, and the subcarrier is used for preventing the adjacent noise light interference. In the experiments, the dimming control was carried out from about 8%-92% of the continuous wave (CW) LED light. This configuration is simple and effective in constructing a VLC system for indoor wireless sensor networks with flicker-free illumination and dimming control capability without adjacent noise light interference.

Chattering에 의한 위성 탑재체 지향성능저하 최소화를 위한 반능동제어기법 성능분석 (Performance Investigation of Semi-Active Control Logic to Minimize a Pointing Performance Degradation of On-Board Payload by Chattering Effects)

  • 오현웅;최영준
    • 한국항공우주학회지
    • /
    • 제38권9호
    • /
    • pp.882-889
    • /
    • 2010
  • 수동형 진동제어 방식과 같이 시스템이 안정되며, 수동형에 비해 높은 제진 효과가 기대되는 반능동 진동제어 방식은 시스템의 안정화가 요구되는 우주구조물의 제진방법에 유효한 진동제어 방식중 하나이다. On-Off 제어방식에 근거한 반능동 제어는 On-Off 스위칭 시에 전달력의 불연속성으로 인한 chattering을 발생시킬 수 있으며, 이는 탑재체 구조물의 고유진동수와의 커플링으로 인하여 지향성능을 저하시키는 원인으로 작용할 수 있다. 본 논문에서는 chattering 영향 최소화를 통한 지향성능향상을 목적으로 LQ(Linear Quadratic)이론에 기반한 가변 감쇠형 반능동 제어기법을 제안하였다. 시뮬레이션 결과는 본 논문에서 제안한 반능동 제어기법은 기존의 skyhook와 LQ를 기반으로 하는 Bang-Bang 반능동 제어기법과 비교하여 높은 진동절연 성능을 나타내고 있다.

디지털 제어 기반의 경계점모드 브릿지리스 PFC 컨버터 (Critical Conduction Mode Bridgeless PFC Converter Based on a Digital Control)

  • 김태훈;이우철
    • 전기학회논문지
    • /
    • 제65권12호
    • /
    • pp.2000-2007
    • /
    • 2016
  • Generally, in order to implement the CRM(Critical Conduction Mode), the analog controller is used rather than a digital controller because the control is simple and uses less power. However, according to the semiconductor technology development and various user needs, digital control system based on a DSP is on the rise. Therefore, in this paper, the CRM bridgeless PFC converter based on a digital control is proposed. It is necessary to detect the inductor current when it reaches zero and peak value, for calculating the on time and off time by using the current information. However, in this paper, the on-time and off-time are calculated by using the proposed algorithm without any current information. If the switching-times are calculated through the steady-state analysis of the converter, they do not reflect transient status such as starting-up. Therefore, the calculated frequency is out of range, and the transient current is generated. In order to solve these problems, limitation method of the on-time and off-time is used, and the limitation values are varied according to the voltage reference. In addition, in steady state, depending on the switching frequency, the inductance is varied because of the resonance between the inductor and the parasitic capacitance of the switching elements. In order to solve the problem, inductance are measured depending on the switching frequency. The measured inductance are used to calculate the switching time for preventing the transient current. Simulation and experimental results are presented to verify the proposed method.

주기적 외란의 제거를 위한 빠른 오프라인 학습 제어 (A Fast Off-line Learning Approach to the Rejection of Periodic Disturbances)

  • 장정국;김남국;이호성
    • 정보저장시스템학회논문집
    • /
    • 제3권4호
    • /
    • pp.167-172
    • /
    • 2007
  • The recently-developed off-line learning control approaches for the rejection of periodic disturbances utilize the specific property that the learning system tends to oscillate in steady state. Unfortunately, the prior works have not clarified how closely the learning system should approach the steady state to achieve the rejection of periodic disturbances to satisfactory level. In this paper, we address this issue extensively for the class of linear systems. We also attempt to remove the effect of other aperiodic disturbances on the rejection of the periodic disturbances effectively. In fact, the proposed learning control algorithm can provide very fast convergence performance in the presence of aperiodic disturbance. The effectiveness and practicality of our work is demonstrated through mathematical performance analysis as well as various simulation results.

  • PDF