• 제목/요약/키워드: on-off control

검색결과 2,539건 처리시간 0.028초

다양한 형태의 조명(형광등) 전력제어 실증시험을 통한 비용효과적인 전력수요관리방법 도출 (A Study on the Cost Effective DSM Method for Lighting Power Control through Pilot Test Based on Pre-Verified Methodologies)

  • 양승권;김대영
    • 조명전기설비학회논문지
    • /
    • 제27권2호
    • /
    • pp.7-13
    • /
    • 2013
  • The portion of lighting power consumption for our country is up to 20~30% of the total amount. Currently, most of the DSM(Demand side management) of lighting power is delivered in supply of high efficient lighting to customers. On the contrary, applications of lighting power to power load leveling are still rare. In this paper, the simulations for various control types of lighting power for load leveling are tried, and we obtained the cost effective and optimal control method through that. This simulation was executed in test office with fluorescent light by us based on applying 8 control types(on, off & dimming), considering customers' satisfaction, for instance, minimum intensity of illumination allowed. According to the result of this test, we found that mixed type(chessboard(on-off) plus dimming control(10%)) is most effective.

Low Level Control of Metal Belt CVT Considering Shift Dynamics and Ratio Valve On-Off Characteristics

  • Kim, Tal-Chol;Kim, Hyun-Soo
    • Journal of Mechanical Science and Technology
    • /
    • 제14권6호
    • /
    • pp.645-654
    • /
    • 2000
  • In this paper, low level control algorithms of a metal belt CVT are suggested. A feedforward PID control algorithm is adopted for line pressure based on a steady state relationship between the input duty and the line pressure. Experimental results show that feedforward PID control of the line pressure guarantees a fast response while reducing the pressure undershoot which may result in belt slip. For ratio control, a fuzzy logic is suggested by considering the CVT shift dynamics and on-off characteristics of the ratio control valve. It is found from experimental results that a desired speed ratio can be achieved at steady state in spite of the fluctuating primary pressure. It is expected that the low level control algorithms for the line pressure and speed ratio suggested in this study can be implemented in a prototype CVT.

  • PDF

유압 위치제어 시스템의 단속적 제어방법에 관한 연구 I

  • 장효환;안병홍;이춘호
    • 대한기계학회논문집
    • /
    • 제11권3호
    • /
    • pp.465-472
    • /
    • 1987
  • 본 연구에서는 솔레노이드 밸브를 사용한 유압위치제어 시스템에 위에서 언급 한 두가지 단속적 제어 방법을 적용하여 각각의 제어변수들과 부하조건이 시스템의 시 간 영역에서의 응답특성에 미치는 영향을 실험적으로 규명하고 각각의 제어특성을 비 교 고찰하였다.

고온가스 및 액체 바이패스 적용 용량가변 히트펌프의 성능특성에 관한 실험적 연구 (An Experimental Study on the Performance Characteristics of Hot-gas and Liquid Bypass Heat Pump Systems for Capacity Modulation)

  • 안재환;주영주;윤원재;강훈;김용찬
    • 설비공학논문집
    • /
    • 제25권3호
    • /
    • pp.137-142
    • /
    • 2013
  • A small air-conditioner or chiller for a constant temperature bath normally uses a constant speed compressor. The constant speed compressor is relatively inexpensive, but it uses on/off control for capacity modulation. The on/off control has several disadvantages, specifically energy loss and large temperature fluctuation. Continuous operation with a bypass system can be an alternative to on/off control, for capacity modulation. In this study, a heat pump system having a hot-gas bypass and a liquid bypass was adopted. The performance of the bypass-type heat pump was measured, by varying the bypass valve opening. The differences of the COP between the hot-gas bypass and the liquid bypass, in the cooling and heating operations, were within 2% and 1%, respectively. The liquid bypass showed a wider range of capacity control in the cooling operation but the hot-gas bypass showed a wider range of capacity control in the heating operation.

선박 비상조명 전원장치의 다중 원격제어 (Multi Remote Control of Ship's Emergency Lighting Power Supply)

  • 이성근;임현정
    • 한국항해항만학회지
    • /
    • 제29권10호
    • /
    • pp.859-863
    • /
    • 2005
  • 본 논문은 광범위한 전력제어가 가능하고, PC 직렬통신 방식에 의해 원거리에서 시스템을 ON-OFF할 수 있으며, 시스템의 상태를 모니터링 할 수 있는 선박비상조명시스템의 전력제어특성 개선에 관해 연구한다. 제안된 시스템은 강압형 컨버터, 비상급전회로, 반 브리지 인버터, 형광램프기동회로, 마이크로프로세서 제어 및 멀티통신회로 등으로 구성된다. 실험을 통하여 과전류에 의한 해당 시스템의 정지와 주전원 차단시의 비상전원에 의한 신속한 급전을 확인할 수 있고, 입력전력은 35[$\%$] 범위까지 제어됨을 확인한다. 또한, 원거리에서 원하는 시스템을 ON-OFF 하고, 시스템의 전력, 전압, 전류, 배터리 전압 등의 모니터링도 한다.

온수난방시스템 온실의 온도제어 시뮬레이션 (A Simulation of Temperature Control of Greenhouse with Hot-Water Heating System)

  • 정태상;하종규;민영봉
    • 생물환경조절학회지
    • /
    • 제8권3호
    • /
    • pp.152-163
    • /
    • 1999
  • 온수난방시스템 온실의 디지털 온도제어 수식모형을 수립하고, 이 수식모형을 이용하여 제어시뮬레이션을 실시하여 최적의 온도제어 방법을 구명하였다. 이용된 제어기법은 종래의 온수온도 일정 공급ON-OFF 제어, 비례제어, PI 제어, PID 제어기법이었으며, 시뮬레이션을 이용해 제어기법별 제어성능을 비교 분석하였다. 대상유리온실의 실내온도( T$_{i}$ )에 관한 디지털 제어수식모형은 공급온수온도( T$_{w}$ )와 외기온도( T$_{o}$ )가 관련된 T$_{i}$($textsc{k}$+1)= 0.851.T$_{i}$($textsc{k}$)+0.055.T$_{w}$($textsc{k}$)+0.094.T$_{o}$ ($textsc{k}$)로 나타났다. 온실의 실내온도제어 시뮬레이션을 실시한 결과 종래의 온수온도 일정공급 ON-OFF 제어, P 제어, PI 제어,PID 제어의 정정시간, 오버슛트, 정상오차는 각각 무한, 3.5$0^{\circ}C$, 3.5$0^{\circ}C$ / 30분, 2.37$^{\circ}C$, 0.51$^{\circ}C$ / 21분, 0.0$0^{\circ}C$, 0.23$^{\circ}C$ / 18분, 0.0$0^{\circ}C$, 0.23$^{\circ}C$로 나타났으며, 온수난방시스템 온실의 온도제어에 가장 적합한 제어기법은 PI와 PID제어인 것으로 나타났다 또한 미분이득은 온실의 난방계에 거의 영향을 미치지 않지만 적분이득은 큰 영향을 미치는 것으로 나타났다. 나타났다.

  • PDF

퍼지제어기를 이용한 제작공정에서의 경사장력제어 (A Fuzzy Controller for Warp Tension Control in The Weaving Process)

  • 류도훈;이연정
    • 한국지능시스템학회:학술대회논문집
    • /
    • 한국퍼지및지능시스템학회 2000년도 추계학술대회 학술발표 논문집
    • /
    • pp.335-339
    • /
    • 2000
  • In the weaving process, tension control of the warp is important. The variation of the warp tension cause irregularities of the weft density and low quality of the woven fabrics. Due to the fact that the warp tension varies in depending on the difference between take-up velocity and let-off velocity, it is necessary to regulate the velocity of let-off in relation to that of take-up for keeping the warp tension. Futhermore, the diameter of warp beam changes in the weaving process. The changing diameter of warp beam cause changing inertia of warp beam and the velocity of the let-off. It makes the control of such a system more complex. In this paper, we propose a fuzzy controller for the warp tension control. From the computer simulation, it was observed that a developed fuzzy controller has a better performance than that of conventional PI controller.

  • PDF

강판으로 보강된 RC보의 조기파괴제어에 관한 실헙적 연구 (A Experimental Study on the Control of Premature Failure of RC Beams strengthened by Steel Plates)

  • 심종성;한만엽;김규선;이인범
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 1998년도 봄 학술발표회논문집(II)
    • /
    • pp.585-591
    • /
    • 1998
  • In the case of reinforced concrete beams strengthening by steel plate, sometimes these beams collapse due to the stress concentration at the ends of steel plates before the design expected failure. This kind of failure is called premature failure. This study analyzes the behavior of strengthened RC beams to control premature failure of these plated beams with either changing the geometries at the ends of plates or strengthening steel plates beside the ends. The results from the former cases show that, the effect of expanded plates sections at the ends was very small, and the beams which are rounded the ends of plates effectively increased the initial rip-off loads about 14% compared with control beam but the ultimate loads was almost same. However, the beams in the latter cases effectively increased the initial and the ultimate rip-off loads with changing failure mode, especially around 14~19% in the ultimate rip-off load comparing with control beam.

  • PDF

고전력밀도 AC/DC Adapter를 위한 off-time 제어법 (Off-time control method for high power density AC/DC Adapter)

  • 강신호;장준호;홍성수;이준영
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2007년도 하계학술대회 논문집
    • /
    • pp.286-288
    • /
    • 2007
  • The proposed method offers an improved control method for high power density AC/DC adapter by using more energy efficient electrical equipments. Power factor corrector (PFC) topology is based on boost topology with boundary conduction mode (BCM). DC/DC topology is based on half-bridge topology with newly introduced off-time control method, which helps to reduce size of the semiconductor and the magnetic devices. Test results with 85W AC/DC adapter (18.5V/4.6A) design shows that the measured efficiency is 90% with power density of $36W/in^3$. It also show low no load power consumption of about 0.5W.

  • PDF

Filtered Velocity Feedback 제어기를 이용한 양단지지보의 능동진동제어 (Active Vibration Control of Clamped Beams Using Filtered Velocity Feedback Controllers)

  • 신창주;홍진숙;정의봉
    • 한국소음진동공학회논문집
    • /
    • 제21권5호
    • /
    • pp.447-454
    • /
    • 2011
  • This paper reports a filtered velocity feedback(FVF) controller, which is an alternative to direct velocity feedback(DVFB) controller. The instability problems due to high frequency response under DVFB can be alleviated by the suggested FVF controller. The FVF controller is designed to filter out the unstable high frequency response. The FVF controller and the dynamics of clamped beams under forces and moments are first formulated. The effects of the design parameters(cut-off frequency, gain, and damping ratio) on the stability and the performance are then investigated. The cut-off frequency should be selected not to affect the system stability. The magnitude of the open loop transfer function(OLTF) at the cut-off frequency should be small. As increasing the gain of the FVF controller, the magnitude of the OLTF is increased, so that the closed loop response can be reduced more. The enhancement of the OLTF at the cut-off frequency is reduced but the phase behavior around the cut-off frequency is distorted, as the damping ratio is increased. The control performance is finally estimated for the clamped beam. More than 10 dB reductions in velocity response can be achieved at the modal frequencies from the first to eighth modes.