• Title/Summary/Keyword: on-line measurement

Search Result 1,874, Processing Time 0.037 seconds

Improved spectral line measurements of the SDSS galaxy spectra

  • Oh, Kyu-Seok;Sarzi, Marc;Yi, Suk-Young
    • Bulletin of the Korean Space Science Society
    • /
    • 2009.10a
    • /
    • pp.35.1-35.1
    • /
    • 2009
  • We have established a database of galaxy spectral line strengths for the SDSS database using an improved line measuring method. Our work includes the entire SDSS DR7 galaxies within redshift of 0.2. The absorption line strengths measured by the SDSS pipeline are seriously contaminated by emission filling. Our code, GANDALF (gas and absorption line fitting code) performs more accurate measurements by effectively separating emission lines from absorption lines. A significant improvement has also been made on the velocity dispersion measurement, more notably in late-type galaxies. We have also identified a number of broad line region galaxies which were misclassified as normal galaxies by the SDSS pipeline. We developed an effective method measuring their line strengths. The database will be provided with new parameters that are indicative of the line strength measurement quality. In addition, we made galaxy templates for the Hubble sequence. The database will be useful for many fields of galaxy studies including star formation and AGN activities.

  • PDF

Characteristics Analysis of On-Line Partial Discharge Measurement Sensor for Insulation Diagnosis of HV Rotating Machines (고압 회전기의 절연열화 진단을 위한 운전중 부분방전 측정 센서의 특성분석)

  • Yoon, Dae-Hee;Hwang, Don-Ha;Kim, Yong-Joo;Lee, Kwang-Sik;Kim, Hee-Dong;Kim, Jeong-Woo
    • Proceedings of the KIEE Conference
    • /
    • 2000.07c
    • /
    • pp.1909-1911
    • /
    • 2000
  • Recently many research activities on the diagnosis of stator winding insulation of large rotating machines have been reported. Capacitive couplers are widely used as sensors for on-line partial discharge (PD) measurement of high voltage rotating machines. This paper presents laboratory test to compare Stator Slot Coupler (SSC), Resistance Temperature Detector (RTD), 80 [pF] coupler and 500 [pF] coupler for on-line PD measurement of rotating machines.

  • PDF

MEASUREMENT OF NUCLEAR FUEL ROD DEFORMATION USING AN IMAGE PROCESSING TECHNIQUE

  • Cho, Jai-Wan;Choi, Young-Soo;Jeong, Kyung-Min;Shin, Jung-Cheol
    • Nuclear Engineering and Technology
    • /
    • v.43 no.2
    • /
    • pp.133-140
    • /
    • 2011
  • In this paper, a deformation measurement technology for nuclear fuel rods is proposed. The deformation measurement system includes a high-definition CMOS image sensor, a lens, a semiconductor laser line beam marker, and optical and mechanical accessories. The basic idea of the proposed deformation measurement system is to illuminate the outer surface of a fuel rod with a collimated laser line beam at an angle of 45 degrees or higher. For this method, it is assumed that a nuclear fuel rod and the optical axis of the image sensor for observing the rod are vertically composed. The relative motion of the fuel rod in the horizontal direction causes the illuminated laser line beam to move vertically along the surface of the fuel rod. The resulting change of the laser line beam position on the surface of the fuel rod is imaged as a parabolic beam in the high-definition CMOS image sensor. An ellipse model is then extracted from the parabolic beam pattern. The center coordinates of the ellipse model are taken as the feature of the deformed fuel rod. The vertical offset of the feature point of the nuclear fuel rod is derived based on the displacement of the offset in the horizontal direction. Based on the experimental results for a nuclear fuel rod sample with a formation of surface crud, an inspection resolution of 50 ${\mu}m$ is achieved using the proposed method. In terms of the degree of precision, this inspection resolution is an improvement of more than 300% from a 150 ${\mu}m$ resolution, which is the conventional measurement criteria required for the deformation of neutron irradiated fuel rods.

Measurement of Indoor Power Line Channel Characteristics Considering Capacitive Loads (용량성 부하를 고려한 옥내 전력선 채널 특성 측정)

  • Heo Yoon-Seok;Hong Bong-Hwa;Kim Chul;Jun Kye-Suk;Lee Dae-Young
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.42 no.6 s.336
    • /
    • pp.53-60
    • /
    • 2005
  • Considerable efforts has been recently devoted to the determination of accurate channel models for the power line environment, both for the indoor and outdoor cases. The common limitation of the known and previously published models is the particular type of approach followed. This paper is concerned with a power line channel characteristic measurement for the more fast and efficiently power line communication experiment. The need arises from the fact that indoor power cables consist of conductors and inductors. A capacitive load simulator is a essential equipment in the power line modem development for indoor power line network. We accomplished a channel data base by the frequency response method about the total 224 capacitor load cases. On the basis of this measurement modeling it is here revealed that the power line communication channel is a more deterministic media.

A STUDY ON USEFULNESS OF THE REFERENCE LINE IN DIAGNOSIS OF THE FACIAL ASYMMETRY (안모비대칭의 진단용 기준선의 유용성에 관한 연구)

  • Ryu, Sung-Ho;Chang, Hyun-Ho
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.31 no.3
    • /
    • pp.266-273
    • /
    • 2005
  • Purpose: To assess the relationship between soft tissue reference line and hard tissue reference line using the standardized photographs and the posteroanterior cephalometric radiographs(P-A)in facial asymmetric patients and to compare the differences of angular measurement between normal group and asymmetry group. Methods: Normal group consisted of 44 persons with normal occlusion and normal facial morphology. Asymmetry group consisted of 90 patients with facial asymmetry. Standardized facial photographs and P-A were taken in all subjects. The horizontal reference lines were bipupillary line in photographs and latero-orbitale line in P-A respectively. The vertical reference line were the line from the midpoint of horizontal reference line perpendicularly. Angular measurement of otobasion canting, lip canting, nose deviation, chin deviation, and maxillary deviation were compared and analyzed in photographs. And angular measurement of mastoid canting, mandibular canting, nose deviation, chin deviation, and maxillary deviation were compared and analyzed in P-A. Results: 1. The variables of photographs and P-A were significantly related in the asymmetry group. 2. Significant differences between all variables except for PT2 and PA2 were shown in the asymmetry group and between PT1 and PA1, PT3 and PA3 in the normal group respectively. 3. Comparison measurement scores of angular difference between control group and experimental group concerning each variable showed significant difference except for PA1. Conclusions: Soft tissue components may not compensate for underlying skeletal imbalance in nose deviation and chin deviation. The horizontal reference lines in photographs were significant related with the P-A, but angular variables between the two studies show significant differences. Therefore, we do not recommend use photography in the assessment the facial asymmetry as complemented in the P-A.

A Development and Performance Test of Voltage Measurement Accuracy Assessment System for Distribution Equipment (배전기기 전압계측 정밀도 평가시스템 개발 및 성능시험)

  • Cho, Jin-Tae;Kim, Ju-Yong;Lee, Hak-Ju;Kim, Jae-Han
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.27 no.9
    • /
    • pp.83-89
    • /
    • 2013
  • Power distribution system has been changed from radial system to closed loop or mesh system due to connection of distributed generation growth. Data from distribution equipments which are installed at distribution line is required to be accurate for the performance of DMS(Distribution Management System). This paper analyzes the voltage measurement data from distribution equipment. However, the results of the analysis are confirmed to have some errors in voltage measurement data from distribution equipment. These errors come from aging of voltage sensor in distribution equipment and inaccurate data transfer to FRTU(feeder remote terminal unit) through the controller. The main problem is that the voltage measurement data of distribution equipment can not be assessed after it's first installation at the distribution line. The voltage measurement accuracy assessment system is to assess the voltage measurement data from distribution equipment on hot-line. This study had a field test to verify the performance of system.

Development of on-line bending stiffness tester - (2) Lab experiment (종이 휨강성 자동 측정방식의 개발과 그 이용 - (2) 실험실 측정)

  • Seo, Yung-Bum;Jung, Seok-Myun;Jung, Tae-Young
    • Proceedings of the Korea Technical Association of the Pulp and Paper Industry Conference
    • /
    • 2007.04a
    • /
    • pp.235-250
    • /
    • 2007
  • A simple method of on-line stiffness measurement using the wrinkling behavior of paper web between rollers was presented. The theory and calculating equation were presented, and lab experiment was executed. We called the stiffness measured by Taber tester as 'Taber stiffness', and by tension wrinkling measurement as 'wrinkle stiffness', respectively, for comparison. Lab experimental results showed Taber and wrinkle stiffness are almost equivalent. We expect this method will work porperly for the on-line measurement of paper stiffness in near future.

  • PDF

Development of On-line Bending Stiffness Tester (2) - Lab experiment - (종이 휨강성 자동 측정방식의 개발과 그 이용 (2) - 실험실 측정 -)

  • Seo, Yung-Bum;Jung, Suk-Myun;Jung, Tae-Young
    • Journal of Korea Technical Association of The Pulp and Paper Industry
    • /
    • v.39 no.4
    • /
    • pp.21-28
    • /
    • 2007
  • A simple method of on-line stiffness measurement using the wrinkling behavior of paper web between two rollers was presented. The theory and the equation were presented, and lab and mill tests were executed. We called the stiffness measured by Taber tester as 'Taber stiffness', and by tension wrinkling measurement as 'wrinkle stiffness', respectively. Lab experimental results showed Taber and wrinkle stiffness are almost equivalent. In the mill experiment, we could measure the stiffness in the wet state and in the dry state. The dry wrinkle stiffness was close to the taber stiffness, but the wet wrinkle stiffness was much lower than the corresponding taber stiffness.

A Study for the Measurement Method of Electromagnetic Field Strength of Power Line Communications Modem (전력선통신모뎀의 전자계강도 측정방법 연구)

  • Jang Dong-Won
    • 한국정보통신설비학회:학술대회논문집
    • /
    • 2006.08a
    • /
    • pp.162-165
    • /
    • 2006
  • This paper describes a measurement method for electromagnetic field strength of power-line communications(PLC) modem. First it outlines the technology used in PLC modems, and the technical regulation being offered to the technology, from the point of view of its effect on electromagnetic compatibility (EMC). The radio spectrum needs protection from other interferers, and there is a regime in place to provide this protection. Difficulties in achieving compatibility between the requirements for radio protection and the requirements for operation of the PLC modem mean that there is no consensus as yet as to how PLC modem components can be made compliant with EMC requirements globally. It is concluded that there is a measurement method according to CISPR standards which satisfy requirements in domestic regulation.

  • PDF

Monitoring of Temperature and Strain Variation with FBG Sensors (FBG 센서를 활용한 온도와 스트레인 변화 모니터링)

  • Ko, Ki-Han;Park, Young;Cho, Yong-Hyeon;Jung, Ho-Sung;Cho, Yong-Suk;Choi, Won-Seok
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.22 no.3
    • /
    • pp.218-221
    • /
    • 2009
  • This paper reports on measurement method for the fiber optic strain monitoring of overhead contact line systems of trains, We used FBG (Fiber Bragg Grating) sensors to measure the strain variation of overhead contact line. FBG sensors can sensitively measure the variation of strain and! or temperature by the shift wavelength of reflected wave according to the lattice variation during the measurement. FBG sensor were attached on the contact line and connected to the monitoring system with optical fibers. The monitering system with FBG sensors showed very good sensitivity to measuring strain variation and this system could be applied to the overhead contact line of KTX (Korea Train eXpress).