• Title/Summary/Keyword: on-line measurement

Search Result 1,874, Processing Time 0.032 seconds

Development of On-Line Measurement System for Adsorption Process (흡착공정용 온라인 측정시스템의 개발)

  • Kim, Byoung Chul;Lee, Ki Sung;Yamamoto, Takuji;Kim, Young Han
    • Korean Chemical Engineering Research
    • /
    • v.47 no.3
    • /
    • pp.321-326
    • /
    • 2009
  • A simple measuring device is proposed, and its performance is examined in an adsorption process separating a gas mixture. The sensor is made of a quartz crystal resonator and solid adsorbent to detect the target component. Micro-particle carbon cryogel(MCC) is utilized as the adsorbent, and the gas mixture of air and i-butane are separated in a column containing bamboo activated carbon. Two devices are placed at the inlet and outlet of the column. The measurements are compared with those of GC outcome to prove the measurements are effective. The experimentally proved system is simple and capable to be implemented in an in-line system with on-line measurement.

A Study on the Adequacy Analysis of Distribution Line Drop for Improvement of Consumer Voltage Fluctuation (수용가 전사변동의 개선을 위한 배전선로의 적정성해석에 관한 연구)

  • 김은배;정상흔
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.31 no.7
    • /
    • pp.11-17
    • /
    • 1982
  • In this paper, a reliable and convenient evaluation method for the adequacy of any radial distribution line's voltage drop is proposed for improvement of the voltage regulation of the distribution line under operation. Using the voltage measurement of the first load branch point and the last point on the given distribution line its average line voltage drop and the line voltage drop variance by pure load variation are computed. And by these values and allowable or required line drop from proper voltage regulation view point, present adequency index and operation improvement index of the line drop are newly introduced for the evaluation of the given distribution line's voltage regulation. As a result of application to the 4 cases of study, the proposed method is proved to be reliable and convenient.

  • PDF

Noise Suppression Method for Restoring Line Spectrum Pair (선스펙트럼 쌍의 복원에 의한 잡음억제 기법)

  • Choi, Jae-Seung
    • Journal of the Institute of Electronics Engineers of Korea SP
    • /
    • v.47 no.4
    • /
    • pp.112-118
    • /
    • 2010
  • This paper describes a noise suppression system based on a normalization method using a time-delay neural network and line spectrum pair having a parameter of frequency domain. First, a time-delay neural network is trained using line spectrum pair values of noisy speech signals obtained by linear prediction analysis. After trained the time-delay neural network, the proposed system enhances speech signals that are degraded by a background noise. Accordingly, the proposed time-delay neural network restores from the line spectrum pair values of noisy speech signals to the line spectrum pair values of clean speech signals. It is confirmed that this system is effective for speech signals degraded by a background noise, judging from spectral distortion measurement.

Measurement of the indoor power line channel characteristic (옥내 전력선 통신 채널 특성 측정)

  • Heo, Yun-Seok
    • The Journal of Information Technology
    • /
    • v.7 no.3
    • /
    • pp.1-10
    • /
    • 2004
  • Considerable efforts has been recently devoted to the determination of accurate channel models for the Power Line environment, both for the indoor and outdoor cases. The common denominator and limitation of the known and previously published models is the particular type of approach followed. In this paper is concerned with a power line channel modeling for the more fast and efficiently power line communication experiment. A capacitor load channel simulator is a essential equipment in the power line modem development for indoor network. We accomplished a channel modelling by the frequency response method about the total 224 capacitor load cases. On the basis of this measurement modeling it is here revealed that the PLC is a more deterministic media that commonly believed.

  • PDF

Trust Analysis of Ground Resistance Measurements by the Substitute Auxiliary Electrode (대체 보조전극을 이용한 접지저항 측정 신뢰성 분석)

  • Lee, Sang-Ick;Yoo, Jae-Geun;Jeon, Jeong-Chay;Jeon, Hyun-Jae
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.56 no.2
    • /
    • pp.109-114
    • /
    • 2007
  • This paper summarize about the auxiliary electrode measured a ground resistance. The method to measure a ground resistance is the fall-of-potential method to using an auxiliary electrode. And an auxiliary electrode must be set up on the ground. Today it is so difficult to set up the auxiliary electrode on the ground because of many concrete building and many paved roads. So this paper is regarding a trust analysis of the ground resistance measurement by the substitute auxiliary electrode. It substituted a iron structure around the building, a neutral line multiplex ground to earth, a wire net for auxiliary electrode. This information is confirmed bv compared with the measurement value.

A Study on the Determination of Displacement by Applied Laser Measurement (레이저응용계측에 의한 변위 정량화에 관한 연구)

  • 김경석;홍진후;강기수;최지은
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2000.11a
    • /
    • pp.93-96
    • /
    • 2000
  • This study discusses a non-contact optical technique, phase shifting electronic speckle pattern interferometry, that is well suited for a deformation measurement. However, the phase shifting method has difficulties for determinating a deformation quantitatively beacuse of the characteristics of arctan function. In order to solve this problem, phase unwrapping methods has been studied during the last few years. In this study, using phase unwrapping based on line by line scanning phase shifted fringe patterns are studied to determinate a deformation quantitatively. Also least square fitting method is applied to reduce noise and improve image resolution.

  • PDF

Development of Green-Sheet Measurement Algorithm by Image Processing Technique (영상처리기법을 이용한 그린시트 측정알고리즘 개발)

  • Pyo, C.R.;Yang, S.M.;Kang, S.H.;Yoon, S.M.
    • Transactions of Materials Processing
    • /
    • v.16 no.4 s.94
    • /
    • pp.313-316
    • /
    • 2007
  • The purpose of this paper is the development of measurement algorithm for green-sheet based on the digital image processing technique. The Low Temperature Co-fired Ceramic(LTCC) technology can be employed to produce multilayer circuits with the help of single tapes, which are used to apply conductive, dielectric and/or resistive pastes on. These single green-sheets must be laminated together and fired at the same time. Main function of the green-sheet film measurement algorithm is to measure the position and size of the punching hole in each single layer. The line scan camera coupled with motorized X-Y stage is used. In order to measure the entire film area using several scanning steps, an overlapping method is used.

Measurement of High Voltage Capacitor in On-line System (실시스템에서의 고압용 진상용 캐패시터 특성시험)

  • Song, Sang-Hoon;Seo, Min-Sung;Yu, Woo-Sun;Jo, Sung-Soo;Won, Chung-Yuen
    • Proceedings of the KIEE Conference
    • /
    • 2002.07d
    • /
    • pp.2319-2321
    • /
    • 2002
  • This paper suggests a computer-based on-line measurement method of tan$\delta$ and capacitance for HV capacitor. The method employs V-I technique using scaled down analog voltage and current signal obtained by digital oscilloscope. The measurement results are displayed by graphic user interface with graphic language. Field tests were tarried out at 6.6kV testing voltage in Samhwa Capacitor company.

  • PDF

On-line Stabilizing Control Scheme for Power System (On-line 안정화 제어기법)

  • Oh, Tae-Kyoo;Kim, Hak-Man;Suh, Eui-Suk;Kim, Il-Dong;Kim, Yong-Hak
    • Proceedings of the KIEE Conference
    • /
    • 1997.07c
    • /
    • pp.903-906
    • /
    • 1997
  • When large capacity generation stations that consist of several large units tend to pull out of step from main power system, stabilizing control scheme as emergency control for preventing loss of synchronism of the whole stations with the remaining system is devided into two steps that the first step is to perform on-line prediction for out-of-step and the next step is on-line calculation of the amount of generation shedding for the rest of generators to be in step when out of step is expected. This paper presents on-line prediction scheme for out-of-step based on P-$\delta$ curve estimation using real-time measurement and on-line calculation of generation shedding. The proposed stabilizing scheme was applied to case study of real power system and the results obtained by the method compare well with the results by simulation.

  • PDF

Development of a Transmission Error Measurement System and Its Adaptation to a Manufacturing Line (기어 전달오차 측정 시스템의 개발 및 라인 적용에 관한 연구)

  • Lee, Hyun Ku;Lee, Sang Hwa;Ku, Han Il;Yoo, Dong Kyu;Won, Kwang Min;Lee, Tae Hwi
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.26 no.4
    • /
    • pp.420-427
    • /
    • 2016
  • Diverse research on gearing systems have been made to resolve gear NVH problems for many decades, and transmission error (T.E.) has been identified as one of the main sources generating gear noises. While gear profiles and amounts of tooth modifications have influences on gear noise in the design aspect, it is found that bad manufacturing conditions such as burrs, bumps and damage, which result in improper gear operating conditions, produce gear noise with respect to manufacturing process. In this paper, T.E. measurement system was introduced to examine the gears damaged or improperly manufactured, while they are assembled, by comparing T.E. values and various gear conditions with theoretical ones. This T.E. measurement system, following grinding machining process, has been installed in a manufacturing line in 2014, and it results that the transmission rework to resolve manufacturing problems is not needed at the end of line.