• 제목/요약/키워드: on-line fault detection

검색결과 167건 처리시간 0.023초

Support Vector Machine-Regression을 이용한 주기신호의 이상탐지 (A Fault Detection of Cyclic Signals Using Support Vector Machine-Regression)

  • 박승환;김준석;박정술;김성식;백준걸
    • 품질경영학회지
    • /
    • 제38권3호
    • /
    • pp.354-362
    • /
    • 2010
  • This paper presents a non-linear control chart based on support vector machine regression (SVM-R) to improve the accuracy of fault detection of cyclic signals. The proposed algorithm consists of the following two steps. First, the center line of the control chart is constructed by using SVM-R. Second, we calculate control limits by variances that are estimated by perpendicular and normal line of the center line. For performance evaluation, we apply proposed algorithm to the industrial data of the chemical vapor deposition process which is one of the semiconductor processes. The proposed method has better fault detection performance than other existing method

전류정보를 이용한 가변속냉동시스템의 열교환기 실시간 고장 진단 (On-line Fault Detection and Diagnosis for Heat Exchanger of Variable Speed Refrigeration System Based on Current Information)

  • 이동규;정석권
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2007년도 동계학술발표대회 논문집
    • /
    • pp.88-94
    • /
    • 2007
  • This study deals with on-line fault detection and diagnosis for heat exchanger of variable speed refrigeration system. Conventional studies about fault of heat exchanger in refrigeration system have used temperature and pressure information. The temperature and pressure are able to be used valuably for faults detection of constant speed refrigeration system. However in case of variable speed refrigeration system, the temperature and pressure are no longer useful information for fault detection due to compensation effect of feedback controller. While current information is possible to detect faults of variable speed refrigeration system. The current information was detected in an inverter, it was used after transforming rms value. The faults of variable speed refrigeration system are divided into electrical faults and mechanical faults. We performed fault detection and diagnosis about heat exchanger among mechanical faults such as condenser fouling and evaporator fan fouling through some experiments.

  • PDF

탄약운반 자동화 시스템의 고장 검출 및 분류 기법 (A Fault Detection and Isolation Method for Ammunition Transport Automation System)

  • 이승연;강길순;유준
    • 제어로봇시스템학회논문지
    • /
    • 제11권10호
    • /
    • pp.880-887
    • /
    • 2005
  • This paper presents a fault diagnosis(detection and isolation) approach for the Ammunition Transport Automation system(ATAS). Due to limited time and information available during its cyclic operation, the on-line fault detection algorithm consists of sequential test logics referring to the normal states, which can be considered as a kind of expert system. If a failure were detected, the off-line isolation algorithm finds the fault location through trained ART2 neural network. By the results of simulations and some on-line field test, it has been shown that the presented approach is effective enough and applicable to related automation systems.

배전선로의 특이파형 검출 방법에 관한 연구 (A Study on Detection Method of Specific Waveform in Distribution Line)

  • 이진;박찬
    • 한국전기전자재료학회논문지
    • /
    • 제32권2호
    • /
    • pp.151-156
    • /
    • 2019
  • The aim of this investigation is to detect specific waveforms in a distribution line prior to the occurrence of a fault. Conditions were introduced such that a feeder remote terminal unit (FRTU) of the distribution automation system selects and stores fault waveforms from the different waveforms detected in the distribution line. In addition, an algorithm was developed to detect specific waveforms from the fault waveforms stored using the FRTU. This algorithm exploits the duration and periodicity of harmonic changes in voltage and current. The efficacy of the algorithm was confirmed based on the measurements of fault waveforms in an actual distribution line. The results indicated that faults in a distribution line can be predicted via experimental measurements.

지능형 디지탈 보호계전 알고리즘 연구 (Study of an algorithm for intelligent digital protective relaying)

  • 신현익;이성환;강신준;김정한;김상철
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 1996년도 한국자동제어학술회의논문집(국내학술편); 포항공과대학교, 포항; 24-26 Oct. 1996
    • /
    • pp.343-346
    • /
    • 1996
  • A new method for on-line induction motor fault detection is presented in this paper. This system utilizes unsupervised-learning clustering algorithm, the Dignet, proposed by Thomopoulos etc., to learn the spectral characteristics of a good motor operating on-line. After a sufficient training period, the Dignet signals one-phase ground fault, or a potential failure condition when a new cluster is formed and persists for some time. Since a fault condition is found by comparison to a prior condition of the machine, on-line failure prediction is possible with this system without requiring information on the motor of load characteristics.

  • PDF

온라인 식별 및 매개변수 추정을 이용한 실시간 e-Actuator 오류 검출 (Realtime e-Actuator Fault Detection using Online Parameter Identification Method)

  • 박준기;김태호;이흥식;박찬식
    • 전기학회논문지
    • /
    • 제63권3호
    • /
    • pp.376-382
    • /
    • 2014
  • E-Actuator is an essential part of an eVGT, it receives the command from the main ECU and controls the vane. An e-Actuator failure can cause an abrupt change in engine output and it may induce an accident. Therefore, it is required to detect anomalies in the e-Actuator in real time to prevent accidents. In this paper, an e-Actuator fault detection method using on-line parameter identification is proposed. To implement on-line fault detection algorithm, many constraints are considered. The test input and sampling rate are selected considering the constraints. And new recursive system identification algorithm is proposed which reduces the memory and MCU power dramatically. The relationship between the identified parameters and real elements such as gears, spring and motor are derived. The fault detection method using the relationship is proposed. The experiments with the real broken gears show the effectiveness of the proposed algorithm. It is expected that the real time fault detection is possible and it can improve the safety of eVGT system.

Two-Terminal Numerical Algorithm for Single-Phase Arcing Fault Detection and Fault Location Estimation Based on the Spectral Information

  • Kim, Hyun-Houng;Lee, Chan-Joo;Park, Jong-Bae;Shin, Joong-Rin;Jeong, Sang-Yun
    • Journal of Electrical Engineering and Technology
    • /
    • 제3권4호
    • /
    • pp.460-467
    • /
    • 2008
  • This paper presents a new numerical algorithm for the fault location estimation and arcing fault detection when a single-phase arcing ground fault occurs on a transmission line. The proposed algorithm derived in the spectrum domain is based on the synchronized voltage and current samples measured from the PMUs(Phasor Measurement Units) installed at both ends of the transmission lines. In this paper, the algorithm uses DFT(Discrete Fourier Transform) for estimation. The algorithm uses a short data window for real-time transmission line protection. Also, from the calculated arc voltage amplitude, a decision can be made whether the fault is permanent or transient. The proposed algorithm is tested through computer simulation to show its effectiveness.

PWM 증기발생기의 고장검출 및 진단에 관한 연구 (A Fault Detection and Diagnosis in a PWR Steam Generator)

  • Park, Seung-Yub
    • 대한전기학회논문지
    • /
    • 제40권1호
    • /
    • pp.120-127
    • /
    • 1991
  • The purpose of this study is to develop a fault detection and diagnosis scheme that can monitor process fault and instrument fault of a steam generator. The suggested scheme consists of a Kalman filter and two bias estimators. Method of detecting process and instrument fault in a steam generator uses the mean test on the residual sequence of Kalman filter, designed for the unfailed system, to make a fault decision. Once a fault is detected, two bias estimators are driven to estimate the fault and to discriminate process fault and instrument fault. In case of process fault, the fault diagnosis of outlet temperature, feed-water heater and main steam control value is considered. In instrument fault, the fault diagnosis of steam genrator's three instruments is considered. Computer simulation tests show that on-line prompt fault detection and diagnosis can be performed very successfully.

  • PDF

A Dissimilarity with Dice-Jaro-Winkler Test Case Prioritization Approach for Model-Based Testing in Software Product Line

  • Sulaiman, R. Aduni;Jawawi, Dayang N.A.;Halim, Shahliza Abdul
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • 제15권3호
    • /
    • pp.932-951
    • /
    • 2021
  • The effectiveness of testing in Model-based Testing (MBT) for Software Product Line (SPL) can be achieved by considering fault detection in test case. The lack of fault consideration caused test case in test suite to be listed randomly. Test Case Prioritization (TCP) is one of regression techniques that is adaptively capable to detect faults as early as possible by reordering test cases based on fault detection rate. However, there is a lack of studies that measured faults in MBT for SPL. This paper proposes a Test Case Prioritization (TCP) approach based on dissimilarity and string based distance called Last Minimal for Local Maximal Distance (LM-LMD) with Dice-Jaro-Winkler Dissimilarity. LM-LMD with Dice-Jaro-Winkler Dissimilarity adopts Local Maximum Distance as the prioritization algorithm and Dice-Jaro-Winkler similarity measure to evaluate distance among test cases. This work is based on the test case generated from statechart in Software Product Line (SPL) domain context. Our results are promising as LM-LMD with Dice-Jaro-Winkler Dissimilarity outperformed the original Local Maximum Distance, Global Maximum Distance and Enhanced All-yes Configuration algorithm in terms of Average Fault Detection Rate (APFD) and average prioritization time.

사고위치를 고려한 분산전원의 단독운전 상태 검출에 관한 연구 (A Study on Islanding Detection of Distributed Generation Considering Fault Location)

  • 정승복;김재철
    • 조명전기설비학회논문지
    • /
    • 제18권4호
    • /
    • pp.118-123
    • /
    • 2004
  • 분산전원의 단독운전 검출에 관한 기존의 연구들은 사고위치에 따른 다양한 상황을 고려하지 않고 조건들만 만족되면 분산전원측을 무조건 분리시켰다. 하지만 분산전원이 연계되어 있지 않은 인근선로사고의 경우에는 인근선로측 보호기기의 동작으로 전원 측으로부터 정상적인 전원이 공급되기 때문에 분산전원을 분리시킬 필요가 없다. 또한 연계선로 사고의 경우일지라도 분산전원이 즉시 분리돼야 하는 경우인지, 단독운전인지, 정상운전의 경우인지 과부하차단에 의한 보호기기 동작의 경우인지를 고려해야 한다. 본 논문에서는 이러한 고려사항들을 계통의 전력상태 변화를 통해 구분하고 단독운전 시 및 분산전원을 분리해야 되는 상황을 찾아서 분산전원을 분리시키는 단독운전 상태 검출 알고리즘을 제안하였다. 고립운전 상태 검출 알고리즘을 검증하기 위하여 PSCAD/EMTDC를 이용하여 사례별로 시뮬레이션을 수행하였다.