• Title/Summary/Keyword: on-line analysis

Search Result 7,832, Processing Time 0.04 seconds

Steady-State Characteristic Analysis of Single-Phase Line-Start Permanent Magnet Synchronous Motor (단상 영구자석형 유도동기기의 정상상태 특성해석)

  • Kang, Gyu-Hong;Nam, Hyuk;Hong, Jung-Pyo
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.52 no.2
    • /
    • pp.53-60
    • /
    • 2003
  • This paper deals with steady-state analysis of a single-phase line-start permanent magnet synchronous motor. In order to analyze the steady-state characteristics, the asymmetric single-phase line-start synchronous motor is converted to the symmetric two-phase synchronous motor, that is, the asymmetric magnetic field is separated from the positive and the negative symmetric components using symmetrical-component theory. The analysis method of the synchronous motor on the d-q axis coordinates is used for the positive component and the equivalent circuit of the induction motor is applied for the negative component analysis. Moreover, d-q axis inductance considering current phase angle is applied to positive component analysis for precise characteristic analysis. In order to validate the proposed analysis method, the analysis results are compared with the experimental results.

The effect of hooking on thickness and length of branch line in fishing gear of long line at the coastal waters (연안 연승어구에 있어서 아릿줄의 굵기와 길이가 조획에 미치는 영향)

  • Yang, Chin-Sung;Kim, Suk-Jong
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.48 no.1
    • /
    • pp.51-58
    • /
    • 2012
  • As a basic study to improve hooking ability of long line fishing gear, which is widely used around Jeju-do coast, the researcher performed hooking experiment of parrot fish by manufacturing and installing 7 kinds of model long line fishing gears, whose thickness of branch line are different and 8 kinds of model long line fishing gear, whose length of branch line are different, in indoor circular aquarium, which is installed for the model experiment of thickness and length of branch line that are various by fishing implement and improper. The hooking rate depending on thickness and length of branch line was calculated and the effect of thickness and length of branch line on hooking rate was analyzed. Its results are as follows. When branch line was thin and long, high hooking rate appeared. In the scope of value setting, the relationship between thickness ($B_t$) of branch line and total hooking rate ($Th_r$) can be shown as following formula as. In the scope of value setting, the relationship between length ($B_t$) of branch line and total hooking rate ($B_t$) can be shown as $Th_r=-20.83B_t+26.04$. Through Pearson correlation analysis, the coefficient of correlation between thickness of branch line and hooking rate was -0.718. Therefore it showed significance in 0.01 significance level. Through Pearson correlation analysis, the coefficient of correlation between length of branch line and hooking rate was 0.431. Therefore it showed significance in 0.01 significance level.

A Study of Leadership Training Program Demands of First-Line Nurse Managers in University Hospitals (일선 간호관리자의 리더쉽 프로그램 요구 조사)

  • Go, Myeong-Suk
    • The Korean Nurse
    • /
    • v.37 no.1
    • /
    • pp.107-115
    • /
    • 1998
  • There is an important concern regarding the First-line nurse manager's leadership because of the recognition that effectiveness of Leadership in this position results in benefits for the whole health care organization. So knowledge and practice of effective leadership behavior are now more essential to nursing than ever before. First-line Nurse Managers must be effective leaders to meet today's challenge because staff nurse, patient are affected by them. So the purpose of this study was to identify and to analyse the need for Leadership program of First-Line nurse managers in university hospitals. There were three major purposes of this study. First, identify First-line nurse managers general characteristic, second, identify their experience of leadership training, third, identify and analysis their demands for leadership training program. The subjects for this study was 167 First-line nurse manager randomly from 18 university hospitals in Korea. The data were collected through questionnaires from Oct. 13th to Nov. 20th, 1997, data was analysed using frequencies and percentages. Especially the steps of analysis of descriptions were as follows: Initial analysis centered on the identification of the demands of first-line nurse managers. Later analysis collapsed the demands into broad categories. From the collect data, 283 demands of first-line nurse managers were identified. These demands were then sorted into 3 broad categories that included : Self development as first-line nurse managers, relationship with others, and practice. The result of the study were as follows ; 1) Most of nurse managers(79.6%) had leadership training course and had good experience to improve self leadership. 2) Their demands of leadership training course are as follows First, for self as first-line nurse managers, they want to learn leadership theory, identify their leadership style and then develop their leadership skill. Second, for others as first-line nurse managers, they want to improve their communication skill, empowering others, relationship with others. Third, for patients as first-line nurse managers, improve their knowledge of practice. From the above finding, this study can be suggested the following; 1. Develope a leadership training course to improve first- line nurse manager's leadership skill according to their demands, so they will be better able to lead staff nurses for organization purposes. 2. When develope leadership training program, it must be contained the factors which first-line nurse managers want to learn.

  • PDF

A New Line to Line Fault Location Algorithm in Distribution Power Networks using 3 Phase Direct Analysis (3상회로의 직접해석에 의한 송배전계통 선간단락 사고 고장거리 계산 알고리즘)

  • Choe, Myeon-Song;Lee, Seung-Jae;Im, Seong-Il;Jin, Bo-Geon;Lee, Deok-Su
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.51 no.9
    • /
    • pp.467-473
    • /
    • 2002
  • In this paper, a fault location algorithm is suggested for line to line faults in distribution networks. Conventional fault location algorithms use the symmetrical component transformation, a very useful tool for transmission network analysis. However, its application is restricted to balanced network only. Distribution networks are, in general, operated in unbalanced manners, therefore, conventional methods cannot be applied directly, which is the reason why there are few research results on fault location in distribution networks. Especially, the line to line fault is considered as a more difficult subject. The proposed algorithm uses direct 3-phase circuit analysis, which means it can be applied not only to balanced networks but also to unbalanced networks like distribution a network. The comparisons of simulation results between one of conventional methods and the suggested method are presented to show its effectiveness and accuracy.

Developing the On-line Game Industry's Changing Scenario and Establishing Business Strategy According to the Introduction of IPTV (IPTV 도입에 따른 온라인 게임 산업의 변와 시나리오 개발 및 경영 전략 수립)

  • Kim, Min-Kwan;Han, Chang-Hee
    • Information Systems Review
    • /
    • v.10 no.2
    • /
    • pp.21-48
    • /
    • 2008
  • The Korean on-line game industry is going through a rapid change. The future business environments for potential on-line game companies are very uncertain due to the new service and the different market trends. In this paper, I propose the use of morphological analysis approach for scenario generation about the future of the On-line game industry. The stages of research process were as follows; Firstly, digital contents analysis and key issues were drawn on IPTV in the on-line game industry. Secondly, each key issue was analyzed and the influence factors and directivity flow were found. Thirdly, highly probable future on-line game industry scenarios were derived. In this case, morphological analysis. On the basis of the developed scenarios, I formulated some implications for business strategy of a potential on-line game companies.

Developement of On-Line System for Vibration Signal Analysis (진동신호 분석을 위한 On-Line 시스템 개발)

  • Kim, O.S.;Rim, S.J.;Kim, Y.S.;Lee, Y.G.;Kim, J.C.;Chung, C.S.;Chung, S.J.
    • Proceedings of the KIEE Conference
    • /
    • 1995.07b
    • /
    • pp.616-619
    • /
    • 1995
  • This paper describes developement of on-line system for vibration signal analysis. In the power system, the main reason of transformer fault is due to a large amount of current by a short-circuit and a ground-fault. The electromagnetic force caused by fault-current deforms transformer windings and results in vibration pattern change. Therefore if the continuous on-line vibration monitoring on transformer is performed, an incipient failure can be detected. The developed system is composed of data acquisition devices, user interface program, signal processing program, diagnosis and trend analysis program, self diagnosis program and communication program.

  • PDF

Tracking Performance Test of Polymer Insulator with Salt Solution which is added Surface Active Agent (계면활성제가 첨가된 염수용액에 따른 폴리머 애자의 트래킹 성능 평가)

  • Cho, Han-Goo;Han, Dong-Hee;Lee, Un-Yong;Lim, Kee-Joe;Choi, In-Hyuk
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2004.07b
    • /
    • pp.1121-1124
    • /
    • 2004
  • Aging test to estimate life property of polymer insulator is executed through several international standard such as IEC 61109 and CEA tracking wheel test, but is not getting clear conclusion yet. There are two methods in the diagnosis method of polymer insulator such as off-line and on-line. The diagnosis methods in off-line are external condition analysis by the eye, contaminant analysis on surface, surface analysis, pollution withstand voltage test, power frequency flashover voltage test, lightning impulse flashover test, tensile fracture load test and flexural load test. The diagnosis methods in off-line most are the method for virgin and last aged sample. However, the diagnosis method in on-line is method that can be evaluate sample state as progressing continuously aging test in beginning, The diagnosis method in on-line is arranged as following: leakage current measurement, electric field, surface state investigation, thermal image, emitting light measurement and then so. In this paper, the tracking performance of polymer insulator with salt solution which is added surface active agent. The diagnosis of insulator sample has been analyzed by leakage current and visual examination.

  • PDF

A Study on Determination of Fire Origin by Shadow analysis (화염 그림자 분석을 통한 최초 발화지점 확인에 관한 연구)

  • Lee, Seunghun;Choi, Minki;Choi, Donmook
    • Journal of the Korea Safety Management & Science
    • /
    • v.16 no.3
    • /
    • pp.165-173
    • /
    • 2014
  • This study is about determination of fire origin by using analysis of shadow that was recorded CCTV data at the fire scene. This analysis is based on straight and radiate nature of light. At fire experiment with about 1m flame, we conformed that 2-dimensional extension line is focused at the bottom of the fire. If the fire is burning at the same level with shadow, it indicate the point of origin exactly. In 3-dimensional analysis that connect extensional line between distinctive points the shadow and the objet, the line focused in the ${\emptyset}$ 50cm-circle. We estimate the reason of that is because of the character of combustion of gases. The line indicate not the point of origin but the flame that is over the point of origin. thus, you have to consider the line indicate the flame when you do 3-dimensional analysis.

A Systemic Analysis on Pemetrexed in Treating Patients with Breast Cancer

  • Wan, Fang;Chen, Xin;Dong, Li-Fan;Cheng, Yue-Hong;Long, Jing-Pei
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.15 no.11
    • /
    • pp.4567-4570
    • /
    • 2014
  • Background: This systemic analysis was conducted to evaluate the efficacy and safety of pemetrexed based chemotherapy in treating patients with metastatic breast cancer as first or second line chemotherapy. Methods: Clinical studies evaluating the efficacy and safety of pemetrexed based regimens on response and safety for patients with breast cancer were identified using a predefined search strategy. Pooled response rate (RR) of treatment were calculated. Results: In first line pemetrexed based regimens, 10 clinical studies which including 513 patients with advanced breast cancer were considered eligible for inclusion. For second line pemetrexed based chemotherapy, 5 clinical studies which including 281 patients with advanced breast cancer were considered eligible. Systemic analysis suggested that, in all patients, pooled RR was 32.6% (167/513) in pemetrexed based first line regimens, and 13.9 % (39/281) in pemetrexed based second line regimens. Major adverse effects were neutropenia, leukopenia, fatigue, and anemia in pemetrexed based first line treatment; and lymphopenia, neutropenia, leukopenia, as well as anemia in second line chemotherapy. One treatment related death occurred with pemetrexed based second line treatment. Conclusion: This systemic analysis suggests that pemetrexed based first line regimens are associated with a reasonable response rate and acceptable toxicity, however with low response rate for treating patients with metastatic breast cancer when is used in the second line.

Relations between Input Parameters and Residual Deformation in Line Heating process using Finite Element Analysis and Multi-Variate Analysis (유한요소해석과 다변수해석에 의한 선상가열 변형관계식)

  • Jang-Hyun Lee;Jong-Gye Shin
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.39 no.2
    • /
    • pp.69-80
    • /
    • 2002
  • Sequential process of roll-bending and line heating has been used to deform the curved hull-plates in shipyards. A growing interest for the mechanization or automation of the line heating process has been noted. Relations between heating conditions and residual deformations are important components needed for the mechanization. The residual deformations are investigated by using a thermal elastic-plastic analysis based on the finite element analysis(FEA). Several experiments are also performed to examine the validity of the results of FEA. The input parameters of line heating are suggested by dimensional analysis of line heating. The dimensional analysis can extract the primary input-parameters of line heating. The relations between the heating conditions and the residual deformations are set up by multi-variate analysis and multiple-regression method. This study suggests a method for the relation between the heating conditions and the deformations lying under the line heating.