• Title/Summary/Keyword: on-device

Search Result 19,670, Processing Time 0.049 seconds

A Transmission Electron Microscopy Study on the Crystallization Behavior of In-Sb-Te Thin Films (In-Sb-Te 박막의 결정화 거동에 관한 투과전자현미경 연구)

  • Kim, Chung-Soo;Kim, Eun-Tae;Lee, Jeong-Yong;Kim, Yong-Tae
    • Applied Microscopy
    • /
    • v.38 no.4
    • /
    • pp.279-284
    • /
    • 2008
  • The phase change materials have been extensively used as an optical rewritable data storage media utilizing their phase change properties. Recently, the phase change materials have been spotlighted for the application of non-volatile memory device, such as the phase change random access memory. In this work, we have investigated the crystallization behavior and microstructure analysis of In-Sb-Te (IST) thin films deposited by RF magnetron sputtering. Transmission electron microscopy measurement was carried out after the annealing at $300^{\circ}C$, $350^{\circ}C$, $400^{\circ}C$ and $450^{\circ}C$ for 5 min. It was observed that InSb phases change into $In_3SbTe_2$ phases and InTe phases as the temperature increases. It was found that the thickness of thin films was decreased and the grain size was increased by the bright field transmission electron microscopy (BF TEM) images and the selected area electron diffraction (SAED) patterns. In a high resolution transmission electron microscopy (HRTEM) study, it shows that $350^{\circ}C$-annealed InSb phases have {111} facet because the surface energy of a {111} close-packed plane is the lowest in FCC crystals. When the film was heated up to $400^{\circ}C$, $In_3SbTe_2$ grains have coherent micro-twins with {111} mirror plane, and they are healed annealing at $450^{\circ}C$. From the HRTEM, InTe phase separation was occurred in this stage. It can be found that $In_3SbTe_2$ forms in the crystallization process as composition of the film near stoichiometric composition, while InTe phase separation may take place as the composition deviates from $In_3SbTe_2$.

HISTOLOGICAL CHANGES IN THE ELONGATED BONE AFFECTED BY OSTEODISTRACTION OF THE MANDIBLE IN THE DOG (성견 하악골 절단 후 기계적 골 견인에 의해 형성된 골 신장부에 대한 시기별 조직학적 변화)

  • Baek, Sun-Ho;Ahn, Byoung-Keun;Park, Young-Ju;Park, Hee-Geon;Park, Jun-Woo;Rhee, Gun-Joo;Lee, Yong-Chan;Cho, Byoung-Ouck
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.27 no.5
    • /
    • pp.404-416
    • /
    • 2001
  • Purpose : Traditionally, the treatement of choice has been a bone grafting procedure to increase the length of bone in case of actual length discrepancy. But, bone grafting procedure has many disadvantages, for example, graft resorption, donor site morbidity, and so on. So, many trials have been performed to avert the use of autogenous bone graft via introducing new materials or methods. And, one of those trials has been realized by the development of a technique inducing bone lengthening by osteotomy (or corticotomy) and slow gradual distraction of the osteotomized segments. This new technique of bone lengthening dates back to the early 20th century. But, the majority of information concerning the biology of new bone formation during bone lengthening and technical details of the procedure were produced by extensive clinical and experimental studies performed by Ilizarov, a Russian surgeon. According to Ilizarov, with adequate blood supply, preservation of periosteum, rigid fixation of the osteotomized segments, and proper rate and rhythm of distraction, intramembranous bone rapidly develops within the distraction gap in the limb lengthening procedure. In the limb lengthening, many orthopedic surgeons try to observe the biologic and clinical principles recommended by Ilizarov. In the oral and maxillofacial region, however, not a few studies must be performed to apply this surgical technique in the clinical cases. Besides, the mechanism of bone formation in the distraction gap is not clear, yet. The purpose of this experiment was to scrutinize serially the histological changes in the elongated bone affected by osteodistraction of the mandibular body in an adult canine model. In addition, it was performed to confirm the presence of specific region(s) which was important in the bone formation in the gap through the observation of the expression pattern of osteocalcin and osteonectin with the immunohistochemical examination. Materials and Methods : The experimental and control specimens were obtained from seven adult male mongrel dogs weighing over 20kg. The distractors were custom-made linear extraoral devices and bicortical fixation screws were 2.3mm in diameter, 50mm in total length, 15mm in screw length. The distractors were devised to produce a linear gap of 0.75mm between two bony segments every $360^{\circ}$ turn of the rotation rod of the device. The mandibular body of the right side of each animal was corticotomized perpendicular to the occlusal plane and then two bony segments were separated completely by careful manipulation of the segments with bone forceps. The left side of each animal was left intact. This side was served as control. At sixth day after osteotomy and fixation of the segments were performed, distraction of the segments was commenced with a rate of 1.1mm/day and a rhythm of two/day for ensuing 7 days. The animals were euthanized at the 16th. 29th, and 44th day after the osteotomy. The bony specimens were decalcified, embedded in paraffin, sectioned $5{\mu}m$ thick and stained with H&E. The prepared specimens were examined under the light microscope. And, immunohistochemical examinations using anti-osteocalcin antibody (OC1, Biodesign, USA) and anti-osteonectin antibody (Haematologic Technologies Inc., Essex, VT) to locate the expressions of osteocalcin and osteonectin, respectively, were performed. Results : 1. New bone was observed already at the 16th. day after osteotomy. This suggests that new bone formation in osteodistraction was commenced at an early stage of the regenerative process. But, radiologically and microscopically, bony union was not completed in the distraction gap at the 44th. day after osteotomy. Therefore, rigid fixation must be maintained between the bony fragments till the complete bony union is confirmed clinically rather than one month or so after the completion of distraction.

  • PDF

A Study on Preschool Teachers' Dental Health Recognition and Behaviors about Preschoolchildren Dental Health Care (어린이집 교사의 구강보건실태와 유아구강보건관리에 대한 인식)

  • Lee, Hyang-Nim;Shim, Hyung-Sun
    • Journal of dental hygiene science
    • /
    • v.8 no.4
    • /
    • pp.283-289
    • /
    • 2008
  • This study was performed to obtain data about dental health to develop childrens' dental health education program. This research surved from from 22 July 2008 to 11 August 2008 and questionaire given to 140 teacher from Gwangsan-gu and Buk-gu and Dong-gu in Gwangju city. Collected data were analyzed with SPSS 12.0 program. The results of this study were as follows: 1. The dental health condition which teacher is recognizing is most with the facility 52.9% which is healthy, one day toothbrush qualitative number of times 3 times 67.1% and the dental floss qualitative number of times is 49.3%. Uses most the oral hygiene device which plentifully is 51.4% with the dental gargle solution, the dental problem which is knowing dental caries with 45.7% to be highest, perception dental sensitivity was 30.7%. 2. Periodical dental prosecuting says that 93.6% is executing, also the case which a dental inspection result in the parents notifies was 78.6%, after notifying treat, the case which confirms was 60.7%. The case which is the toothbrush qualitative time which is systematic was 95.0%, about dental healthily and food the case which executes an education was 93.6%. 3. About educational background by infantile dental health care of teacher with recognition currently the effectiveness of dental health care is higher from below junior college graduating (p < 0.05). dental hygienic relation experience event participation intention (p < 0.01) comes from the above of university graduation from infantile dental health care from important degree of teacher role was higher the junior college graduation group (p < 0.05). 4. Recognition there was not a difference which is beneficial with an educational background by about career by infantile dental health care of teacher. For the buccal cavity hygiene management of the infants thinks with the fact that also the development of the curricular material and the educational program and teacher buccal cavity hygiene education will be necessary.

  • PDF

The Changes of Short-Term Memory and Autonomic Neurocardiac Function after 4-10Hz Sound and Light Stimulation - A Pilot Study - (4-10 Hz 빛과 소리자극 후 단기기억력 및 자율신경심장기능의 변화 - 예비연구 -)

  • Lee, Seung-Hwan;Kim, Jin-Hwan;Park, Joong-Kyu;Lee, Kyung-Uk;Yang, Dae-Hyun;Hong, Keun-Young;Chae, Jeong-Ho
    • Sleep Medicine and Psychophysiology
    • /
    • v.11 no.1
    • /
    • pp.29-36
    • /
    • 2004
  • Objectives: Sound and light (SL) stimulation has been used as a method to induce some useful mental states in the fields of psychology and psychiatry. It is believed that sound and light entrainment device (SLED) has some specific effects through synchronization of EEG in patients who use it. Theta frequency is believed to stimulate deep relaxation and short term memory processing. This study was conducted to evaluate if 4-10 Hz SL stimulation can induce relaxation and improve short term memory function. Methods: Ten medical students with no medical or psychiatric problems participated in this study. Subjects were randomly divided into two groups. One group was applied with real SLED was applied to one group (R group) and pseudo SLED to the other group (P group). The two groups were exposed to SL stimulation with SLED 15 minutes a day for 5 days, and after two days rest the two groups were switched over. The Korean Wechsler Adult Intelligence Scale (K-WAIS), Academic Motivation Tests (AMT), Test Anxiety Scale (TAS), Korean Auditory Verbal Learning Test (K-AVLT), and digit span were used to evaluate short term memory. Spielberger's State-Trait anxiety inventory and heart rate variability (HRV) test were used to evaluate degree of relaxation. Results: Compared with S group, R group showed a significant improvement in K-AVLT and digit span after a single application of SL stimulation. But 5-day long application did not reveal any differences between the two groups. A significant change in HRV was observed in 5-day long application of SL stimulation after being switched over to other SLED. Conclusion: This pilot study suggests that 4-10 Hz SL stimulation has some positive influences on short term memory and relaxation.

  • PDF

Study on Hydrogen Production and CO Oxidation Reaction using Plasma Reforming System with PEMFC (고분자 전해질 연료전지용 플라즈마 개질 시스템에서 수소 생산 및 CO 산화반응에 관한 연구)

  • Hong, Suck Joo;Lim, Mun Sup;Chun, Young Nam
    • Korean Chemical Engineering Research
    • /
    • v.45 no.6
    • /
    • pp.656-662
    • /
    • 2007
  • Fuel reformer using plasma and shift reactor for CO oxidation were designed and manufactured as $H_2$ supply device to operate a polymer electrolyte membrane fuel cell (PEMFC). $H_2$ selectivity was increased by non-thermal plasma reformer using GlidArc discharge with Ni catalyst simultaneously. Shift reactor was consisted of steam generator, low temperature shifter, high temperature shifter and preferential oxidation reactor. Parametric screening studies of fuel reformer were conducted, in which there were the variations of the catalyst temperature, gas component ratio, total gas ratio and input power. and parametric screening studies of shift reactor were conducted, in which there were the variations of the air flow rate, stema flow rate and temperature. When the $O_2/C$ ratio was 0.64, total gas flow rate was 14.2 l/min, catalytic reactor temperature was $672^{\circ}C$ and input power 1.1 kJ/L, the production of $H_2$ was maximized 41.1%. And $CH_4$ conversion rate, $H_2$ yield and reformer energy density were 88.7%, 54% and 35.2% respectively. When the $O_2/C$ ratio was 0.3 in the PrOx reactor, steam flow ratio was 2.8 in the HTS, and temperature were 475, 314, 260, $235^{\circ}C$ in the HTS, LTS, PrOx, the conversion of CO was optimized conditions of shift reactor using simulated reformate gas. Preheat time of the reactor using plasma was 30 min, component of reformed gas from shift reactor were $H_2$ 38%, CO<10 ppm, $N_2$ 36%, $CO_2$ 21% and $CH_4$ 4%.

Application of Off-axis Correction Method for EPID Based IMRT QA (EPID를 사용한 세기조절방사선치료의 정도관리에 있어 축이탈 보정(Off-axis Correction)의 적용)

  • Cho, Ilsung;Kwark, Jungwon;Park, Sung Ho;Ahn, Seung Do;Jeong, Dong Hyeok;Cho, Byungchul
    • Progress in Medical Physics
    • /
    • v.23 no.4
    • /
    • pp.317-325
    • /
    • 2012
  • The Varian PORTALVISION (Varian Medical Systems, US) shows significant overresponses as the off-center distance increases compared to the predicted dose. In order to correct the dose discrepancy, the off-axis correction is applied to VARIAN iX linear accelerators. The portal dose for $38{\times}28cm^2$ open field is acquired for 6 MV, 15 MV photon beams and also are predicted by PDIP algorithm under the same condition of the portal dose acquisition. The off-axis correction is applied by modifying the $40{\times}40cm^2$ diagonal beam profile data which is used for the beam profile calibration. The ratios between predicted dose and measured dose is modeled as a function of off-axis distance with the $4^{th}$ polynomial and is applied to the $40{\times}40cm^2$ diagonal beam profile data as the weight to correct measured dose by EPID detector. The discrepancy between measured dose and predicted dose is reduced from $4.17{\pm}2.76$ CU to $0.18{\pm}0.8$ CU for 6 MV photon beam and from $3.23{\pm}2.59$ CU to $0.04{\pm}0.85$ CU for 15 MV photon beam. The passing rate of gamma analysis for the pyramid fluence patten with the 4%, 4 mm criteria is improved from 98.7% to 99.1% for 6 MV photon beam, from 99.8% to 99.9% for 15 MV photon beam. IMRT QA is also performed for randomly selected Head and Neck and Prostate IMRT plans after applying the off-axis correction. The gamma passing rare is improved by 3% on average, for Head and Neck cases: $94.7{\pm}3.2%$ to $98.2{\pm}1.4%$, for Prostate cases: $95.5{\pm}2.6%$, $98.4{\pm}1.8%$. The gamma analysis criteria is 3%, 3 mm with 10% threshold. It is considered that the off-axis correction might be an effective and easily adaptable means for correcting the discrepancy between measured dose and predicted dose for IMRT QA using EPID in clinic.

Screw Joint Stability under Cyclic Loading of Zirconia Implant Abutments (지르코늄 임플란트 지대주의 나사결합부 안정성에 관한 연구)

  • Lee, Mi-Soon;Suh, Kyu-Won;Ryu, Jae-Jun
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.47 no.2
    • /
    • pp.164-173
    • /
    • 2009
  • Purpose: The purpose of this study was to evaluate the effect of abutment material on screw-loosening before and after cyclic loading. Among the different materials of abutments, zirconia and metal abutment were used. Material and methods: Two types of implant systems: external butt joint(US II, Osstem Implant, Korea) and internal conical joint(GS II, Osstem Implant, Korea) were used. In each type, specimens were divided into two different kinds of abutments: zirconia and metal(n=5). The implant was rigidly held in a special holding to device ensure fixation. Abutment was connected to 30 Ncm with digital torque gauge, and was retightened in 30 Ncm after 10 minutes. The initial removal torque values were measured. The same specimens were tightened in 30 Ncm again and held in the cycling loading simulator(Instron, USA) according to ISO/FPIS 1480. Cycling loading tests were performed at loads 10 to 250 N, for 1 million cycles, at 14 Hz,(by subjecting sinusoidal wave from 10 to 250 N at a frequency of 14 Hz for 1 million cycles,) and then postload removal torque values were evaluated. Results: 1. In all samples, the removal values of abutment screw were lower than tightening torque values(30 Ncm), but the phenomenon of the screw loosening was not observed. 2. In both of the implant systems, initial and postload removal torque of zirconia abutment were significantly higher than those of metal abutment(P<.05). 3. In both of the implant systems, the difference in removal torque ratio between zirconia abutment and metal abutment was not significant(P>.05). 4. In metal abutments, the removal torque ratio of GS II system(internal conical joint system) was lower than that of US II system(external butt joint system)(P<.05). 5. In zirconia abutments, the difference in removal torque ratio between the two implant systems was not significant(P>.05). Conclusion: Zirconia abutment had a good screw joint stability in the condition of one million cycling loading.

Application of the Artificial Mussel for Monitoring Heavy Metal Levels in Seawater of the Coastal Environments, Korea (Artificial mussel을 이용한 우리나라 연안환경의 중금속 오염도 연구)

  • Ra, Kongtae;Kim, Joung-Keun;Kim, Kyung-Tae;Lee, Seung-Yong;Kim, Eun-Soo;Lee, Jung-Moo;Wu, Rudolf S.S.
    • Journal of the Korean Society for Marine Environment & Energy
    • /
    • v.17 no.2
    • /
    • pp.131-145
    • /
    • 2014
  • The new passive sampler called "artificial mussel (AM)" offers a potential device to study the spatiotemporal changes of metal concentrations in different marine environment worldwide. The purpose of this study is to characterize metal (Cd, Cr, Cu, Zn, Pb) accumulation on the AM and transplanted mussel (Mytilus edulis) at 5 sites of Lake Shihwa. Both the AMs and mussels showed increasing concentrations of all five metals during the 12 weeks exposure period. Higher concentrations of Zn were showed in both the AMs and Mytilus edulis relative to other metals. The AMs accumulated higher concentrations of Cd, Cr and Zn, but they presented lower levels of Cu and Pb than Mytilus edulis. The correlations for Cd, Cu and Pb were statistically significant between the AMs and Mytilus edulis, indicating that the accumulation patterns for those metals were similar. However, no similarities for Cr and Zn were observed between two monitoring devices across all of the sites in Shihwa Lake. According to relationship for metal concentrations between dissolve phase in seawater and both the AMs and Mytilus edulis, the AMs for Cd, Cu and Zn represent more metal contamination than Mytilus edulis. Our results indicated that the AMs give a better resolution to reveal the spatial differences in dissolved metal concentration. This study suggests that the AMs can provide a time-integrated estimate of metal pollution in marine environments as well as freshwater environments of Korea.

Pornographic Animation's Sexuality through Japanese Sex Culture (일본의 성문화를 통해 본 포르노그래피 애니메이션의 선정성)

  • Choi, Eun-Hye;Oh, Jin-Hee
    • Cartoon and Animation Studies
    • /
    • s.36
    • /
    • pp.281-302
    • /
    • 2014
  • Human beings have advanced to release instinctive desire. Among the human desires, sexual desire is classed as a basic desire with appetite and has been expressed in many ways from prehistoric times to present. Despite the social and ethical restriction, expression of sexual image has been evolved with change of time and medium's development. Thanks to inventing the photograph technique, Change of pornographic image has showed a dramatic aspect since early 20th century. The video which delivers message more directly than the picture boosted this change, and the animation has experimented the expression methods and techniques numerously exceeding the limit of realistic image which reappeared by the device. In this thesis, I want to discuss how human beings express sexual desire in animation based on society's sex culture, and analyzed Japanese pornographic animation as its obvious cases. Japanese pornographic animation should be interpreted as the result of culture and society system's history. Through Heian, Edo and early Meiji period, Japanese sex culture has been kept very openly and preposterously. Transformation, metamorphosis, pedophilia, tentacle sex and exposure of specific body parts that are frequently appear in Japanese animation can be interpreted by ancient Japanese open sex culture like Wakashu, polygamy, sleeping in mixed sex group and pederasty. These Japanese odd sex culture is hard to find elsewhere and settled as intrinsic sexual expression in Japanese animation. This situation was institutionally severed by European Modernization's force at the end of World War II in 20th century. However, it seems they have been keeping their influence in a proper form until now. In this study, I discussed that pornographic animation should be interpreted in a frame of cultural phenomenon by researching the series of procedure that ancient Japanese open sex culture has been changed by the system. Sexuality which is found in general Japanese animation was started from their history, and the dichotomous expression about women can be understood that it is bent by institutionally regulated sexual opinion. Japanese history and culture can be understood that it is transformed to the dichotomy that are simultaneously according freedom of eroticism to the pornographic animation, and the fear and irresistible temptation about the woman's body as the other.

Effects of Postoperative Radiotherapy on Distribution of Bone Metastases in Breast Cancer (유방암환자에서 수술 후 방사선치료가 골전이 분포에 미치는 영향)

  • Kim, Bo-Kyoung;Ha, Sung-Whan
    • Radiation Oncology Journal
    • /
    • v.19 no.3
    • /
    • pp.211-215
    • /
    • 2001
  • Purpose : This study was done to evaluate the efficacy of low-dose radiation in reduction of thoracic vertebral metastases in patients with breast cancer. Materials and Methods : 109 patients who were treated for bone metastasis from breast cancer from June, 1988 to June, 1998 in the Department of Therapeutic Radiology, Seoul National University were included. Of the 109 patients, 40 patients had been previously treated by postoperative radiotherapy and 69 had not. Postoperative radiotherapy had been given using Co-60 teletherapy device in 30 patients or 6 MV linear accelerator in 10. Thoracic spines from 1 to 10 were usually irradiated except in 1 patient and cervical vertebrae 6 and/or 7 were partially included in ,: patients. A total of 50.4 Gy was given with 1.8 Gy fraction. Metastatic bone diseases were scored in 11 regions, i. e., skull, conical spine, thoracic spine from 1 to 4, from 5 to 8, 9 and 10, 11 and 12, lumbar spine, pelvis, femur, ribs and others. Results : In no postoperative parasternal irradiation group, lumbar vertebrae were the most common metastatic sites $(55.1\%)$ followed by pelvis $(44.9\%)$, ribs $(40.6\%)$, thoracic vertebrae 11 and 12 $(37.7\%)$, thoracic vertebrae between 5 and 8 $(36.2\%)$, thoracic vertebrae 9 and 10 $(34.8\%)$, and thoracic vertebrae between 1 and 4 $(26.1\%)$. In postoperative parasternal irradiation group, lumbar vertebrae and pelvis were also the most common sites of metastases ($55.0\%$, respectively) followed by ribs $(37.5\%)$, and thoracic vertebrae 11 and 12 $(32.5\%)$. But significant less metastases were seen at thoracic vertebrae from 1 to 10. Conclusion : We can find that the were significantly less bony metastases at thoracic vertebrae which had been previously irradiated postoperatively.

  • PDF