Optimal design of dual magnetic float type level gauge to detect a specific level (특정 레벨을 검출하기 위한 2단 Magnetic Float 타입 레벨 게이지의 최적 설계에 관한 연구)

  • Kim, Dong-Sok;Han, Jae-Man;Park, Gwan-Soo
    • Journal of Sensor Science and Technology
    • /
    • v.17 no.4
    • /
    • pp.308-316
    • /
    • 2008
  • For the measurement of liquid level in ship's cargo tank, ballast tank, fuel oil tank and fresh water tank, several types of gauge meter are used such as tubular type, magnetic float type, reflex type transparent type and welding pad type. Among them, magnetic float type gauge meter is environmental friendly device because it is free of power source and maintenance. The main obstacle of the device is relatively large error bound. In this paper, finite element method is used to design and analysis of the magnetic float type gauge meter. The operation of reed switch according to the magnetic field has been successfully described and agreed well with experimental measurement. The optimum geometry with combination of permanent magnet and reed switches are designed to achieve 98 % accuracy of fluid level.

Agitation Performance Study of 2-shafts Agitator Rotate Directio in the Mud Tank Based on CFD (CFD를 이용한 머드 탱크 2축 교반기의 회전방향에 따른 교반성능 연구)

  • Im, Hyo-Nam;Lee, Hee-Woong;Lee, In-Su;Choi, Jae-Woong
    • Journal of Ocean Engineering and Technology
    • /
    • v.28 no.2
    • /
    • pp.111-118
    • /
    • 2014
  • In drilling process of oil wells, the drilling fluid such as mud keeps the drill bit cool and clean during drilling, with suspending drill cuttings and lubricating a drill bit. In this paper, a commercial CFD package(ANSYS Fluent 15.0) was used to solve the hydrodynamic force and evaluate mud mixing time in the mud mixing tank on offshore drilling platforms. Prediction of power consumption in co-rotating and counter-rotating models has been compared with results of Nagata's correlation equation. This research shows the hydrodynamic effect inside the two phase mud mixing tank according to rotating directions(co-rotating and counter-rotating). These results, we can conclude that the co-rotating direction of the two shafts with mixing blade in the mud mixing tank can be a preferable in power consumption and mixing time reduction.

The Effect of Added Mass of Water and Breath Mode in Fluid-Structure Coupled Vibration Analysis (부가질량 효과와 호흡모드를 고려한 구조-유체연성진동해석)

  • Bae, S.Y.
    • Journal of Power System Engineering
    • /
    • v.9 no.4
    • /
    • pp.71-76
    • /
    • 2005
  • Marine structures are often in contact with inner or outer fluid as stern, ballast and oil tanks. The effect of interaction between fluid and structure has to be taken into consideration when we estimate the dynamic response of the structure appropriately. Fatigue damages can also be sometimes observed in these tanks which seem to be caused by resonance. Thin walled tank structures in ships which are in contact with water and located near engine or propeller where vibration characteristics are strongly affected by the added mass of containing water. Therefore it is essentially important to estimate the added mass effect to predict vibration characteristics of tank structures. But it is difficult to estimate exactly the magnitude of the added mass because this is a fluid-structure interaction problem and is affected by the free surface, vibration modes of structural panels and the depth of water. I have developed a numerical tool of vibration analysis of 3-dimensional tank structure using finite elements for plates and boundary elements for fluid region. In the present study, the effect of added mass of containing water, the effect of structural constraint between panels on the vibration characteristics are investigated numerically and discussed. Especially a natural frequencies by the fluid interaction between 2 panels and a breath mode of the water tank are focused on.

  • PDF

Assessing the Geometric Integrity of Cylindrical Storage Tanks: A Comparative Study Using Static Terrestrial Laser Scanning and Total Station

  • Mansour Alghamdi;Jinha Jung
    • Korean Journal of Remote Sensing
    • /
    • v.40 no.3
    • /
    • pp.243-255
    • /
    • 2024
  • This study compares Static Terrestrial Laser Scanning (STLS)with the conventional Total Station (TS) method for the geometric assessment of cylindrical storage tanks. With the crucial need for maintaining tank integrity in the oil and gas industry, STLS and TS methods are evaluated for their efficacy in assessing tank deformations. Using STLS and TS, the roundness and verticality of two cylindrical tanks were examined. A deformation analysis based on American Petroleum Institute (API) standards was then provided. Key objectives included comparing the two methods according to API standards, evaluating the workflow for STLS point cloud processing, and presenting the pros and cons of the STLS method for tank geometric assessment. The study found that STLS, with its detailed and high-resolution data acquisition, offers a substantial advantage in having a comprehensive structural assessment over TS. However, STLS requires more processing time and prior knowledge about the data to tune certain parameters and achieve accurate assessment. The project outcomes intend to enhance industry professionals' understanding of applying STLS and TS to tank assessments, helping them choose the best method for their specific requirements.

A Study on the Effect of the Orifice Shape on Oil Outflow from a Damaged Ship (사고 선박 손상부 형상이 기름 유출량에 미치는 영향 연구)

  • Park, Il-Ryong
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.28 no.4
    • /
    • pp.620-631
    • /
    • 2022
  • This paper shows the numerical prediction of the change in oil outflow rate according to the orifice shape of a damaged ship by using the computational fluid dynamics (CFD) analysis method. It also provides discharge coefficients for various orifice shapes to be used in theoretical prediction approaches. The oil outflow from the model ship was analyzed using a multiphase flow method under the condition that the Froude and Reynolds number similitudes were satisfied. The present numerical results were verified by comparing them with the available experimental data. Along with the aspect ratio of the orifice and the wall thickness of the cargo tank, the effects of the orifice shapes defined by mathematical figures on the oil outflow were investigated. To consider more realistic situations, the investigation of the ef ect of the crushed iron plate around the damaged part was also included. The numerical results confirmed the change in oil outflow time for various shapes of the damaged part of the oil tank, and discharge coefficients that quantify the viscous effects of those orifice shapes were extracted. To verify the predicted discharge coefficients, they were applied to an oil spill estimation equation. As a result, a good agreement between the CFD and theoretical results was obtained.

Efficiency of Model Oil Fences for One Vessel Using a Physical Experiment and Numerical Calculation (모형 실험과 수치 해석을 통한 단선용 모형 오일펜스의 성능 해석)

  • Kim, Tae-Ho;Jang, Duck-Jong;Yang, Kyung-Uk;Na, Sun-Chol;Kim, Dae-An
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.41 no.2
    • /
    • pp.140-149
    • /
    • 2008
  • This study evaluated the efficiency of an oil fence and spreading devices for one vessel in a towing tank. A series of model experiments and numerical calculations were conducted using an existing oil fence for two vessels and a new method for one vessel. Models of the oil fence and spreading devices were constructed on $1/20^{th}$ scale from waterproofed nylon fabric and canvas. The tensions acting on the model of the oil fences and the horizontal distance between the spreading devices were calculated numerically while the oil fences were being towed. The results were extremely close to the results of the model experiments. The ratio of the opening width to the total length of the oil fence, which shows the efficiency of the oil fence for one vessel, was 49.7% in 0.4 m/sec. Therefore, the proposed oil fence system should be very useful for oil containment at sea. As the opening width of the oil fence is not proportional to the length of the towing rope, it may be reasonable to maintain the towing rope at approximately 100 m. Furthermore, a reasonable towing speed, when operating the oil fence for one vessel equipped with spreading devices, was within 0.4 m/sec.

Oil Tank Location Problem Solving with Mixed Integer Programming & GIS (혼합정수계획법 및 GIS를 활용한 유류저장탱크의 입지선정)

  • 최기주;김숙희;신강원
    • Journal of Korean Society of Transportation
    • /
    • v.19 no.5
    • /
    • pp.99-108
    • /
    • 2001
  • A framework of using and integrating GIS and OR tools for determining the best site selection has been provided. In this research, we demonstrated that both the P-Median heuristic method and MIP method can be successfully applied to the optimum site selection problem of oil tank location selection. Furthermore, the results identified by both approaches are identical. To accomplish this, both GIS road and maritime networks have been constructed and combined to calculated the minimum distance matrix, which is required by both approaches. After the application to the Korean peninsula, the facility locations chosen are Kunsan, Yosu, Busan, and Okgye for each district. As has been shown, the power of GIS and both algorithm have been demonstrated throughout the research and further similar research can also be conducted using the power of GIS and Operations Research tools.

  • PDF

Collision Analysis of Longitudinal Bulkhead of Container/RO-RO Ship with Trailer (컨테이너/로로 선 종격벽의 트레일러 충돌해석)

  • Kang, Myung-Hun;Song, In;Lee, Sang-Kyun;Kim, Sang-Kon;Cho, Sang-Rai
    • Special Issue of the Society of Naval Architects of Korea
    • /
    • 2013.12a
    • /
    • pp.13-20
    • /
    • 2013
  • In this paper, a collision accident of a container/Ro-Ro ship was numerically analyzed. A container trailer collided with a longitudinal bulkhead of the ship in the accident, which constituted a longitudinal wall of a heavy fuel oil tank. Due to the accident, the bulkhead plate was ruptured and the heavy fuel oil spilled out of the tank. The detailed information regarding the collision velocity and the mass of the trailer was not provided. Therefore, several collision accident scenarios were constructed based upon the arrangement of the ramp way. Each collision accident scenario was analyzed to predict the extents of damage using a commercial numerical package, ABAQUS. Based on the analysis results it is proposed how to minimize the extents of damage. Through the investigations performed in this study it was found that the understandings of various damages due to collision accidents and the developments of structural design guidance against collision are necessary for the betterment of Container/RO-RO ships' performance.

  • PDF

Electrical resistivity monitoring of a scale model experiment for geological $CO_2$ sequestration (전기비저항에 의한 지중저장 이산화탄소 거동관측 모의실험)

  • Park, Mi-Kyung;Jang, Han-Nu-Ree;Kim, Hee-Joon;Wang, Soog-Yun;Lee, Min-Hee
    • 한국지구물리탐사학회:학술대회논문집
    • /
    • 2007.06a
    • /
    • pp.173-178
    • /
    • 2007
  • Time-lapse electrical resistivity measurements have been made in a scale model experiment for geological $CO_2$ sequestration in aquifer. Three types of $CO_2$ injection are tested in a water tank filled with glass beads. These are $CO_2$ dissolved into filtered tap water, $CO_2$ gas, and mineral oil. The mineral oil is a substitute for liquid phase of supercritical $CO_2$. For reconstructing three-dimensional resistivity images, we measure potential differences at 32 potential dipoles on the top surface of the tank due to two current dipoles on the front and back sides. The resultant resistivity images clearly show the movement of injected $CO_2$ in aquifer.

  • PDF

The Study of the Design Tests for Current Capability according to ANSI (ANSI 규격에 의한 주상 변압기의 동압력 내력시험에 관한 연구)

  • Kim, Sun-Koo;Kim, Won-Man;La, Dae-Ryeol;Roh, Chang-Il;Lee, Dong-Jun;Jung, Heung-Soo
    • Proceedings of the KIEE Conference
    • /
    • 2003.07b
    • /
    • pp.909-911
    • /
    • 2003
  • The almost pole transformers are constructed with tank, cover, clamp etc., that contains the insulation oil, core, coil, terminals, bus and the other accessories. If some fault current will be flown by some trouble or accident, interior pressure of the transformer shall be very quickly rise, and mechanical components or insulation oil from the transformer enclosure shall be propelled or dropped from the tank. For the prevention of the above accident, recently the pole transformers should be done 'the Design Tests for Fault Current Capability' according to ANSI C57.12.20(1997) There are two tests method in this standard, Test Number I with a high current arcing fault, without internal fusible elements, shall be conducted on rack enclosure with its minimum designed air space. Test Number II with an internal fusible element, shall be conducted on each enclosure diameter utilizing the internal fusible elements. KEPCO recently request to be done the 'Design Tests for Fault Current Capability' for pole transformers according to KEPCO's standard ES141-$533{\sim}545$, PS141-$482{\sim}518$ and RS141-$611{\sim}628$ that is same with Test Number I of ANSI C57.12.20.

  • PDF