• Title/Summary/Keyword: oil monitoring

검색결과 375건 처리시간 0.034초

냉동기유가 모세관내의 냉매유량에 미치는 영향 (The Effects of Oil on Refrigerant Flow through Capillary Tubes)

  • 홍기수;황일남;민만기
    • 설비공학논문집
    • /
    • 제12권9호
    • /
    • pp.791-801
    • /
    • 2000
  • An experimental study was conducted to analyze the effects of oil on refrigerant flow through adiabatic capillary tubes, and to develop a model for mass flow rates of refrigerant/oil mixture at various capillary tubes and flow conditions. Mass flow rates and the profiles of the pressures and temperatures along the capillary tubes was obtained with the oil concentration of R-22/SUNISO 4GS oil mixture at various test conditions. The flow trends as a function of geometry and flow conditions for pure refrigerant and refrigerant/oil mixture were similar in adiabatic capillary tubes. Mass flow rate of the refrigerant/oil mixture was less than that of pure refrigerant at the same test conditions.

  • PDF

자동차용 엔진오일의 열화도 측정 및 분석 (Measurement and Analysis of Deterioration in the Automobile Engine Oil)

  • 김원태;최만용;박해원;박정학
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2003년도 춘계학술대회 논문집
    • /
    • pp.521-524
    • /
    • 2003
  • This paper is aimed to develop the circuit of a coil-type oil sensor packaged to the automotive engine oil monitoring the deterioration in the driving condition and let a driver notify the optimized time for the exchange of engine oil. By applying the principle which the deterioration of automotive engine oil can be expressed to the dielectric constant, the capacitance bridge circuit and the integrator circuit are designed and packaged to a coil-typed engine oil. In this study. the range of operating temperature of engine oil is experimentally recommended within 55$^{\circ}C$ for the stability of a sensor designed. It is concluded that the characteristics of output voltage converted from the dielectric constant are linearly distributed.

  • PDF

복수 경로를 지닌 자외선 형광측정기를 이용한 오일 산화도 측정장치 (Apparatus for Monitoring Oil Oxidation Using a Plurality of UV Fluorescence Light-reflecting Members)

  • 공호성;한흥구
    • Tribology and Lubricants
    • /
    • 제26권3호
    • /
    • pp.167-174
    • /
    • 2010
  • An apparatus for measuring oil oxidation was developed, which is capable of being mounted to mechanical devices for detecting power of fluorescent light reflected from oil in real time as an indication of the oil oxidation. This device has an advantage over conventional fluorescence spectrometers where the thin film is required for the measurement. Clean and used oil samples (mineral and synthetic oils) were tested by the developed apparatus that calculates a fluorescence quantum yield and a light absorption coefficient of the oil based upon the signals from the two light-receiving members and evaluates the degree of oil oxidation of test oils based on the fluorescence quantum yield. Results generally show that the developed device is able to effectively evaluate oil oxidation characteristics on-site in the field.

유전율에 의한 지반 매질내 유류침투거동 분석 (Evaluation of Oil Infiltration Behavior in Porous Media Using Dielectric Response)

  • 김만일;정교철
    • 지질공학
    • /
    • 제15권1호
    • /
    • pp.29-39
    • /
    • 2005
  • 지반오염을 조사하기 위해서는 시추작업을 통하여 시료를 채취하는 방법이 일반적이지만, 실시간으로 원위치에서 다양한 오염물질들의 오염 도 변화를 체계적으로 모니터링 하는 것은 대단히 어렵다. 본 연구에서는 frequency Domain Reflectometry (FDR) 장비를 고안하여 지반의 유류오염을 파악하기 위한 유전율 측정법의 실험적 접근을 시도하였다. 구체적으로 포화 및 불포화 매질에 대한 유류 오염도 측정 및 체적함수비 (θ/sub w/)와 체적 유류비 ( θ/sub al/)의 관계에서 유전율 상수 반응에 따른 매질의 유류 오염도 등의 측정 가능성을 실내 시험을 통해 검토하였다. 뿐만 아니라 실내 칼럼 시험을 수행하여 포화 매질 내에서 유류 거동 특성을 각기 설치된 FDR 측정 센서를 이용해 모니터링하여 포화 매질의 유효공극률과 유류 잔류비를 측정하였다. 그 결과 초기 공극률 0.40으로 제작된 포화 매질의 유효공극률은 약 0.35로 공극률 대비 약 87.5% 범위내에 존재함을 알 수 있었으며, 유류 잔류비는 약 62.5% 정도로 매우 높게 나타났다.

선박용 유배출 감시 장치를 위한 광산란 탁도 방식의 유분 농도계 개발 (A Design of Oil Content Meter Using Scattered Light Turbidity Method for Oil Discharge Monitoring Equipment)

  • 이승희;양구주;장용석;김재형
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국해양정보통신학회 1998년도 추계종합학술대회
    • /
    • pp.583-587
    • /
    • 1998
  • 본 논문에서는 대형 탱커선의 의무 장비인 유배출 감시 장비 (Oil Discharge Monitoring Equipment)를 위한 유분 농도계의 설계에 대하여 연구하였다. ODME는 국제해사기구 (IMO)에서 일정 ton 이상의 대형 선박에 의무적으로 설치하도록 규정하고 있으며 이는 날로 심각해지는 해양 오염을 방지하는데 목적이 있다. ODME의 구성 요소는 중앙 제어 장치, 유분 농도계, 유량계, 선속계, Sampling System, 배출 제어 장치로 이루어져 있으며 이중 가장 중요한 것은 유분 농도계이다. 이는 선박에서 배출되는 물에 포함된 유 성분을 ppm 단위로 계측하는 것이다. 이를 위한 탁도 측정 방법에는 여러 가지가 있지만, 본 연구에서는 선박에서 사용이 용이한 광산란 방식과 방폭성을 가지는 광섬유를 이용하여 탁도를 측정하는 유분 농도계를 설계하였으며 아울러 이에 대한 탁도 계산 알고리즘에 대하여 고찰하였다. 측정의 정밀도는 0-999ppm 범위에서 $\pm$5%의 오차 이내로 측정이 가능함을 보였다. 이는 IMO의 규격 ($\pm$10%의 오차)에 만족하는 수치이다.

  • PDF

자동변속기 오일 온도센서 출력 이상 진단 로직 개발 (Development of A/T Oil Temperature Sensor Plausibility Diagnostic Logic)

  • 권준의;최영선;심장선
    • 한국자동차공학회논문집
    • /
    • 제13권6호
    • /
    • pp.99-104
    • /
    • 2005
  • The CARB in USA has demanded OBD functions that detect any deterioration of performance of OTS as well as a simple defect of OTS which can affect emission to meet the reinforced emission regulation. In this paper, OTS plausibility monitoring functions to meet the demand from CARB are discussed. The output from OTS is used for the diagnostics of the torque converter clutch stuck and the gear ratio synchronous error. It is possible to diagnose the abnormality of OTS function by considering the oil temperature characteristics which changes according to the driving status of vehicles. In result, the OBD regulations of the CARB can be satisfied obligating car manufacturer to detect any problems in OTS functions which can affect emissions.

유입 변압기 진단을 위한 유중 열화 측정 센서의 개발 (Development of Deterioration Detecting Sensor in Oil for Diagnosis of Oil-Filled Transformers)

  • 민경래;윤용한;김영춘;김재철
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2000년도 하계학술대회 논문집 A
    • /
    • pp.128-130
    • /
    • 2000
  • This paper develops the deterioration detecting sensor in oil to monitor and diagnose oil-filled transformer more effectively. The on-line inspection of the oil-filled transformers used the temperature, the changes of the capacitance, the $tan{\delta}$ in oil. This sensor was designed based on the concentric cylindrical type so that it could be placed inside of the oil-filled transformer. And comparing to the existing system, it was proven to be appropriate. Establishment of the proposed sensor helps to build the confidence in monitoring of the oil-filled transformers.

  • PDF

태안해안국립공원 인근의 허베이스피리트 사고를 포함한 유류유출 해역의 식물플랑크톤 생태계 1. 하계 식물플랑크톤 군집의 연변동 (Phytoplankton Ecosystems at Oil Spill Coasts Including the Hebei Spirit Oil Spill Site Near Taeanhaean National Park, Korea 1. Interannual Variability of Phytoplankton Community in Summer)

  • 이원호;김형섭;조수근
    • Ocean and Polar Research
    • /
    • 제41권1호
    • /
    • pp.1-10
    • /
    • 2019
  • Right after the 2007 Hebei Spirit Oil Spill phytoplankton ecosystems were investigated for 11 years based on the seasonal monitoring of the composition and abundance of phytoplankton species. Comparable time-series data from the 1989 Exxon Valdez or the 2010 Deepwater Horizon Oil Spill sites were not available. It was suggested that the ecological healthiness of phytoplankton ecosystems at EVOS sites had recovered after 10 years following the oil spill based on chlorophyll concentrations even though these concentrations only represented phytoplankton communities in most cases. Chlorophyll concentrations can only reflect limited aspects of highly complex phytoplankton ecosystems. During the last 11 years following the 2017 HSOS, extreme variabilities were met in the seasonally averaged ratios of diatoms to phototrophic flagellates including dinoflagellates based on the microscopic cell countings. Summer phytoplankton communities exhibited some cyclic interannual changes in dominant groups every 2-4 years. During the early years (2008-2010) cryptophytes or raphidophytes (Chattonella spp.) dominated alternately each year, which was repeated again in 2014, 2015 and 2017. Two thecate dinoflagellates, Tripos fusus and Tripos furca, together accounted for 52.5% and 50.0% of all organisms in the summers of 2011 and 2012, respectively, which was repeated again in 2018. Summer occurrence and dominance by the phototrophic flagellates including HABs (Harmful Algal Blooms) species as well as their interannual variabilities in the oil spill sites could be utilized as markers for the stable and long-term management of healthy ecosystems. For this type of scientific ecosystem management monitoring of chlorophyll concentrations may sometimes be insufficient to gain a proper and comprehensive understanding of phytoplankton communities located in areas where oil spills have occurred and harmed the ecosystem.

실시간 감시를 이용한 배전용변압기 과부하 평가 시스템 개발 (Development of Overload Evaluation System of Distribution Transformers using Real-Time Monitoring)

  • 박창호;윤상윤
    • 전기학회논문지
    • /
    • 제59권10호
    • /
    • pp.1741-1747
    • /
    • 2010
  • The development of overload management systems for distribution transformers offers new opportunities for improving the reliability of distribution systems. It allows network planners to optimize the system resource utilization and investment cost. Such an improvement in the flexibility of the distribution network is only possible if the operator has more accurate knowledge of the realtime conditions of distribution transformers. In this paper, we present an improved overload decision system for distribution transformers using realtime monitoring data. Our study can be categorized into two parts: (a) improvement in the criteria for judging the overload conditions of distribution transformers and (b) development of an overload evaluation system using realtime monitoring data. In order to determine the overload criteria, overload experiments are performed on sample transformers; the results of these experiments are used to define the relationship between the transformer overload and the increase in the top-oil temperature. To verify the accuracy of the experimental results, field tests are performed using specially manufactured transformers, the loads and top-oil temperatures of which can be measured. For arriving at online overload decisions, we propose methods whereby the measured load curve can be converted into an overload characteristic curve and the overload time can be calculated for any load condition. The developed system is able to evaluate the overload for individual distribution transformers and calculate the losses using realtime monitoring data.

자동차부품 벤처기업 스마트공장 및 모니터링 시스템 구현 사례연구 (A Case Study on Smart Plant and Monitoring System Implementation of Venture Company for Auto Parts)

  • 한재훈;이덕수;박노국
    • 벤처창업연구
    • /
    • 제12권5호
    • /
    • pp.29-37
    • /
    • 2017
  • 본 연구에서는 설비자동화를 통한 생산성 향상 및 제품품질, 공장 환경 개선, 설비 유지 관리 상태 및 제품 불량 유무 확인 등 제품품질관리를 위해 공장현장내에서 실시간 모니터링을 실시하고, 현장 작업시 발생하는 각종 분진을 제거하고, 작업자 개인 환경을 보호하기 위한 목적으로 스마트 공장을 구축하는 사례를 연구하여 제시하였다. 해당기업은 지방에 소재하고 있는 자동차부품기업이며 주요 연구내용은 스마트공장에 필요한 오일필터 클립핑 자동화 및 모니터링 시스템 개발이다. 스마트 공장 오일 필터 클립핑 자동화는 전기에어부품, 솔레노이드밸브 및 기타와 장비부품 가공 제작 과정으로 구분하여 구현하였으며, 스마트 공장 품질검사 모니터링 시스템은 서버PC 및 S/W, 클라이언트 S/W 및 현황 디스플레이 모니터, 운영자 PC, 운영프로그램, 입력단말기 어플리케이션 등으로 구분하여 실제적으로 구현하였다. 본 연구자료는 스마트공장을 추진하는 자동차부품 벤처기업에게 매우 유용한 자료가 될 것으로 보여진다.

  • PDF