• Title/Summary/Keyword: oil monitoring

Search Result 377, Processing Time 0.029 seconds

A Study on the Tank Monitoring System Using FM-CW (FM-CW파를 이용한 탱크 모니터링 시스템에 관한 연구)

  • 강동균;박규식;김동일
    • Journal of the Korean Institute of Navigation
    • /
    • v.19 no.2
    • /
    • pp.115-120
    • /
    • 1995
  • Recently, the ship automation technology(SAT) has received great attention for the efficient management of the ship with minimum human efforts. Among the SAT, a distance measuring system, the key element is the signal processing unit for the interpretion of the received signal from the remote sensing of the oil tank. In this paper, the tank monitoring system using FM-CW is described for the oil tank level guage measurement with an emphsis of signal processing unit.

  • PDF

Application of On-line Diagnostic System for Oil-filled Power Transformers (대용량 변압기 예방진단 시스템 적용 사례)

  • Kim Y.H.;Lee C.R.;Hwangbo S.W.;;Shin Y.T.;Park K.S.;Lee J.B.
    • Proceedings of the KIEE Conference
    • /
    • summer
    • /
    • pp.590-593
    • /
    • 2004
  • This paper presents recent trends on the on-line monitoring and diagnostic systems for oil-immersed transformers. Specially, our system on YeoSu thermal power plant is introduced for high sensitivity and accuracy of ours. It is combined with communication networks to provide an on-line remote monitoring system. Several alarm criteria are formulated to enable a superimposed monitoring system to perform decisive action. The reasons for monitoring the condition and maintaining the health of electrical apparatus were discussed. The experience at the fields and the criteria for the judgment are also discussed in detail.

  • PDF

Developmemt of automobile sensor monitoring system (자동차 센서 모니터링 시스템 개발)

  • Choi, Nakg-Won;Lee, Sang-Hoon
    • Journal of Sensor Science and Technology
    • /
    • v.14 no.3
    • /
    • pp.150-155
    • /
    • 2005
  • We propose a newly developed automobile sensor monitoring system incorporated with a tire pressure monitoring sensor(TPMS). The RF-transmitter based on a tire pressure sensor, sends a frame data about measured tire-pressure to RF receiver. And the various sensing signals based on sensors such as fuel-level sensor, engine oil level sensor and temperature sensors, are converted into 10-bit digital data. The microprocessor displays converting data such as tire pressure, trip distance, fuel quantity, coolant temperature and car-room temperature, on LCD panel. The proposed system can be successfully adapted to monitoring of the tire pressure and various automobile sensors.

Guideline for the Diagnose of Geotechnical Structure (Underground Oil Storage Cavern) using a Microseismic Monitoring System (음향미소진동기반 모니터링 시스템을 이용한 지반구조물(유류 지하저장시설) 진단평가 가이드라인)

  • Cheon, Dae-Sung;Jung, Yong-Bok
    • Tunnel and Underground Space
    • /
    • v.28 no.4
    • /
    • pp.293-303
    • /
    • 2018
  • Monitoring is the act of collecting and analyzing accurate engineering information using various methods and instruments. The purposes of the monitoring are design verification, construction management, quality control, safety management, and diagnose of structure etc.. The diagnose evaluation of the geotechnical structures corresponds to the confirmation of the structural performance. It is aimed to judge the soundness of geotechnical structures considering the degree of damage due to the environmental change and elapsed time. Recently, microseismicity, which is widely known in Korea, can be used for safety management and diagnoses of structure as it detects the micro-damage without disturbance of the structure. This report provides guideline on the procedure for assessing an underground oil storage cavern using microseismic monitoring techniques. Guidelines cover the selection of monitoring systems, sensor array, sensor installation and operation of systems, and interpretation.

Construction of Oil-Spill Warning System based on Remote Sensing/Numerical Model and Its Application to the Natural Resource Damage Assessment and Restoration System

  • Goto, Shintaro;Kim, Sang-Woo
    • Proceedings of the KSRS Conference
    • /
    • 1999.11a
    • /
    • pp.243-248
    • /
    • 1999
  • From the lessons after the Nakhodka oil-spill in Jan. 1997, oil slick detection by using remote sensing data and assimilating the data to the simulation program is important for monitoring the oil-drift pattern. For this object, we are going to construct the oil-spill warning system for estimating the oil-drift pattern using remotesensing/numerical simulation Model. Additionally we plan to use this system for restorating oil-spill damage domestically, such as estimating the ecological damage and making the priority fur restorating the oil-spilled shoreline. This report is intended to summarize the role of geo-informatics in the oil spill accident by not only paying attention to the effect of information provision/information management via the map, but also reporting the interim result in part based on the details discussed in the processes of recovery support and environmental impact assessment during the Nakhodka's accident.

  • PDF

Monitoring of Microorganisms Added into Oil-Contaminated Microenvironments by Terminal-Restriction Fragment Length Polymorphism Analysis

  • JUNG SEONG-YOUNG;LEE JUNG-HYUN;CHAI YOUNG-GYU;KIM SANG-JIN
    • Journal of Microbiology and Biotechnology
    • /
    • v.15 no.6
    • /
    • pp.1170-1177
    • /
    • 2005
  • Terminal-restriction fragment length polymorphism (T-RFLP) analysis was used to monitor inoculated oil-degrading microorganisms during bioremedial treatability tests. A pair of universal primers, fluorescently labeled 521F and 1392R, was employed to amplify small subunit rDNA in order to simultaneously detect two bacterial strains, Corynebacterium sp. IC10 and Sphingomonas sp. KH3-2, and a yeast strain, Yarrowia lipolytica 180. Digestion of the 5'-end fluorescence/labeled PCR products with HhaI produced specific terminal-restriction fragments (T-RFs) of 185 and 442 bases, corresponding to Corynebacterium sp. IC10 and Y. lipolytica 180, respectively. The enzyme NruI produced a specific T-RF of 338 bases for Sphingomonas sp. KH3-2. The detection limit for oildegrading microorganisms that were inoculated into natural environments was determined to be $0.01\%$ of the total microbial count, regardless of the background environment. When three oil-degrading microorganisms were released into oil-contaminated sand microenvironments, strains IC10 and 180 survived for 35 days after inoculation, whereas strain KH3-2 was detected at 8 days, but not at 35 days. This result implies that T-RFLP could be a useful tool for monitoring the survival and relative abundance of specific microbial strains inoculated into contaminated environments.

On-line Monitoring of Tribology Parameters and Fault Diagnosis for Disc Brake System

  • Yang Zhao-Jian;Kim Seock-Sam
    • Proceedings of the Korean Society of Tribologists and Lubrication Engineers Conference
    • /
    • 2003.11a
    • /
    • pp.224-228
    • /
    • 2003
  • The basic Principles and methods of the on-line monitoring of tribology parameters (friction coefficient and wear allowance) and fault diagnosis for the hoist disc brake system were introduced, the method were based on the spring force and oil pressure of the brake system and the hoist kinematics parameters. The experiment on the monitoring and diagnosis of hoist brake system were carried out. The research results showed: the monitoring and diagnosis methods are feasible.

  • PDF

A Study on Deterioration Measurement Sensor in the Automobile Engine Oil (자동차용 엔진오일의 열화도 측정 센서연구)

  • Kim, Won-Tae;Choi, Man-Yong;Park, Hae-Won;Park, Jung-Hak
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.24 no.3 s.192
    • /
    • pp.61-66
    • /
    • 2007
  • This work is aimed to measure the deterioration in oil sensor. For the study, the circuit of a coil-type oil sensor packaged was developed and applied to the automobile engine for monitoring the deterioration of engine oil in driving conditions. From the principle which the deterioration of automobile engine oil can be expressed to the dielectric constant, the capacitance bridge circuit and the integrator circuit were designed. As results, the range of operating temperature of engine oil was experimentally recommended within $55^{\circ}C$ for the stability of a sensor designed. It was also concluded that the characteristics of output voltage converted from the dielectric constant were linearly distributed and predicted the optimized time for the exchange of engine oil.