• Title/Summary/Keyword: offset filter

검색결과 248건 처리시간 0.032초

고차 구성의 개선된 직류 옵셋 제거 필터 (Advanced DC Offset Removal Filter of High-order Configuration)

  • 박철원
    • 전기학회논문지P
    • /
    • 제62권1호
    • /
    • pp.12-17
    • /
    • 2013
  • Fault currents are expressed as a combination of harmonic components and exponentially decaying DC offset components, during the occurrence of fault in power system. The DC offset components are included, when the voltage phase angle of fault inception is closer to $0^{\circ}$ or $180^{\circ}$. The digital protection relay should be detected quickly and accurately during the faults, despite of the distortions of relaying signal by these components. It is very important to implement the robust protection algorithm, that is not affected by DC offset and harmonic components, because most relaying algorithms extract the fundamental frequency component from distorted relaying signal. So, In order to high performance in relaying, advanced DC offset removal filter is required. In this paper, a new DC offset removal filter, which is no need to preset a time constant of power system and accurately estimate the DC offset components with one cycle of data, is proposed, and compared with the other filter. In order to verify performance of the filter, we used collecting the current signals after synchronous machine modeling by ATPDraw5.7p4 software. The results of simulation, the proposed DC offset removal filter do not need any prior information, the phase delay and gain error were not occurred.

1회선 송전선로 단락사고의 개선된 고장점 표정기법 (Enhanced Fault Location Algorithm for Short Faults of Transmission Line)

  • 이경민;박철원
    • 전기학회논문지
    • /
    • 제65권6호
    • /
    • pp.955-961
    • /
    • 2016
  • Fault location estimation is an important element for rapid recovery of power system when fault occur in transmission line. In order to calculate line impedance, most of fault location algorithm uses by measuring relaying waveform using DFT. So if there is a calculation error due to the influence of phasor by DC offset component, due to large vibration by line impedance computation, abnormal and non-operation of fault locator can be issue. It is very important to implement the robust fault location algorithm that is not affected by DC offset component. This paper describes an enhanced fault location algorithm based on the DC offset elimination filter to minimize the effects of DC offset on a long transmission line. The proposed DC offset elimination filter has not need any erstwhile information. The phase angle delay of the proposed DC offset filter did not occurred and the gain error was not found. The enhanced fault location algorithm uses DFT filter as well as the proposed DC offset filter. The behavior of the proposed fault location algorithm using off-line simulation has been verified by data about several fault conditions generated by the ATP simulation program.

직류옵셋제거필터에 의한 거리계전기법의 성능 개선에 관한 연구 (A Study on Performance Enhancement of Distance Relaying by DC Offset Elimination Filter)

  • 이경민;박유영;박철원
    • 전기학회논문지P
    • /
    • 제64권2호
    • /
    • pp.67-73
    • /
    • 2015
  • Distance relay is widely used for the protection of long transmission line. Most of distance relay used to calculate line impedance by measuring voltage and current using DFT. So if there is a computation error due to the influence of phasor by DC offset component, due to excessive vibration by measuring line impedance, overreach or underreach can be occurs, and then abnormal and non-operation of distance relay can be issue. It is very important to implement the robust distance relaying that is not affected by DC offset component. This paper describes an enhanced distance relaying based on the DC offset elimination filter to minimize the effects of DC offset on a long transmission line. The proposed DC offset elimination filter has not need any prior information. The phase angle delay of the proposed DC offset filter did not occurred and the gain error was not found. The enhanced distance relay uses fault current as well as residual current. The behavior of the proposed distance relaying using off-line simulation has been verified using data about several fault conditions generated by the ATP simulation software.

새로운 직류 옵셋 제거 필터에 의한 정확한 페이저 추출에 관한 연구 (A Study on Accurate Phasor Extraction Using a New DC Offset Elimination Filter)

  • 박철원;윤희환
    • 조명전기설비학회논문지
    • /
    • 제27권7호
    • /
    • pp.29-36
    • /
    • 2013
  • In this paper, a new DC offset elimination filter is proposed for an accurate phasor extraction of fundamental frequency component. The proposed method can eliminate a DC offset component which is decayed exponentially. The proposed method uses only one cycle of data for phasor extraction computation, which does not need to preset the time constant of the DC offset component. Also, the other advantages of the proposed method is that gain compensation or phase compensation is not required after filtering. Simulations using ATP were performed to evaluate the performance of the proposed filter method, and the results were compared to the ones obtained by conventional methods.

A Method for Estimating an Instantaneous Phasor Based on a Modified Notch Filter

  • Nam Soon-Ryul;Sohn Jin-Man;Kang Sang-Hee;Park Jong-Keun
    • Journal of Electrical Engineering and Technology
    • /
    • 제1권3호
    • /
    • pp.279-286
    • /
    • 2006
  • A method for estimating the instantaneous phasor of a fault current signal is proposed for high-speed distance protection that is immune to a DC-offset. The method uses a modified notch filter in order to eliminate the power frequency component from the fault current signal. Since the output of the modified notch filter is the delayed DC-offset, delay compensation results in the same waveform as the original DC-offset. Subtracting the obtained DC-offset from the fault current signal yields a sinusoidal waveform, which becomes the real part of the instantaneous phasor. The imaginary part of the instantaneous phasor is based on the first difference of the fault current signal. Since a DC-offset also appears in the first difference, the DC-offset is removed trom the first difference using the results of the delay compensation. The performance of the proposed method was evaluated for a-phase to ground faults on a 345kV 100km overhead transmission line. The Electromagnetic Transient Program was utilized to generate fault current signals for different fault locations and fault inception angles. The performance evaluation showed that the proposed method can estimate the instantaneous phasor of a fault current signal with high speed and high accuracy.

A New Orthogonal Signal Generator with DC Offset Rejection for Single-Phase Phase Locked Loops

  • Huang, Xiaojiang;Dong, Lei;Xiao, Furong;Liao, Xiaozhong
    • Journal of Power Electronics
    • /
    • 제16권1호
    • /
    • pp.310-318
    • /
    • 2016
  • This paper presents a new orthogonal signals generator (OSG) with DC Offset rejection for implementing a phase locked loop (PLL) in single-phase grid-connected power systems. An adaptive filter (AF) based on the least mean square (LMS) algorithm is used to constitute the OSG in this study. The DC offset in the measured grid voltage signal can be significantly rejected in the developed OSG technique. This generates two pure orthogonal signals that are free from the DC offset. As a result, the DC offset rejection performance of the presented single-phase phase locked loop (SPLL) can be enhanced. A mathematical model of the developed OSG and the principle of the adaptive filter based SPLL (AF-SPLL) are presented in detail. Finally, simulation and experimental results demonstrate the feasibility of the proposed AF-SPLL.

정합필터 기반의 Chirp Spread Sprectrum을 위한 새로운 주파수 오프셋 추정 알고리즘 (A Novel Frequency Offset Estimation Algorithm for Chirp Spread Spectrum Based on Matched Filter)

  • 김영삼;정정화
    • 대한전자공학회논문지TC
    • /
    • 제47권10호
    • /
    • pp.1-7
    • /
    • 2010
  • 본 논문에서는 정합필터 기반의 IEEE 802.15.4a chirp spread spectrum (CSS)을 위한 새로운 주파수 오프셋 추정 알고리즘을 제안한다. 기존의 주파수 오프셋 추정 알고리즘은 연속되는 동일한 심볼 간의 차등 위상을 계산함으로서 주파수 오프셋을 추정하였다. 하지만 CSS는 긴 십볼 구간과 가드 구간을 포함하고 있어 기존의 방법으로 주파수 오프셋을 추정하였을 경우 위상 모호성이 발생한다. 특히 정합필터 기반 수신기 구조에서 위상 모호성을 해결하지 않는다면 주파수 오프셋에 의한 정현파 간섭 현상으로 정합필터의 성능이 감소하게 된다. 따라서 본 논문에서는 위상 모호성을 해결하기 위해 정수부와 소수부 주파수 오프셋 추정을 분할화 하여 주파수 오프셋을 추정하는 새로운 알고리즘을 제안한다. 제안하는 알고리즘은 sub-chirp 간 정합필터 결과의 차등 위상을 계산 한 결과와 기존의 심볼 간 차등 위상 정보를 이용하여 정수부 주파수 오프셋을 추정하여 위상 모호성을 제거 한 후, 심볼 간 차등위상 정보를 통하여 소수부 주파수 오프셋을 추정한다. 시뮬레이션 결과 제안하는 알고리즘은 정수부 주파수 오프셋 추정을 통해 위상 모호성 문제를 해결할 수 있음을 확인하였고 위상 모호성 이 발생하지 않는 경우에서도 기존의 알고리즘과 거의 통일한 성능을 보임을 확인하였다.

HEVC에서 SAO의 성능개선을 위한 edge offset category 분류 방법 (Edge offset category classification method for improving the performance of SAO in HEVC)

  • 정연경;한종기
    • 한국방송∙미디어공학회:학술대회논문집
    • /
    • 한국방송공학회 2013년도 하계학술대회
    • /
    • pp.354-356
    • /
    • 2013
  • ITU와 ISO/IEC가 공동으로 UHD급 영상 부호화를 위해 표준화를 진행하고 있는 HEVC 코덱은 H.264/AVC 대비 2배 이상의 압축 효율을 갖는 것을 목표로 정하고 있다. HEVC(High Efficiency Video Coding)는 In-Loop Filter 기술로 H.264/AVC에서 사용하고 있는 Deblocking Filter와 새롭게 추가 된 SAO(Sample Adaptive Offset)를 사용하고 있다. 본 논문에서는 HEVC의 In-Loop Filter 기술 중 하나인 SAO의 기술의 EO에서 Category를 조금 더 정확하게 판단하여 분류하는 방법을 제안을 한다.

  • PDF

계통사고시 지수함수 형태로 감소하는 DC-Offset 성분을 계전신호에서 제거하는 Digital Filter 디자인 (Digital Filter Design for Removing Exponentially Decaying DC-Offset Component from Relaying Signal)

  • 강상희;김남호;강용철;김일동;박종근
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1992년도 하계학술대회 논문집 A
    • /
    • pp.59-62
    • /
    • 1992
  • Power system fault transient signals are highly distorted due to the presence of high frequency components in the voltage and current signals and an exponentially decaying dc-offset component in the current signals. Modern protective relays have to make reliable fast decisions about the nature of a fault in the presence of such transients. To use a dc-offset removing filter makes relay algorithms much fast and reliable for detecting a fault. In this paper, several dc-offset removing filters are described, and characteristics of them are compared.

  • PDF

병행 2회선 송전선로의 개선된 거리계전기법 (Advanced Distance Relaying of on a Double Circuit Transmission Line)

  • 박철원
    • 조명전기설비학회논문지
    • /
    • 제29권8호
    • /
    • pp.23-31
    • /
    • 2015
  • This paper proposes an advanced distance relaying based on the DC offset removal filter to minimize the effects of DC offset on a double circuit transmission line. The proposed DC offset removal filter uses only one cycle of data for phasor extraction computation, which does not need to preset the time constant of the DC offset component. This proposed distance relaying uses not only the residual current of the faulted circuit but also mutual current of the healthy adjacent circuit. A series of off-line test results using ATP simulation data show the effectiveness of the an advanced distance relaying.